HomeMy WebLinkAboutC500 Sanitary PnPLEGEND = EXISTING STORM SEWER LINE = SWALE = EXISTING SANITARY SEWER LINE = PROPOSED SANITARY SEWER LINE = PROPOSED STORM SEWER LINE = SANITARY SEWER MANHOLE = STORM MANHOLE = STORM INLET = SOLID WALL UNDERDRAIN SSD = SUBSURFACE DRAIN U.E. TOC INV. RCP M.H. STR. D.&U.E. M.E. PROP. TYP. R. EX. S.S.E. = TOP OF CASTING = INVERT = REINFORCED CONCRETE PIPE = MANHOLE = STRUCTURE = DRAINAGE AND UTILITY EASEMENT = UTILITY EASEMENT = SANITARY SEWER EASEMENT = MATCH EXISTING GRADE = TYPICAL = PROPOSED = EXISTING = RADIUS = VARIABLE WIDTHV.W. = BUILDING SETBACK LINE (B.S.L.) = EASEMENT ROW = RIGHT-OF-WAY CL = CENTERLINE PVC = POLYVINYL CHLORIDE PIPE B-B = BACK TO BACK (CURB) = SUBSURFACE DRAIN AND SUMP LINE = EXISTING SUBSURFACE DRAIN W W W W W W W W W W 80 79 78 7776 75 71 68 SANNER COURT (PRIVATE STREET)SANSANSANSANSANSANSAN825 830 835 840 845 850 855 825 830 835 840 845 850 855 FINISHED GRADE EXISTING GRADE PROFILE LEGEND CONTRACTOR MUST VERIFY INVERT INFORMATION PRIOR TO BEGINNING CONSTRUCTION. IF A DISCREPANCY EXISTS, CONTACT THE ENGINEER IMMEDIATELY. SANITARY SEWER STRUCTURE DATA TABLE STRUCTURE NUMBER RS-301 STRUCTURE TYPE 48'' DIA. MANHOLE TOP OF CASTING 844.52 CASTING TYPE R-1772 INVERT INV OUT = 837.00(W) SANITARY SEWER PIPE DATA TABLE UPSTREAM STRUCTURE RS-301 DOWNSTREAM STRUCTURE RS-204 SIZE 8" MATERIAL PVC LENGTH 202' SLOPE 1.00% Know what's below. before you dig.Call R SANITARY SEWER NOTES 1.THE CONTRACTOR SHALL CONTACT APPLICABLE UNDERGROUND-PLANT PROTECTION/LOCATION SERVICE AT LEAST 72 HOURS PRIOR TO ANY WORK. 2.THE CONTRACTOR SHALL CONTACT THE OWNER AND/OR ENGINEER IF UTILITIES APPEAR TO BE IN CONFLICT WITH THE PROPOSED IMPROVEMENTS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES WHICH CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THE PLANS. 3.THE PLANS SHOW THE LOCATION OF ALL KNOWN UTILITIES LOCATED WITHIN THE LIMITS OF CONSTRUCTION ACCORDING TO INFORMATION PROVIDED BY THE VARIOUS UTILITY COMPANIES, PREVIOUS CONSTRUCTION PLANS AND AS EVIDENCED BY OBSERVATION OF ABOVE GROUND CONDITIONS BY THE SURVEYOR. THE ACCURACY OF THIS INFORMATION IS NOT GUARANTEED. 4.THE LOCATION AND PROTECTION OF UTILITY STRUCTURES, THEIR SUPPORT AND MAINTENANCE DURING CONSTRUCTION IS THE EXPRESS RESPONSIBILITY OF THE CONTRACTOR. 5.THE CONTRACTOR SHALL CONTACT ALL APPLICABLE UTILITY OWNERS TO VERIFY ANY AND ALL FEES ASSOCIATED WITH THE INSTALLATION OF UTILITIES. 6.ALL CONSTRUCTION ON THIS SITE TO BE PERFORMED IN COMPLIANCE WITH O.S.H.A. STANDARDS FOR WORKER SAFETY. 7.ANY PART OF SANITARY TRENCHES RUNNING UNDER OR WITHIN 5' OF PAVEMENT TO BE BACKFILLED WITH GRANULAR MATERIAL. 8.IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY LOCATION, SIZE, AND ELEVATION OF EXISTING UTILITIES, STRUCTURES, PIPES, AND PAVEMENTS. AS RELATED TO THEIR WORK. NOTIFY ENGINEER OF ANY CONFLICT AND/OR DISCREPANCIES IN THE CONSTRUCTION DOCUMENTS. 9.CLEARANCE BETWEEN STORM / SANITARY SEWER SYSTEMS AND DOMESTIC/FIRE LINE SERVICE, SHALL BE MAINTAINED AT 10' HORIZONTAL AND 18" VERTICAL. 10.CONTRACTOR TO INSTALL CONCRETE CRADLES AT PIPE CROSSINGS WHEN THE VERTICAL SEPARATION AS MEASURED FROM THE EXTERIOR OF THE PIPES, BETWEEN SANITARY SEWERS, WATER MAINS AND STORM SEWERS IS 18" OR LESS. 11.IF ANY EXISTING STRUCTURES TO REMAIN ARE DAMAGED DURING CONSTRUCTION, IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO REPAIR AND/OR REPLACE THE EXISTING STRUCTURE AS NECESSARY TO RETURN IT TO IT'S CONDITION PRIOR TO CONSTRUCTION. 12.WHEN PERFORMING EXCAVATIONS DURING PERIODS OF WET WEATHER, PROVIDE ADEQUATE DEWATERING, DRAINAGE AND GROUND WATER MANAGEMENT TO CONTROL MOISTURE OF SOILS. 13.COMPACTED "B" BORROW BACK FILL REQUIRED OVER ALL UTILITIES IN PAVED AREAS. 14.ALL UTILITY STRUCTURES IN PAVED AREAS SHALL BE FLUSH WITH PAVEMENT AND SHALL HAVE TRAFFIC BEARING RINGS AND COVERS RATED FOR H20 LOADING. 15.FOLLOW ALL LOCAL AND STATE CODES IN REFERENCE TO SANITARY SEWER INSTALLATION. 16.SANITARY SEWER LATERALS SHALL BE BACKFILLED WITH GRANULAR MATERIAL FOR THE ENTIRE LENGTH OF THE PIPE. 17.ALL EXISTING MANHOLES SHALL BE ADJUSTED TO NEW FINISH GRADE ELEVATIONS. 18.CLEANOUTS ARE REQUIRED WITHIN 18-60 INCHES OF THE BUILDING AND EVERY 100 FEET ALONG THE LATERAL. 19.LATERALS STATIONS ARE FROM THE NEAREST DOWNSTREAM MANHOLE. 20.REFER TO ASTM D2321 FOR INSTALLATION OF PVC SANITARY SEWER. 21.ALL SANITARY SEWER TO HAVE DEFLECTION AND LEAKAGE TESTING AS PER CODE 327 IAC 3-6-19.C500 Sanitary PnPC500SANITARY PLAN & PROFILEW210497BCHW210497 01-13-2022DASJRV10 9abcd 8 7 6efgh109876 REVISIONS AND ISSUES5 4 3 2 1 PROJECT NO. SHEET NO.abcd5 4 3 2 CHECKED BY:DRAWN BY:DESIGNED BY:DWG NAME:PROJECT NO.:DATEBYeDATE:1 LOCATION: H:\2021\W210497\Engineering\design\conset\C500 Sanitary PnP.dwgLAYOUT: C500DATE/TIME: August 11, 2022 - 7:56amPLOTTED BY: HansenbfhgENGINEERS317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546 faxWEIHELand Surveying | Civil EngineeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild with confidence.SMPart of Section 11, Township 17 North, Range 3 East, Clay Township, Hamilton County, IndianaREVISED PER TAC COMMENTS05-13-2022TPG/BCHREVISED PER TRICO COMMENTS05-19-2022BCHREVISED PER TAC COMMENTS06-28-2022TPG/BCHREVISED PER TAC COMMENTS08-10-2022TPG/BCHSITE TBM TBM#1 SET ON THE EAST BOLT ON A FIRE HYDRANT AT THE BEGINNING OF THE CUL-DA-SAC ON THE NORTH SIDE OF SANNER COURT. ELEV. 841.80 (NAVD 88) TBM#2 SET ON THE RIM OF A SANITARY MANHOLE AT THE END OF THE CUL-DA-SAC OF SANNER COURT. ELEV. 842.89 (NAVD 88) W S N E 340 SANNER COURT, INDIANAPOLIS, IN 46290THE RESERVE AT SPRINGMILL, SECTION 2,REPLAT OF LOTS 68, 69C, 70C, & 71