HomeMy WebLinkAboutM101.0NLEGRAND
SCREWLESS
COVER PLATE -
BLACK
TOGGLE
SWITCH
WHITE
REFRIGERATOR OUTLET
MICROWAVE OUTLET
DISHWASHER POWER SUPPLY
HOOD VENT POWER SUPPLY
GARBAGE DISPOSAL POWER
SUPPLYCOOKTOP POWER SUPPLY
CLOTHES DRYER OUTLET
CLOTHES WASHER OUTLET
110V OUTLET
220/240V OUTLET
GFCI OUTLET
OUTDOOR OUTLET
LOW VOLTAGE TRANSFORMER
SINGLE POLE
SWITCHDIMMER SWITCH
3-WAY
SWITCH4-WAY
SWITCHGD WALL SWITCH
GD COUNTERTOP AIR SWITCH
LOW VOLTAGE LIGHTING SWITCH
TIMER SWITCH
OCCUPANCY
SWITCHSURFACE MOUNT LIGHT FIXTURE
4" RECESSED CAN LIGHT
6" RECESSED CAN LIGHT
6" RECESSED CAN/FAN UNIT
EXHAUST FAN
ONLYEXHAUST FAN W/ LIGHT
WALL MOUNTED SCONCE / LIGHT
CEILING FAN
LOW VOLTAGE LIGHT
SMOKE DETECTOR
CARBON MONOXIDE DETECTOR
SMOKE/CARBON
MONOXIDEMOTION SENSOR
CEILING
SPEAKER
GAS SHUT-OFF KEY
MAIN WATER SHUT-OFF
LAUNDRY BOX
FROST PROOF HOSE BIB
CLEAN OUT
TILE-IN DRAIN
FLOOR DRAIN
COLD AIR RETURN
FLOOR FLOOR SUPPLY REGISTER
CEILIN
G CEILING SUPPLY REGISTER
WALL WALL SUPPLY REGISTER
EXTERIOR WALL EXHAUST VENT
T THERMOSTAT
DRYER BOX
ELECTRICAL KEY
PLUMBING KEY
HVAC KEY
6" 3000K
MODEL NO.
6RLD G3
07LM 30K
90CRI 120
FRPC WWH
M6
DECORA
WHITE
GFCI WHITE
UP
UP
UP
FLOOR FLOOR
FLOOR
R
R OC
R
R
R
R
R
R LAUNDRY
C.H. 8'-11"
TILE
71 SQ. FT.
LV1LV1E6E6
E8E8
E10E10
P2P2
P3P3
P1P1
MUD ROOM
C.H. 8'-11 3/4"
TILE
95 SQ. FT.
PANTRY
C.H. 8'-11 3/4" AFF
HARDWOOD
29 SQ. FT.
POWDER
C.H. 8'-11"
TILE
20 SQ. FT.
ENTRY
KITCHEN/SUNROOM
DINING
GREAT ROOM
LANDING
STUDY
HALL POWDER
CLOSET
MUSIC ROOM
C.H.: VARIES
WOOD PLANK
234 SQ. FT.
C.H. 9'-1"
WOOD PLANK
731 SQ. FT.
C.H. 9'-1"
WOOD PLANK
278 SQ. FT.
WOOD PLANK
461 SQ. FT.
WOOD PLANK
115 SQ. FT.
WOOD PLANK
243 SQ. FT.
WOOD PLANK
52 SQ. FT.
WOOD PLANK
14 SQ. FT.
WOOD PLANK
238 SQ. FT.
E11E11
E10E10
E5E5
E5E5
E5E5
TO KITCHEN DOWNLIGHTS
E13E13
E11E11
E11E11
E7E7
E12E12
E9E9
FLOOR FLOOR
FLOOR
R
R OC
R
RLAUNDRY
C.H. 8'-11"
TILE
71 SQ. FT.
LV1LV1E6E6
E8E8E5E5
E10E10
P2P2
P1P1
MUD ROOM
C.H. 8'-11 3/4"
TILE
95 SQ. FT.
PANTRY
C.H. 8'-11 3/4" AFF
HARDWOOD
29 SQ. FT.
POWDER
C.H. 8'-11"
TILE
20 SQ. FT.
E10E10
E5E5
E5E5
E5E5
TO KITCHEN DOWNLIGHTS
E7E7
E9E9
PROPOSED ELECTRICAL PLAN NOTES
NOTE QTY DESCRIPTION
1 ALL NEW FIXTURES AND DEVICES SHOWN TO BE PROVIDED
BY ELECTRICIAN U.N.O.
1
VERIFY EXISTING SMOKE AND CO DETECTORS MEET
CURRENT CODE REQUIREMENTS. HOMEOWNERS
UNDERSTAND THAT IF EXISTING FIXTURES NEED TO BE
BROUGHT UP TO CODE, THERE WILL BE AN ADDITIONAL
COST. THIS WILL BE DETERMINED ON A FIELD WALK.
1 VERIFY ALL INSTALLED GFCI OUTLETS MEET CURRENT
CODE REQUIREMENTS.
1
VERIFY EXISTING PANEL SIZING WILL SUPPORT PROPOSED
ELECTRICAL. HOMEOWNERS UNDERSTAND IF THE PANEL
NEEDS TO BE UPDATED, THERE WILL BE AN ADDITIONAL
COST.
4
PROVIDE ROUGH IN AND FINISH FOR (8) OUTLETS IN NEW
LOCATIONS AS SHOWN. DEVICE STYLE AND COLOR
SHOWN. ALL OUTLETS TO BE AT COUNTER HEIGHT. ALL
DEVICES TO BE STANDARD OUTLETS U.N.O.
1 PROVIDE FINISH FOR (2) (6") LED TRIMS IN EXISTING
HOUSINGS LOCATIONS.
1
PROVIDE ROUGH-IN AND INSTALL FOR NEW IN-CABINET
OUTLETS AS SHOWN. DEVICE COLOR AND FINISH AS
SHOWN. FINAL LOCATION TO BE DETERMINED BY FINAL
CABINET DRAWINGS.
1
PROVIDE ROUGH IN AND FINISH FOR NEW CEILING MOUNT
FIXTURES IN LOCATIONS SHOWN. FINAL HEIGHT OF
FIXTURE TO BE DETERMINED ON SITE DURING ROUGH IN
PHASE. FIXTURES TO BE PROVIDED BY CUSTOM LIVING.
HOMEOWNERS UNDERSTAND THE TYPE OF FIXTURE
SELECTED MAY HAVE AN EFFECT ON INSTALLATION COST.
1
INSTALL NEW FLUSH MOUNT CEILING FIXTURE ON
EXISTING LOCATION. FIXTURE TO BE PROVIDED BY
CUSTOM LIVING. HOMEOWNERS UNDERSTAND THE TYPE
OF FIXTURE SELECTED MAY HAVE AN EFFECT ON
INSTALLATION COST.
2
REPLACE EXISTING OUTLETS WITH NEW DEVICES TO
MATCH NEW DEVICE STYLE. ALL NEW DEVICES TO BE
STANDARD OUTLETS UNLESS NOTED OTHERWISE.
3
INSTALL NEW CHANDELIER FIXTURES IN EXISTING
LOCATIONS. FIXTURES TO BE PROVIDED BY CUSTOM
LIVING.
1 PROVIDE ROUGH-IN AND FINISH FOR NEW TOGGLE
SWITCH.
1
PROVIDE ROUGH IN AND FINISH FOR NEW CEILING MOUNT
FIXTURE IN LOCATION SHOWN. FINAL HEIGHT OF FIXTURE
TO BE DETERMINED ON SITE DURING ROUGH IN PHASE.
FIXTURES TO BE PROVIDED BY CUSTOM LIVING.
HOMEOWNERS UNDERSTAND THE TYPE OF FIXTURE
SELECTED MAY HAVE AN EFFECT ON INSTALLATION COST.
E1E1
E2E2
E3E3
E4E4
E5E5
E6E6
E7E7
E8E8
E9E9
E10E10
E11E11
E12E12
E13E13
E1E1
E2E2
E3E3
E4E4
E5E5
E6E6
E7E7
E8E8
E9E9
E10E10
E11E11
E12E12
E13E13
PROPOSED LOW VOLTAGE PLAN NOTES
NOTE QTY DESCRIPTION
1
PROVIDE ROUGH IN AND FINISH FOR LOW VOLTAGE
DRIVER, OCCUPANCY SENSOR, AND UNDER CABINET
LIGHTING IN MUDROOM AS SHOWN. FIXTURES TO BE
PROVIDED BY CUSTOM LIVING.
LV1LV1LV1LV1
PROPOSED PLUMBING PLAN NOTES
NOTE QTY DESCRIPTION
1 REINSTALL EXISTING TOILET ON EXISTING LOCATION AS
SHOWN.
1 PROVIDE ROUGH IN AND FINISH FOR NEW SINK AND
FAUCET IN NEW LOCATION AS SHOWN.
1
PROVIDE FINISH FOR NEW TOILET IN EXISTING LOCATION
AS SHOWN ON PRINTS. PROVIDE NEW SHUT OFF VALVES
ON FINISH.
P1P1
P2P2
P3P3
P1P1
P2P2
P3P3 PORTER RESIDENCEFLOORING, MUDROOM, PANTRY12257 MontcalmCarmel, IN 46032Date:Revision:
A5
SHEET OF 11
SIGNATURE / SEAL
Client Initials:
Date:
The plans, including all text, drawings, concepts, and ideas
forming a part of the plans and the selection and arrangement
thereof are Copyright 2018 of Custom Living, Inc., Indianapolis,
IN. ALL RIGHTS RESERVED. The plans shall remain the
property of Custom Living Inc. Any use of the plans or their
content without the prior written permission of Custom Living Inc.
is strictly prohibited. CUSTOM LIVING5335 Winthrop AveIndianapolis IN 462208/19/2022
DATE:
[PRINTS TO SCALE IF PRINTED ON 24" X 36" ]
FIRST FLOOR PROPOSED M.E.P. PLAN
SCALE: SEE DRAWING
NEW OUTLET DEVICE STYLE
NEW SWITCH DEVICE STYLE (E11)
RECESSED CAN LIGHTS
DECORATIVE LIGHT FIXTURES
UNDER CABINET LIGHTING (LV1)
CHANDELIER
(E10)
FIRST FLOOR
SCALE: 3/16" = 1'
PANTRY, MUDROOM, POWDER AND LAUNDRY
SCALE: 1/2" = 1'
IN-
CABINET
OUTLET
(E9)
FLUSH MOUNT
MUDROOM (E8)
FLUSH MOUNT
PANTRY (E9)
FLUSH MOUNT
OFFICE (E13)
GENERAL M.E.P NOTES
HVAC Contractor is responsible for engineering calculation
necessary for correct sizing of new equipment and
ductwork being supplied, fabricated and installed for the
project.
HVAC ductwork installed in unconditioned areas to be
insulated and sealed per Building Code Standards.
HVAC contractor to start, test, and balance any new
equipment and ductwork to assure proper operation of
new systems.
Final plumbing materials selected may have an affect on
the final Plumbing Material and Installation Budgets.
Owners understand that if additional plumbing, electrical or
ductwork is found in walls being deleted that is not
included on the plans there will be a Change Order during
construction to relocate as necessary.
Owners understand that during mechanical rough-ins there
will be times when the water service will be shut off to
areas in the home.
Plumbing and Lighting fixtures supplied by Owner will not
be warranted by Custom Living
Plumbing and Lighting fixtures supplied by Owner must be
selected and on-site prior to start of mechanical rough-ins.
08/23/22