Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A301 Wall Sections
Second Floor 913' - 1" First Floor 903' - 0" Roof 922' - 2" Basement 893' - 6 1/2" Garage 900' - 0"Laundry 003 Breakfast 117 Great Room 114 Bedroom 211 6" 12" A301 1 Second Floor 913' - 1" First Floor 903' - 0" Roof 922' - 2" Basement 893' - 6 1/2" Garage 900' - 0" Composition shingles over 15# felt over 1/2" OSB w/clips 3/4" T&G over 11.25" TJIs @ 12" OC 3/4" T&G over 11.25" TJIs @ 12" OC Air gap and baffel Batt insulation R-49 Perforated soffit vent EIFS over Tyvek over 1/2" plywood sheathing over 2x6s @ 16" OC over 1/2" GWB 1/2" GWB 1/2" GWB Simpson hurricane clip 5.5" Batt insulation, R-20 Outside air film Shingled roof Air space Fiberglass insulation Inside air film R value U value 0.17 0.61 1.10 49.0 0.68 51.56 0.0196 Roof R Value Outside air film Sheathing 5.5" Batt insulation Air space 5/8" GWB R value U value 0.17 0.61 21.0 2.1 0.55 24.43 0.043 Wall R Value 12" Anchor bolt w/ 2" Hook @ 24" OC 8" CMU 12" CMU Waterproofing EIFS - Stone EIFS - Limestone cap DATE: 56 Milford Drive, Suite 2 Hudson, Ohio 44236 (330) 653-5320 V (330) 653-3520 F don@connectingspaces.com www.connectingspaces.com A301Hanna HouseNew HouseE 166th StZionsville INBuliding Sections 5/31/22 0 Scale 4' 8'16' 1/8" = 1'-0" Cross Section3 0 Scale 1' 2'4' 1/2" =1'-0" Exterior Wall Section1 Trusses @ 2'-0" OC 09/06/22