HomeMy WebLinkAboutA101 - PROPOSED FLOOR PLANHB15'-10 1/2"16'-0 5/8"2'-4"7'
4'-1"4'-6"4'-6"4'-1"16'-0 5/8"6'-3 3/4"NEW STAMPED
CONCRETE PATIO
NEW WINDOW
WELL
NEW WINDOW
WELL
GAS FIREPLACE
NEW CLAD WOOD
WINDOWS BETWEEN
EXISTING POSTS
EXISTING PORCH
NEW CEILING & TILE FLOORING
GARAGE
EXISTING
LANDSCAPE
BED
FURNISH & INSTALL (1) 36"W X 80"H FULL-GLASS FIBE
OUTSWING EXTERIOR DOOR W/ LOCKING HARDWAR
ON PLAN.
FURNISH & INSTALL NEW 1X ROUGH-SAWN CEDAR T
INTERIOR & EXTERIOR OF NEW DOOR & WINDOWS.
FURNISH & INSTALL 1X6 PINE TONGUE & GROOVE CE
PORCH.
FURNISH & INSTALL (2) NEW 54" X 49" RECTANGULAR
PREFABRICATED WINDOW WELLS AT BASEMENT WIN
SHOWN ON PLAN W/ GRAVEL BASE AT BOTTOM OF W
EDGE OF WINDOW WELL UNITS TO SIT 4" ABOVE GRA
FURNISH & INSTALL 4" CMU CURB AT OUTER PERIME
WINDOW WELL TO ALIGN W/ TOP EDGE OF WELL UNI
FURNISH & INSTALL CONCRETE FOOTING TO FROST
NEW OUTDOOR FIREPLACE STRUCTURE.
FURNISH & INSTALL COLORED STAMPED CONCRETE
GRADE AS SHOWN ON PLAN.
FURNISH & INSTALL GALVANIZED STEEL STUD FRAM
CEMENT BOARD FOR NEW OUTDOOR GAS FIREPLAC
STRUCTURE ON NEW CONCRETE FOOTING.
NEW OUTDOOR GAS FIREPLACE APPLIANCE TO BE
INSTALLED BY OTHERS.
INSTALLATION.
FURNISH & INSTALL NATURAL STONE VENEER AT ALL
NEW FIREPLACE STRUCTURE & EXPOSED OUTER SI
WINDOW WELL CURBS.
FURNISH & INSTALL 2-1/4" LIMESTONE CAPS W/ SMO
AT NEW FIREPLACE STRUCTURE & WINDOW WELL C
FURNISH & INSTALL POWDER-COATED ALUMINUM RA
NEW WINDOW WELL LIMESTONE CAPS.
REBUILD REAR-FACING FENCE & GATE AT BACK COR
GARAGE (NOT SHOWN ON PLAN) WHERE REMOVED
CONSTRUCTION ACCESS TO MATCH EXISTING DETA
CLOSELY AS POSSIBLE.
PATCH & PAINT DRYWALL IN GARAGE AS NECESSARY
ELECTRICAL MODIFICATIONS.
PREP & PAINT EXPOSED CONCRETE FOUNDATION W
HOUSE & GARAGE FACING NEW PATIO AREA.
PREP & PAINT NEW TRIM MATERIALS AT PORCH WAL
STAIN NEW TONGUE & GROOVE PORCH CEILING.
PROPOSED PLAN NOTES:
FURNISH & INSTALL NEW BURIED GAS LINE FROM GAS METER TO
NEW OUTDOOR GAS FIREPLACE.
FURNISH & INSTALL 12X24 PORCELAIN TILE IN HALF-BRICK LAY
PATTERN ON EXISTING PORCH CONCRETE SLAB.
FURNISH & INSTALL NEW STUD FRAMING BETWEEN EXISTING
PORCH POSTS FOR NEW WINDOW & DOOR OPENINGS.
FURNISH & INSTALL (3) 39-1/2"W X 71-1/2"H CLAD WOOD DOUBLE-
HUNG WINDOWS IN EXTERIOR WALL OF PORCH. SEE ELEVATIONS
FOR DETAIL.
FURNISH & INSTALL (4) 39-1/2"W X 32"H CLAD WOOD FIXED
TRANSOM WINDOWS IN EXTERIOR WALL OF PORCH. SEE
ELEVATIONS FOR DETAIL.
FURNISH & INSTALL (1) 36"W X 80"H FULL-GLASS FIBERGLASS
OUTSWING EXTERIOR DOOR W/ LOCKING HARDWARE AS SHOWN
ON PLAN.
FURNISH & INSTALL NEW 1X ROUGH-SAWN CEDAR TRIM AT
INTERIOR & EXTERIOR OF NEW DOOR & WINDOWS.
FURNISH & INSTALL 1X6 PINE TONGUE & GROOVE CEILING IN
PORCH.
FURNISH & INSTALL (2) NEW 54" X 49" RECTANGULAR
PREFABRICATED WINDOW WELLS AT BASEMENT WINDOWS AS
SHOWN ON PLAN W/ GRAVEL BASE AT BOTTOM OF WELLS. TOP
EDGE OF WINDOW WELL UNITS TO SIT 4" ABOVE GRADE.
FURNISH & INSTALL 4" CMU CURB AT OUTER PERIMETER OF EACH
WINDOW WELL TO ALIGN W/ TOP EDGE OF WELL UNIT.
FURNISH & INSTALL CONCRETE FOOTING TO FROST DEPTH FOR
NEW OUTDOOR FIREPLACE STRUCTURE.
FURNISH & INSTALL COLORED STAMPED CONCRETE PATIO ON
GRADE AS SHOWN ON PLAN.
FURNISH & INSTALL GALVANIZED STEEL STUD FRAMING W/ 1/2"
CEMENT BOARD FOR NEW OUTDOOR GAS FIREPLACE
STRUCTURE ON NEW CONCRETE FOOTING.
NEW OUTDOOR GAS FIREPLACE APPLIANCE TO BE PROVIDED &
INSTALLED BY OTHERS. CASE TO MANAGE SCHEDULING OF
INSTALLATION.
FURNISH & INSTALL NATURAL STONE VENEER AT ALL SIDES OF
NEW FIREPLACE STRUCTURE & EXPOSED OUTER SIDES OF
WINDOW WELL CURBS.
FURNISH & INSTALL 2-1/4" LIMESTONE CAPS W/ SMOOTH EDGES
AT NEW FIREPLACE STRUCTURE & WINDOW WELL CURBS.
FURNISH & INSTALL POWDER-COATED ALUMINUM RAILINGS AT
NEW WINDOW WELL LIMESTONE CAPS.
REBUILD REAR-FACING FENCE & GATE AT BACK CORNER OF
GARAGE (NOT SHOWN ON PLAN) WHERE REMOVED FOR
CONSTRUCTION ACCESS TO MATCH EXISTING DETAILS AS
CLOSELY AS POSSIBLE.
PATCH & PAINT DRYWALL IN GARAGE AS NECESSARY FROM
ELECTRICAL MODIFICATIONS.
PREP & PAINT EXPOSED CONCRETE FOUNDATION WALLS OF
HOUSE & GARAGE FACING NEW PATIO AREA.
PREP & PAINT NEW TRIM MATERIALS AT PORCH WALL.
STAIN NEW TONGUE & GROOVE PORCH CEILING.
CONSTRUCTION
#0
ISSUE DATE:
2022-08-24
REV:
www.caseindy.com
99 E. Carmel Drive, Suite 100
Carmel, Indiana 46032
317.846.2600 317.846.2601(f)
These drawings have been prepared
by Case Design & Remodeling solely
for its use and should not be
reproduced or relied upon by any
other parties. Dimensions shown or
scaled are subject to change per
actual job condition and must be
verified. Materials are to be supplied
as specified as equal or standardwhen not uniquely specified. Installed
materials may vary in appearance
from drawings. Reference
manufacturer's product data for actual
appearance and specifications.MOORE RESIDENCEOUTDOOR LIVINGCRAIG & REBECCA MOORE12629 MALCOMBE STREETCARMEL, INDIANA 46032Approved By:
Date:
A101
Jordan Stocklin
Designer
jstocklin@caseindy.com
262590174
JOB NUMBER:
PROPOSED FLOOR PLAN
SCALE: 1/4" = 1'
Dawn Ashburn
Project Developer
dashburn@caseindy.com
09/06/22