HomeMy WebLinkAboutSite PlanSTOEPPELWERTH
® eea ALWAYS ON
7965 East 106th Street, Fishers, IN 46038-2505
phone:317.849.5935 fax:317.849.5942
(PIN)
THE FOOTINGS FOR THIS HOUSE SHOULD BE PINNED
SINCE THERE IS LITTLE OR NO TOLERANCE ON THE SIDE
YARD AND BUILDING SETBACK LINE REQUIREMENT. CALL
US WHEN FOOTING IS IN SO WE CAN SCHEDULE PINNING.
42
260't
40.2
T.C.=831.24
AS BUILT
MH
38-70
846- � 845 ,
845 63.4'/ 43.9
84, 842 843—, 844 \
D.&U.E.
u) 20.50' *6"
6.00' 0
6 12.17b T
csi N ro PATIO 1•12.6i. 0' 6M G 16.00'
MODEL RESIDENCE
n F.F.ELEV. =843.47�
(SLAB) (LH) \ 00
M I N 00 mm I �r _1
O M 1 - � C4
(1 S STEP) \ "� �..I
842.55 o I m 42.8
2 0 8.17' 2.672
\ 3
24.67' POR � .67'h�
18' a
CONC. 4 O d? 42.1 n
DRIVE c'
5 L
.51 36.9 ; 4' SW ,� /
N \� —841 3
40.77
TA BUILT K N SI TON
C 0 MH71 PLACE
� 39.37
B40
4' S W W w
I�
AS SHOWN, THIS HOUSE WILL EXCEED THE MINIMUM REAR
YARD SETBACK AND THE MAXIMUM LOT COVERAGE FOR R4
ZONING. THIS DRAWING IS TO BE USED AS AN EXHIBIT TO
OBTAIN A VARIANCE TO THE ZONING REQUIREMENTS FOR
THIS LOT. THIS DRAWING IS NOT TO BE USED FOR
CONSTRUCTION UNTIL VARIANCE IS APPROVED.
JOB ID 104482
CONTROL# 104482 CALD
13592 KENSINGTON PLACE
CARMEL, IN 46032
1 It = 30'
LOT AREA:5,554 Sq. Ft.
LOT COVERAGE=51.87.
DRIVE SLOPE=10.0%
LEGEND:
XX.X PROPOSED GRADE PER PLAN
XX.XAB AS BUILT GRADE
— _ S.S.D. _ — SUB -SURFACE DRAIN
ASL SANITARY SEWER
PSL 6" AS BUILT SANITARY LATERAL
6" PROPOSED SANITARY LATERAL
W STORM SEWER
3/4" WATER CONNECTION
o W WATER MAIN <
SWALE
• SANITARY MANHOLE
#J STORM MANHOLE
■ CURB INLET
FIRE HYDRANT
D.&U.E. DRAINAGE & UTILITY EASEMENT
B.L. BUILDING LINE
W.M.E. WALL MAINTENANCE EASEMENT
WATER AND SEWER LATERALS ARE
SHOWN IN PROPOSED LOCATIONS.
CONTRACTOR TO VERIFY LATERAL
LOCATIONS PRIOR TO CONSTRUCTION.
TOPOGRAPHY AND UTILITY LOCATIONS
SHOWN SCALED FROM THE CITY OF
CARMEL ENGINEERING GIS VIEWER.
ACTUAL LOCATIONS AND TOPOGRAPHY
WILL BE VERIFIED AT THE TIME THE
HOUSE IS STAKED. A PLOT PLAN
REVISION WILL FOLLOW.
OS10�EPp
G,\STEq.;
'o : No.
_ 80040474 :`• _
STATE OF
0��'
SU Rv �y
L 0 T 2 2 B NOTE: THIS DRAWING IS NOT INTENDED TO BE
REPRESENTED AS A RETRACEMENT OR ORIGINAL
R E P L A T OF K E N S I N G TO N SBOUNDARY SURVEY, A
URVEYOR LOCATION REP RTT SURVEY OR A
2ND REV
PLACE R E P L A T 08/18/22M OVE CEJ HOUSE
INSTR.#2012069761 1ST REV ADJUST HSE TO MEET COV
07/13/22 CEJ
ZONING: R4 07/05/22 NSH/CEJ
BENCHMARK 5' MINIMUM SIDE YARD :9•.
TOP OF CASTING = 839.98 15' MINIMUM AGGREGATE
20' MINIMUM REAR YARD
50% MAXIMUM LOT COVERAGE 14wwCall bOorew.
Call hefore you dig.