Loading...
HomeMy WebLinkAboutA0.01 Foundation - Basement##########################Midwest Zone Office1900 Golf Road - Suite 300Schaumburg, Illinois 60173(c) Copyright 2019 PulteGroup, Inc. PRODUCT MANAGERRick StarkeyVERSION RELEASEDATE:05/10/2019 PROJECT TYPE Single Family SHEET PLAN NAME SPECIFICATION LEVEL NPC CHILD NUMBER ---- Allison II 2377.300Home for * Market Home *, 7774-0030014557 MAULDIN ST, Carmel, IN 46074BASEMENT FOUNDATION PLANSCALE: 1/4" = 1'-0" (HALF SCALE ON 11x17 PAPER) SUMP w/ CHECK VALVE, VERIFY LOCATIONOPT. EJECTOR PIT AND PUMP AS REQUIRED, VERIFY LOCATIONPROVIDE SEPARATION BETWEEN WATER & SEWER LINES, PER CODE FURNACE PER MECHANICAL PLANSWATER HEATER, PER SPECOPT. WATER SOFTENER, PER SPECRADON VENT PER CODE, VERIFY LOCATIONPERIMETER DRAIN, PER SPEC UP 7 RISERS HANDRAIL, PER CODE1234567POST & BEAM PER STRUCTURAL PLANSPOST & BEAM PER STRUCTURAL PLANS12\pxql;2/8FLOOR DRAIN, VERIFY LOCATION 4140 SL & EGRESS WELL #4, AS REQUIRED BY CODE\PSEE STRUCTURAL DETAILS OPT\PROUGH IN BATH POST & BEAM PER STRUCTURAL PLANS ADD RISER W/ OPT. 9'-0" POUR LEAD WALL PAST OVERDIG, TYP. (SEE STRUCTURAL)\pxql;PAD FOOTING w/ OUTDOOR FIREPLACE OPTION \A1;23'-0"\A1;10'-7{\H0.75x;\S1#2;}" \A1;10'-3{\H0.75x;\S1#2;}"\A1;3'-6{\H0.75x;\S1#2;}"\A1;3'-6{\H0.75x;\S1#2;}"\A1;16'-3" \A1;11'-4" \A1;18'-3{\H0.75x;\S1#2;}" \A1;18'-11{\H0.75x;\S1#2;}"\A1;19'-8{\H0.75x;\S1#2;}" \A1;12'-3" \A1;5'-11" \A1;4'-7{\H0.75x;\S1#4;}" \A1;7'-0" \A1;48'-7" - OVERALL \A1;31'-11{\H0.75x;\S1#2;}" \A1;16'-7{\H0.75x;\S1#2;}" \A1;2'-11{\H0.75x;\S3#4;}" \A1;5'-3{\H0.75x;\S1#2;}" \A1;2'-10{\H0.75x;\S3#4;}"\A1;20'-10"\A1;1'-5{\H0.75x;\S1#2;}" \A1;2'-7{\H0.75x;\S1#2;}"\A1;14'-0" \A1;17'-8" \A1;12'-0"\A1;42'-3{\H0.75x;\S1#2;}" LEAD WALL PAST OVERDIG, FIELD VERIFY LOCATION\P(TYP.)\A1;33'-7{\H0.75x;\S1#2;}" \A1;29'-7{\H0.75x;\S1#2;}" \A1;48'-7" - OVERALL \A1;20'-4{\H0.75x;\S1#2;}" \A1;9'-3" \A1;67'-7" - OVERALL\A1;20'-11{\H0.75x;\S1#2;}" \A1;67'-7" - OVERALL \A1;11'-11{\H0.75x;\S1#2;}" \A1;1'-11" \A1;16'-3" \A1;2'-2{\H0.75x;\S1#2;}"\A1;6{\H0.75x;\S1#2;}" \A1;8'-3" \A1;5{\H0.75x;\S1#2;}" \A1;1'-0" \A1;10'-8" \A1;8'-0" \A1;1'-9{\H0.75x;\S1#2;}" \A1;4'-5" \A1;1'-9{\H0.75x;\S1#2;}" \A1;2'-8"\A1;1'-9{\H0.75x;\S1#2;}"\A1;10{\H0.75x;\S1#2;}"\A1;5'-4"\A1;1'-9{\H0.75x;\S1#2;}"\A1;3'-6{\H0.75x;\S1#2;}" \A1;8'-10{\H0.75x;\S1#2;}" \A1;1'-9{\H0.75x;\S1#2;}" LEAD WALL PAST OVERDIG, FIELD VERIFY LOCATION\P(TYP.) \A1;47'-7" TO CORNER \A1;10'-2{\H0.75x;\S1#2;}" \A1;4'-10{\H0.75x;\S1#2;}" \A1;13'-1{\H0.75x;\S1#2;}" \A1;1'-7{\H0.75x;\S1#2;}" \A1;3{\H0.75x;\S1#2;}" 2A2 B.1 1A2 B.1 1A2 B.1 2A2 B.1 3A2 B.2 3A2 B.2 4A2 B.2 4A2 B.2 SLAB/UNEXCAVATED (SEE STRUCTURAL PLANS) SLOPECONCRETE SLABUNEXCAVATED (SEE STRUCTURAL PLANS)BASEMENT UNFINISHEDSLAB (SEE STRUCTURAL PLANS)HVACOPT. GAS VALVE UNEXCAVATED(SEE STRUCTURAL PLANS)CONCRETE SLABUNEXCAVATED(SEE STRUCTURAL PLANS)CONCRETE SLABAlternate Sump Location 08/12/22