HomeMy WebLinkAboutA4.01 Roof PlanOPT. GUTTER & DOWNSPOUTS, PER SPEC (VERIFY LOCATIONS) \A1;3'-0" MIN. 122 SQ. IN. OF VENTILATION REQUIRED AT EAVE FOR PORCH OPT. GUTTER AND DOWNSPOUTS \A1;1'-0"\PTYP. \A1;1'-0"\PTYP. PROVIDE ADEQUATE OPENING FOR AIR MOVEMENT BETWEEN ATTIC SPACES TO SUPPORT REQUIRED VENTILATION OPT. POT VENTS \A1;19'-0"\A1;7'-0" \A1;6'-0" \A1;6'-0" \A1;3'-0" \A1;7'-0" \A1;1'-0"\PTYP. \A1;5'-0" \A1;1'-0"\PTYP. \A1;3'-0" \A1;3'-0" 4:12 4:12 "C" 168 ROOF AREA: SQ. FT. 10:12 10:12 10:1210:12 10:12 10:127:12 7:12 7:12 7:12 4:12 10:12 10:12 10:12 10:12 10:12 4:12 "A" 2018 ROOF AREA: SQ. FT.10:12 "B" 406 ROOF AREA: SQ. FT.ROOF AREA "B"SQ FTG401AT / NEAR RIDGEAT / NEAR EAVEVENT TYPESQ. FT.REQUIREDRANGESQ. FT.SUPPLIEDPERCENTOF TOTALSUPPLIEDPOT LARGE(SQ. IN. EACH)POT SMALL(SQ. IN. EACH)RIDGE VENT(SQ. IN. PER LF)EAVE VENT(SQ. IN. EACH)CONT. VENT(SQ. IN. PER LF)61.0040.0018.0028.0010.00HIGH - POTVENTS ONLY0.530.670.8548.4120AT EAVE0.800.670.9051.59013.00TOTAL (MIN)1.341.341.75100.003 HIGH -RIDGE VENT0.530.670.6345.00005.00AT EAVE0.800.670.7655.00011.00TOTAL (MIN)1.341.341.39100.00ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLEATTIC VENT SCHEDULEVENTILATION REQUIRED AND SUPPLIED IS BASED ON POT VENT VALUES AND RIDGE VENT VALUES SHOWN IN TABLE ABOVE** CONTRACTORS INSTALLING VENTILATION ARE RESPONSIBLE FOR VERIFYING THAT VENTS USED WILL SUPPY VENTILATION TO MEET CODE REQUIREMENTS* SCHEDULE HAS BEEN CALCULATED ASSUMING EAVE VENTILATION AT 50-60% OF TOTAL AND RIDGE AT 40-50% OF TOTAL REQUIRED VENTILATIONELEVATION NC2GROOF AREA "A"SQ FTG2018AT / NEAR RIDGEAT / NEAR EAVEVENT TYPESQ. FT.REQUIREDRANGESQ. FT.SUPPLIEDPERCENTOF TOTALSUPPLIEDPOT LARGE(SQ. IN. EACH)POT SMALL(SQ. IN. EACH)RIDGE VENT(SQ. IN. PER LF)EAVE VENT(SQ. IN. EACH)CONT. VENT(SQ. IN. PER LF)61.0040.0018.0028.0010.00HIGH - POTVENTS ONLY2.693.363.3949.3980AT EAVE4.043.363.4750.61050.00TOTAL (MIN)6.736.736.86100.003 HIGH -RIDGE VENT2.693.363.2548.350026.00AT EAVE4.043.363.4751.65050.00TOTAL (MIN)6.736.736.72100.00ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLEA4.01 ROOF PLANMidwest Zone Office1900 Golf Road - Suite 300Schaumburg, Illinois 60173(c) Copyright 2019 PulteGroup, Inc. PRODUCT MANAGERRick StarkeyVERSION RELEASEDATE:05/10/2019 PROJECT TYPE Single Family SHEET PLAN NAME SPECIFICATION LEVEL NPC CHILD NUMBER ---- Allison II 2377.300Home for * Market Home *, 7774-0030014557 MAULDIN ST, Carmel, IN 46074ROOF PLANSCALE: 1/4" = 1'-0" (HALF SCALE ON 11x17 PAPER) 08/12/22