Loading...
HomeMy WebLinkAbout12955 Old Meridian St - Existing Drainage Information C0-4OLD MERIDIAN STREET46 PROPOSED BUILDING 5,940 SQ.FT. SHEET FLOW SHEET FL O W SHEET FL O W SHEET FL O W SH E E T F L O W 60 LF OF 10" HDPE @ 1.00 % SLOPE 6 5 L F O F 1 2 " H D P E @ 1 . 0 0 % S L O P E SITE DRAINAGE PLAN Scale: 1" = 30' PROPOSED SITE IMPROVEMENTS 12955 OLD MERIDIAN STREET CARMEL, IN 46032 C19-4744Reference #: M19-4846 PREPARED FOR: DATE REV. DESC.REV. # 05/14/2019 CLH BCR Date Plotted: Drawn By: Approved By: Date of Last Field Work: PROJECT LOCATED IN: Sheet Number : Project Number: DRAWING LEGEND p 494 Gradle Drive Carmel, Indiana 46032 Phone: 317.844.3333 Fax: 317.844.3383 www.seagroupllc.com info@seagroupllc.com Land Surveyors Civil Design G r o u 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 A B C D E F G H I J K L Construction Layout CERTIFIED BY: DATE:05/14/19 Mr. Brent Roberts 934 Fort Wayne Ave Indianapolis, IN 46202 317.439.4355 PHANOMEN/design SECTION 26 - TOWNSHIP 18 NORTH - RANGE 3 EAST CLAY TOWNSHIP, HAMILTON COUNTY 05/13/2019 C3.1 SITE DRAINAGE PLAN PROPERTY BOUNDARY UNDERGROUND ELECTRIC PROPOSED SANITARY LATERAL WATER LINE PROPOSED STORM SEWER UNDERGROUND TELEPHONE UTILITY NOTES: PLAN NOTES: 1. IT SHALL BE THE RESPONSIBILITY OF EACH CONTRACTOR TO VERIFY ALL EXISTING UTILITIES AND CONDITIONS PERTAINING TO THEIR PHASE OF WORK. IT SHALL ALSO BE THE CONTRACTOR'S RESPONSIBILITY TO CONTACT THE OWNERS OF THE VARIOUS UTILITIES FOR PROPER STAKE LOCATIONS FOR EACH UTILITY BEFORE WORK IS STARTED. THE CONTRACTOR SHALL NOTIFY IN WRITING THE OWNER OR THE ENGINEER OF ANY CHANGES, OMISSIONS, OR ERRORS FOUND ON THESE PLANS OR IN THE FIELD BEFORE WORK IS STARTED OR RESUMED. 2. STANDARD SPECIFICATIONS FOR THE CITY OF CARMEL SHALL APPLY FOR ALL SANITARY SEWERS, STORM SEWERS, AND WATER MAINS. 3. ANY PART OF THE SANITARY OR STORM SEWER TRENCHES RUNNING UNDER PAVED AREAS TO BE BACKFILLED TO TOP OF PIPE. 4. ALL WATER LINES TO HAVE A 54" MINIMUM COVER OVER GRANULAR MATERIAL. 5. STERILIZATION OF WATER MAIN SHALL BE IN ACCORDANCE WITH STATE BOARD OF HEALTH AND CITY OF CARMEL UTILITIES REQUIREMENTS. 6. CONTRACTOR RESPONSIBLE TO INSTALL ALL UNDERGROUND CONDUIT PER UTILITY COMPANY'S SPECIFICATIONS. 7. CONTRACTOR RESPONSIBLE FOR RESTORATION TO ALL AREAS AFFECTED DURING CONSTRUCTION. REFER TO THE CITY OF CARMEL STANDARDS AND SPECIFICATIONS AND THE I.N.D.O.T. STREET STANDARDS. 8. CONTRACTOR TO LOCATE ALL EXISTING UTILITIES AT ANY PROPOSED CROSSING AND PROVIDE EXISTING TOP OF PIPE ELEVATIONS WITHIN 10 DAYS OF NOTICE TO PROCEED. PROVIDE CONCRETE CRADLE AS REQUIRED FOR ANY VERTICAL SEPARATION LESS THAN 18 INCHES. 9. ALL PROPOSED STORM SEWER AND DRAINAGE APPURTENANCES SHALL BE IN CONFORMANCE WITH CITY OF CARMEL STORMWATER SPECIFICATIONS MANUAL, LATEST EDITION. DISCREPANCIES BETWEEN THE PLANS AND THE MANUAL SHALL NOT ALLEVIATE THE CONTRACTOR FROM ADHERING TO THE REQUIREMENTS AS SET FORTH IN THE MANUAL. A B D PROPOSED OUTDOOR SEATING AREA. COORDINATE WITH LANDSCAPE ARCHITECT FOR PROPOSED DRAINAGE SYSTEM OUTLET. PROPOSED ROOF DRAIN CONNECTION PER DETAIL THIS SHEET. FINAL LOCATION OF ROOF DRAINS TO BE CONFIRMED BY ARCHITECT. CORE DRILL EXISTING STORM STRUCTURE TO ACCOMMODATE PROPOSED STORM SEWER CONNECTION. CONNECTION SHALL BE IN ACCORDANCE WITH THE CITY OF CARMEL CONSTRUCTION STANDARDS AND SPECIFICATIONS. C ALL STORM SEWER INLETS AND PIPES ON SITE SHALL BE CLEANED WITH HIGH PRESSURE WASHER PRIOR TO BEGINNING CONSTRUCTION. REMOVE RESULTING DEBRIS IN ACCORDANCE WITH THE CITY OF CARMEL CONSTRUCTION STANDARDS AND SPECIFICATIONS. D 1 inch = ft. ( IN FEET ) 0 1 inch = ft. ( IN FEET ) 0 10 20 2020 IMPERVIOUS CALCULATION TOTAL SITE AREA: 98,982 SF TOTAL DISTURBED SITE AREA: 38,475 SF EXISTING IMPERVIOUS SURFACE: 38,220 SF PERCENT OF TOTAL IMPERVIOUS: 99.34% PROPOSED IMPERVIOUS SURFACE: 34,442 SF PERCENT OF TOTAL IMPERVIOUS: 79.07% BUILDING FOUNDATION 6" HPDE RISER FACE OF BUILDING/COLUMN FINISH GRADE PVC DOWNSPOUT ADAPTOR 6" HDPE DOWNSPOUT LEADER WITH MINIMUM 1.00% SLOPE NOTE: VERIFY DIMENSIONS OF DOWNSPOUTS, ADAPTERS, AND PIPE SIZE NECESSARY FOR CONNECTIONS WITH ARCHITECTURAL PLANS STORM SEWER MAIN LINE GRANULAR BACKFILL DOWNSPOUT (REFER TO ARCHITECTURAL PLANS FOR SIZE AND LOCATION) Downspout Connection Detail Not To Scale BUILDING FOOTER PREMANUFACTURED WYE PREMANUFACTURED 90° WYE A A SURFACE FLOW DIRECTION C0-2 EXISTING DRAINAGE INFORMATION (FOR REFERENCE ONLY) C0-4