HomeMy WebLinkAboutSite PlanSTOEPPELWERTH ® eea ALWAYS ON 7965 East 106th Street, Fishers, IN 46038-2505 phone:317.849.5935 fax:317.849.5942 (PIN) THE FOOTINGS FOR THIS HOUSE SHOULD BE PINNED SINCE THERE IS LITTLE OR NO TOLERANCE ON THE SIDE YARD AND BUILDING SETBACK LINE REQUIREMENT. CALL US WHEN FOOTING IS IN SO WE CAN SCHEDULE PINNING. 42 260't 40.2 T.C.=831.24 AS BUILT MH 38-70 846- � 845 , 845 63.4'/ 43.9 84, 842 843—, 844 \ D.&U.E. u) 20.50' *6" 6.00' 0 6 12.17b T csi N ro PATIO 1•12.6i. 0' 6M G 16.00' MODEL RESIDENCE n F.F.ELEV. =843.47� (SLAB) (LH) \ 00 M I N 00 mm I �r _1 O M 1 - � C4 (1 S STEP) \ "� �..I 842.55 o I m 42.8 2 0 8.17' 2.672 \ 3 24.67' POR � .67'h� 18' a CONC. 4 O d? 42.1 n DRIVE c' 5 L .51 36.9 ; 4' SW ,� / N \� —841 3 40.77 TA BUILT K N SI TON C 0 MH71 PLACE � 39.37 B40 4' S W W w I� AS SHOWN, THIS HOUSE WILL EXCEED THE MINIMUM REAR YARD SETBACK AND THE MAXIMUM LOT COVERAGE FOR R4 ZONING. THIS DRAWING IS TO BE USED AS AN EXHIBIT TO OBTAIN A VARIANCE TO THE ZONING REQUIREMENTS FOR THIS LOT. THIS DRAWING IS NOT TO BE USED FOR CONSTRUCTION UNTIL VARIANCE IS APPROVED. JOB ID 104482 CONTROL# 104482 CALD 13592 KENSINGTON PLACE CARMEL, IN 46032 1 It = 30' LOT AREA:5,554 Sq. Ft. LOT COVERAGE=51.87. DRIVE SLOPE=10.0% LEGEND: XX.X PROPOSED GRADE PER PLAN XX.XAB AS BUILT GRADE — _ S.S.D. _ — SUB -SURFACE DRAIN ASL SANITARY SEWER PSL 6" AS BUILT SANITARY LATERAL 6" PROPOSED SANITARY LATERAL W STORM SEWER 3/4" WATER CONNECTION o W WATER MAIN < SWALE • SANITARY MANHOLE #J STORM MANHOLE ■ CURB INLET FIRE HYDRANT D.&U.E. DRAINAGE & UTILITY EASEMENT B.L. BUILDING LINE W.M.E. WALL MAINTENANCE EASEMENT WATER AND SEWER LATERALS ARE SHOWN IN PROPOSED LOCATIONS. CONTRACTOR TO VERIFY LATERAL LOCATIONS PRIOR TO CONSTRUCTION. TOPOGRAPHY AND UTILITY LOCATIONS SHOWN SCALED FROM THE CITY OF CARMEL ENGINEERING GIS VIEWER. ACTUAL LOCATIONS AND TOPOGRAPHY WILL BE VERIFIED AT THE TIME THE HOUSE IS STAKED. A PLOT PLAN REVISION WILL FOLLOW. OS10�EPp G,\STEq.; 'o : No. _ 80040474 :`• _ STATE OF 0��' SU Rv �y L 0 T 2 2 B NOTE: THIS DRAWING IS NOT INTENDED TO BE REPRESENTED AS A RETRACEMENT OR ORIGINAL R E P L A T OF K E N S I N G TO N SBOUNDARY SURVEY, A URVEYOR LOCATION REP RTT SURVEY OR A 2ND REV PLACE R E P L A T 08/18/22M OVE CEJ HOUSE INSTR.#2012069761 1ST REV ADJUST HSE TO MEET COV 07/13/22 CEJ ZONING: R4 07/05/22 NSH/CEJ BENCHMARK 5' MINIMUM SIDE YARD :9•. TOP OF CASTING = 839.98 15' MINIMUM AGGREGATE 20' MINIMUM REAR YARD 50% MAXIMUM LOT COVERAGE 14wwCall bOorew. Call hefore you dig.