E. ELEVATOR CAB FINISH FLOORING SHALL BE CARPET TILE AS SELECTED AND
FURNISHED BY THE OWNER.
F. ELEVATORS SHALL BE DEEMED AS MEETING LIFE SAFETY REQUIREMENTS
AND COMPLY WITH ACCESSIBLE MEANS OF EGRESS.
B. THE GENERAL CONTRACTOR SHALL COORDINATE ALL ITEMS, BUILDING
STRUCTURE, PENETRATIONS AND DIMENSIONS WITH THE ELEVATOR
EQUIPMENT SUPPLIER PRIOR TO CONSTRUCTION OF THE MASONRY
HOISTWAY SHAFTS.
C. ALL HOISTWAY DOORS ARE SINGLE SPEED UNLESS OTHERWISE NOTED.
D. DESIGNATED SUB-CONTRACTORS AND VENDORS SHALL NOT BE
PERMITTED TO USE THE ELEVATOR FOR CONSTRUCTION STAGING AND
DELIVERY OF MATERIALS DURING THE BUILDING CONSTRUCTION PERIOD.
ELEVATOR NOTES
A. ALL ELEVATORS SHALL BE CONSIDERED AS ACCESSIBLE
MEANS OF EGRESS AS DEFINED BY THE INDIANA BUILDING CODE SECTION
1007.4.
G. PROVISION OF EMERGENCY (STANDBY) POWER TO ELEVATORS IN
ACCORDANCE WITH THE INDIANA BUILDING CODE SECTION 1007.4 IS
REQUIRED. PROVIDE BATTERY BACK-UP POWER TO PERMIT LOWERING OF
THE CAB IN THE EVENT OF LOSS OF POWER. PROVIDE EMERGENCY
BATTERY LOWERING DEVICE ON ALL ELEVATORS.
H. ALL ELEVATOR SILLS SHALL BE ALUMINUM PROVIDED AND INSTALLED BY THE
ELEVATOR CONTRACTOR U.N.O. GROUTING OF THE SILLS ARE BY GENERAL
CONTRACTOR.
I. PROVIDE A 18"x18"x12" SUMP PUMP PIT AT BASE OF EACH ELEVATOR TO
ACCOMMODATE A PORTABLE SUMP PUMP. COORDINATE EXACT SIZE AND
PLACEMENT OF SUMP PIT w/ ELEVATOR SUPPLIER.
J. HOIST AND SAFETY BEAM SHALL BE FURNISHED AND INSTALLED BY THE
GENERAL CONTRACTOR.
K. PIT LADDER SHALL BE FURNISHED AND INSTALLED BY THE GENERAL
CONTRACTOR.architects and land planners6201 carrollton avenueIndianapolis, in 46220phone 317 202 0661fax 317 202 0662email office@weaversherman.comweaver sherman designADDENDUM 1
10/22/2021
OMIT HOISTWAY VENTING