A0.01 Foundation - Basement
\A1;19'-8{\H0.75x;\S1#2;}" \A1;19'-1{\H0.75x;\S1#2;}" \A1;11'-9" \A1;2'-0"\A1;4'-0" \A1;60'-7" OVERALL SUMP w/ CHECK VALVE, VERIFY LOCATIONOPT. EJECTOR PIT AND PUMP AS REQUIRED, VERIFY LOCATION \A1;4'-9{\H0.75x;\S1#2;}" \A1;19'-10" \A1;13'-9{\H0.75x;\S1#2;}" \A1;16'-4{\H0.75x;\S1#2;}" \A1;5'-4"\A1;1'-9{\H0.75x;\S1#2;}" 123456789 UP 15 RISERSHANDRAIL, PER CODE ADD RISER W/ OPT. 9'-0" POUR FURNACE PER MECHANICAL PLANSOPT. WATER SOFTENER, PER SPEC.WATER HEATER, PER SPEC RADON VENT PER CODE, VERIFY LOCATION \A1;3'-10{\H0.75x;\S1#2;}"\A1;21'-9" POST & BEAM PER STRUCTURAL PLANS POST & BEAM PER STRUCTURAL PLANS \A1;7'-2{\H0.75x;\S1#2;}"\A1;29'-4{\H0.75x;\S1#2;}" PROVIDE SEPARATION BETWEEN WATER & SEWER LINES, PER CODE POST & BEAM PER STRUCTURAL PLANS \A1;4'-6"\A1;8'-0" \A1;20'-3{\H0.75x;\S1#2;}" \A1;60'-7" OVERALL \A1;20'-0" \A1;1'-10{\H0.75x;\S1#2;}" \A1;16'-3" \A1;1'-10{\H0.75x;\S1#2;}" \A1;2'-0" \A1;10'-3{\H0.75x;\S1#2;}" \A1;1'-2" \A1;8'-3" \A1;10{\H0.75x;\S1#2;}" \A1;54'-9{\H0.75x;\S1#2;}" OVERALL\A1;36'-3{\H0.75x;\S1#2;}" \A1;32'-6"\A1;54'-9{\H0.75x;\S1#2;}" OVERALL \A1;7'-4{\H0.75x;\S1#2;}" \A1;12'-0" \A1;11'-7" \A1;18'-8{\H0.75x;\S1#2;}" \A1;11'-7" \A1;10'-0" \A1;11'-4" LINE OF CANTILEVERED\PBAY. \A1;1'-0" \A1;1'-0"\A1;7'-4{\H0.75x;\S1#2;}" \A1;9'-10"\A1;10'-2{\H0.75x;\S1#2;}"LEAD WALL PAST OVERDIG, FIELD VERIFY LOCATION\P(TYP.) 4140 SL & EGRESS WELL #3, AS REQUIRED\PBY CODE\PSEE STRUCTURAL DETAILS \A1;2'-0" \A1;2'-0" \A1;6'-2" \A1;6'-6{\H0.75x;\S1#2;}" \A1;2'-0" \A1;2'-0"\PTYP. \A1;PROVIDE FDN LEDGE AS NEEDED FOR NATURAL STONE \A1;18'-8{\H0.75x;\S1#2;}" \A1;2'-7{\H0.75x;\S1#2;}" \A1;3'-0" \A1;2'-8{\H0.75x;\S1#2;}" FLOOR DRAIN, \PVERIFY LOCATION \A1;24'-10" SLOPE 3A2 B.3 CONCRETE SLABUNEXCAVATED(SEE STRUCTURAL PLANS)BASEMENT - UNFINISHEDSLAB (SEE STRUCTURAL PLANS)CONCRETE SLABUNEXCAVATED(SEE STRUCTURAL PLANS) 2A2 B.2 1A2 B.11A2 B.1 2A2 B.2 3A2 B.3 \A1;4'-6"\A1;8'-0" \A1;20'-3{\H0.75x;\S1#2;}" \A1;60'-7" OVERALL \A1;20'-0" \A1;1'-10{\H0.75x;\S1#2;}" \A1;16'-3" \A1;1'-10{\H0.75x;\S1#2;}" \A1;2'-0" \A1;10'-3{\H0.75x;\S1#2;}" \A1;1'-2" \A1;8'-3" \A1;10{\H0.75x;\S1#2;}" \A1;54'-9{\H0.75x;\S1#2;}" OVERALL\A1;36'-3{\H0.75x;\S1#2;}" \A1;32'-6"\A1;54'-9{\H0.75x;\S1#2;}" OVERALL \A1;7'-4{\H0.75x;\S1#2;}" \A1;12'-0" \A1;11'-7" \A1;18'-8{\H0.75x;\S1#2;}" \A1;11'-7" \A1;10'-0" \A1;1'-0" \A1;1'-0" \A1;9'-10"\A1;10'-2{\H0.75x;\S1#2;}"LEAD WALL PAST OVERDIG, FIELD VERIFY LOCATION\P(TYP.) \A1;PROVIDE FDN LEDGE AS NEEDED FOR NATURAL STONE \A1;24'-10" A0.01 FOUNDATION - BASEMENTMidwest Zone Office1900 Golf Road - Suite 300Schaumburg, Illinois 60173(c) Copyright 2019 PulteGroup, Inc. PRODUCT MANAGERRick StarkeyVERSION RELEASEDATE:05/10/2019 PROJECT TYPE Single Family SHEET PLAN NAME SPECIFICATION LEVEL NPC CHILD NUMBER ---- Woodside 2312.300Home for * Market Home *, 7774-00600#314503 Mauldin St., Carmel, IN 46074BASEMENT FOUNDATION PLANSCALE: 1/4" = 1'-0" (HALF SCALE ON 11x17 PAPER) Alternate Sump Location 08/22/22