HomeMy WebLinkAbout06040006 Signed Conditional
PERMIT PLAN REVIEW STOPS
PAGE 1
t' ..--.~
PERMIT NUMBER:
PARCEL 10
PARCEL ADDRS
APPLY DATE
CONTRACTOR
PHONE NUNBER
06040006 - TAYLOR
1713030004028000
10678 WINTERWOOD DR CARMEL.
04/03/06 ISSUE DATE
HAMILTON HOMES
(317) 570-1331
TYPE: RESREMODEL
IN 46032
C/O DATE
FAX NUMBER (317) 570-144
-~~-----~----------------------------------------------------------------------
REVIEW STOP: BLDG
REV NO: 1 STATUS:
REVIEW SENT BY: lochs
REV RECEIVD BY: jochs
- BUILDING INSPECTOR REVIEW
C DATE: 04/06/06
DATE: 04/06/06 TIME: 16:26
DATE: 04/04/06 TIME: 08:25
CONT ID:
TIME SPENT:
SENT TO:
0.00
REVIEW NOTES:
2006-04-06 16:29:57 CONDITIONS OF PERMIT:
1 Basement bedroom window. sill heiaht
and exterior earess well to be to code.
IRC Section 310.
2 Smoke detectors throuahout entire hou
se oer attached handout. IRC Section
313.
3 Current code for insulation and
electrical receotacles for anv area
where wall covering is removed and
replaced.
4 Other items mav be noted durina
insoections due to comolex orolect and
un-exoected chanaes bv owner or
conditions encountered.
-------------------------------------------------------------------------------
CONDITIONAL
ENCOMPASS - Pentamation
permit.4ge (permit5.4g1)
RUN DATE:04/06/06
SMOKE ALARMS 2005
Section R313; smoke alarms.
Each smoke alarm shall be listed:
R313.2 Req~i~~dshlOke alarm locations. At least one smoke alarm shall be installed in each of the following locations:
1. In the living area remote from the kitchen and cooking appliances. Smoke alarms located within 20 feet horizontally of a
cooking appliance must incorporate a temporary silencing feature or be photoelectric type.
2. In each room designed for sleeping.
3. On the ceiling of the upper level near the top or above each stairway, other than a basement stairway, in any multistory
dwelling. The alarm shall be located so that smoke rising in the stairway cannot be prevented from reaching the alarm by an
intervening door or obstruction.
4. On the basement ceiling near the ~tairway.
R313.2.1 Alterations and additions. When interior alterations or additions requiring a permit occur,
OR when one or more sleeping rooms are added or created in existing dwellings, the individual dwelling
unit shall be provided with smoke alarms.
The Alarms shall be located in the same places as required for new dwelllngs. The smoke alarms
shall be interconnected and hard wired.
R313.5.2 Interconnection. Whenmore than one smoke alarm is required to be instaIledwithin an
individual dwelling unit, the alarm devices shall be interconnected in such a manner that the actuation of
one alarm will activate all of the alarms in the individual unit.
EXCEPTIONS:
1. Smoke alarms in existing areas shall not be required to meet the requirements where the alterations do not result in the removal
of the interior wall or ceiling finishes exposing the structure unless, there is an attic, crawlspace, or basement available that
could provide access for hard wiring and interconnection without the removal of interior finishes.
Repairs -are exempt from the requirements of this section.
R3l3.3 Prohibited smoke alarm locations. A smoke alarm requited under this section shall not be placed:
1. Within 3 feet horizontally fi'om any grille moving conditioned air within the living space or,
2. In any location or environment that is prohibited by the terms of the listing.
R313.4 Mounting requirements. Smoke alarms according to their listing installation instructions and the requirements of this
section.
R313.4.! Flat Ceilings. In rooms with flat, peaked sloping or single slope ceilings with a slope ofless than 1.5/12, smoke alarms
shaH. be mounted either:
1. On the ceiliog at least 4 inches from each wall; or
2.. On a wall with the top of the alarm not less than 4 inches below the ceiling and not farther from the ceiling than 12 inches or
the distance from the ceiling specified in the smo.ke alarm manufacture's listing and installation instructions, whichever is less.
R313.4.2 Peaked Sloping Ceilings. In rooms with peaked sloping ceilings with a slope of 1.5/12 or greater, smoke alarms shall
be:
1. Mounted on the ceiling or wall within 3 feet measured horizontaqy, from the peak of the ceiling;
2. At least 4 inches measured vertically, below the peak of the ceiling; and
3. At least 4 inches from any projecting structural element.
R3l3.4.3 Single Slope Ceilings. In rooms with single slope ceilings with a slope of 1.5/12 or greater. smoke alarms shall be:
I. Mounted on the ceiling or wall within 3 feet measured horizontally. of the high point of the ceiling; and
2. Not closer than 4 inches from any adjoining wall surfaces or any projecting structural element.
R313.4.4, 313.4.1, 313.3.2 Visible and tactile notification appliances. SEE CODE.
R313.5 Connection to Power Source. Each smoke alarm shall be powered from:
I. The electrical system of the home as the primary power source and a battery as a secondary power
source; or
2. A battery rated for a 10 year life, provided the smoke alarm is listed for use with a 10 year battery.
R313.5.! Circuitry. Eacb smoke alarm whose primary power source is the home electrical system shall be mounted on an
electrical outlet box and be connected by a permanent wiring method to a general branch circuit.
PERMIT PLAN REVIEW STOPS
PAGE 1
PERMIT NUMBER:
PARCEL ID
PARCEL ADDRS
APPLY DATE
CONTRACTOR
PHONE NUNBER
06040006 - TAYLOR
1713030004028000
10678 WINTERWOOD DR CARMEL.
04/03/06 ISSUE DATE
HAMILTON HOMES
(317) 570-1331
TYPE: RESREMODEL
IN 46032
C/O DATE
FAX NUMBER (317) 570-144
-------------------------------------------------------------------------------
REVIEW STOP: BLDG - BUILDING INSPECTOR REVIEW
REV NO: 1 STATUS: C DATE: 04/06/06 CONT
REVIEW SENT BY: lochs DATE: 04/06/06 TIME: 16:26 TIME
REV RECEIVD BY: jochs DATE: 04/04/06 TIME: 08:25 SENT
REVIEW NOTES: 2006-04-06 16:29:57 CONDITIONS OF PERMIT:
1 Basement bedroom window.
and exterior earess well to
IRC Section 310.
TD:
SPENT:
TO:
0.00
sill heiaht
be to code.
2 Smoke detectors throuahout entire hou
se per attached handout. IRC Section
313.
3 Current code for insulation and
electrical receptacles for anv area
where wall covering is removed and
replaced.
4 Other items mav be noted durina
inspections due to complex prolect and
un-expected chanaes bv owner or
conditions encountered.
----------~~-------------------------------------------------------------------
CONDITIONAL
ENCOMPASS - Pentamation
permit.4ge (permit5.4gl)
RUN DATE:04/06/06