Loading...
HomeMy WebLinkAbout11- Electrical Combined Complete4.3 4.3 1.4 3.2 2.2 1.3 1.3 1.4 4.3 3.3 2.1 1.4 1.3 1.3 1.7 2.1 4.1 3.6 2.6 1.8 1.3 1.2 1.5 2.0 2.6 2.5 3.1 2.7 2.0 1.4 1.2 1.2 1.7 2.5 3.7 2.2 2.2 1.9 1.5 1.2 1.2 1.8 2.9 4.1 1.4 1.8 1.7 1.5 1.2 1.3 1.8 2.9 4.1 0.9 1.4 1.5 1.4 1.3 1.1 1.0 1.1 1.3 1.8 2.6 3.5 0.9 1.3 1.4 1.3 1.2 1.1 1.1 1.4 1.7 2.2 2.7 0.6 0.9 1.2 1.2 1.2 1.2 1.2 1.3 1.3 1.4 1.7 2.0 2.2 0.8 0.9 1.0 1.1 1.2 1.4 1.6 1.6 1.6 1.6 1.7 1.7 1.0 1.1 1.0 0.9 1.0 1.1 1.3 1.7 1.8 1.7 1.6 1.4 1.4 1.3 1.2 1.1 0.9 0.9 1.0 1.3 1.8 2.6 3.3 2.4 1.8 1.6 1.4 1.1 2.1 1.6 1.2 1.0 0.8 0.8 1.0 1.3 1.8 2.4 2.7 2.2 1.7 1.4 1.2 0.9 3.2 2.2 1.5 1.1 0.9 0.9 1.1 1.5 1.7 1.8 1.7 1.5 1.3 1.0 0.8 4.3 3.5 2.2 1.4 1.0 0.7 0.7 0.7 0.9 1.0 1.2 1.3 1.4 1.3 1.3 1.2 1.0 0.8 4.2 3.9 3.0 1.9 1.3 0.9 0.7 0.8 0.9 0.9 1.0 1.1 1.1 1.1 1.1 1.2 1.1 0.9 2.3 3.4 3.1 2.3 1.6 1.2 0.9 0.8 0.8 0.8 0.9 0.9 0.9 1.0 1.0 1.0 1.1 1.2 1.3 1.2 2.3 2.4 2.2 1.7 1.4 1.1 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 1.0 1.2 1.4 1.4 1.3 1.8 1.8 1.6 1.4 1.2 1.1 1.1 1.1 1.1 1.1 1.1 1.0 1.0 0.9 0.8 0.8 1.0 1.2 1.5 1.7 1.2 1.4 1.4 1.4 1.3 1.2 1.3 1.3 1.4 1.4 1.4 1.3 1.2 1.1 1.0 0.9 0.8 1.0 1.3 1.8 2.2 0.5 0.8 1.1 1.2 1.2 1.2 1.3 1.5 1.6 1.8 1.8 1.7 1.6 1.4 1.2 1.0 0.9 0.8 1.0 1.4 2.1 2.7 0.6 0.7 0.8 1.0 1.0 1.0 1.4 1.7 2.1 2.3 2.4 2.3 2.0 1.6 1.3 1.1 0.9 0.9 1.1 1.6 2.5 3.8 0.9 0.9 0.8 0.8 0.8 1.0 1.2 1.6 2.0 2.6 3.2 3.4 3.1 2.5 1.9 1.4 1.1 0.9 0.9 1.1 1.7 2.7 4.0 1.3 1.1 1.0 0.8 0.7 1.0 1.3 1.6 2.3 3.3 4.4 5.1 4.2 3.0 2.1 1.5 1.2 0.9 0.9 1.1 1.6 2.6 3.9 2.1 1.7 1.2 1.0 0.8 0.7 0.7 0.8 1.0 1.3 1.7 2.4 3.4 4.9 6.4 4.6 3.1 2.2 1.5 1.2 0.9 0.9 1.1 1.5 2.2 3.1 3.4 2.5 1.8 1.3 0.9 0.7 0.7 0.7 0.8 1.0 1.3 1.7 2.3 3.2 4.1 4.6 3.9 3.0 2.1 1.6 1.2 1.0 0.9 1.0 1.4 1.9 2.3 4.2 4.0 2.7 1.9 1.3 1.0 0.8 0.7 0.8 0.9 1.1 1.4 1.7 2.1 2.6 3.1 3.2 3.0 2.5 2.0 1.6 1.2 1.0 0.9 1.0 1.3 1.6 1.9 4.7 3.7 2.6 1.8 1.4 1.1 0.9 0.9 1.0 1.1 1.2 1.5 1.7 2.0 2.3 2.5 2.6 2.4 2.2 1.9 1.6 1.3 1.0 0.9 1.0 1.2 1.5 1.6 4.0 4.0 3.1 2.4 1.9 1.1 1.1 1.1 1.2 1.4 1.5 1.8 1.9 2.1 2.2 2.3 2.2 2.0 1.8 1.6 1.3 1.0 0.9 1.0 1.2 1.6 1.7 3.2 3.1 2.7 2.3 1.4 1.3 1.3 1.4 1.5 1.6 1.8 1.9 2.0 2.2 2.2 2.1 1.9 1.8 1.5 1.3 1.0 0.9 0.9 1.2 1.5 1.6 1.9 2.6 2.8 2.7 2.5 2.3 2.0 1.9 1.7 1.6 1.5 1.5 1.5 1.7 1.8 1.9 2.1 2.2 2.2 2.2 2.0 1.8 1.5 1.3 1.0 0.8 0.8 1.0 1.3 1.5 1.6 2.2 2.5 2.5 2.4 2.5 2.5 2.6 2.6 2.4 2.1 1.8 1.6 1.5 1.6 1.7 1.8 2.0 2.2 2.4 2.4 2.3 2.1 1.8 1.5 1.2 1.0 0.8 0.8 1.0 1.3 1.7 1.9 2.3 2.4 2.3 2.3 2.6 3.1 3.5 3.6 3.2 2.5 2.0 1.7 1.6 1.6 1.7 1.9 2.2 2.5 2.9 2.9 2.7 2.3 1.9 1.5 1.2 0.9 0.8 0.8 1.0 1.4 2.0 1.8 2.1 2.1 2.2 2.1 2.2 2.7 3.7 4.9 5.2 4.0 2.9 2.1 1.7 1.6 1.5 1.7 1.9 2.4 3.1 3.7 3.9 3.5 2.7 2.0 1.5 1.2 0.9 0.8 0.8 1.0 1.6 2.4 2.4 2.2 2.0 1.8 1.8 2.0 2.6 3.7 5.3 6.0 4.2 2.9 2.1 1.7 1.5 1.5 1.6 1.9 2.5 3.5 4.9 5.7 3.0 2.1 1.5 1.1 0.9 0.7 0.8 1.1 1.7 3.3 2.8 2.2 1.8 1.6 1.6 1.9 2.4 4.2 3.5 2.7 2.0 1.7 1.5 1.5 1.6 1.9 2.5 3.5 4.9 5.8 3.0 2.1 1.5 0.8 1.1 1.7 4.3 3.2 2.2 1.6 1.4 1.4 1.6 2.0 2.5 2.2 1.8 1.8 2.3 3.0 2.6 1.9 1.4 1.1 0.8 0.7 0.7 1.0 1.6 2.5 3.6 2.5 4.1 2.9 1.9 1.4 1.2 1.3 1.4 1.6 1.9 2.0 2.1 1.9 1.8 1.6 1.4 1.4 1.3 1.5 1.6 1.9 2.3 2.6 2.7 2.5 2.1 1.6 1.3 1.0 0.8 0.6 0.7 0.9 1.4 2.0 2.6 1.8 3.4 2.4 1.6 1.2 1.0 1.1 1.2 1.3 1.4 1.5 1.6 1.5 1.4 1.3 1.3 1.2 1.2 1.3 1.4 1.6 1.8 1.9 1.9 1.8 1.6 1.4 1.2 0.9 0.7 0.6 0.6 0.8 1.2 1.6 2.0 1.8 1.2 0.9 0.8 1.1 1.1 1.2 1.2 1.4 1.3 1.2 1.1 1.1 1.1 1.2 1.3 1.4 1.5 1.5 1.4 1.4 0.8 0.6 0.6 1.1 1.4 1.5 1.0 0.7 0.6 0.8 0.8 0.9 0.9 0.9 1.0 1.0 1.1 1.1 1.2 0.7 0.6 0.9 1.4 1.5 1.4 1.2 1.5 1.4 1.9 0.6 0.5 0.7 0.7 0.7 0.8 2.4 1.9 1.9 1.8 1.5 2.4 2.4 2.3 2.0 1.6 3.0 2.8 2.7 2.0 1.4 3.0 2.5 2.7 1.9 1.3 2.9 2.6 2.5 1.9 1.3 3.1 2.6 2.6 1.9 1.3 2.8 2.9 2.6 2.1 1.5 2.9 3.1 2.6 2.2 1.8 2.9 3.0 2.6 2.2 1.8 2.8 2.8 2.6 2.0 1.5 3.1 2.5 2.6 1.8 1.3 2.9 2.6 2.4 1.8 1.2 3.0 2.4 2.5 1.8 1.2 2.8 2.6 2.4 1.8 1.2 0.8 1.8 1.5 1.1 0.8 1.2 1.0 0.8 0.6 FDCFHP3S P3S P3S P3S P5D P5D P5 P3S B3B3 B3 B3 B3 B3 B3 B3 B3 B3 B3 P3S P3S 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.3 0.3 0.3 0.2 0.2 0.2 0.2 0.3 0.5 0.5 0.6 0.6 0.6 0.6 0.8 0.9 0.8 0.7 0.6 0.6 0.6 0.6 0.6 0.4 0.2 0.2 0.2 0.2 0.4 0.4 0.3 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.3 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.00.00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 P4S P4S P5D Luminaire Schedule Symbol Qty Label Arrangement LLF Description Arr. Lumens Arr. Watts Total Watts 11 B3 SINGLE 0.920 LUMCA LUBA40-18LED-30W-L3-VOLT-COLOR-PANELS-AB 2993 31.09 341.99 7 P3S SINGLE 0.920 USA RZR-PLED-III-W-80LED-525mA-NW-VOLT-FINISH-HS-PLED & DS330-400Q200-D1-FINISH- 12271 129.4 905.7999 3 P5D 2 @ 180 DEGREES 0.920 USA RZR-PLED-VSQ-W-80LED-525mA-NW-VOLT-FINISH & DS330-400Q200-D2-FINISH-COLOR-FB 34236 258.8 776.4 1 P5 SINGLE 0.920 USA RZR-PLED-VSQ-W-80LED-525mA-NW-VOLT-FINISH & DS330-400Q200-D1-FINISH-COLOR-FB 17118 129.4 129.4 2 P4S SINGLE 0.920 USA RZR-PLED-IV-FT-80LED-525mA-NW-VOLT-FINISH-HS-PLED & DS330-400Q200-D1-FINISH- 12238 129.4 258.8 Calculation Summary Label CalcType Units Avg Max Min Avg/Min Max/Min PARKING AND DRIVE Illuminance Fc 1.77 6.4 0.5 3.54 12.80 PROPERTY LINE Illuminance Fc 0.12 0.9 0.0 N.A. N.A. SCALE: 1"=40'-0" ELECTRICAL PHOTOMETRIC PLAN Engin ngir LLC8200 PEACHTREE AVE. ROCKFORD, MI 49341 P. 616-340-9627 ELECTRICAL PHOTOMETRIC PLAN ES1 P:\2018\2018388 Aloft-Element Carmel\Working Drawings\ES1-CDB.dwg, 5/27/2020 7:34:36 AM, cll09/28/20 CWOCWOCWOCWO P5D B3 B3 B3 B3 P3S 0,0,0 P3S P3S P3S FUTURE VEHICLE CHARGING STATION PROVIDE (2) 4" CONDUIT TO BUILDING FOR COMMUNICATIONS AND 1" CONDUIT FOR POWER FUTURE STATION. P5D P5D P5D P5 P3S P3S P3S P4S P4S B3B3 B3 B3 B3 B3 B3B3 B3 B3 B3 X106 X102 X103 CAR CHARGER VEHICLE (1) CHARGING STATION SIMILAR TO A TESLA SUPERCHARGING STATIONS. RATED FOR 150w PROVIDE 1" CONDUIT TO BUILDING FOR COMMUNICATIONS AND 1" CONDUIT FOR POWER 2P40A 2#8+G 1C-4/6, VERIFY FEED WITH FINAL SELECTION. ALSO PROVIDE (1) CHARGING STATION SIMILAR TO A LEVITON BOLLARD STYLE CAR CHARGING STATION. RATED FOR UP TO 145W. PROVIDE 1" CONDUIT TO BUILDING FOR COMMUNICATIONS AND 1" CONDUIT FOR POWER 2P40A 2#8+G-4/6, VERIFY FEED WITH FINAL SELECTION GENERATOR - REFER TO E6.00 BATTERY CHARGING 1C-1 UTILITY TRANSFORMER REFER TO E6.00 UG1 FOR IN GROUND LIGHTING ON FLAG POLE. TWO SIDES MOUNTED 6' FROM POLE BASE. COORDINATE W/ARCH PLANS FOR EXACT LOCATION. UG1UG1X107 X108 P MONUMENT SIGN VERIFY WITH SIGNAGE CONTRACTOR TESLA CHARGER SCALE: 1"=40'-0" ELECTRICAL SITE PLAN ELECTRICL SITE PLAN AND DETAILS ES2 Engin ngir LLC8200 PEACHTREE AVE. ROCKFORD, MI 49341 P. 616-340-9627 8"2'-0"4,000 PSI CONC. FINISHED GRADE (4) 1/2" x 11" ANCHOR BOLTS ON 4-1/2" BOLT CIRCLE. BOLTS AND TEMPLATES FURNISHED BY OWNER. TOP OF FOOTING PVC CONDUIT PER LOCAL 1" ABOVE GRADE. CODES 1"R N.T.S. 21'-40'30"6'0"30" IN PARKING LOT DCBA LOCATION POLE AND BASE DIMENSIONS PROVIDE FUSE(S) IN CKT. TO BALLAST. FUSE(S) SHALL BE BUSS TYPE BBS. FUSE HOLDERS SHALL BE BUSS 'TRON' HEH WATER PROOF. SIZE OF FUSE SHALL BE AS REQUIRED BY LUMINAIRE MANUFACTURER. CONNECT GROUND TO POLE BASE W/BURNDY NO. GB4C BASE COVER BUSH CONDUITS CONDUIT FOR GROUND WIRE GROUND WIRE D C B POLE - REFER TO SITE FIXTURE SCHEDULE FOR ACTUAL HEIGHT FLUSH HANDHOLE AND COVER PROJECT ANCHOR BOLTS 3" ABV. TOP OF BASE. PROVIDE DOUBLE NUTS FOR LEVELING UNIT(ONE ABOVE AND ONE BELOW BASE FLANGE) GROUT VOID BETWEEN BASE FLANGE AND TOP OF CONCRETE AND HAND FINISH 1" CHAMFER ANCHOR BOLTS TO BE FURNISHED BY E.C. EXPOSED CONCRETE TO HAVE RUBBED FINISH FINISHED GRADE UNDISTURBED EARTH CONDUIT IN CONCRETE CONDUIT AS REQUIRED BURY 18" 5/8" x 8' COPPER WELD GROUND ROD A 3"3" SEE PLANS FOR TYPE OF WIRING 4#5 REBAR #3 TIES AT 12" O.C. REINFORCED CONCRETE BASE BY CONCRETE CONTRACTOR. E.C. TO COORDINATE. N.T.S. 0-20'30"6'0"24" IN PARKING LOT 21'-40'6"6'0"30" IN GREEN SPACE 0-20' 6"6'0"24" IN GREEN SPACE P:\2018\2018388 Aloft-Element Carmel\Working Drawings\ES2-CDB.dwg, 5/27/2020 7:35:52 AM, cll09/28/20 UP UP 22 X 3924 X 48 24 X 42 24 X 36 24 X 36 24 X 36 24 X 3624 X 4824 X 4224 X 54 24 X 48 14 X 4214 X 42 24 X 24 24 X 4218 X 4218 X 4218 X 4218 X 4218 X 4224 X 5424 X 2421 X 48 21 X 3621 X 42 21 X 42 21 X 42 21 X 42 21 X 6021 X 60 21 X 60 21 X 60 21 X 4221 X 4221 X 42 21 X 4221 X 42 21 X 4224 X 54 24 X 36ELEMENTALOFT S 2 E301 1 E301 3 E300 4 E300 1 EP224 1 EP222 1 EP227 1 EP226 2 EP228 1 EP228 1 EP221 1 EP223 2 EP226 1 EP225 3 EP228 1 EL224 1 EL222 1 EL227 1 EL226 2 EL228 1 EL228 1 EL221 1 EL223 2 EL226 1 EL225 3 EL228 Engin ngir LLC8200 PEACHTREE AVE. ROCKFORD, MI 49341 P. 616-340-9627 SCALE: 1/16" = 1'-0" POWER & LIGHTING1 E101 OVERALL FIRST FLOOR P:\2018\2018388 Aloft-Element Carmel\Working Drawings\E101 -Carmel DB.dwg, 5/26/2020 1:54:41 PM, cll09/28/20 DN UP UP DN ELEMENTALOFT DS-1 2A-63RE:C2/E5.0EF-4 T 2B-51RE:B1/E501EF-4 2B-53,55 DS-1 T 1 E203a 1 E204a 1 E205a 1 E206a 1 E203b 1 E204b 1 E205b 1 E206b A E203a A E204a A E205a A E206a A E203b A E204b A E205b A E206b A E202a A E202b1 E202b 1 E202a Engi n ngir LLC8200 PEACHTREE AVE. ROCKFORD, MI 49341 P. 616-340-9627 SCALE: 1/16" = 1'-0" POWER, TECHNOLOGY, & LIGHTING1 E102 OVERALL SECOND-SIXTH FLOORS P:\2018\2018388 Aloft-Element Carmel\Working Drawings\E102 -Carmel DB.dwg, 5/26/2020 1:56:24 PM, cll09/28/20 F RE:ONELINE/E6.0 3P20 RTU-3 D D F RE:ONELINE/E6.0 3P50 RTU-4 D F RE:ONELINE/E6.0 3P50 RTU-5 DWR 2D-33 WR 2D-33 WR 2D-33 WR 2D-33 X607 P ELEMENT SIGNAGE P 2P20 2D-25/29AC-13 12.8 RLA F RE:ONELINE/E6.0 3P20 RTU-2 D F RE:ONELINE/E6.0 3P20 RTU-1 P 2P20 2D-26/28AC-14 12.8 RLA P 2P20 2D-29/31AC-15 4.9 RLA P 2P70 2D-30/32AC-16 58.3 RLA P 2P20 2D-1/3AC-1 12.8 RLA F 2P40 2D-5/7 AC-2 27.6 RLA P 2P20 2D-9/11AC-3 15.4 RLA F 2P30 2D-13/15AC-4 21.8 RLA P 2P40 2D-10/12AC-5 27.6 RLA F 2P40 2D-14/16AC-6 27.6 RLA P 2P20 2D-18/20AC-7 15.4 RLA F 2P30 2D-17/19AC-8 12.8 RLA P 2P20 2D-6/8AC-9 12.8 RLA P 2P20 2D-2/4AC-10 18.2 RLA P 2P20 2D-22/24AC-11 12.8 RLA P 2P20 2D-21/23AC-12 12.8 RLA WR 2D-33 NOTE: RTU'S ARE PROVIDED WITH RECEPTACLES AND DISCONNECTS. THE E.C. TO MAKE CONNECTION TO DISCONNECT AND CIRCUIT RECEPTACLES AS SHOWN. P 2P20 2D-29/31AC-15 4.9 RLA P 2P20 2D-30/32AC-16 4.9 RLA P 2P20 2D-37/39AC-17 4.9 RLA P 2P20 2D-38/40AC-18 4.9 RLA P 2P20 2D-43/45AC-19 4.9 RLA P 2P20 2D-47/49AC-20 4.9 RLA P 2P20 2D-44/46AC-22 4.9 RLA P 2P20 2D-30/32 AC-23 4.9 RLA P 2P20 2D-52/54 AC-24 4.9 RLA P 2P20 2D-51/53AC-21 4.9 RLA Engi n ngir LLC8200 PEACHTREE AVE. ROCKFORD, MI 49341 P. 616-340-9627 SCALE: 1/16" = 1'-0" LOWER ROOF PLAN - LIGHTING/POWER1 E106 P:\2018\2018388 Aloft-Element Carmel\Working Drawings\E106 -Carmel DB.dwg, 5/26/2020 1:57:16 PM, cll09/28/20 WR 6A-71 F RE:ONELINE/E6.0 3P70 MAU-2 D AL1-X AL1-X AL1-X AL1-X AL1-X AL1-X AL1-X EXTERIOR LIGHTING. REFER TO ARCH ELEVATIONS FOR EXACT LOCATION X601 AL1-X AL1-X AL1-X AL1-X AL1-X AL1-X AL1-X AL1-X F RE:ONELINE/E6.0 3P70 MAU-1 52 MCA DWR 6B-56 Engi n ngir LLC8200 PEACHTREE AVE. ROCKFORD, MI 49341 P. 616-340-9627 SCALE: 1/16" = 1'-0" ROOF PLAN - LIGHTING/POWER1 E107 P:\2018\2018388 Aloft-Element Carmel\Working Drawings\E107 -Carmel DB.dwg, 5/26/2020 1:58:11 PM, cll09/28/20 GENERAL POWER NOTES: 1. 2. 3. 4. 5. 6. 7. POWER KEY NOTES: 1 2 3 4 5 6 7 ALL 15A & 20A 120V NON-LOCKING RECEPTACLES WITHIN CHILDCARE AREAS (AGES 7 & UNDER) SHALL BE LISTED TAMPER RESISTANT PER NEC 406.12. THIS INCLUDES GUEST ROOMS. MOUNT PANELS, TRANSFORMERS, DISCONNECT SWITCHES, AND COMBINATION MOTOR STARTERS WITH ADEQUATE CLEARANCES IN ACCORDANCE WITH NEC 110. VOLTAGE DROP TO MEET ASHRAE 90.1 (2007) ELEMENT ROOMS WHERE PANEL IS INDICATED - LABEL PANELS IN EACH ROOM WITH FINAL ROOM NUMBERS, COORDINATE WITH ARCHITECT FOR FINAL ROOM NUMBERING. DENOTED ON PLAN AS BPG (FLOOR #)-XX. "XX" DENOTE ROOM NUMBER INSTALL FIRE ALARM PER MARRIOTT'S MODULE 14 STANDARDS INSTALL PER LATEST NEC CODE: 2008 NEC NOT ALL POWER KEY NOTES ARE USED ON EACH FLOOR E.C. SHALL WIRE INTAKE DOORS FOR LAUNDRY CHUTE PER CHUTE MANUFACTURER'S ELECTRICAL INTERLOCK WIRING DIAGRAM. INSTALL AND WIRE MANUAL ON/OFF SWITCH, PROVIDED WITH UNIT IN LAUNDRY ROOM . SMOKE DETECTOR TO BE WIRED TO DOOR INTERLOCK SO THAT INTERLOCKS WILL NOT OPERATE UPON ACTIVATION OF SMOKE DETECTOR, TYPICAL EACH FLOOR. PROVIDE 120V POWER TO INTAKE DOOR AND RUN 4 WIRES BETWEEN FLOORS TO EACH INTAKE DOOR. CONNECT ALL SMOKE DAMPERS TO 120V CIRCUIT AS SHOWN, COORDINATE VOLTAGE WITH SUPPLIER. CONNECT TO FIRE ALARM SYSTEM. VERIFY QUANTITY AND LOCATIONS WITH MECHANICAL PLANS. PROVIDE TWO-WAY COMMUNICATION SYSTEMS. REFER TO SPEC SECTION 283100 AT RECEPTION DESK AND CENTRAL CONTROL UNIT IN MPF ROOM. CONTROL EF WITH LIGHT SWITCH REFER TO FOOD SERVICE ELECTRICAL PLANS FOR EQUIPMENT REQUIREMENTS AND MOUNTING HEIGHTS. EC TO PROVIDE AND INSTALL CORD AND PLUG, NEMA 5-20R ELEV. CAB LIGHT DISC. (1) 1P20A CKT BREAKER MTD IN NEMA-1 ENCLOSURE W/HANDLE PADLOCK ATTACHMENT CAPABLE OF LOCKING BREAKER IN OPEN POSITION. PROVIDE NAMEPLATE ON DISC. INDICATING PANEL NAME. COORDINATE LOCATIONS OF ALL EQUIPMENT IN ELEVATOR EQUIPMENT ROOM/HOIST ROOM AND PIT WITH ELEVATOR SHOP DRAWINGS PRIOR TO ROUGH-IN. CONNECT EMERGENCY SHUT-DOWN OF ELEVATOR AS REQUIRED. SEQUENCE EQUIPMENT TO SHUT-DOWN THE ELEVATOR BY SMOKE DETECTORS WHEN REQUIRED. ELECTRICAL CONTRACTOR SHALL REFERENCE ELEVATOR SPECIFICATIONS AND COORDINATE ALL REQUIREMENTS WITH ELEVATOR MANUFACTURER FOR ALL ELECTRICAL REQUIREMENTS PRIOR TO ROUGH-IN. COORDINATE QUANTITY & LOCATION OF FIRE SUPPRESSION RISERS AND TAMPER SWITCHES WITH FIRE SUPPRESSION PLANS. VERIFY WITH STATE CODE TO PROVIDE SMOKE DETECTION FOR ELEVATOR, PROVIDE AND INSTALLED BY E.C. CONNECT TO FIRE ALARM SYSTEM UNLESS NOT ALLOWED BY STATE CODE. PROVIDE POWER AND CONTROL TO SIGNAGE, VERIFY EXACT LOCATION WITH ARCHITECTURAL ELEVATIONS AND FINAL CONNECTIONS WITH SIGNAGE SHOP DRAWINGS 8 9 GENERAL LIGHTING NOTES: 1. 2. 3. 4. 5. 6. EGRESS ILLUMINATION LEVELS MEET NFPA 101 OR LOCAL CODE LIGHTING DESIGN COMPLIES WITH 2010 INDIANA ENERGY CODE/ASHRAE 90.1 2007 VOLTAGE DROP TO MEET ASHRAE 90.1 (2007) CONNECT CORRIDOR, ELEVATOR LOBBY AND CORRIDOR FIXTURES TO EMERGENCY CIRCUIT AND NORMAL CIRCUIT, RUN 24/7, REFER TO LIGHTING CONTROL SCHEDULE OR PLANS FOR CIRCUITING CONNECT EMERGENCY LIGHTING TO UL LISTED 924 EMERGENCY TRANSFER DEVICE FOR ALL EMERGENCY LOADS. EMERGENCY LIGHTING MAY BE GROUPED TOGETHER ON ONE TRANSFER DEVICE SIZED FOR LOAD PER LIGHTING ZONES. CONNECT EXIT SIGNS TO EMERGENCY LIGHTING CIRCUIT FEEDING LIGHTING IN AREA AHEAD OF SWITCHING. LIGHTING KEYNOTES: PROVIDE POWER TO SIGNAGE REFER TO ARCH ELEVATIONS. COORDINATE WITH FINAL SIGNAGE PLANS. LOCAL SWITCHES TO OVERRIDE OCCUPANCY SENSOR OFF FOR AV USAGE. PROVIDE LOCAL DIMMER SWITCH AT PANEL TO SET LIGHTING LEVEL AT ONSET OF JOB. PROVIDE DIMMING EMERGENCY TRANSFER DEVICE FOR DIMMED CORRIDOR LOADS TO BRING EMERGENCY CORRIDOR LIGHTING TO 100% IN GENERATOR MODE. LIGHTS RUN 24/7. L2 L1 L3 10 UP DN UP DN 2C-1 - GENERAL CIRCUIT 2C-3 - BATHROOM CIRCUIT 2C-5 - MICROWAVE 2C-7/9 2P20A - VTAC CIRCUIT PG-401-1 PG-401-1 E E E E E E E E E E PG-401 PG-401 PG-401PG-401 PG-401PG-401 PG-401 PG-401 PG-401 ALR-09 ALR-09 ALR-09 ALR-09ALR-09ALR-09 ALR-09ALR-09 ALR-09 ALR-09 ALR-09 ALR-09 ALR-09 ALR-09 ALR-09 ALR-09 ALR-09 ALR-09 ALR-09 2A-59 2A-9- GENERAL CIRCUIT 2A-11 BATHROOM CIRCUIT 2A-13/15 2P20A - VTAC CKT 2A-1 - GENERAL CIRCUIT 2A-3 - BATHROOM CIRCUIT 2A-5/7 2P20A - VTAC CKT 2A-25- GENERAL CIRCUIT 2A-27 BATHROOM CIRCUIT 2A-29/31 2P20A - VTAC CKT 2A-17 - GENERAL CIRCUIT 2A-19 - BATHROOM CIRCUIT 2A-21/23 2P20A - VTAC CKT 2A-33 - GENERAL CIRCUIT 2A-35 - BATHROOM CIRCUIT 2A-37/39 2P20A - VTAC CKT IR A2 2A-55 2A-59 2A-592A-59 2A-57 2A-57 2A-57 2A-57 TO LIGHTS ABOVE FS TS FW1 FW1 8 2A-2 - GENERAL CIRCUIT 2A-4 - BATHROOM CIRCUIT 2A-6/8 2P20A - VTAC CKT 2A-10 - GENERAL CIRCUIT 2A-12 - BATHROOM CIRCUIT 2A-14/16 2P20A - VTAC CKT 2A-18 - GENERAL CIRCUIT 2A-20 - BATHROOM CIRCUIT 2A-22/24 2P20A - VTAC CKT 2A-26 - GENERAL CIRCUIT 2A-28 - BATHROOM CIRCUIT 2A-30/32 2P20A - VTAC CKT 2A-34 - GENERAL CIRCUIT 2A-36 - BATHROOM CIRCUIT 2A-38/40 2P20A - VTAC CKT 2A-44- GENERAL CIRCUIT 2A-46 - BATHROOM CIRCUIT 2A-48/50 2P20A - VTAC CKT 2A-43- GENERAL CIRCUIT 2A-45 - BATHROOM CIRCUIT 2A-47/49 2P20A - VTAC CKT 2A-69 GFI BRKR W A2 A2 A2 A2 A2 OS 2C-38 2C-38 2C-38 1 2C-38 J 3 F/SD 2 EM3-1 R-02R-02 W 2C-41 ALR-09 ALR-09 ALR-09 R-02 J4'EJ4J4'E 2B-1 - GENERAL CIRCUIT 2B-3 - BATHROOM CIRCUIT 2B-5/7 2P20A - VTAC CKT 2B-2 - GENERAL CIRCUIT 2B-4 - BATHROOM CIRCUIT 2B-6/8 2P20A - VTAC CKT 2B-9- GENERAL CIRCUIT 2B-11 BATHROOM CIRCUIT 2B-13/15 2P20A - VTAC CKT 2B-17 - GENERAL CIRCUIT 2B-19 - BATHROOM CIRCUIT 2B-21/23 2P20A - VTAC CKT 2B-25- GENERAL CIRCUIT 2B-27 BATHROOM CIRCUIT 2B-29/31 2P20A - VTAC CKT 2B-10 - GENERAL CIRCUIT 2B-12 - BATHROOM CIRCUIT 2B-14/16 2P20A - VTAC CKT 2B-18 - GENERAL CIRCUIT 2B-20 - BATHROOM CIRCUIT 2B-22/24 2P20A - VTAC CKT 2B-26 - GENERAL CIRCUIT 2B-28 - BATHROOM CIRCUIT 2B-30/32 2P20A - VTAC CKT 2B-34 - GENERAL CIRCUIT 2B-36 - BATHROOM CIRCUIT 2B-38/40 2P20A - VTAC CKT 2B-33 - GENERAL CIRCUIT 2B-35 - BATHROOM CIRCUIT 2B-37/39 2P20A - VTAC CKT 2B-44- GENERAL CIRCUIT 2B-46 - BATHROOM CIRCUIT 2B-48/50 2P20A - VTAC CKT 2B-43- GENERAL CIRCUIT 2B-45 - BATHROOM CIRCUIT 2B-47/49 2P20A - VTAC CKT W 2A-57 P 2A-63 P RE:?/E5.0 EF- ALR-09 2A-61 GFI BRKR IR5 5 EXTERIOR LED STRIP LIGHTING. REFER TO ARCH ELEVATIONS FOR EXACT LOCATION. EXTERIOR LED STRIP LIGHTING. REFER TO ARCH ELEVATIONS FOR EXACT LOCATION. XLR-52' XLR-24' A E202a F 2D-34/36 FC-10 DH DH R-02 EF-9 T T T T T T T T TT T T T T T T T TT T T T T T T T X117 X117 ALR-09 ALR-09 A2 STUB (4) 4" C BETWEEN ALL FLOORS RE: 1/ET2.0 PROVIDE 4"X6" GROUND BAR, #8 AWG WIRE 2A-51 EM3-1 2A-51 BP2A 112.5 KVAT-2A DP2A 2A-55 BP2B 3/4" FIRE RATED PLY WOOD. HORIZONTAL MOUNTED CENTER ON WALL. PAINT TO MATCH COLOR OF ROOM. LEAVE FIRE SYMBOL SHOWING.P RE:B2/E5.0DS-1 P 2A-63 RE:C2/E5.0 EF-4 T REFER TO THIS SHEET FOR GUEST SUITE POWER AND LIGHTING CIRCUITS. ALOFT: CORRIDOR LOW LEVEL WALL LIGHTS ALR09 TO BE CONNECTED TO CIRCUIT 2A-58/EM3-2. LIGHTING TO RUN 24/7. DECORATIVE PENDANT LIGHTING PG-401 TO BE CONNECTED TO 2A-58. GENERAL BACK OF HOUSE LIGHTING TO BE CONNECTED TO 2A-60, EMERGENCY LIGHTING DENOTED WITH "E" SUFFIX OR SHOWN HALF SHADED TO BE CONNECTED TO EM3-2 VIA EMERGENCY TRANSFER DEVICE. STAIRWAY LIGHTING TO RUN 24/7 WITH INTEGRAL SENSOR TO REDUCE TO 50% WHEN UNOCCUPIED. LIGHTING TO BE CONNECTED AS FOLLOWS: STAIR 2: 2A-62/EM3-8 ALL EXIT LIGHTS ON GUEST SUITE FLOORS SHALL BE TYPE E3. Engi n ngir LLC8200 PEACHTREE AVE. ROCKFORD, MI 49341 P. 616-340-9627 SCALE: 1/8" = 1'-0" POWER & LIGHTING1 E202a ALOFT SECOND FLOOR SCALE: 1/4" = 1'-0" ENLARGED POWER PLANA E202a ALOFT SECOND FLOOR P:\2018\2018388 Aloft-Element Carmel\Working Drawings\E202a -Carmel DB.dwg, 5/26/2020 1:59:46 PM, cll09/28/20 GENERAL POWER NOTES: 1. 2. 3. 4. 5. 6. 7. POWER KEY NOTES: 1 2 3 4 5 6 7 ALL 15A & 20A 120V NON-LOCKING RECEPTACLES WITHIN CHILDCARE AREAS (AGES 7 & UNDER) SHALL BE LISTED TAMPER RESISTANT PER NEC 406.12. THIS INCLUDES GUEST ROOMS. MOUNT PANELS, TRANSFORMERS, DISCONNECT SWITCHES, AND COMBINATION MOTOR STARTERS WITH ADEQUATE CLEARANCES IN ACCORDANCE WITH NEC 110. VOLTAGE DROP TO MEET ASHRAE 90.1 (2007) ELEMENT ROOMS WHERE PANEL IS INDICATED - LABEL PANELS IN EACH ROOM WITH FINAL ROOM NUMBERS, COORDINATE WITH ARCHITECT FOR FINAL ROOM NUMBERING. DENOTED ON PLAN AS BPG (FLOOR #)-XX. "XX" DENOTE ROOM NUMBER INSTALL FIRE ALARM PER MARRIOTT'S MODULE 14 STANDARDS INSTALL PER LATEST NEC CODE: 2008 NEC NOT ALL POWER KEY NOTES ARE USED ON EACH FLOOR E.C. SHALL WIRE INTAKE DOORS FOR LAUNDRY CHUTE PER CHUTE MANUFACTURER'S ELECTRICAL INTERLOCK WIRING DIAGRAM. INSTALL AND WIRE MANUAL ON/OFF SWITCH, PROVIDED WITH UNIT IN LAUNDRY ROOM . SMOKE DETECTOR TO BE WIRED TO DOOR INTERLOCK SO THAT INTERLOCKS WILL NOT OPERATE UPON ACTIVATION OF SMOKE DETECTOR, TYPICAL EACH FLOOR. PROVIDE 120V POWER TO INTAKE DOOR AND RUN 4 WIRES BETWEEN FLOORS TO EACH INTAKE DOOR. CONNECT ALL SMOKE DAMPERS TO 120V CIRCUIT AS SHOWN, COORDINATE VOLTAGE WITH SUPPLIER. CONNECT TO FIRE ALARM SYSTEM. VERIFY QUANTITY AND LOCATIONS WITH MECHANICAL PLANS. PROVIDE TWO-WAY COMMUNICATION SYSTEMS. REFER TO SPEC SECTION 283100 AT RECEPTION DESK AND CENTRAL CONTROL UNIT IN MPF ROOM. CONTROL EF WITH LIGHT SWITCH REFER TO FOOD SERVICE ELECTRICAL PLANS FOR EQUIPMENT REQUIREMENTS AND MOUNTING HEIGHTS. EC TO PROVIDE AND INSTALL CORD AND PLUG, NEMA 5-20R ELEV. CAB LIGHT DISC. (1) 1P20A CKT BREAKER MTD IN NEMA-1 ENCLOSURE W/HANDLE PADLOCK ATTACHMENT CAPABLE OF LOCKING BREAKER IN OPEN POSITION. PROVIDE NAMEPLATE ON DISC. INDICATING PANEL NAME. COORDINATE LOCATIONS OF ALL EQUIPMENT IN ELEVATOR EQUIPMENT ROOM/HOIST ROOM AND PIT WITH ELEVATOR SHOP DRAWINGS PRIOR TO ROUGH-IN. CONNECT EMERGENCY SHUT-DOWN OF ELEVATOR AS REQUIRED. SEQUENCE EQUIPMENT TO SHUT-DOWN THE ELEVATOR BY SMOKE DETECTORS WHEN REQUIRED. ELECTRICAL CONTRACTOR SHALL REFERENCE ELEVATOR SPECIFICATIONS AND COORDINATE ALL REQUIREMENTS WITH ELEVATOR MANUFACTURER FOR ALL ELECTRICAL REQUIREMENTS PRIOR TO ROUGH-IN. COORDINATE QUANTITY & LOCATION OF FIRE SUPPRESSION RISERS AND TAMPER SWITCHES WITH FIRE SUPPRESSION PLANS. VERIFY WITH STATE CODE TO PROVIDE SMOKE DETECTION FOR ELEVATOR, PROVIDE AND INSTALLED BY E.C. CONNECT TO FIRE ALARM SYSTEM UNLESS NOT ALLOWED BY STATE CODE. PROVIDE POWER AND CONTROL TO SIGNAGE, VERIFY EXACT LOCATION WITH ARCHITECTURAL ELEVATIONS AND FINAL CONNECTIONS WITH SIGNAGE SHOP DRAWINGS 8 9 GENERAL LIGHTING NOTES: 1. 2. 3. 4. 5. 6. EGRESS ILLUMINATION LEVELS MEET NFPA 101 OR LOCAL CODE LIGHTING DESIGN COMPLIES WITH 2010 INDIANA ENERGY CODE/ASHRAE 90.1 2007 VOLTAGE DROP TO MEET ASHRAE 90.1 (2007) CONNECT CORRIDOR, ELEVATOR LOBBY AND CORRIDOR FIXTURES TO EMERGENCY CIRCUIT AND NORMAL CIRCUIT, RUN 24/7, REFER TO LIGHTING CONTROL SCHEDULE OR PLANS FOR CIRCUITING CONNECT EMERGENCY LIGHTING TO UL LISTED 924 EMERGENCY TRANSFER DEVICE FOR ALL EMERGENCY LOADS. EMERGENCY LIGHTING MAY BE GROUPED TOGETHER ON ONE TRANSFER DEVICE SIZED FOR LOAD PER LIGHTING ZONES. CONNECT EXIT SIGNS TO EMERGENCY LIGHTING CIRCUIT FEEDING LIGHTING IN AREA AHEAD OF SWITCHING. LIGHTING KEYNOTES: PROVIDE POWER TO SIGNAGE REFER TO ARCH ELEVATIONS. COORDINATE WITH FINAL SIGNAGE PLANS. LOCAL SWITCHES TO OVERRIDE OCCUPANCY SENSOR OFF FOR AV USAGE. PROVIDE LOCAL DIMMER SWITCH AT PANEL TO SET LIGHTING LEVEL AT ONSET OF JOB. PROVIDE DIMMING EMERGENCY TRANSFER DEVICE FOR DIMMED CORRIDOR LOADS TO BRING EMERGENCY CORRIDOR LIGHTING TO 100% IN GENERATOR MODE. LIGHTS RUN 24/7. L2 L1 L3 10 DN UP DN UP 2C-1 - GENERAL CIRCUIT 2C-3 - BATHROOM CIRCUIT 2C-5 - MICROWAVE 2C-7/9 2P20A - VTAC CIRCUIT 2C-11 - GENERAL CIRCUIT 2C-13 - BATHROOM CIRCUIT 2C-15 - MICROWAVE 2C-17/19 2P20A - VTAC CIRCUIT 2C-21 - GENERAL CIRCUIT 2C-23 - BATHROOM CIRCUIT 2C-25 - MICROWAVE 2C-27/29 2P20A - VTAC CIRCUIT BPG2 BPG2 BPG2 2C-2- GENERAL CIRCUIT 2C-4- BATHROOM CIRCUIT 2C-6 - MICROWAVE 2C-8/10 2P20A - VTAC CIRCUIT 2C-12 - GENERAL CIRCUIT 2C-14 - BATHROOM CIRCUIT 2C-16 - MICROWAVE 2C-18/20 2P20A - VTAC CIRCUIT BPG2 BPG2 2C-22 - GENERAL CIRCUIT 2C-24 - BATHROOM CIRCUIT 2C-26 - MICROWAVE 2C-28/30 2P20A - VTAC CIRCUIT BPG2 BPG2 BPG2 BPG2 BPG2 BPG2 BPG2 BPG2 BPG2 PG-401-1 R-02 PG-402 PG-401-1 PG-401-1 R-02 R-02 R-02 R-02 R-02 R-02 R-02 R-02 R-02R-02 PG-402 PG-402 PG-402 PG-402 PG-402 PG-402 PG-402 PG-401-1 PG-401-1 PG-401-1 PG-401-1PG-401-1 PG-401-1 PG-401-1 PG-401-1 PG-401-1 PG-402 PG-402 PG-402 PG-402 2C-41 2C-41 E E E E E E E 2C-41 2C-41 2C-32 2C-32 2C-32 2C-32 2C-32 IR A2 A2 2C-40 2C-40 TO LIGHTS ABOVE FS TS FW1 FW1 8 2C-32 W A2 A2 A2 OS 2C-38 W R-02R-02 PG-402 PG-402 PG-402 PG-402PG-402 PG-402 PG-402 PG-402 PG-402 PG-402 PG-402 F/SD 2 EM3-3 2C-32 PG-402 PG-402 PG-401-1 PG-402 BPG2 R-02 A E202b J4'E J4J4'E F 2D-34/36 FC-10 DH T T T T T T T TT T T T T T T T T T TT T 3/4" FIRE RATED PLY WOOD. HORIZONTAL MOUNTED CENTER ON WALL. PAINT TO MATCH COLOR OF ROOM. LEAVE FIRE SYMBOL SHOWING. STUB (4) 4" C BETWEEN ALL FLOORS RE: 1/ET2.0 PROVIDE 4"X6" GROUND BAR, #8 AWG WIRE 2C-31EM1- 2C-32 BP2C 150 KVA T-2B BP2D SDP2B 2C-40 P 2B-51 RE:B1/E501 EF-4 P 2B-53,55 RE:B4/E501 DS-1 T REFER TO SHEETE E612 FOR POWER AND LIGHTING CIRCUITS IN PANELS BP-G2 AND BP-G3. ALL OTHER GUEST SUITES WITHOUT A ROOM ELECTRICAL PANEL, CIRCUITS FOR POWER AND LIGHTING NOTED ON THIS PLAN. ELEMENT: CORRIDOR DOWNLIGHTS R-02 TO BE CONNECTED TO CIRCUIT 2C-34/EM3-4. LIGHTING TO RUN 24/7. REFER TO KEY NOTE L3 DECORATIVE PENDANT PG-401-1 TO BE CONNECTED TO 2C-34 & SCONCE LIGHTING PG-402 TO BE CONNECTED TO 2C-36 GENERAL BACK OF HOUSE LIGHTING TO BE CONNECTED TO 2C-42, EMERGENCY LIGHTING DENOTED WITH "E" SUFFIX OR SHOWN HALF SHADED TO BE CONNECTED TO EM3-4 VIA EMERGENCY TRANSFER DEVICE. STAIRWAY LIGHTING TO RUN 24/7 WITH INTEGRAL SENSOR TO REDUCE TO 50% WHEN UNOCCUPIED. LIGHTING TO BE CONNECTED AS FOLLOWS: STAIR 1: 2C-42/EM3-6 ALL EXIT LIGHTS ON GUEST SUITE FLOORS SHALL BE TYPE E3. Engi n ngir LLC8200 PEACHTREE AVE. ROCKFORD, MI 49341 P. 616-340-9627 SCALE: 1/8" = 1'-0" POWER & LIGHTING1 E202b ELEMENT SECOND FLOOR SCALE: 1/4" = 1'-0" ENLARGED POWER PLANA E202b ELEMENT SECOND FLOOR P:\2018\2018388 Aloft-Element Carmel\Working Drawings\E202b -Carmel DB.dwg, 5/26/2020 2:01:09 PM, cll09/28/20 DN UP DN UP 3C-1 - GENERAL CIRCUIT 3C-3 - BATHROOM CIRCUIT 3C-5 - MICROWAVE 3C-7/9 2P20A - VTAC CIRCUIT PG-401-1 PG-401-1 E E E E E E E E E E PG-401 PG-401 PG-401PG-401PG-401PG-401 PG-401 PG-401 PG-401 ALR-09 ALR-09 ALR-09 ALR-09ALR-09ALR-09 ALR-09ALR-09 ALR-09 ALR-09 ALR-09 ALR-09 ALR-09 ALR-09 ALR-09 ALR-09 ALR-09 ALR-09 ALR-09 3A-59 3A-9- GENERAL CIRCUIT 3A-11 BATHROOM CIRCUIT 3A-13/15 2P20A - VTAC CKT 3A-1 - GENERAL CIRCUIT 3A-3 - BATHROOM CIRCUIT 3A-5/7 2P20A - VTAC CKT 3A-25- GENERAL CIRCUIT 3A-27 BATHROOM CIRCUIT 3A-29/31 2P20A - VTAC CKT 3A-17 - GENERAL CIRCUIT 3A-19 - BATHROOM CIRCUIT 3A-21/23 2P20A - VTAC CKT 3A-33 - GENERAL CIRCUIT 3A-35 - BATHROOM CIRCUIT 3A-37/39 2P20A - VTAC CKT IR A2 A2 3A-55 3A-59 3A-593A-59 3A-57 3A-57 3A-57 3A-57 TO LIGHTS ABOVE FS TS FW1 FW1 8 3A-2 - GENERAL CIRCUIT 3A-4 - BATHROOM CIRCUIT 3A-6/8 2P20A - VTAC CKT 3A-10 - GENERAL CIRCUIT 3A-12 - BATHROOM CIRCUIT 3A-14/16 2P20A - VTAC CKT 3A-18 - GENERAL CIRCUIT 3A-20 - BATHROOM CIRCUIT 3A-22/24 2P20A - VTAC CKT 3A-26 - GENERAL CIRCUIT 3A-28 - BATHROOM CIRCUIT 3A-30/32 2P20A - VTAC CKT 3A-34 - GENERAL CIRCUIT 3A-36 - BATHROOM CIRCUIT 3A-38/40 2P20A - VTAC CKT 3A-44- GENERAL CIRCUIT 3A-46 - BATHROOM CIRCUIT 3A-48/50 2P20A - VTAC CKT 3A-43- GENERAL CIRCUIT 3A-45 - BATHROOM CIRCUIT 3A-47/49 2P30A - VTAC-2 CKT 3A-55 W A2 A2 A2 A2 A2 OS 3C-38 3C-38 3C-38 1 3C-38 J 3 F/SD 2 EM3-1 R-02R-02 W 3C-41 ALR-09 ALR-09 ALR-09 R-02 J4'EJ4 J4'E 3B-1 - GENERAL CIRCUIT 3B-3 - BATHROOM CIRCUIT 3B-5/7 2P20A - VTAC CKT 3B-2 - GENERAL CIRCUIT 3B-4 - BATHROOM CIRCUIT 3B-6/8 2P20A - VTAC CKT 3B-9- GENERAL CIRCUIT 3B-11 BATHROOM CIRCUIT 3B-13/15 2P20A - VTAC CKT 3B-17 - GENERAL CIRCUIT 3B-19 - BATHROOM CIRCUIT 3B-21/23 2P20A - VTAC CKT 3B-25- GENERAL CIRCUIT 3B-27 BATHROOM CIRCUIT 3B-29/31 2P20A - VTAC CKT 3B-10 - GENERAL CIRCUIT 3B-12 - BATHROOM CIRCUIT 3B-14/16 2P20A - VTAC CKT 3B-18 - GENERAL CIRCUIT 3B-20 - BATHROOM CIRCUIT 3B-22/24 2P20A - VTAC CKT 3B-26 - GENERAL CIRCUIT 3B-28 - BATHROOM CIRCUIT 3B-30/32 2P20A - VTAC CKT 3B-34 - GENERAL CIRCUIT 3B-36 - BATHROOM CIRCUIT 3B-38/40 2P20A - VTAC CKT 3B-33 - GENERAL CIRCUIT 3B-35 - BATHROOM CIRCUIT 3B-37/39 2P20A - VTAC CKT 3B-44- GENERAL CIRCUIT 3B-46 - BATHROOM CIRCUIT 3B-48/50 2P30A - VTAC-2 CKT 3B-43- GENERAL CIRCUIT 3B-45 - BATHROOM CIRCUIT 3B-47/49 2P20A - VTAC CKT W ELEMENTALOFT A E203A 3A-57 P RE:?/E5.0 EF- ALR-09 EXTERIOR LED STRIP LIGHTING. REFER TO ARCH ELEVATIONS FOR EXACT LOCATION. EXTERIOR LED STRIP LIGHTING. REFER TO ARCH ELEVATIONS FOR EXACT LOCATION. 8' EXTERIOR LED STRIP LIGHTING. REFER TO ARCH ELEVATIONS FOR EXACT LOCATION. XLR-12' XLR-X XLR-28' F 3C-35/37 FC-11 DH DH T T T T T T T T TT T T T T T T T TT T T T T T T T X118 X118 ALR-09 A2 112.5 KVA STUB (4) 4" C BETWEEN ALL FLOORS RE: 1/ET2.0 PROVIDE 4"X6" GROUND BAR, #8 AWG WIRE 3A-51 EM3-1 3A-51 BP3A T-3A 3A-55 BP3B 3/4" FIRE RATED PLY WOOD. HORIZONTAL MOUNTED CENTER ON WALL. PAINT TO MATCH COLOR OF ROOM. LEAVE FIRE SYMBOL SHOWING.P 3A-63,65 RE:B4/E501 DS-1 P 2A-61 RE:B1/E501 EF-4 T T GENERAL POWER NOTES: 1. 2. 3. 4. 5. 6. 7. POWER KEY NOTES: 1 2 3 4 5 6 7 ALL 15A & 20A 120V NON-LOCKING RECEPTACLES WITHIN CHILDCARE AREAS (AGES 7 & UNDER) SHALL BE LISTED TAMPER RESISTANT PER NEC 406.12. THIS INCLUDES GUEST ROOMS. MOUNT PANELS, TRANSFORMERS, DISCONNECT SWITCHES, AND COMBINATION MOTOR STARTERS WITH ADEQUATE CLEARANCES IN ACCORDANCE WITH NEC 110. VOLTAGE DROP TO MEET ASHRAE 90.1 (2007) ELEMENT ROOMS WHERE PANEL IS INDICATED - LABEL PANELS IN EACH ROOM WITH FINAL ROOM NUMBERS, COORDINATE WITH ARCHITECT FOR FINAL ROOM NUMBERING. DENOTED ON PLAN AS BPG (FLOOR #)-XX. "XX" DENOTE ROOM NUMBER INSTALL FIRE ALARM PER MARRIOTT'S MODULE 14 STANDARDS INSTALL PER LATEST NEC CODE: 2008 NEC NOT ALL POWER KEY NOTES ARE USED ON EACH FLOOR E.C. SHALL WIRE INTAKE DOORS FOR LAUNDRY CHUTE PER CHUTE MANUFACTURER'S ELECTRICAL INTERLOCK WIRING DIAGRAM. INSTALL AND WIRE MANUAL ON/OFF SWITCH, PROVIDED WITH UNIT IN LAUNDRY ROOM . SMOKE DETECTOR TO BE WIRED TO DOOR INTERLOCK SO THAT INTERLOCKS WILL NOT OPERATE UPON ACTIVATION OF SMOKE DETECTOR, TYPICAL EACH FLOOR. PROVIDE 120V POWER TO INTAKE DOOR AND RUN 4 WIRES BETWEEN FLOORS TO EACH INTAKE DOOR. CONNECT ALL SMOKE DAMPERS TO 120V CIRCUIT AS SHOWN, COORDINATE VOLTAGE WITH SUPPLIER. CONNECT TO FIRE ALARM SYSTEM. VERIFY QUANTITY AND LOCATIONS WITH MECHANICAL PLANS. PROVIDE TWO-WAY COMMUNICATION SYSTEMS. REFER TO SPEC SECTION 283100 AT RECEPTION DESK AND CENTRAL CONTROL UNIT IN MPF ROOM. CONTROL EF WITH LIGHT SWITCH REFER TO FOOD SERVICE ELECTRICAL PLANS FOR EQUIPMENT REQUIREMENTS AND MOUNTING HEIGHTS. EC TO PROVIDE AND INSTALL CORD AND PLUG, NEMA 5-20R ELEV. CAB LIGHT DISC. (1) 1P20A CKT BREAKER MTD IN NEMA-1 ENCLOSURE W/HANDLE PADLOCK ATTACHMENT CAPABLE OF LOCKING BREAKER IN OPEN POSITION. PROVIDE NAMEPLATE ON DISC. INDICATING PANEL NAME. COORDINATE LOCATIONS OF ALL EQUIPMENT IN ELEVATOR EQUIPMENT ROOM/HOIST ROOM AND PIT WITH ELEVATOR SHOP DRAWINGS PRIOR TO ROUGH-IN. CONNECT EMERGENCY SHUT-DOWN OF ELEVATOR AS REQUIRED. SEQUENCE EQUIPMENT TO SHUT-DOWN THE ELEVATOR BY SMOKE DETECTORS WHEN REQUIRED. ELECTRICAL CONTRACTOR SHALL REFERENCE ELEVATOR SPECIFICATIONS AND COORDINATE ALL REQUIREMENTS WITH ELEVATOR MANUFACTURER FOR ALL ELECTRICAL REQUIREMENTS PRIOR TO ROUGH-IN. COORDINATE QUANTITY & LOCATION OF FIRE SUPPRESSION RISERS AND TAMPER SWITCHES WITH FIRE SUPPRESSION PLANS. VERIFY WITH STATE CODE TO PROVIDE SMOKE DETECTION FOR ELEVATOR, PROVIDE AND INSTALLED BY E.C. CONNECT TO FIRE ALARM SYSTEM UNLESS NOT ALLOWED BY STATE CODE. PROVIDE POWER AND CONTROL TO SIGNAGE, VERIFY EXACT LOCATION WITH ARCHITECTURAL ELEVATIONS AND FINAL CONNECTIONS WITH SIGNAGE SHOP DRAWINGS 8 9 GENERAL LIGHTING NOTES: 1. 2. 3. 4. 5. 6. EGRESS ILLUMINATION LEVELS MEET NFPA 101 OR LOCAL CODE LIGHTING DESIGN COMPLIES WITH 2010 INDIANA ENERGY CODE/ASHRAE 90.1 2007 VOLTAGE DROP TO MEET ASHRAE 90.1 (2007) CONNECT CORRIDOR, ELEVATOR LOBBY AND CORRIDOR FIXTURES TO EMERGENCY CIRCUIT AND NORMAL CIRCUIT, RUN 24/7, REFER TO LIGHTING CONTROL SCHEDULE OR PLANS FOR CIRCUITING CONNECT EMERGENCY LIGHTING TO UL LISTED 924 EMERGENCY TRANSFER DEVICE FOR ALL EMERGENCY LOADS. EMERGENCY LIGHTING MAY BE GROUPED TOGETHER ON ONE TRANSFER DEVICE SIZED FOR LOAD PER LIGHTING ZONES. CONNECT EXIT SIGNS TO EMERGENCY LIGHTING CIRCUIT FEEDING LIGHTING IN AREA AHEAD OF SWITCHING. LIGHTING KEYNOTES: PROVIDE POWER TO SIGNAGE REFER TO ARCH ELEVATIONS. COORDINATE WITH FINAL SIGNAGE PLANS. LOCAL SWITCHES TO OVERRIDE OCCUPANCY SENSOR OFF FOR AV USAGE. PROVIDE LOCAL DIMMER SWITCH AT PANEL TO SET LIGHTING LEVEL AT ONSET OF JOB. PROVIDE DIMMING EMERGENCY TRANSFER DEVICE FOR DIMMED CORRIDOR LOADS TO BRING EMERGENCY CORRIDOR LIGHTING TO 100% IN GENERATOR MODE. LIGHTS RUN 24/7. L2 L1 L3 10 REFER TO THIS SHEET FOR GUEST SUITE POWER AND LIGHTING CIRCUITS. ALOFT: CORRIDOR LOW LEVEL WALL LIGHTS ALR09 TO BE CONNECTED TO CIRCUIT 4A-58/EM3-14. LIGHTING TO RUN 24/7. DECORATIVE PENDANT LIGHTING PG-401 TO BE CONNECTED TO 3A-58. GENERAL BACK OF HOUSE LIGHTING TO BE CONNECTED TO 3A-60, EMERGENCY LIGHTING DENOTED WITH "E" SUFFIX OR SHOWN HALF SHADED TO BE CONNECTED TO EM3-14 VIA EMERGENCY TRANSFER DEVICE. STAIRWAY LIGHTING TO RUN 24/7 WITH INTEGRAL SENSOR TO REDUCE TO 50% WHEN UNOCCUPIED. LIGHTING TO BE CONNECTED AS FOLLOWS: STAIR 2: 2A-62/EM3-8 ALL EXIT LIGHTS ON GUEST SUITE FLOORS SHALL BE TYPE E3. Engi n ngir LLC8200 PEACHTREE AVE. ROCKFORD, MI 49341 P. 616-340-9627 SCALE: 1/8" = 1'-0" POWER & LIGHTING1 E203a ALOFT THIRD FLOOR SCALE: 1/4" = 1'-0" ENLARGED POWER PLANA E203a ALOFT THIRD FLOOR P:\2018\2018388 Aloft-Element Carmel\Working Drawings\E203a -Carmel DB.dwg, 5/26/2020 2:02:27 PM, cll09/28/20 DN UP DN UP 3C-1 - GENERAL CIRCUIT 3C-3 - BATHROOM CIRCUIT 3C-5 - MICROWAVE 3C-7/9 2P20A - VTAC CIRCUIT 3C-11 - GENERAL CIRCUIT 3C-13 - BATHROOM CIRCUIT 3C-15 - MICROWAVE 3C-17/19 2P20A - VTAC CIRCUIT 3C-21 - GENERAL CIRCUIT 3C-23 - BATHROOM CIRCUIT 3C-25 - MICROWAVE 3C-27/29 2P20A - VTAC CIRCUIT BPG2 BPG2 3C-2- GENERAL CIRCUIT 3C-4- BATHROOM CIRCUIT 3C-6 - MICROWAVE 3C-8/10 2P20A - VTAC CIRCUIT 3C-12 - GENERAL CIRCUIT 3C-14 - BATHROOM CIRCUIT 3C-16 - MICROWAVE 3C-18/20 2P20A - VTAC CIRCUIT BPG3 BPG3 3C-22 - GENERAL CIRCUIT 3C-24 - BATHROOM CIRCUIT 3C-26 - MICROWAVE 3C-28/30 2P20A - VTAC CIRCUIT BPG2 BPG2 BPG2 BPG2 BPG2 BPG2 BPG2 BPG2 BPG2 PG-401-1 R-02 PG-402 PG-401-1 PG-401-1 R-02 R-02 R-02 R-02 R-02 R-02R-02 R-02R-02 R-02R-02 PG-402 PG-402 PG-402 PG-402 PG-402 PG-401-1 PG-401-1 PG-401-1 PG-401-1 PG-401-1PG-401-1 PG-401-1 PG-401-1 PG-401-1 PG-401-1 PG-402 PG-402 PG-402 PG-402 3C-41 3C-41 E E E E E E E 3C-41 3C-41 3C-32 3C-32 3C-32 3C-32 3C-32 IR A2 A2 3C-40 3C-40 J4'E J4 J4'E TO LIGHTS ABOVE FS TS FW1 FW1 8 3C-32 W A2 A2 A2 OS 3C-38 W R-02R-02 ELEMENT ALOFT A E203B PG-402PG-402 PG-402 PG-402 PG-402 PG-402 F/SD 2 EM1-3 3C-32 BPG2 F 3C-35/37 FC-11 DH T T T T T T T TT T T T T T T T T T BPG2 PG-402 PG-402 PG-402 PG-402 PG-402 150 KVA 3/4" FIRE RATED PLY WOOD. HORIZONTAL MOUNTED CENTER ON WALL. PAINT TO MATCH COLOR OF ROOM. LEAVE FIRE SYMBOL SHOWING. STUB (4) 4" C BETWEEN ALL FLOORS RE: 1/ET2.0 PROVIDE 4"X6" GROUND BAR, #8 AWG WIRE 3C-31EM3-7 3C-32 BP3C T-3B SDP3B 3C-40 P 3PB-53,55 RE:B4/501 DS-1 P 3B-51 RE:B1/501 EF-4 T GENERAL POWER NOTES: 1. 2. 3. 4. 5. 6. 7. POWER KEY NOTES: 1 2 3 4 5 6 7 ALL 15A & 20A 120V NON-LOCKING RECEPTACLES WITHIN CHILDCARE AREAS (AGES 7 & UNDER) SHALL BE LISTED TAMPER RESISTANT PER NEC 406.12. THIS INCLUDES GUEST ROOMS. MOUNT PANELS, TRANSFORMERS, DISCONNECT SWITCHES, AND COMBINATION MOTOR STARTERS WITH ADEQUATE CLEARANCES IN ACCORDANCE WITH NEC 110. VOLTAGE DROP TO MEET ASHRAE 90.1 (2007) ELEMENT ROOMS WHERE PANEL IS INDICATED - LABEL PANELS IN EACH ROOM WITH FINAL ROOM NUMBERS, COORDINATE WITH ARCHITECT FOR FINAL ROOM NUMBERING. DENOTED ON PLAN AS BPG (FLOOR #)-XX. "XX" DENOTE ROOM NUMBER INSTALL FIRE ALARM PER MARRIOTT'S MODULE 14 STANDARDS INSTALL PER LATEST NEC CODE: 2008 NEC NOT ALL POWER KEY NOTES ARE USED ON EACH FLOOR E.C. SHALL WIRE INTAKE DOORS FOR LAUNDRY CHUTE PER CHUTE MANUFACTURER'S ELECTRICAL INTERLOCK WIRING DIAGRAM. INSTALL AND WIRE MANUAL ON/OFF SWITCH, PROVIDED WITH UNIT IN LAUNDRY ROOM . SMOKE DETECTOR TO BE WIRED TO DOOR INTERLOCK SO THAT INTERLOCKS WILL NOT OPERATE UPON ACTIVATION OF SMOKE DETECTOR, TYPICAL EACH FLOOR. PROVIDE 120V POWER TO INTAKE DOOR AND RUN 4 WIRES BETWEEN FLOORS TO EACH INTAKE DOOR. CONNECT ALL SMOKE DAMPERS TO 120V CIRCUIT AS SHOWN, COORDINATE VOLTAGE WITH SUPPLIER. CONNECT TO FIRE ALARM SYSTEM. VERIFY QUANTITY AND LOCATIONS WITH MECHANICAL PLANS. PROVIDE TWO-WAY COMMUNICATION SYSTEMS. REFER TO SPEC SECTION 283100 AT RECEPTION DESK AND CENTRAL CONTROL UNIT IN MPF ROOM. CONTROL EF WITH LIGHT SWITCH REFER TO FOOD SERVICE ELECTRICAL PLANS FOR EQUIPMENT REQUIREMENTS AND MOUNTING HEIGHTS. EC TO PROVIDE AND INSTALL CORD AND PLUG, NEMA 5-20R ELEV. CAB LIGHT DISC. (1) 1P20A CKT BREAKER MTD IN NEMA-1 ENCLOSURE W/HANDLE PADLOCK ATTACHMENT CAPABLE OF LOCKING BREAKER IN OPEN POSITION. PROVIDE NAMEPLATE ON DISC. INDICATING PANEL NAME. COORDINATE LOCATIONS OF ALL EQUIPMENT IN ELEVATOR EQUIPMENT ROOM/HOIST ROOM AND PIT WITH ELEVATOR SHOP DRAWINGS PRIOR TO ROUGH-IN. CONNECT EMERGENCY SHUT-DOWN OF ELEVATOR AS REQUIRED. SEQUENCE EQUIPMENT TO SHUT-DOWN THE ELEVATOR BY SMOKE DETECTORS WHEN REQUIRED. ELECTRICAL CONTRACTOR SHALL REFERENCE ELEVATOR SPECIFICATIONS AND COORDINATE ALL REQUIREMENTS WITH ELEVATOR MANUFACTURER FOR ALL ELECTRICAL REQUIREMENTS PRIOR TO ROUGH-IN. COORDINATE QUANTITY & LOCATION OF FIRE SUPPRESSION RISERS AND TAMPER SWITCHES WITH FIRE SUPPRESSION PLANS. VERIFY WITH STATE CODE TO PROVIDE SMOKE DETECTION FOR ELEVATOR, PROVIDE AND INSTALLED BY E.C. CONNECT TO FIRE ALARM SYSTEM UNLESS NOT ALLOWED BY STATE CODE. PROVIDE POWER AND CONTROL TO SIGNAGE, VERIFY EXACT LOCATION WITH ARCHITECTURAL ELEVATIONS AND FINAL CONNECTIONS WITH SIGNAGE SHOP DRAWINGS 8 9 GENERAL LIGHTING NOTES: 1. 2. 3. 4. 5. 6. EGRESS ILLUMINATION LEVELS MEET NFPA 101 OR LOCAL CODE LIGHTING DESIGN COMPLIES WITH 2010 INDIANA ENERGY CODE/ASHRAE 90.1 2007 VOLTAGE DROP TO MEET ASHRAE 90.1 (2007) CONNECT CORRIDOR, ELEVATOR LOBBY AND CORRIDOR FIXTURES TO EMERGENCY CIRCUIT AND NORMAL CIRCUIT, RUN 24/7, REFER TO LIGHTING CONTROL SCHEDULE OR PLANS FOR CIRCUITING CONNECT EMERGENCY LIGHTING TO UL LISTED 924 EMERGENCY TRANSFER DEVICE FOR ALL EMERGENCY LOADS. EMERGENCY LIGHTING MAY BE GROUPED TOGETHER ON ONE TRANSFER DEVICE SIZED FOR LOAD PER LIGHTING ZONES. CONNECT EXIT SIGNS TO EMERGENCY LIGHTING CIRCUIT FEEDING LIGHTING IN AREA AHEAD OF SWITCHING. LIGHTING KEYNOTES: PROVIDE POWER TO SIGNAGE REFER TO ARCH ELEVATIONS. COORDINATE WITH FINAL SIGNAGE PLANS. LOCAL SWITCHES TO OVERRIDE OCCUPANCY SENSOR OFF FOR AV USAGE. PROVIDE LOCAL DIMMER SWITCH AT PANEL TO SET LIGHTING LEVEL AT ONSET OF JOB. PROVIDE DIMMING EMERGENCY TRANSFER DEVICE FOR DIMMED CORRIDOR LOADS TO BRING EMERGENCY CORRIDOR LIGHTING TO 100% IN GENERATOR MODE. LIGHTS RUN 24/7. L2 L1 L3 10 REFER TO SHEETE E612 FOR POWER AND LIGHTING CIRCUITS IN PANELS BP-G2 AND BP-G3. ALL OTHER GUEST SUITES WITHOUT A ROOM ELECTRICAL PANEL, CIRCUITS FOR POWER AND LIGHTING NOTED ON THIS PLAN. ELEMENT: CORRIDOR DOWNLIGHTS R-02 TO BE CONNECTED TO CIRCUIT 3C-34/EM3-16. LIGHTING TO RUN 24/7. REFER TO KEY NOTE L3 DECORATIVE PENDANT PG-401-1 TO BE CONNECTED TO 3C-34 & SCONCE LIGHTING PG-402 TO BE CONNECTED TO 3C-36 GENERAL BACK OF HOUSE LIGHTING TO BE CONNECTED TO 3C-42, EMERGENCY LIGHTING DENOTED WITH "E" SUFFIX OR SHOWN HALF SHADED TO BE CONNECTED TO EM3-16 VIA EMERGENCY TRANSFER DEVICE. STAIRWAY LIGHTING TO RUN 24/7 WITH INTEGRAL SENSOR TO REDUCE TO 50% WHEN UNOCCUPIED. LIGHTING TO BE CONNECTED AS FOLLOWS: STAIR 1: 2C-42/EM3-6 ALL EXIT LIGHTS ON GUEST FLOORS SHALL BE TYPE E3. Engi n ngir LLC8200 PEACHTREE AVE. ROCKFORD, MI 49341 P. 616-340-9627 SCALE: 1/8" = 1'-0" POWER & LIGHTING1 E203b ELEMENT THIRD FLOOR SCALE: 1/4" = 1'-0" ENLARGED POWER PLANA E203b ELEMENT THIRD FLOOR P:\2018\2018388 Aloft-Element Carmel\Working Drawings\E203b -Carmel DB.dwg, 5/26/2020 2:03:48 PM, cll09/28/20 DN UP DN UP 4C-1 - GENERAL CIRCUIT 4C-3 - BATHROOM CIRCUIT 4C-5 - MICROWAVE 4C-7/9 2P20A - VTAC CIRCUIT PG-401-1 PG-401-1 E E E E E E E E E E PG-401 PG-401 PG-401PG-401PG-401 PG-401 PG-401 PG-401 PG-401 ALR-09 ALR-09 ALR-09 ALR-09ALR-09ALR-09 ALR-09ALR-09 ALR-09 ALR-09 ALR-09 ALR-09 ALR-09 ALR-09 ALR-09 ALR-09 ALR-09 ALR-09 ALR-09 4A-59 4A-9- GENERAL CIRCUIT 4A-11 BATHROOM CIRCUIT 4A-13/15 2P20A - VTAC CKT 4A-1 - GENERAL CIRCUIT 4A-3 - BATHROOM CIRCUIT 4A-5/7 2P20A - VTAC CKT 4A-25- GENERAL CIRCUIT 4A-27 BATHROOM CIRCUIT 4A-29/31 2P20A - VTAC CKT 4A-17 - GENERAL CIRCUIT 4A-19 - BATHROOM CIRCUIT 4A-21/23 2P20A - VTAC CKT 4A-33 - GENERAL CIRCUIT 4A-35 - BATHROOM CIRCUIT 4A-37/39 2P20A - VTAC CKT IR A2 4A-55 4A-59 4A-594A-59 4A-57 4A-57 4A-57 4A-57 TO LIGHTS ABOVE FS TS FW1 FW1 8 4A-2 - GENERAL CIRCUIT 4A-4 - BATHROOM CIRCUIT 4A-6/8 2P20A - VTAC CKT 4A-10 - GENERAL CIRCUIT 4A-12 - BATHROOM CIRCUIT 4A-14/16 2P20A - VTAC CKT 4A-18 - GENERAL CIRCUIT 4A-20 - BATHROOM CIRCUIT 4A-22/24 2P20A - VTAC CKT 4A-26 - GENERAL CIRCUIT 4A-28 - BATHROOM CIRCUIT 4A-30/32 2P20A - VTAC CKT 4A-34 - GENERAL CIRCUIT 4A-36 - BATHROOM CIRCUIT 4A-38/40 2P20A - VTAC CKT 4A-44- GENERAL CIRCUIT 4A-46 - BATHROOM CIRCUIT 4A-48/50 2P20A - VTAC CKT 4A-71- GENERAL CIRCUIT 4A-73 - BATHROOM CIRCUIT 4A-75 - BEDROOM CIRCUIT 4A-77/79 2P20A - VTAC CKT W A2 A2 A2 A2 A2 OS 4C-38 4C-38 4C-38 1 4C-38 J 3 F/SD 2 EM3-9 R-02R-02 W 4C-41 ALR-09 ALR-09 ALR-09 R-02 J4'EJ4J4'E STUB (4) 4" C BETWEEN ALL FLOORS RE: 1/ET2.0 PROVIDE 4"X6" GROUND BAR, #8 AWG WIRE 4A-51 EM3-1 4A-51 4A-55 4B-1 - GENERAL CIRCUIT 4B-3 - BATHROOM CIRCUIT 4B-5/7 2P20A - VTAC CKT 4B-2 - GENERAL CIRCUIT 4B-4 - BATHROOM CIRCUIT 4B-6/8 2P20A - VTAC CKT 4B-9- GENERAL CIRCUIT 4B-11 BATHROOM CIRCUIT 4B-13/15 2P20A - VTAC CKT 4B-17 - GENERAL CIRCUIT 4B-19 - BATHROOM CIRCUIT 4B-21/23 2P20A - VTAC CKT 4B-25- GENERAL CIRCUIT 4B-27 BATHROOM CIRCUIT 4B-29/31 2P20A - VTAC CKT 4B-10 - GENERAL CIRCUIT 4B-12 - BATHROOM CIRCUIT 4B-14/16 2P20A - VTAC CKT 4B-18 - GENERAL CIRCUIT 4B-20 - BATHROOM CIRCUIT 4B-22/24 2P20A - VTAC CKT 4B-26 - GENERAL CIRCUIT 4B-28 - BATHROOM CIRCUIT 4B-30/32 2P20A - VTAC CKT 4B-34 - GENERAL CIRCUIT 4B-36 - BATHROOM CIRCUIT 4B-38/40 2P20A - VTAC CKT 4B-33 - GENERAL CIRCUIT 4B-35 - BATHROOM CIRCUIT 4B-37/39 2P20A - VTAC CKT 4B-44- GENERAL CIRCUIT 4B-46 - BATHROOM CIRCUIT 4B-48/50 2P20A - VTAC CKT 4B-43- GENERAL CIRCUIT 4B-45 - BATHROOM CIRCUIT 4B-47/49 2P20A - VTAC CKT W 3/4" FIRE RATED PLY WOOD. HORIZONTAL MOUNTED CENTER ON WALL. PAINT TO MATCH COLOR OF ROOM. LEAVE FIRE SYMBOL SHOWING. ELEMENTALOFT A E204A 4A-57 P 4A-67 EF-9 P RE:?/E5.0 EF- ALR-09 4A-61 IREXTERIOR LED STRIP LIGHTING. REFER TO ARCH ELEVATIONS FOR EXACT LOCATION. EXTERIOR LED STRIP LIGHTING. REFER TO ARCH ELEVATIONS FOR EXACT LOCATION. XLR-38' XLR-38' T DH DH 9 9 R-02 T T T T T T T T TT T T T T T T T TT T T T T T T T X610 X610 F 4C-63/65 FC-12 ALR-09 A2 112.5 KVA STUB (4) 4" C BETWEEN ALL FLOORS RE: 1/ET2.0 PROVIDE 4"X6" GROUND BAR, #8 AWG WIRE 4A-51 EM3-1 4A-51 BP4A T-4A 4A-55 W BP4B 3/4" FIRE RATED PLY WOOD. HORIZONTAL MOUNTED CENTER ON WALL. PAINT TO MATCH COLOR OF ROOM. LEAVE FIRE SYMBOL SHOWING.P 4A-63,65 RE:B4/501 DS-1 P BPA-67 RE:B1/501 EF-4 T T GENERAL POWER NOTES: 1. 2. 3. 4. 5. 6. 7. POWER KEY NOTES: 1 2 3 4 5 6 7 ALL 15A & 20A 120V NON-LOCKING RECEPTACLES WITHIN CHILDCARE AREAS (AGES 7 & UNDER) SHALL BE LISTED TAMPER RESISTANT PER NEC 406.12. THIS INCLUDES GUEST ROOMS. MOUNT PANELS, TRANSFORMERS, DISCONNECT SWITCHES, AND COMBINATION MOTOR STARTERS WITH ADEQUATE CLEARANCES IN ACCORDANCE WITH NEC 110. VOLTAGE DROP TO MEET ASHRAE 90.1 (2007) ELEMENT ROOMS WHERE PANEL IS INDICATED - LABEL PANELS IN EACH ROOM WITH FINAL ROOM NUMBERS, COORDINATE WITH ARCHITECT FOR FINAL ROOM NUMBERING. DENOTED ON PLAN AS BPG (FLOOR #)-XX. "XX" DENOTE ROOM NUMBER INSTALL FIRE ALARM PER MARRIOTT'S MODULE 14 STANDARDS INSTALL PER LATEST NEC CODE: 2008 NEC NOT ALL POWER KEY NOTES ARE USED ON EACH FLOOR E.C. SHALL WIRE INTAKE DOORS FOR LAUNDRY CHUTE PER CHUTE MANUFACTURER'S ELECTRICAL INTERLOCK WIRING DIAGRAM. INSTALL AND WIRE MANUAL ON/OFF SWITCH, PROVIDED WITH UNIT IN LAUNDRY ROOM . SMOKE DETECTOR TO BE WIRED TO DOOR INTERLOCK SO THAT INTERLOCKS WILL NOT OPERATE UPON ACTIVATION OF SMOKE DETECTOR, TYPICAL EACH FLOOR. PROVIDE 120V POWER TO INTAKE DOOR AND RUN 4 WIRES BETWEEN FLOORS TO EACH INTAKE DOOR. CONNECT ALL SMOKE DAMPERS TO 120V CIRCUIT AS SHOWN, COORDINATE VOLTAGE WITH SUPPLIER. CONNECT TO FIRE ALARM SYSTEM. VERIFY QUANTITY AND LOCATIONS WITH MECHANICAL PLANS. PROVIDE TWO-WAY COMMUNICATION SYSTEMS. REFER TO SPEC SECTION 283100 AT RECEPTION DESK AND CENTRAL CONTROL UNIT IN MPF ROOM. CONTROL EF WITH LIGHT SWITCH REFER TO FOOD SERVICE ELECTRICAL PLANS FOR EQUIPMENT REQUIREMENTS AND MOUNTING HEIGHTS. EC TO PROVIDE AND INSTALL CORD AND PLUG, NEMA 5-20R ELEV. CAB LIGHT DISC. (1) 1P20A CKT BREAKER MTD IN NEMA-1 ENCLOSURE W/HANDLE PADLOCK ATTACHMENT CAPABLE OF LOCKING BREAKER IN OPEN POSITION. PROVIDE NAMEPLATE ON DISC. INDICATING PANEL NAME. COORDINATE LOCATIONS OF ALL EQUIPMENT IN ELEVATOR EQUIPMENT ROOM/HOIST ROOM AND PIT WITH ELEVATOR SHOP DRAWINGS PRIOR TO ROUGH-IN. CONNECT EMERGENCY SHUT-DOWN OF ELEVATOR AS REQUIRED. SEQUENCE EQUIPMENT TO SHUT-DOWN THE ELEVATOR BY SMOKE DETECTORS WHEN REQUIRED. ELECTRICAL CONTRACTOR SHALL REFERENCE ELEVATOR SPECIFICATIONS AND COORDINATE ALL REQUIREMENTS WITH ELEVATOR MANUFACTURER FOR ALL ELECTRICAL REQUIREMENTS PRIOR TO ROUGH-IN. COORDINATE QUANTITY & LOCATION OF FIRE SUPPRESSION RISERS AND TAMPER SWITCHES WITH FIRE SUPPRESSION PLANS. VERIFY WITH STATE CODE TO PROVIDE SMOKE DETECTION FOR ELEVATOR, PROVIDE AND INSTALLED BY E.C. CONNECT TO FIRE ALARM SYSTEM UNLESS NOT ALLOWED BY STATE CODE. PROVIDE POWER AND CONTROL TO SIGNAGE, VERIFY EXACT LOCATION WITH ARCHITECTURAL ELEVATIONS AND FINAL CONNECTIONS WITH SIGNAGE SHOP DRAWINGS 8 9 GENERAL LIGHTING NOTES: 1. 2. 3. 4. 5. 6. EGRESS ILLUMINATION LEVELS MEET NFPA 101 OR LOCAL CODE LIGHTING DESIGN COMPLIES WITH 2010 INDIANA ENERGY CODE/ASHRAE 90.1 2007 VOLTAGE DROP TO MEET ASHRAE 90.1 (2007) CONNECT CORRIDOR, ELEVATOR LOBBY AND CORRIDOR FIXTURES TO EMERGENCY CIRCUIT AND NORMAL CIRCUIT, RUN 24/7, REFER TO LIGHTING CONTROL SCHEDULE OR PLANS FOR CIRCUITING CONNECT EMERGENCY LIGHTING TO UL LISTED 924 EMERGENCY TRANSFER DEVICE FOR ALL EMERGENCY LOADS. EMERGENCY LIGHTING MAY BE GROUPED TOGETHER ON ONE TRANSFER DEVICE SIZED FOR LOAD PER LIGHTING ZONES. CONNECT EXIT SIGNS TO EMERGENCY LIGHTING CIRCUIT FEEDING LIGHTING IN AREA AHEAD OF SWITCHING. LIGHTING KEYNOTES: PROVIDE POWER TO SIGNAGE REFER TO ARCH ELEVATIONS. COORDINATE WITH FINAL SIGNAGE PLANS. LOCAL SWITCHES TO OVERRIDE OCCUPANCY SENSOR OFF FOR AV USAGE. PROVIDE LOCAL DIMMER SWITCH AT PANEL TO SET LIGHTING LEVEL AT ONSET OF JOB. PROVIDE DIMMING EMERGENCY TRANSFER DEVICE FOR DIMMED CORRIDOR LOADS TO BRING EMERGENCY CORRIDOR LIGHTING TO 100% IN GENERATOR MODE. LIGHTS RUN 24/7. L2 L1 L3 10 REFER TO THIS SHEET FOR GUEST SUITE POWER AND LIGHTING CIRCUITS. ALOFT: CORRIDOR LOW LEVEL WALL LIGHTS ALR09 TO BE CONNECTED TO CIRCUIT 4A-58/EM3-14. LIGHTING TO RUN 24/7. DECORATIVE PENDANT LIGHTING PG-401 TO BE CONNECTED TO 4A-58. GENERAL BACK OF HOUSE LIGHTING TO BE CONNECTED TO 4A-60, EMERGENCY LIGHTING DENOTED WITH "E" SUFFIX OR SHOWN HALF SHADED TO BE CONNECTED TO EM3-14 VIA EMERGENCY TRANSFER DEVICE. STAIRWAY LIGHTING TO RUN 24/7 WITH INTEGRAL SENSOR TO REDUCE TO 50% WHEN UNOCCUPIED. LIGHTING TO BE CONNECTED AS FOLLOWS: STAIR 2: 2A-62/EM3-8 ALL EXIT LIGHTS ON GUEST SUITE FLOORS SHALL BE TYPE E3. Engi n ngir LLC8200 PEACHTREE AVE. ROCKFORD, MI 49341 P. 616-340-9627 SCALE: 1/8" = 1'-0" POWER & LIGHTING1 E204a ALOFT FOURTH FLOOR SCALE: 1/4" = 1'-0" ENLARGED POWER PLANA E204a ALOFT FOURTH FLOOR P:\2018\2018388 Aloft-Element Carmel\Working Drawings\E204a -Carmel DB.dwg, 5/26/2020 2:08:04 PM, cll09/28/20 DN UP DN UP 4C-1 - GENERAL CIRCUIT 4C-3 - BATHROOM CIRCUIT 4C-5 - MICROWAVE 4C-7/9 2P20A - VTAC CIRCUIT 4C-11 - GENERAL CIRCUIT 4C-13 - BATHROOM CIRCUIT 4C-15 - MICROWAVE 4C-17/19 2P20A - VTAC CIRCUIT 4C-21 - GENERAL CIRCUIT 4C-23 - BATHROOM CIRCUIT 4C-25 - MICROWAVE 4C-27/29 2P20A - VTAC CIRCUIT BPG2 BPG2 4C-2- GENERAL CIRCUIT 4C-4- BATHROOM CIRCUIT 4C-6 - MICROWAVE 4C-8/10 2P20A - VTAC CIRCUIT 4C-12 - GENERAL CIRCUIT 4C-14 - BATHROOM CIRCUIT 4C-16 - MICROWAVE 4C-18/20 2P20A - VTAC CIRCUIT BPG2 BPG2 4C-22 - GENERAL CIRCUIT 4C-24 - BATHROOM CIRCUIT 4C-26 - MICROWAVE 4C-28/30 2P20A - VTAC CIRCUIT BPG2 BPG2 BPG2 BPG2 BPG2 BPG3 R-02 PG-402 PG-401-1 R-02 R-02 R-02 R-02 R-02R-02 R-02R-02 R-02R-02 PG-402 PG-402 PG-402 PG-402 PG-402 PG-401-1 PG-401-1 PG-401-1 PG-401-1PG-401-1PG-401-1 PG-401-1 PG-401-1 PG-401-1 PG-401-1 4C-41 4C-41 E E E E E E E 4C-41 4C-41 4C-32 4C-32 4C-32 4C-32 IR A2 A2 4C-40 4C-40 J4'E J4 J4'E TO LIGHTS ABOVE FS TS FW1 FW1 8 4C-32 W A2 A2 A2 OS 4C-38 W R-02R-02 ELEMENTALOFT A E204B PG-402 PG-402PG-402 PG-402 F/SD 2 EM3-11 B E204B BPG2 4C-53 - GENERAL CIRCUIT 4C-55 - BATHROOM CIRCUIT 4C-56 - MICROWAVE 4C-58/60 2P20A - VTAC CIRCUIT 4C-44 - GENERAL CIRCUIT 4C-46 - BATHROOM CIRCUIT 4C-48 - MICROWAVE 4C-50/52 2P20A - VTAC CIRCUIT 4C-54 - GENERAL CIRCUIT 4C-56 - BATHROOM CIRCUIT 4C-58 - MICROWAVE CIRCUIT 4C-60/62 2P20A - VTAC CKT G3-15 - GENERAL CIRCUIT G3-17 - BATHROOM CIRCUIT G3-19 - MICROWAVE G3-14/16 2P20A - VTAC CIRCUIT DH T T T T T T T TT T T T T T T T T T TT T F 4C-63/65 FC-12 PG-402 PG-402 PG-402 PG-402 PG-402 R-02 150 KVA 3/4" FIRE RATED PLY WOOD. HORIZONTAL MOUNTED CENTER ON WALL. PAINT TO MATCH COLOR OF ROOM. LEAVE FIRE SYMBOL SHOWING. STUB (4) 4" C BETWEEN ALL FLOORS RE: 1/ET2.0 PROVIDE 4"X6" GROUND BAR, #8 AWG WIRE 4C-31EM1-13 4C-32 T-4C SDP4B 4C-40 P 4B-53,55 RE:B2/E5.0 DS-1 P 4B-51 RE:C2/E5.0 EF-4 BP-4C T ALR-02 X400 X400 ALR-02 ALR-02 ALR-02 ALR-02 ALR-02 FRIG 3G-5 OVEN 2P40 3G-9/11 MICRO G3-13 HOOD G3-3 IRD IRD G3-8 DW TV ALR-02 AC ACACAC AC G3-1 3G-1 G3-1 G3-1 G3-18 G3-18 4C-39 G3-16 G3-18 G3-18 G3-12 G3-8 VTAC G3-4/6 2P20 G3-10 G3-10 T TV60" 60" J POKE THRU POKE THRU T GENERAL POWER NOTES: 1. 2. 3. 4. 5. 6. 7. POWER KEY NOTES: 1 2 3 4 5 6 7 ALL 15A & 20A 120V NON-LOCKING RECEPTACLES WITHIN CHILDCARE AREAS (AGES 7 & UNDER) SHALL BE LISTED TAMPER RESISTANT PER NEC 406.12. THIS INCLUDES GUEST ROOMS. MOUNT PANELS, TRANSFORMERS, DISCONNECT SWITCHES, AND COMBINATION MOTOR STARTERS WITH ADEQUATE CLEARANCES IN ACCORDANCE WITH NEC 110. VOLTAGE DROP TO MEET ASHRAE 90.1 (2007) ELEMENT ROOMS WHERE PANEL IS INDICATED - LABEL PANELS IN EACH ROOM WITH FINAL ROOM NUMBERS, COORDINATE WITH ARCHITECT FOR FINAL ROOM NUMBERING. DENOTED ON PLAN AS BPG (FLOOR #)-XX. "XX" DENOTE ROOM NUMBER INSTALL FIRE ALARM PER MARRIOTT'S MODULE 14 STANDARDS INSTALL PER LATEST NEC CODE: 2008 NEC NOT ALL POWER KEY NOTES ARE USED ON EACH FLOOR E.C. SHALL WIRE INTAKE DOORS FOR LAUNDRY CHUTE PER CHUTE MANUFACTURER'S ELECTRICAL INTERLOCK WIRING DIAGRAM. INSTALL AND WIRE MANUAL ON/OFF SWITCH, PROVIDED WITH UNIT IN LAUNDRY ROOM . SMOKE DETECTOR TO BE WIRED TO DOOR INTERLOCK SO THAT INTERLOCKS WILL NOT OPERATE UPON ACTIVATION OF SMOKE DETECTOR, TYPICAL EACH FLOOR. PROVIDE 120V POWER TO INTAKE DOOR AND RUN 4 WIRES BETWEEN FLOORS TO EACH INTAKE DOOR. CONNECT ALL SMOKE DAMPERS TO 120V CIRCUIT AS SHOWN, COORDINATE VOLTAGE WITH SUPPLIER. CONNECT TO FIRE ALARM SYSTEM. VERIFY QUANTITY AND LOCATIONS WITH MECHANICAL PLANS. PROVIDE TWO-WAY COMMUNICATION SYSTEMS. REFER TO SPEC SECTION 283100 AT RECEPTION DESK AND CENTRAL CONTROL UNIT IN MPF ROOM. CONTROL EF WITH LIGHT SWITCH REFER TO FOOD SERVICE ELECTRICAL PLANS FOR EQUIPMENT REQUIREMENTS AND MOUNTING HEIGHTS. EC TO PROVIDE AND INSTALL CORD AND PLUG, NEMA 5-20R ELEV. CAB LIGHT DISC. (1) 1P20A CKT BREAKER MTD IN NEMA-1 ENCLOSURE W/HANDLE PADLOCK ATTACHMENT CAPABLE OF LOCKING BREAKER IN OPEN POSITION. PROVIDE NAMEPLATE ON DISC. INDICATING PANEL NAME. COORDINATE LOCATIONS OF ALL EQUIPMENT IN ELEVATOR EQUIPMENT ROOM/HOIST ROOM AND PIT WITH ELEVATOR SHOP DRAWINGS PRIOR TO ROUGH-IN. CONNECT EMERGENCY SHUT-DOWN OF ELEVATOR AS REQUIRED. SEQUENCE EQUIPMENT TO SHUT-DOWN THE ELEVATOR BY SMOKE DETECTORS WHEN REQUIRED. ELECTRICAL CONTRACTOR SHALL REFERENCE ELEVATOR SPECIFICATIONS AND COORDINATE ALL REQUIREMENTS WITH ELEVATOR MANUFACTURER FOR ALL ELECTRICAL REQUIREMENTS PRIOR TO ROUGH-IN. COORDINATE QUANTITY & LOCATION OF FIRE SUPPRESSION RISERS AND TAMPER SWITCHES WITH FIRE SUPPRESSION PLANS. VERIFY WITH STATE CODE TO PROVIDE SMOKE DETECTION FOR ELEVATOR, PROVIDE AND INSTALLED BY E.C. CONNECT TO FIRE ALARM SYSTEM UNLESS NOT ALLOWED BY STATE CODE. PROVIDE POWER AND CONTROL TO SIGNAGE, VERIFY EXACT LOCATION WITH ARCHITECTURAL ELEVATIONS AND FINAL CONNECTIONS WITH SIGNAGE SHOP DRAWINGS 8 9 GENERAL LIGHTING NOTES: 1. 2. 3. 4. 5. 6. EGRESS ILLUMINATION LEVELS MEET NFPA 101 OR LOCAL CODE LIGHTING DESIGN COMPLIES WITH 2010 INDIANA ENERGY CODE/ASHRAE 90.1 2007 VOLTAGE DROP TO MEET ASHRAE 90.1 (2007) CONNECT CORRIDOR, ELEVATOR LOBBY AND CORRIDOR FIXTURES TO EMERGENCY CIRCUIT AND NORMAL CIRCUIT, RUN 24/7, REFER TO LIGHTING CONTROL SCHEDULE OR PLANS FOR CIRCUITING CONNECT EMERGENCY LIGHTING TO UL LISTED 924 EMERGENCY TRANSFER DEVICE FOR ALL EMERGENCY LOADS. EMERGENCY LIGHTING MAY BE GROUPED TOGETHER ON ONE TRANSFER DEVICE SIZED FOR LOAD PER LIGHTING ZONES. CONNECT EXIT SIGNS TO EMERGENCY LIGHTING CIRCUIT FEEDING LIGHTING IN AREA AHEAD OF SWITCHING. LIGHTING KEYNOTES: PROVIDE POWER TO SIGNAGE REFER TO ARCH ELEVATIONS. COORDINATE WITH FINAL SIGNAGE PLANS. LOCAL SWITCHES TO OVERRIDE OCCUPANCY SENSOR OFF FOR AV USAGE. PROVIDE LOCAL DIMMER SWITCH AT PANEL TO SET LIGHTING LEVEL AT ONSET OF JOB. PROVIDE DIMMING EMERGENCY TRANSFER DEVICE FOR DIMMED CORRIDOR LOADS TO BRING EMERGENCY CORRIDOR LIGHTING TO 100% IN GENERATOR MODE. LIGHTS RUN 24/7. L2 L1 L3 10 REFER TO SHEETE E612 FOR POWER AND LIGHTING CIRCUITS IN PANELS BP-G2 AND BP-G3. ALL OTHER GUEST SUITES WITHOUT A ROOM ELECTRICAL PANEL, CIRCUITS FOR POWER AND LIGHTING NOTED ON THIS PLAN. ELEMENT: CORRIDOR DOWNLIGHTS R-02 TO BE CONNECTED TO CIRCUIT 4C-34/EM3-16. LIGHTING TO RUN 24/7. REFER TO KEY NOTE L3 DECORATIVE PENDANT PG-401-1 TO BE CONNECTED TO 4C-34 & SCONCE LIGHTING PG-402 TO BE CONNECTED TO 4C-36 GENERAL BACK OF HOUSE LIGHTING TO BE CONNECTED TO 4C-42, EMERGENCY LIGHTING DENOTED WITH "E" SUFFIX OR SHOWN HALF SHADED TO BE CONNECTED TO EM3-16 VIA EMERGENCY TRANSFER DEVICE. STAIRWAY LIGHTING TO RUN 24/7 WITH INTEGRAL SENSOR TO REDUCE TO 50% WHEN UNOCCUPIED. LIGHTING TO BE CONNECTED AS FOLLOWS: STAIR 1: 2C-42/EM3-6 ALL EXIT LIGHTS ON GUEST FLOORS SHALL BE TYPE E3. Engi n ngir LLC8200 PEACHTREE AVE. ROCKFORD, MI 49341 P. 616-340-9627 SCALE: 1/8" = 1'-0" POWER & LIGHTING1 E204b ELEMENT FOURTH FLOOR SCALE: 1/4" = 1'-0" ENLARGED POWER PLANA E204b ELEMENT FOURTH FLOOR SCALE: 1/4" = 1'-0" ENLARGED ACCESSIBLE B E204b ELEMENT FOURTH FLOOR KING COMMON SUITE P:\2018\2018388 Aloft-Element Carmel\Working Drawings\E204b -Carmel DB.dwg, 5/26/2020 2:06:34 PM, cll09/28/20 DN UP DN UP 5C-1 - GENERAL CIRCUIT 5C-3 - BATHROOM CIRCUIT 5C-5 - MICROWAVE 5C-7/9 2P20A - VTAC CIRCUIT PG-401-1 PG-401-1 E E E E E E E E E E PG-401 PG-401 PG-401PG-401 PG-401PG-401 PG-401 PG-401 PG-401 ALR-09 ALR-09 ALR-09 ALR-09ALR-09ALR-09 ALR-09ALR-09 ALR-09 ALR-09 ALR-09 ALR-09 ALR-09 ALR-09 ALR-09 ALR-09 ALR-09 ALR-09 ALR-09 5A-59 5A-9- GENERAL CIRCUIT 5A-11 BATHROOM CIRCUIT 5A-13/15 2P20A - VTAC CKT 5A-1 - GENERAL CIRCUIT 5A-3 - BATHROOM CIRCUIT 5A-5/7 2P20A - VTAC CKT 5A-25- GENERAL CIRCUIT 5A-27 BATHROOM CIRCUIT 5A-29/31 2P20A - VTAC CKT 5A-17 - GENERAL CIRCUIT 5A-19 - BATHROOM CIRCUIT 5A-21/23 2P20A - VTAC CKT 5A-33 - GENERAL CIRCUIT 5A-35 - BATHROOM CIRCUIT 5A-37/39 2P20A - VTAC CKT IR A2 A2 5A-55 5A-59 5A-595A-59 5A-57 5A-57 5A-57 5A-57 TO LIGHTS ABOVE FS TS FW1 FW1 8 5A-2 - GENERAL CIRCUIT 5A-4 - BATHROOM CIRCUIT 5A-6/8 2P20A - VTAC CKT 5A-10 - GENERAL CIRCUIT 5A-12 - BATHROOM CIRCUIT 5A-14/16 2P20A - VTAC CKT 5A-18 - GENERAL CIRCUIT 5A-20 - BATHROOM CIRCUIT 5A-22/24 2P20A - VTAC CKT 5A-26 - GENERAL CIRCUIT 5A-28 - BATHROOM CIRCUIT 5A-30/32 2P20A - VTAC CKT 5A-34 - GENERAL CIRCUIT 5A-36 - BATHROOM CIRCUIT 5A-38/40 2P20A - VTAC CKT 5A-44- GENERAL CIRCUIT 5A-46 - BATHROOM CIRCUIT 5A-48/50 2P20A - VTAC CKT 5A-67- GENERAL CIRCUIT 5A-69 - BATHROOM CIRCUIT 5A-71 - BEDROOM CIRCUIT 5A-73/75 2P20A - VTAC CKT 5A-55 W A2 A2 A2 A2 A2 OS 5C-38 5C-38 5C-38 1 5C-38 J 3 F/SD 2 EM3-9 R-02R-02 W 5C-41 ALR-09 ALR-09 ALR-09 R-02 J4'EJ4 J4'E 5B-1 - GENERAL CIRCUIT 5B-3 - BATHROOM CIRCUIT 5B-5/7 2P20A - VTAC CKT 5B-2 - GENERAL CIRCUIT 5B-4 - BATHROOM CIRCUIT 5B-6/8 2P20A - VTAC CKT 5B-9- GENERAL CIRCUIT 5B-11 BATHROOM CIRCUIT 5B-13/15 2P20A - VTAC CKT 5B-17 - GENERAL CIRCUIT 5B-19 - BATHROOM CIRCUIT 5B-21/23 2P20A - VTAC CKT 5B-25- GENERAL CIRCUIT 5B-27 BATHROOM CIRCUIT 5B-29/31 2P20A - VTAC CKT 5B-10 - GENERAL CIRCUIT 5B-12 - BATHROOM CIRCUIT 5B-14/16 2P20A - VTAC CKT 5B-18 - GENERAL CIRCUIT 5B-20 - BATHROOM CIRCUIT 5B-22/24 2P20A - VTAC CKT 5B-26 - GENERAL CIRCUIT 5B-28 - BATHROOM CIRCUIT 5B-30/32 2P20A - VTAC CKT 5B-34 - GENERAL CIRCUIT 5B-36 - BATHROOM CIRCUIT 5B-38/40 2P20A - VTAC CKT 5B-33 - GENERAL CIRCUIT 5B-35 - BATHROOM CIRCUIT 5B-37/39 2P20A - VTAC CKT 5B-44- GENERAL CIRCUIT 5B-46 - BATHROOM CIRCUIT 5B-48/50 2P20A - VTAC CKT 5B-43- GENERAL CIRCUIT 5B-45 - BATHROOM CIRCUIT 5B-47/49 2P20A - VTAC CKT W ELEMENTALOFT A E205A 5A-57 P RE:?/E5.0 EF- ALR-09 EXTERIOR LED STRIP LIGHTING. REFER TO ARCH ELEVATIONS FOR EXACT LOCATION. EXTERIOR LED STRIP LIGHTING. REFER TO ARCH ELEVATIONS FOR EXACT LOCATION. XLR-30' XLR-34' F 5C-73/75 FC-13 DH DH T T T T T T T T TT T T T T T T T TT T T T T T T T X611 X611 ALR-09 ALR-09 A2 STUB (4) 4" C BETWEEN ALL FLOORS RE: 1/ET2.0 PROVIDE 4"X6" GROUND BAR, #8 AWG WIRE 5A-51 EM3-1 5A-51 112.5 KVAT-5A 5A-55 BP5B 3/4" FIRE RATED PLY WOOD. HORIZONTAL MOUNTED CENTER ON WALL. PAINT TO MATCH COLOR OF ROOM. LEAVE FIRE SYMBOL SHOWING. BP5A P 5A-63,65 RE:B2/E5.0 DS-1 P 5A-61 RE:C2/E5.0 EF-4 T T GENERAL POWER NOTES: 1. 2. 3. 4. 5. 6. 7. POWER KEY NOTES: 1 2 3 4 5 6 7 ALL 15A & 20A 120V NON-LOCKING RECEPTACLES WITHIN CHILDCARE AREAS (AGES 7 & UNDER) SHALL BE LISTED TAMPER RESISTANT PER NEC 406.12. THIS INCLUDES GUEST ROOMS. MOUNT PANELS, TRANSFORMERS, DISCONNECT SWITCHES, AND COMBINATION MOTOR STARTERS WITH ADEQUATE CLEARANCES IN ACCORDANCE WITH NEC 110. VOLTAGE DROP TO MEET ASHRAE 90.1 (2007) ELEMENT ROOMS WHERE PANEL IS INDICATED - LABEL PANELS IN EACH ROOM WITH FINAL ROOM NUMBERS, COORDINATE WITH ARCHITECT FOR FINAL ROOM NUMBERING. DENOTED ON PLAN AS BPG (FLOOR #)-XX. "XX" DENOTE ROOM NUMBER INSTALL FIRE ALARM PER MARRIOTT'S MODULE 14 STANDARDS INSTALL PER LATEST NEC CODE: 2008 NEC NOT ALL POWER KEY NOTES ARE USED ON EACH FLOOR E.C. SHALL WIRE INTAKE DOORS FOR LAUNDRY CHUTE PER CHUTE MANUFACTURER'S ELECTRICAL INTERLOCK WIRING DIAGRAM. INSTALL AND WIRE MANUAL ON/OFF SWITCH, PROVIDED WITH UNIT IN LAUNDRY ROOM . SMOKE DETECTOR TO BE WIRED TO DOOR INTERLOCK SO THAT INTERLOCKS WILL NOT OPERATE UPON ACTIVATION OF SMOKE DETECTOR, TYPICAL EACH FLOOR. PROVIDE 120V POWER TO INTAKE DOOR AND RUN 4 WIRES BETWEEN FLOORS TO EACH INTAKE DOOR. CONNECT ALL SMOKE DAMPERS TO 120V CIRCUIT AS SHOWN, COORDINATE VOLTAGE WITH SUPPLIER. CONNECT TO FIRE ALARM SYSTEM. VERIFY QUANTITY AND LOCATIONS WITH MECHANICAL PLANS. PROVIDE TWO-WAY COMMUNICATION SYSTEMS. REFER TO SPEC SECTION 283100 AT RECEPTION DESK AND CENTRAL CONTROL UNIT IN MPF ROOM. CONTROL EF WITH LIGHT SWITCH REFER TO FOOD SERVICE ELECTRICAL PLANS FOR EQUIPMENT REQUIREMENTS AND MOUNTING HEIGHTS. EC TO PROVIDE AND INSTALL CORD AND PLUG, NEMA 5-20R ELEV. CAB LIGHT DISC. (1) 1P20A CKT BREAKER MTD IN NEMA-1 ENCLOSURE W/HANDLE PADLOCK ATTACHMENT CAPABLE OF LOCKING BREAKER IN OPEN POSITION. PROVIDE NAMEPLATE ON DISC. INDICATING PANEL NAME. COORDINATE LOCATIONS OF ALL EQUIPMENT IN ELEVATOR EQUIPMENT ROOM/HOIST ROOM AND PIT WITH ELEVATOR SHOP DRAWINGS PRIOR TO ROUGH-IN. CONNECT EMERGENCY SHUT-DOWN OF ELEVATOR AS REQUIRED. SEQUENCE EQUIPMENT TO SHUT-DOWN THE ELEVATOR BY SMOKE DETECTORS WHEN REQUIRED. ELECTRICAL CONTRACTOR SHALL REFERENCE ELEVATOR SPECIFICATIONS AND COORDINATE ALL REQUIREMENTS WITH ELEVATOR MANUFACTURER FOR ALL ELECTRICAL REQUIREMENTS PRIOR TO ROUGH-IN. COORDINATE QUANTITY & LOCATION OF FIRE SUPPRESSION RISERS AND TAMPER SWITCHES WITH FIRE SUPPRESSION PLANS. VERIFY WITH STATE CODE TO PROVIDE SMOKE DETECTION FOR ELEVATOR, PROVIDE AND INSTALLED BY E.C. CONNECT TO FIRE ALARM SYSTEM UNLESS NOT ALLOWED BY STATE CODE. PROVIDE POWER AND CONTROL TO SIGNAGE, VERIFY EXACT LOCATION WITH ARCHITECTURAL ELEVATIONS AND FINAL CONNECTIONS WITH SIGNAGE SHOP DRAWINGS 8 9 GENERAL LIGHTING NOTES: 1. 2. 3. 4. 5. 6. EGRESS ILLUMINATION LEVELS MEET NFPA 101 OR LOCAL CODE LIGHTING DESIGN COMPLIES WITH 2010 INDIANA ENERGY CODE/ASHRAE 90.1 2007 VOLTAGE DROP TO MEET ASHRAE 90.1 (2007) CONNECT CORRIDOR, ELEVATOR LOBBY AND CORRIDOR FIXTURES TO EMERGENCY CIRCUIT AND NORMAL CIRCUIT, RUN 24/7, REFER TO LIGHTING CONTROL SCHEDULE OR PLANS FOR CIRCUITING CONNECT EMERGENCY LIGHTING TO UL LISTED 924 EMERGENCY TRANSFER DEVICE FOR ALL EMERGENCY LOADS. EMERGENCY LIGHTING MAY BE GROUPED TOGETHER ON ONE TRANSFER DEVICE SIZED FOR LOAD PER LIGHTING ZONES. CONNECT EXIT SIGNS TO EMERGENCY LIGHTING CIRCUIT FEEDING LIGHTING IN AREA AHEAD OF SWITCHING. LIGHTING KEYNOTES: PROVIDE POWER TO SIGNAGE REFER TO ARCH ELEVATIONS. COORDINATE WITH FINAL SIGNAGE PLANS. LOCAL SWITCHES TO OVERRIDE OCCUPANCY SENSOR OFF FOR AV USAGE. PROVIDE LOCAL DIMMER SWITCH AT PANEL TO SET LIGHTING LEVEL AT ONSET OF JOB. PROVIDE DIMMING EMERGENCY TRANSFER DEVICE FOR DIMMED CORRIDOR LOADS TO BRING EMERGENCY CORRIDOR LIGHTING TO 100% IN GENERATOR MODE. LIGHTS RUN 24/7. L2 L1 L3 10 REFER TO THIS SHEET FOR GUEST SUITE POWER AND LIGHTING CIRCUITS. ALOFT: CORRIDOR LOW LEVEL WALL LIGHTS ALR09 TO BE CONNECTED TO CIRCUIT 5A-58/EM3-18. LIGHTING TO RUN 24/7. DECORATIVE PENDANT LIGHTING PG-401 TO BE CONNECTED TO 5A-58. GENERAL BACK OF HOUSE LIGHTING TO BE CONNECTED TO 5A-60, EMERGENCY LIGHTING DENOTED WITH "E" SUFFIX OR SHOWN HALF SHADED TO BE CONNECTED TO EM3-18 VIA EMERGENCY TRANSFER DEVICE. STAIRWAY LIGHTING TO RUN 24/7 WITH INTEGRAL SENSOR TO REDUCE TO 50% WHEN UNOCCUPIED. LIGHTING TO BE CONNECTED AS FOLLOWS: STAIR 2: 2A-62/EM3-8 ALL EXIT LIGHTS ON GUEST SUITE FLOORS SHALL BE TYPE E3. Engi n ngir LLC8200 PEACHTREE AVE. ROCKFORD, MI 49341 P. 616-340-9627 SCALE: 1/8" = 1'-0" POWER & LIGHTING1 E205a ALOFT FIFTH FLOOR SCALE: 1/4" = 1'-0" ENLARGED POWER PLAN E205a ALOFT FIFTH FLOOR A P:\2018\2018388 Aloft-Element Carmel\Working Drawings\E205a -Carmel DB.dwg, 5/26/2020 2:09:38 PM, cll09/28/20 DN UP DN UP 5C-1 - GENERAL CIRCUIT 5C-3 - BATHROOM CIRCUIT 5C-5 - MICROWAVE 5C-7/9 2P20A - VTAC CIRCUIT 5C-11 - GENERAL CIRCUIT 5C-13 - BATHROOM CIRCUIT 5C-15 - MICROWAVE 5C-17/19 2P20A - VTAC CIRCUIT 5C-21 - GENERAL CIRCUIT 5C-23 - BATHROOM CIRCUIT 5C-25 - MICROWAVE 5C-27/29 2P20A - VTAC CIRCUIT BPG2 BPG2 BPG2 5C-2- GENERAL CIRCUIT 5C-4- BATHROOM CIRCUIT 5C-6 - MICROWAVE 5C-8/10 2P20A - VTAC CIRCUIT 5C-12 - GENERAL CIRCUIT 5C-14 - BATHROOM CIRCUIT 5C-16 - MICROWAVE 5C-18/20 2P20A - VTAC CIRCUIT BPG2 BPG2 5C-22 - GENERAL CIRCUIT 5C-24 - BATHROOM CIRCUIT 5C-26 - MICROWAVE 5C-28/30 2P20A - VTAC CIRCUIT BPG2 BPG2 BPG2 BPG2 BPG2 BPG3 PG-401-1 R-02 R-02 R-02 R-02 R-02R-02 R-02 R-02R-02 PG-402 PG-402 PG-402 PG-402 PG-402 PG-402 PG-401-1 PG-401-1 PG-401-1 PG-401-1 PG-401-1PG-401-1 PG-401-1 PG-401-1 PG-401-1 PG-401-1 PG-402 PG-402 5C-41 5C-41 E E E E E E E 5C-41 5C-41 5C-32 5C-32 5C-32 IR A2 A2 5C-40 5C-40 J4'E J4 J4'E TO LIGHTS ABOVE FS TS FW1 FW1 8 5C-32 W A2 A2 A2 OS 5C-38 W R-02R-02 ELEMENTALOFT A E205B PG-402 PG-402 PG-402 PG-402 PG-402 PG-402 PG-402 F/SD 2 EM3-11 B E205B R-02 5C-43 - GENERAL CIRCUIT 5C-45 - BATHROOM CIRCUIT 5C-47 - MICROWAVE 5C-49/51 2P20A - VTAC CIRCUIT 5C-44 - GENERAL CIRCUIT 5C-46 - BATHROOM CIRCUIT 5C-48 - MICROWAVE 5C-50/52 2P20A - VTAC CIRCUIT 5C-53 - GENERAL CIRCUIT 5C-55 - BATHROOM CIRCUIT 5C-57 - MICROWAVE 5C-59/61 2P20A - VTAC CIRCUIT 5C-63 - GENERAL CIRCUIT 5C-65 - BATHROOM CIRCUIT 5C-67 - MICROWAVE 5C-69/71 2P20A - VTAC CIRCUIT 5C-54 - GENERAL CIRCUIT 5C- 56 - BATHROOM CIRCUIT 5C-58 - MICROWAVE CIRCUIT 5C-60/62 2P20A - VTAC CKT G3-15 - GENERAL CIRCUIT G3-17 - BATHROOM CIRCUIT G3-19 - MICROWAVE G3-14/16 2P20A - VTAC CIRCUIT F 5C-73/75 FC-13 DH T T T T T T T TT T T T T T T T T T T T T T T R-02 PG-402 REFER TO SHEETE E612 FOR POWER AND LIGHTING CIRCUITS IN PANELS BP-G2 AND BP-G3. ALL OTHER GUEST SUITES WITHOUT A ROOM ELECTRICAL PANEL, CIRCUITS FOR POWER AND LIGHTING NOTED ON THIS PLAN. ELEMENT: CORRIDOR DOWNLIGHTS R-02 TO BE CONNECTED TO CIRCUIT 5C-34/EM3-20. LIGHTING TO RUN 24/7. REFER TO KEY NOTE L3 DECORATIVE PENDANT PG-401-1 TO BE CONNECTED TO 5C-34 & SCONCE LIGHTING PG-402 TO BE CONNECTED TO 5C-36 GENERAL BACK OF HOUSE LIGHTING TO BE CONNECTED TO 5C-42, EMERGENCY LIGHTING DENOTED WITH "E" SUFFIX OR SHOWN HALF SHADED TO BE CONNECTED TO EM3-20 VIA EMERGENCY TRANSFER DEVICE. STAIRWAY LIGHTING TO RUN 24/7 WITH INTEGRAL SENSOR TO REDUCE TO 50% WHEN UNOCCUPIED. LIGHTING TO BE CONNECTED AS FOLLOWS: STAIR 1: 2C-42/EM3-6 ALL EXIT LIGHTS ON GUEST FLOORS SHALL BE TYPE E3. 150 KVA 3/4" FIRE RATED PLY WOOD. HORIZONTAL MOUNTED CENTER ON WALL. PAINT TO MATCH COLOR OF ROOM. LEAVE FIRE SYMBOL SHOWING. STUB (4) 4" C BETWEEN ALL FLOORS RE: 1/ET2.0 PROVIDE 4"X6" GROUND BAR, #8 AWG WIRE 5C-31EM1-15 5C-32BP5C T-5B SDP5B 5C-40 P 5B-53,55 RE:B2/E5.0 DS-1 P 5B-51 RE:C2/E5.0 EF-4 T ALR-02 X400 X400 ALR-02 ALR-02 ALR-02 ALR-02 ALR-02 FRIG 3G-5 OVEN 2P40 3G-9/11 MICRO G3-13 HOOD G3-3 IRD IRD G3-8 DW J TV ALR-02 AC ACACAC AC G3-1 G3-1 G3-1 G3-1 G3-18 G3-18 4C-39 G3-16 G3-18 G3-18 G3-12 G3-8 VTAC G3-4/6 2P20 G3-10 G3-10 T TV60" 60" T POKE THRU POKE THRU GENERAL POWER NOTES: 1. 2. 3. 4. 5. 6. 7. POWER KEY NOTES: 1 2 3 4 5 6 7 ALL 15A & 20A 120V NON-LOCKING RECEPTACLES WITHIN CHILDCARE AREAS (AGES 7 & UNDER) SHALL BE LISTED TAMPER RESISTANT PER NEC 406.12. THIS INCLUDES GUEST ROOMS. MOUNT PANELS, TRANSFORMERS, DISCONNECT SWITCHES, AND COMBINATION MOTOR STARTERS WITH ADEQUATE CLEARANCES IN ACCORDANCE WITH NEC 110. VOLTAGE DROP TO MEET ASHRAE 90.1 (2007) ELEMENT ROOMS WHERE PANEL IS INDICATED - LABEL PANELS IN EACH ROOM WITH FINAL ROOM NUMBERS, COORDINATE WITH ARCHITECT FOR FINAL ROOM NUMBERING. DENOTED ON PLAN AS BPG (FLOOR #)-XX. "XX" DENOTE ROOM NUMBER INSTALL FIRE ALARM PER MARRIOTT'S MODULE 14 STANDARDS INSTALL PER LATEST NEC CODE: 2008 NEC NOT ALL POWER KEY NOTES ARE USED ON EACH FLOOR E.C. SHALL WIRE INTAKE DOORS FOR LAUNDRY CHUTE PER CHUTE MANUFACTURER'S ELECTRICAL INTERLOCK WIRING DIAGRAM. INSTALL AND WIRE MANUAL ON/OFF SWITCH, PROVIDED WITH UNIT IN LAUNDRY ROOM . SMOKE DETECTOR TO BE WIRED TO DOOR INTERLOCK SO THAT INTERLOCKS WILL NOT OPERATE UPON ACTIVATION OF SMOKE DETECTOR, TYPICAL EACH FLOOR. PROVIDE 120V POWER TO INTAKE DOOR AND RUN 4 WIRES BETWEEN FLOORS TO EACH INTAKE DOOR. CONNECT ALL SMOKE DAMPERS TO 120V CIRCUIT AS SHOWN, COORDINATE VOLTAGE WITH SUPPLIER. CONNECT TO FIRE ALARM SYSTEM. VERIFY QUANTITY AND LOCATIONS WITH MECHANICAL PLANS. PROVIDE TWO-WAY COMMUNICATION SYSTEMS. REFER TO SPEC SECTION 283100 AT RECEPTION DESK AND CENTRAL CONTROL UNIT IN MPF ROOM. CONTROL EF WITH LIGHT SWITCH REFER TO FOOD SERVICE ELECTRICAL PLANS FOR EQUIPMENT REQUIREMENTS AND MOUNTING HEIGHTS. EC TO PROVIDE AND INSTALL CORD AND PLUG, NEMA 5-20R ELEV. CAB LIGHT DISC. (1) 1P20A CKT BREAKER MTD IN NEMA-1 ENCLOSURE W/HANDLE PADLOCK ATTACHMENT CAPABLE OF LOCKING BREAKER IN OPEN POSITION. PROVIDE NAMEPLATE ON DISC. INDICATING PANEL NAME. COORDINATE LOCATIONS OF ALL EQUIPMENT IN ELEVATOR EQUIPMENT ROOM/HOIST ROOM AND PIT WITH ELEVATOR SHOP DRAWINGS PRIOR TO ROUGH-IN. CONNECT EMERGENCY SHUT-DOWN OF ELEVATOR AS REQUIRED. SEQUENCE EQUIPMENT TO SHUT-DOWN THE ELEVATOR BY SMOKE DETECTORS WHEN REQUIRED. ELECTRICAL CONTRACTOR SHALL REFERENCE ELEVATOR SPECIFICATIONS AND COORDINATE ALL REQUIREMENTS WITH ELEVATOR MANUFACTURER FOR ALL ELECTRICAL REQUIREMENTS PRIOR TO ROUGH-IN. COORDINATE QUANTITY & LOCATION OF FIRE SUPPRESSION RISERS AND TAMPER SWITCHES WITH FIRE SUPPRESSION PLANS. VERIFY WITH STATE CODE TO PROVIDE SMOKE DETECTION FOR ELEVATOR, PROVIDE AND INSTALLED BY E.C. CONNECT TO FIRE ALARM SYSTEM UNLESS NOT ALLOWED BY STATE CODE. PROVIDE POWER AND CONTROL TO SIGNAGE, VERIFY EXACT LOCATION WITH ARCHITECTURAL ELEVATIONS AND FINAL CONNECTIONS WITH SIGNAGE SHOP DRAWINGS 8 9 GENERAL LIGHTING NOTES: 1. 2. 3. 4. 5. 6. EGRESS ILLUMINATION LEVELS MEET NFPA 101 OR LOCAL CODE LIGHTING DESIGN COMPLIES WITH 2010 INDIANA ENERGY CODE/ASHRAE 90.1 2007 VOLTAGE DROP TO MEET ASHRAE 90.1 (2007) CONNECT CORRIDOR, ELEVATOR LOBBY AND CORRIDOR FIXTURES TO EMERGENCY CIRCUIT AND NORMAL CIRCUIT, RUN 24/7, REFER TO LIGHTING CONTROL SCHEDULE OR PLANS FOR CIRCUITING CONNECT EMERGENCY LIGHTING TO UL LISTED 924 EMERGENCY TRANSFER DEVICE FOR ALL EMERGENCY LOADS. EMERGENCY LIGHTING MAY BE GROUPED TOGETHER ON ONE TRANSFER DEVICE SIZED FOR LOAD PER LIGHTING ZONES. CONNECT EXIT SIGNS TO EMERGENCY LIGHTING CIRCUIT FEEDING LIGHTING IN AREA AHEAD OF SWITCHING. LIGHTING KEYNOTES: PROVIDE POWER TO SIGNAGE REFER TO ARCH ELEVATIONS. COORDINATE WITH FINAL SIGNAGE PLANS. LOCAL SWITCHES TO OVERRIDE OCCUPANCY SENSOR OFF FOR AV USAGE. PROVIDE LOCAL DIMMER SWITCH AT PANEL TO SET LIGHTING LEVEL AT ONSET OF JOB. PROVIDE DIMMING EMERGENCY TRANSFER DEVICE FOR DIMMED CORRIDOR LOADS TO BRING EMERGENCY CORRIDOR LIGHTING TO 100% IN GENERATOR MODE. LIGHTS RUN 24/7. L2 L1 L3 10 Engi n ngir LLC8200 PEACHTREE AVE. ROCKFORD, MI 49341 P. 616-340-9627 SCALE: 1/8" = 1'-0" POWER & LIGHTING1 E205b ELEMENT FIFTH FLOOR SCALE: 1/4" = 1'-0" ENLARGED POWER PLANA E205b ELEMENT FIFTH FLOOR SCALE: 1/4" = 1'-0" ENLARGED ACCESSIBLE B E205b ELEMENT FIFTH FLOOR KING COMMON SUITE P:\2018\2018388 Aloft-Element Carmel\Working Drawings\E205b -Carmel DB.dwg, 5/26/2020 2:11:09 PM, cll09/28/20 DNDN 6C-1 - GENERAL CIRCUIT 6C-3 - BATHROOM CIRCUIT 6C-5 - MICROWAVE 6C-7/9 2P20A - VTAC CIRCUIT PG-401-1 PG-401-1 E E E E E E E E E E PG-401 PG-401 PG-401PG-401PG-401PG-401 PG-401 PG-401 PG-401 ALR-09 ALR-09 ALR-09 ALR-09ALR-09ALR-09 ALR-09ALR-09 ALR-09 ALR-09 ALR-09 ALR-09 ALR-09 ALR-09 ALR-09 ALR-09 ALR-09 ALR-09 ALR-09 6A-59 6A-9- GENERAL CIRCUIT 6A-11 BATHROOM CIRCUIT 6A-13/15 2P20A - VTAC CKT 6A-1 - GENERAL CIRCUIT 6A-3 - BATHROOM CIRCUIT 6A-5/7 2P20A - VTAC CKT 6A-25- GENERAL CIRCUIT 6A-27 BATHROOM CIRCUIT 6A-29/31 2P20A - VTAC CKT 6A-17 - GENERAL CIRCUIT 6A-19 - BATHROOM CIRCUIT 6A-21/23 2P20A - VTAC CKT 6A-33 - GENERAL CIRCUIT 6A-35 - BATHROOM CIRCUIT 6A-37/39 2P20A - VTAC CKT IR A2 6A-55 6A-59 6A-596A-59 6A-57 6A-57 6A-57 6A-57 TO LIGHTS ABOVE FS TS FW1 FW1 8 6A-2 - GENERAL CIRCUIT 6A-4 - BATHROOM CIRCUIT 6A-6/8 2P20A - VTAC CKT 6A-10 - GENERAL CIRCUIT 6A-12 - BATHROOM CIRCUIT 6A-14/16 2P20A - VTAC CKT 6A-18 - GENERAL CIRCUIT 6A-20 - BATHROOM CIRCUIT 6A-22/24 2P20A - VTAC CKT 6A-26 - GENERAL CIRCUIT 6A-28 - BATHROOM CIRCUIT 6A-30/32 2P20A - VTAC CKT 6A-34 - GENERAL CIRCUIT 6A-36 - BATHROOM CIRCUIT 6A-38/40 2P20A - VTAC CKT 6A-44- GENERAL CIRCUIT 6A-46 - BATHROOM CIRCUIT 6A-48/50 2P20A - VTAC CKT 6A-62- GENERAL CIRCUIT 6A-64 - BATHROOM CIRCUIT 6A-66 - BEDROOM CIRCUIT 6A-68/70 2P20A - VTAC CKT 6A-61 W A2 A2 A2 A2 A2 OS 6C-38 6C-38 6C-38 1 6C-38 J 3 F/SD 2 EM3-9 R-02R-02 W 6C-41 ALR-09 ALR-09 ALR-09 R-02 J4'EJ4 J4'E 6B-1 - GENERAL CIRCUIT 6B-3 - BATHROOM CIRCUIT 6B-5/7 2P20A - VTAC CKT 6B-2 - GENERAL CIRCUIT 6B-4 - BATHROOM CIRCUIT 6B-6/8 2P20A - VTAC CKT 6B-9- GENERAL CIRCUIT 6B-11 BATHROOM CIRCUIT 6B-13/15 2P20A - VTAC CKT 6B-17 - GENERAL CIRCUIT 6B-19 - BATHROOM CIRCUIT 6B-21/23 2P20A - VTAC CKT 6B-25- GENERAL CIRCUIT 6B-27 BATHROOM CIRCUIT 6B-29/31 2P20A - VTAC CKT 6B-10 - GENERAL CIRCUIT 6B-12 - BATHROOM CIRCUIT 6B-14/16 2P20A - VTAC CKT 6B-18 - GENERAL CIRCUIT 6B-20 - BATHROOM CIRCUIT 6B-22/24 2P20A - VTAC CKT 6B-26 - GENERAL CIRCUIT 6B-28 - BATHROOM CIRCUIT 6B-30/32 2P20A - VTAC CKT 6B-34 - GENERAL CIRCUIT 6B-36 - BATHROOM CIRCUIT 6B-38/40 2P20A - VTAC CKT 6B-33 - GENERAL CIRCUIT 6B-35 - BATHROOM CIRCUIT 6B-37/39 2P20A - VTAC CKT 6B-44- GENERAL CIRCUIT 6B-46 - BATHROOM CIRCUIT 6B-48/50 2P20A - VTAC CKT 6B-43- GENERAL CIRCUIT 6B-45 - BATHROOM CIRCUIT 6B-47/49 2P20A - VTAC CKT W ELEMENTALOFT A E206A 6A-57 P 6A-63 P RE:?/E5.0 EF- ALR-09 IRCR CR CR CR CR CR CR CR CR CR CR CR CR CR CR EXTERIOR LED STRIP LIGHTING. REFER TO ARCH ELEVATIONS FOR EXACT LOCATION. EXTERIOR LED STRIP LIGHTING. REFER TO ARCH ELEVATIONS FOR EXACT LOCATION. XLR-16' XLR-24' F 6C-37/39 FC-14 DH DH R-02 EF-9 T T T T T T T T TT T T T T T T T TT T T T T T T T X612 X612 ALR-09 ALR-09 A2 112.5 KVA STUB (4) 4" C BETWEEN ALL FLOORS RE: 1/ET2.0 PROVIDE 4"X6" GROUND BAR, #8 AWG WIRE 6A-51 EM3-1 6A-51 BP6A T-6A 6A-55 BP6B 3/4" FIRE RATED PLY WOOD. HORIZONTAL MOUNTED CENTER ON WALL. PAINT TO MATCH COLOR OF ROOM. LEAVE FIRE SYMBOL SHOWING.P 6A-65,67 RE:B2/E5.0 DS-1 P 6A-63 RE:C2/E5.0 EF-4 T EF-9 T GENERAL POWER NOTES: 1. 2. 3. 4. 5. 6. 7. POWER KEY NOTES: 1 2 3 4 5 6 7 ALL 15A & 20A 120V NON-LOCKING RECEPTACLES WITHIN CHILDCARE AREAS (AGES 7 & UNDER) SHALL BE LISTED TAMPER RESISTANT PER NEC 406.12. THIS INCLUDES GUEST ROOMS. MOUNT PANELS, TRANSFORMERS, DISCONNECT SWITCHES, AND COMBINATION MOTOR STARTERS WITH ADEQUATE CLEARANCES IN ACCORDANCE WITH NEC 110. VOLTAGE DROP TO MEET ASHRAE 90.1 (2007) ELEMENT ROOMS WHERE PANEL IS INDICATED - LABEL PANELS IN EACH ROOM WITH FINAL ROOM NUMBERS, COORDINATE WITH ARCHITECT FOR FINAL ROOM NUMBERING. DENOTED ON PLAN AS BPG (FLOOR #)-XX. "XX" DENOTE ROOM NUMBER INSTALL FIRE ALARM PER MARRIOTT'S MODULE 14 STANDARDS INSTALL PER LATEST NEC CODE: 2008 NEC NOT ALL POWER KEY NOTES ARE USED ON EACH FLOOR E.C. SHALL WIRE INTAKE DOORS FOR LAUNDRY CHUTE PER CHUTE MANUFACTURER'S ELECTRICAL INTERLOCK WIRING DIAGRAM. INSTALL AND WIRE MANUAL ON/OFF SWITCH, PROVIDED WITH UNIT IN LAUNDRY ROOM . SMOKE DETECTOR TO BE WIRED TO DOOR INTERLOCK SO THAT INTERLOCKS WILL NOT OPERATE UPON ACTIVATION OF SMOKE DETECTOR, TYPICAL EACH FLOOR. PROVIDE 120V POWER TO INTAKE DOOR AND RUN 4 WIRES BETWEEN FLOORS TO EACH INTAKE DOOR. CONNECT ALL SMOKE DAMPERS TO 120V CIRCUIT AS SHOWN, COORDINATE VOLTAGE WITH SUPPLIER. CONNECT TO FIRE ALARM SYSTEM. VERIFY QUANTITY AND LOCATIONS WITH MECHANICAL PLANS. PROVIDE TWO-WAY COMMUNICATION SYSTEMS. REFER TO SPEC SECTION 283100 AT RECEPTION DESK AND CENTRAL CONTROL UNIT IN MPF ROOM. CONTROL EF WITH LIGHT SWITCH REFER TO FOOD SERVICE ELECTRICAL PLANS FOR EQUIPMENT REQUIREMENTS AND MOUNTING HEIGHTS. EC TO PROVIDE AND INSTALL CORD AND PLUG, NEMA 5-20R ELEV. CAB LIGHT DISC. (1) 1P20A CKT BREAKER MTD IN NEMA-1 ENCLOSURE W/HANDLE PADLOCK ATTACHMENT CAPABLE OF LOCKING BREAKER IN OPEN POSITION. PROVIDE NAMEPLATE ON DISC. INDICATING PANEL NAME. COORDINATE LOCATIONS OF ALL EQUIPMENT IN ELEVATOR EQUIPMENT ROOM/HOIST ROOM AND PIT WITH ELEVATOR SHOP DRAWINGS PRIOR TO ROUGH-IN. CONNECT EMERGENCY SHUT-DOWN OF ELEVATOR AS REQUIRED. SEQUENCE EQUIPMENT TO SHUT-DOWN THE ELEVATOR BY SMOKE DETECTORS WHEN REQUIRED. ELECTRICAL CONTRACTOR SHALL REFERENCE ELEVATOR SPECIFICATIONS AND COORDINATE ALL REQUIREMENTS WITH ELEVATOR MANUFACTURER FOR ALL ELECTRICAL REQUIREMENTS PRIOR TO ROUGH-IN. COORDINATE QUANTITY & LOCATION OF FIRE SUPPRESSION RISERS AND TAMPER SWITCHES WITH FIRE SUPPRESSION PLANS. VERIFY WITH STATE CODE TO PROVIDE SMOKE DETECTION FOR ELEVATOR, PROVIDE AND INSTALLED BY E.C. CONNECT TO FIRE ALARM SYSTEM UNLESS NOT ALLOWED BY STATE CODE. PROVIDE POWER AND CONTROL TO SIGNAGE, VERIFY EXACT LOCATION WITH ARCHITECTURAL ELEVATIONS AND FINAL CONNECTIONS WITH SIGNAGE SHOP DRAWINGS 8 9 GENERAL LIGHTING NOTES: 1. 2. 3. 4. 5. 6. EGRESS ILLUMINATION LEVELS MEET NFPA 101 OR LOCAL CODE LIGHTING DESIGN COMPLIES WITH 2010 INDIANA ENERGY CODE/ASHRAE 90.1 2007 VOLTAGE DROP TO MEET ASHRAE 90.1 (2007) CONNECT CORRIDOR, ELEVATOR LOBBY AND CORRIDOR FIXTURES TO EMERGENCY CIRCUIT AND NORMAL CIRCUIT, RUN 24/7, REFER TO LIGHTING CONTROL SCHEDULE OR PLANS FOR CIRCUITING CONNECT EMERGENCY LIGHTING TO UL LISTED 924 EMERGENCY TRANSFER DEVICE FOR ALL EMERGENCY LOADS. EMERGENCY LIGHTING MAY BE GROUPED TOGETHER ON ONE TRANSFER DEVICE SIZED FOR LOAD PER LIGHTING ZONES. CONNECT EXIT SIGNS TO EMERGENCY LIGHTING CIRCUIT FEEDING LIGHTING IN AREA AHEAD OF SWITCHING. LIGHTING KEYNOTES: PROVIDE POWER TO SIGNAGE REFER TO ARCH ELEVATIONS. COORDINATE WITH FINAL SIGNAGE PLANS. LOCAL SWITCHES TO OVERRIDE OCCUPANCY SENSOR OFF FOR AV USAGE. PROVIDE LOCAL DIMMER SWITCH AT PANEL TO SET LIGHTING LEVEL AT ONSET OF JOB. PROVIDE DIMMING EMERGENCY TRANSFER DEVICE FOR DIMMED CORRIDOR LOADS TO BRING EMERGENCY CORRIDOR LIGHTING TO 100% IN GENERATOR MODE. LIGHTS RUN 24/7. L2 L1 L3 10 REFER TO THIS SHEET FOR GUEST SUITE POWER AND LIGHTING CIRCUITS. ALOFT: CORRIDOR LOW LEVEL WALL LIGHTS ALR09 TO BE CONNECTED TO CIRCUIT 6A-58/EM3-22. LIGHTING TO RUN 24/7. DECORATIVE PENDANT LIGHTING PG-401 TO BE CONNECTED TO 6A-58. GENERAL BACK OF HOUSE LIGHTING TO BE CONNECTED TO 6A-60, EMERGENCY LIGHTING DENOTED WITH "E" SUFFIX OR SHOWN HALF SHADED TO BE CONNECTED TO EM3-22 VIA EMERGENCY TRANSFER DEVICE. STAIRWAY LIGHTING TO RUN 24/7 WITH INTEGRAL SENSOR TO REDUCE TO 50% WHEN UNOCCUPIED. LIGHTING TO BE CONNECTED AS FOLLOWS: STAIR 2: 2A-62/EM3-8 ALL EXIT LIGHTS ON GUEST SUITE FLOORS SHALL BE TYPE E3. Engi n ngir LLC8200 PEACHTREE AVE. ROCKFORD, MI 49341 P. 616-340-9627 SCALE: 1/8" = 1'-0" POWER & LIGHTING1 E206a ALOFT SIXTH FLOOR SCALE: 1/4" = 1'-0" ENLARGED POWER PLANA E206a ALOFT SIXTH FLOOR P:\2018\2018388 Aloft-Element Carmel\Working Drawings\E206a -Carmel DB.dwg, 5/26/2020 2:12:42 PM, cll09/28/20 DNDN 6C-1 - GENERAL CIRCUIT 6C-3 - BATHROOM CIRCUIT 6C-5 - MICROWAVE 6C-7/9 2P20A - VTAC CIRCUIT 6C-11 - GENERAL CIRCUIT 6C-13 - BATHROOM CIRCUIT 6C-15 - MICROWAVE 6C-17/19 2P20A - VTAC CIRCUIT 6C-21 - GENERAL CIRCUIT 6C-23 - BATHROOM CIRCUIT 6C-25 - MICROWAVE 6C-27/29 2P20A - VTAC CIRCUIT BPG2 BPG2 BPG2 6C-2- GENERAL CIRCUIT 6C-4- BATHROOM CIRCUIT 6C-6 - MICROWAVE 6C-8/10 2P20A - VTAC CIRCUIT 6C-12 - GENERAL CIRCUIT 6C-14 - BATHROOM CIRCUIT 6C-16 - MICROWAVE 6C-18/20 2P20A - VTAC CIRCUIT BPG2 BPG2 6C-22 - GENERAL CIRCUIT 6C-24 - BATHROOM CIRCUIT 6C-26 - MICROWAVE 6C-28/30 2P20A - VTAC CIRCUIT BPG2 BPG2 BPG2 BPG3 BPG2 BPG2 PG-402 PG-401-1 R-02 R-02 R-02 R-02 R-02 R-02R-02 R-02R-02 R-02R-02 PG-402 PG-402 PG-402 PG-402 PG-402 PG-401-1 PG-401-1 PG-401-1 PG-401-1 PG-401-1PG-401-1 PG-401-1 PG-401-1PG-401-1 PG-401-1 6C-41 6C-41 E E E E E E E 6C-41 6C-41 6C-32 6C-32 6C-32 6C-32 IR A2 A2 6C-40 6C-40 J4'E J4 J4'E TO LIGHTS ABOVE FS TS FW1 FW1 8 6C-32 W A2 A2 A2 OS 6C-38 W R-02R-02 ELEMENTALOFT A E206B PG-402 PG-402PG-402 PG-402 PG-402 F/SD 2 EM3-11 B E206B CR CR CR CR CR CR 6C-43 - GENERAL CIRCUIT 6C-45 - BATHROOM CIRCUIT 6C-47 - MICROWAVE 6C-49/51 2P20A - VTAC CIRCUIT 6C-44 - GENERAL CIRCUIT 6C-46 - BATHROOM CIRCUIT 6C-48 - MICROWAVE 6C-50/52 2P20A - VTAC CIRCUIT 6C-54 - GENERAL CIRCUIT 6C-56 - BATHROOM CIRCUIT 6C-58 - MICROWAVE 6C-60/62 2P20A - VTAC CIRCUIT 6C-64 - GENERAL CIRCUIT 6C-66 - BATHROOM CIRCUIT 6C-68 - MICROWAVE 6C-70/72 2P20A - VTAC CIRCUIT 6C-53- GENERAL CIRCUIT 6C-55 BATHROOM CIRCUIT 6C-57 - MICROWAVE CIRCUIT 6C-59/61 2P20A - VTAC CKT G3-15 - GENERAL CIRCUIT G3-17 - BATHROOM CIRCUIT G3-19 - MICROWAVE G3-14/16 2P20A - VTAC CIRCUIT F 6C-37/39 FC-14 DH T T T T T T T TT T T T T T T T T T T T TT T PG-402 PG-402 PG-402 R-023/4" FIRE RATED PLY WOOD. HORIZONTAL MOUNTED CENTER ON WALL. PAINT TO MATCH COLOR OF ROOM. LEAVE FIRE SYMBOL SHOWING. STUB (4) 4" C BETWEEN ALL FLOORS RE: 1/ET2.0 PROVIDE 4"X6" GROUND BAR, #8 AWG WIRE 6C-31EM1-17 6C-32 T-6B SDP6B 6C-40 BP6C 6B-53,55 RE:B2/E5.0 DS-1 6B-51 RE:C2/E5.0 EF-4 225 KVA T ALR-02 X400 X400 ALR-02 ALR-02 ALR-02 ALR-02 ALR-02 FRIG 3G-5 OVEN 2P40 3G-9/11 MICRO G3-13 HOOD G3-3 IRD IRD G3-8 DW J TV ALR-02 AC ACACAC AC G3-1 G3-1 G3-1 G3-1 G3-18 G3-18 4C-39 G3-16 G3-18 G3-18 G3-12 G3-8 VTAC G3-4/6 2P20 G3-10 G3-10 T TV60" 60" T POKE THRU POKE THRU GENERAL POWER NOTES: 1. 2. 3. 4. 5. 6. 7. POWER KEY NOTES: 1 2 3 4 5 6 7 ALL 15A & 20A 120V NON-LOCKING RECEPTACLES WITHIN CHILDCARE AREAS (AGES 7 & UNDER) SHALL BE LISTED TAMPER RESISTANT PER NEC 406.12. THIS INCLUDES GUEST ROOMS. MOUNT PANELS, TRANSFORMERS, DISCONNECT SWITCHES, AND COMBINATION MOTOR STARTERS WITH ADEQUATE CLEARANCES IN ACCORDANCE WITH NEC 110. VOLTAGE DROP TO MEET ASHRAE 90.1 (2007) ELEMENT ROOMS WHERE PANEL IS INDICATED - LABEL PANELS IN EACH ROOM WITH FINAL ROOM NUMBERS, COORDINATE WITH ARCHITECT FOR FINAL ROOM NUMBERING. DENOTED ON PLAN AS BPG (FLOOR #)-XX. "XX" DENOTE ROOM NUMBER INSTALL FIRE ALARM PER MARRIOTT'S MODULE 14 STANDARDS INSTALL PER LATEST NEC CODE: 2008 NEC NOT ALL POWER KEY NOTES ARE USED ON EACH FLOOR E.C. SHALL WIRE INTAKE DOORS FOR LAUNDRY CHUTE PER CHUTE MANUFACTURER'S ELECTRICAL INTERLOCK WIRING DIAGRAM. INSTALL AND WIRE MANUAL ON/OFF SWITCH, PROVIDED WITH UNIT IN LAUNDRY ROOM . SMOKE DETECTOR TO BE WIRED TO DOOR INTERLOCK SO THAT INTERLOCKS WILL NOT OPERATE UPON ACTIVATION OF SMOKE DETECTOR, TYPICAL EACH FLOOR. PROVIDE 120V POWER TO INTAKE DOOR AND RUN 4 WIRES BETWEEN FLOORS TO EACH INTAKE DOOR. CONNECT ALL SMOKE DAMPERS TO 120V CIRCUIT AS SHOWN, COORDINATE VOLTAGE WITH SUPPLIER. CONNECT TO FIRE ALARM SYSTEM. VERIFY QUANTITY AND LOCATIONS WITH MECHANICAL PLANS. PROVIDE TWO-WAY COMMUNICATION SYSTEMS. REFER TO SPEC SECTION 283100 AT RECEPTION DESK AND CENTRAL CONTROL UNIT IN MPF ROOM. CONTROL EF WITH LIGHT SWITCH REFER TO FOOD SERVICE ELECTRICAL PLANS FOR EQUIPMENT REQUIREMENTS AND MOUNTING HEIGHTS. EC TO PROVIDE AND INSTALL CORD AND PLUG, NEMA 5-20R ELEV. CAB LIGHT DISC. (1) 1P20A CKT BREAKER MTD IN NEMA-1 ENCLOSURE W/HANDLE PADLOCK ATTACHMENT CAPABLE OF LOCKING BREAKER IN OPEN POSITION. PROVIDE NAMEPLATE ON DISC. INDICATING PANEL NAME. COORDINATE LOCATIONS OF ALL EQUIPMENT IN ELEVATOR EQUIPMENT ROOM/HOIST ROOM AND PIT WITH ELEVATOR SHOP DRAWINGS PRIOR TO ROUGH-IN. CONNECT EMERGENCY SHUT-DOWN OF ELEVATOR AS REQUIRED. SEQUENCE EQUIPMENT TO SHUT-DOWN THE ELEVATOR BY SMOKE DETECTORS WHEN REQUIRED. ELECTRICAL CONTRACTOR SHALL REFERENCE ELEVATOR SPECIFICATIONS AND COORDINATE ALL REQUIREMENTS WITH ELEVATOR MANUFACTURER FOR ALL ELECTRICAL REQUIREMENTS PRIOR TO ROUGH-IN. COORDINATE QUANTITY & LOCATION OF FIRE SUPPRESSION RISERS AND TAMPER SWITCHES WITH FIRE SUPPRESSION PLANS. VERIFY WITH STATE CODE TO PROVIDE SMOKE DETECTION FOR ELEVATOR, PROVIDE AND INSTALLED BY E.C. CONNECT TO FIRE ALARM SYSTEM UNLESS NOT ALLOWED BY STATE CODE. PROVIDE POWER AND CONTROL TO SIGNAGE, VERIFY EXACT LOCATION WITH ARCHITECTURAL ELEVATIONS AND FINAL CONNECTIONS WITH SIGNAGE SHOP DRAWINGS 8 9 GENERAL LIGHTING NOTES: 1. 2. 3. 4. 5. 6. EGRESS ILLUMINATION LEVELS MEET NFPA 101 OR LOCAL CODE LIGHTING DESIGN COMPLIES WITH 2010 INDIANA ENERGY CODE/ASHRAE 90.1 2007 VOLTAGE DROP TO MEET ASHRAE 90.1 (2007) CONNECT CORRIDOR, ELEVATOR LOBBY AND CORRIDOR FIXTURES TO EMERGENCY CIRCUIT AND NORMAL CIRCUIT, RUN 24/7, REFER TO LIGHTING CONTROL SCHEDULE OR PLANS FOR CIRCUITING CONNECT EMERGENCY LIGHTING TO UL LISTED 924 EMERGENCY TRANSFER DEVICE FOR ALL EMERGENCY LOADS. EMERGENCY LIGHTING MAY BE GROUPED TOGETHER ON ONE TRANSFER DEVICE SIZED FOR LOAD PER LIGHTING ZONES. CONNECT EXIT SIGNS TO EMERGENCY LIGHTING CIRCUIT FEEDING LIGHTING IN AREA AHEAD OF SWITCHING. LIGHTING KEYNOTES: PROVIDE POWER TO SIGNAGE REFER TO ARCH ELEVATIONS. COORDINATE WITH FINAL SIGNAGE PLANS. LOCAL SWITCHES TO OVERRIDE OCCUPANCY SENSOR OFF FOR AV USAGE. PROVIDE LOCAL DIMMER SWITCH AT PANEL TO SET LIGHTING LEVEL AT ONSET OF JOB. PROVIDE DIMMING EMERGENCY TRANSFER DEVICE FOR DIMMED CORRIDOR LOADS TO BRING EMERGENCY CORRIDOR LIGHTING TO 100% IN GENERATOR MODE. LIGHTS RUN 24/7. L2 L1 L3 10 REFER TO SHEETE E612 FOR POWER AND LIGHTING CIRCUITS IN PANELS BP-G2 AND BP-G3. ALL OTHER GUEST SUITES WITHOUT A ROOM ELECTRICAL PANEL, CIRCUITS FOR POWER AND LIGHTING NOTED ON THIS PLAN. ELEMENT: CORRIDOR DOWNLIGHTS R-02 TO BE CONNECTED TO CIRCUIT 6C-34/EM3-24. LIGHTING TO RUN 24/7. REFER TO KEY NOTE L3 DECORATIVE PENDANT PG-401-1 TO BE CONNECTED TO 6C-34 & SCONCE LIGHTING PG-402 TO BE CONNECTED TO 6C-36 GENERAL BACK OF HOUSE LIGHTING TO BE CONNECTED TO 6C-42, EMERGENCY LIGHTING DENOTED WITH "E" SUFFIX OR SHOWN HALF SHADED TO BE CONNECTED TO EM3-24 VIA EMERGENCY TRANSFER DEVICE. STAIRWAY LIGHTING TO RUN 24/7 WITH INTEGRAL SENSOR TO REDUCE TO 50% WHEN UNOCCUPIED. LIGHTING TO BE CONNECTED AS FOLLOWS: STAIR 1: 2C-42/EM3-6 ALL EXIT LIGHTS ON GUEST FLOORS SHALL BE TYPE E3. Engi n ngir LLC8200 PEACHTREE AVE. ROCKFORD, MI 49341 P. 616-340-9627 SCALE: 1/8" = 1'-0" POWER & LIGHTING1 E206b ELEMENT SIXTH FLOOR SCALE: 1/4" = 1'-0" ENLARGED POWER PLANA E206b ELEMENT SIXTH FLOOR SCALE: 1/4" = 1'-0" ENLARGED ACCESSIBLE B E206b ELEMENT SIXTH FLOOR KING COMMON SUITE P:\2018\2018388 Aloft-Element Carmel\Working Drawings\E206b -Carmel DB.dwg, 5/26/2020 2:14:46 PM, cll09/28/20 TV VTAC-2 DH-1 DH-2 DH-3 ALR-02 DH-1 EF-1 ALR-11 EL-001 X-400 J X-300 DH-5 ALR-03 DB E5 TE3 E1 E1 DLE8 DLE8 DH-5 E6 DH-6 J X-302 B B- DENOTES BLACK DEVICES HUSB B TV VTAC-1 DH-3 T E3 ALR-02 E1 E1 DB E5 E6 DL E8 DLE8 EL-001 J X-300 DH-5 DH-1 DH-2 DH-5 EF-1 ALR-11 X-400 ALR-03 DH-5 DH-6 J X-301 H USB J X-301 H USB DH-5 TV VTAC-2 DH-1 DH-2 DH-3 ALR-02 DH-5 EF-1 ALR-11J X-302 B DH-5 EL-001 X-400 J X-300 DH-5 ALR-03 B- DENOTES BLACK DEVICES TE3 E1 E1 E2 DH-6 H USB B T E3 EL-001 J X-300 DH-5 DH-1 DH-2 DH-5 EF-1 X-400 ALR-03 ALR-11 VTAC-2 DH-3 ALR-02 TV DH-6 J X-302 DH-5 H USB DH-1EL-001TV ALR-02 DH-2DH-5 EF-1 ALR-11 X-400 ALR-03 VTAC-1 J X-300 DH-5 DB E5DH-3E6 DH-5DH-6 T E3E1 DL E8 E1 DL E8 JX-301 H USB JX-301 H USB T E3 E1 E1 DL E8 DL E8 DB E5 DH-1 E2 EL-001 J X-300 DH-5TV DH-3ALR-02 E6 DH-2DH-5 EF-1 ALR-11 X-400 ALR-03 VTAC-1 DH-5DH-6 JX-301 H USB JX-301 H USB ELECTRICAL KEY NOTES E1 E2 E3 E4 E5 E7 E6 PROVIDE SPEAKER/STROBE & STROBE IN BATHROOM IN HEARING IMPAIRED & ACCESSIBLE ROOMS. BATTERY MOTORIZED ROLLER SHADES. PROVIDE SINGLE GANG BOX WITH MUD RING FOR WIRELESS SWITCH PROVIDED WITH ROLLER SHADE AS SHOWN. ACCESSIBLE ROOMS ONLY, 46" TO CENTER AFF. THERMOSTAT SHOWN FOR COORDINATION ONLY. WIRING AND ROUGH IN BY M.C. MOTION SENSOR PROVIDED WITH THERMOSTAT, UTILIZE FOR SHUT DOWN OF LIGHTING 20 MINUTES AFTER UNOCCUPIED. PROVIDE OUTLET FOR MIRROR. REFER TO ARCH ELEVATIONS FOR LOCATION AND VERIFY ROUGH-IN HEIGHT WITH MIRROR MANUFACTURER. GFI RECEPTACLE AT SINK FEEDS MIRROR RECEPTACLE TO PROVIDE GFI PROTECTION. DOORBELL HARDWIRED TO DOORBELL LIGHT - PROVIDE SINGLE GANG BOX AND MOUNT AT 44" AFF TO CENTER OF BUTTON, EDWARDS 620 PUSHBUTTON & EDWARDS 592 TRANSFORMER OR EQUAL. PROVIDE A 120V CONNECTION TO TRANSFORMER LOCATED ABOVE ACCESSIBLE CEILING. CONNECT TO NEAREST CONVENIENCE OUTLET CIRCUIT. (FOR COMMUNICATION ROOMS ONLY) DOORBELL ON/OFF SWITCH FOR HEARING IMPAIRED ROOMS ONLY. LABEL DOORBELL, DH-5. STRIP LIGHT MOUNTED TO UNDERSIDE OF WARDROBE SHELF. LOCATE DUPLEX OUTLET ON WALL BEHIND WARDROBE UNIT. STRIP LIGHT PROVIDED BY MILLWORKER. COORDINATE LOCATION OF ACTIVATION SWITCH, SUCH THAT, LIGHTS ARE ACTIVATED WHEN WARDROBE DOORS OPEN. MILLWORKER TO PROVIDE WIRE MANAGEMENT TO CONCEAL WIRES LEADING FROM LIGHT TO OUTLET. MILLWORKER TO DRILL HOLE IN CLOSET BACK TO ALLOW LIGHT PLUG-IN. DOORBELL LIGHT FOR HEARING IMPAIRED ROOMS ONLY. PROVIDE SINGLE GANG BOX, EDWARDS 6536-G5 HORN/STOBE OR EQUAL. PROVIDE SINGLE GANG BOX. ALIGN WITH OTHER DEVICES AS SHOWN ON ARCHITECTURAL ELEVATIONS. PROVIDE JBOX IN CABINET FOR ALJ-01 UNDER CABINET LIGHTING PROVIDED WITH MILLWORK.. PROVIDE SWITCH ON WALL, PROVIDE 2-GANG JBOX FOR SWITCH/DRIVER PROVIDED WITH SHELF LA-001. E8 E9 E10 ELECTRICAL GENERAL NOTES 1. HEARING IMPAIRED ROOMS SHALL BE EQUIPPED WITH VISIBLE FIRE ALARMS AND NOTIFICATION DEVICES FOR DOOR BELL AND TELEPHONE. 2. HEARING IMPAIRED & ACCESSIBLE - GUEST ROOM STROBES SHALL FACE THE BED, BOTTOM OF LENS SHALL BE WITHIN 16 FEET OF PILLOWS. 117 CANDELA STROBE WHEN LOCATED WITHIN 24" OF CEILING, 110 CANDELA FOR ALL OTHER LOCATIONS MINIMUM 80" TO CENTER ABOVE FINISHED FLOOR. PROVIDE IN SLEEPING ROOM AND BATHROOM AREAS. STANDARD ROOMS - OMIT STROBE IN SLEEPING AREA AND BATHROOM. 3. VISUAL ALARMS TO BE FULLY VISIBLE FROM ALL AREAS OF ROOM. 4. GUEST ROOM SMOKE DETECTORS MUST BE SYSTEM PHOTOELECTRIC SMOKE DETECTORS WITH SOUNDER BASES AND BOTH POWERED AND MONITORED BY FACP. FA SOUNDER BASES TO PROVIDE MINIMUM AUDIBLE ALARM OF 85 DBA AT 10'-0" AND 75 DBA AT PILLOW. 5. REFER TO ARCHITECTURAL PLANS FOR LIST OF GUESTROOMS WITH ACCESSIBLE & HEARING IMPAIRED AND GUESTROOMS WITH CONNECTING FEATURES. 6. REFER TO MARRIOTT'S MODULE 14 FOR ALL FIRE ALARM REQUIREMENTS 7. REFER TO TYPICAL PANEL SCHEDULE FOR CIRCUITING IN GUEST ROOMS WITH PANELS AND ON OVERALL PLANS FOR GUESTROOMS WITHOUT PANELS. PROVIDE ARCH FAULT CIRCUIT INTERRUPTERS (AFCI) PER NEC IN ALL ROOMS WITH COOKING. FOR GENERAL OUTLETS PROVIDE MAXIMUM OF 9 OUTLETS ON A CIRCUIT. 8. ELECTRICAL DEVICES SHOWN FOR CIRCUITING--REFER TO ARCHITECTURAL ROOM PLANS AND ELEVATIONS FOR MOUNTING HEIGHTS AND GENERAL DIMENSIONING OF ALL ELECTRICAL DEVICES IN GUEST ROOMS AND TO COORDINATE PLACEMENT OF DEVICES WITHIN MILLWORK PARTITIONS. 9. BACK TO BACK DEVICES ARE NOT ALLOWED. ELECTRICAL CONTRACTOR MUST STAGGER ALL DEVICES AS REQUIRED TO MAINTAIN A 6" OFFSET BETWEEN ADJACENT GUEST ROOMS WHILE MAINTAINING RELATIVE POSITIONS AS SHOWN. NOTE: MAINTAINING A 6" OFFSET BETWEEN ELECTRICAL DEVICES WITH ADJACENT ROOMS SUPERSEDES DIMENSIONS. CONSULT ARCHITECT IF DISCREPANCIES. 10. ALL NON-LOCKING 120V 15A & 20A RECEPTACLES MOUNTED BELOW 5'-6" AFF IN GUESTROOMS TO BE TAMPER RESISTANT PER NEC. 11. ELECTRICAL WALL PLATE AND DEVICE COLOR (OUTLET & SWITCH) FOR GUESTROOM / GUESTROOM BATHROOM TO BE VERIFIED WITH INTERIOR DESIGN. 12 ALL DEVICES VISIBLE TO OCCUPANT ALL DEVICES TO BE DECORA STYLE IN GUESTROOMS. WHERE DEVICES ARE GANGED TOGETHER PROVIDE SUITABLE COVER PLATE FOR QUANTITY OF DEVICES SHOWN. DECORA OUTLETS TYPE LEGRAND T5325. USB OUTLETS SHALL BE LEGRAND T5632 13. E.C. TO VERIFY WITH AHJ THAT PANELS CAN BE MOUNTED BEHIND DOOR FOR GUEST ROOMS WITH PANELS AS NOTED ON PLANS. Engin ngir LLC8200 PEACHTREE AVE. ROCKFORD, MI 49341 P. 616-340-9627 SCALE: 1/4" = 1'-0" Aloft - Standard Q/Q A & B1 E-230 Enlarged Electrical Plan SCALE: 1/4" = 1'-0" Aloft - Standard King A & B2 E-230 Enlarged Electrical Plan SCALE: 1/4" = 1'-0" Aloft - KING C MOD3 E-230 Enlarged Electrical Plan SCALE: 1/4" = 1'-0" Aloft - ACC KING MOD4 E-230 Enlarged Electrical Plan SCALE: 1/4" = 1'-0" Aloft - ACC QQ CORNER MOD5 E-230 Enlarged Electrical Plan SCALE: 1/4" = 1'-0" Aloft - QQ CORNER MOD6 E-230 Enlarged Electrical Plan HEARING IMPAIRED ROOMS: A211, A302, A320, A426, A525 & A601 HEARING IMPAIRED ROOMS: A204, A309, A410, A503 HEARING IMPAIRED ROOMS: A615 HEARING IMPAIRED ROOMS: A315 P:\2018\2018388 Aloft-Element Carmel\Working Drawings\E230 -Carmel DB.dwg, 5/26/2020 2:15:51 PM, cll09/28/20 ALR-01 DW H EF-2 DH-5 DH-3 DH-1 HOOD COOKTOP 2P20 J MICRO DH-2 T E3 VTAC-3 E4 E9 X401 DH-6 E2 BPG2 USB ALJ-02-48 TVMOUNTING HEIGHT PER ADA USB E1 E1 E1 E7 J X-302 FRIG RECEPT GFI PROTECTED BY COUTERTOP RECEPTACLE (TYP.) X401 T E3E4 EF-2 DH-2 DH-1 DH-6 DH-3 VTAC-2 ALJ-02-48 BPG2TVH E1 USB DL E8 DH-3 M DH-7 USB USB X400 X401 T E3 E4 EF-2 DH-2 DH-1 DH-6 DH-3 VTAC-1 J DW FRIG COOKTOP 2P20 E10 ALJ-02-48 BPG2 TV H USB H E1 USB M DH-7 USB ALR-01 DB E5 MICRO HOOD E1 E2 X401 ALJ-02-48 H VTAC-1 USB T USB E3 H USB TVE1 EF-2 X401 DH-6 DH-3 ALJ-02-48 H VTAC-1 USB T USB TVJ E9 MICRO E2 EF-2 DH-1 DL E8 DL E8 E6 DH-5 E1 E3 E1 FRIG RECEPT GFI PROTECTED BY COUTERTOP RECEPTACLE (TYP.) J X-301 HUSB J X-301 J X-301 JX-301 J X-301 J X-301 J X-301 H USB J X-301 E2E2 E7 J DW COOKTOP 2P20 E10 HOOD/MICRO HOOD E7 E7 E7 E1 J MICRO E4 DH-1 E1 E4 E9 DL E8 TDH-6 DH-3 DB E5 E6 DH-5 FRIG RECEPT GFI PROTECTED BY COUTERTOP RECEPTACLE (TYP.) FRIG RECEPT GFI PROTECTED BY COUTERTOP RECEPTACLE (TYP.) FRIG RECEPT GFI PROTECTED BY COUTERTOP RECEPTACLE (TYP.) H X401 T E3 E4 EF-2 DH-2 DH-1 DH-6 DH-3 VTAC-3 J DW HOOD/ MICRO FRIG 2P20 COOKTOP E10 USB ALJ-02-48 BPG2 M DH-7 DH-5 TVUSB X400 E1 DB E5 DL E8 DL E8 E1 DL E8 E1 E7 DH-5E6 J X302 FRIG RECEPT GFI PROTECTED BY COUTERTOP RECEPTACLE (TYP.) EF-2 DH-1 DH-2 X401 DH-3 E7 J E9 FRIG MICRO ALJ-02-48 E4 TE3 H VTAC-1 USB USBH USB TVE1 E1 DL E8 DB E5 DLE8 DB E5 E1 DL E8 T E3 E1 DL E8 VTAC-1 USBTV H USB H USBJFRIG MICRO E7 E9 X401 DH-3 EF-2 DH-1 DH-2 ALJ-02-48 E4 H USB H USB USB TVT E3 X401 J FRIGMICRO E7 E9 DH-6 DH-3 E4 DH-1 DH-2 EF-2 ALJ-02-48 DH-6 DH-6 DH-5 E6 DH-5 E6 VTAC-1 J X301 JX301 E2 J X301 J X301 J X301 J X301 X401 ELECTRICAL KEY NOTES E1 E2 E3 E4 E5 E7 E6 PROVIDE SPEAKER/STROBE & STROBE IN BATHROOM IN HEARING IMPAIRED & ACCESSIBLE ROOMS. BATTERY MOTORIZED ROLLER SHADES. PROVIDE SINGLE GANG BOX WITH MUD RING FOR WIRELESS SWITCH PROVIDED WITH ROLLER SHADE AS SHOWN. ACCESSIBLE ROOMS ONLY, 46" TO CENTER AFF. THERMOSTAT SHOWN FOR COORDINATION ONLY. WIRING AND ROUGH IN BY M.C. MOTION SENSOR PROVIDED WITH THERMOSTAT, UTILIZE FOR SHUT DOWN OF LIGHTING 20 MINUTES AFTER UNOCCUPIED. PROVIDE OUTLET FOR MIRROR. REFER TO ARCH ELEVATIONS FOR LOCATION AND VERIFY ROUGH-IN HEIGHT WITH MIRROR MANUFACTURER. GFI RECEPTACLE AT SINK FEEDS MIRROR RECEPTACLE TO PROVIDE GFI PROTECTION. DOORBELL HARDWIRED TO DOORBELL LIGHT - PROVIDE SINGLE GANG BOX AND MOUNT AT 44" AFF TO CENTER OF BUTTON, EDWARDS 620 PUSHBUTTON & EDWARDS 592 TRANSFORMER OR EQUAL. PROVIDE A 120V CONNECTION TO TRANSFORMER LOCATED ABOVE ACCESSIBLE CEILING. CONNECT TO NEAREST CONVENIENCE OUTLET CIRCUIT. (FOR COMMUNICATION ROOMS ONLY) DOORBELL ON/OFF SWITCH FOR HEARING IMPAIRED ROOMS ONLY. LABEL DOORBELL, DH-5. STRIP LIGHT MOUNTED TO UNDERSIDE OF WARDROBE SHELF. LOCATE DUPLEX OUTLET ON WALL BEHIND WARDROBE UNIT. STRIP LIGHT PROVIDED BY MILLWORKER. COORDINATE LOCATION OF ACTIVATION SWITCH, SUCH THAT, LIGHTS ARE ACTIVATED WHEN WARDROBE DOORS OPEN. MILLWORKER TO PROVIDE WIRE MANAGEMENT TO CONCEAL WIRES LEADING FROM LIGHT TO OUTLET. MILLWORKER TO DRILL HOLE IN CLOSET BACK TO ALLOW LIGHT PLUG-IN. DOORBELL LIGHT FOR HEARING IMPAIRED ROOMS ONLY. PROVIDE SINGLE GANG BOX, EDWARDS 6536-G5 HORN/STOBE OR EQUAL. PROVIDE SINGLE GANG BOX. ALIGN WITH OTHER DEVICES AS SHOWN ON ARCHITECTURAL ELEVATIONS. PROVIDE JBOX IN CABINET FOR ALJ-01 UNDER CABINET LIGHTING PROVIDED WITH MILLWORK.. PROVIDE SWITCH ON WALL, PROVIDE 2-GANG JBOX FOR SWITCH/DRIVER PROVIDED WITH SHELF LA-001. E8 E9 E10 ELECTRICAL GENERAL NOTES 1. HEARING IMPAIRED ROOMS SHALL BE EQUIPPED WITH VISIBLE FIRE ALARMS AND NOTIFICATION DEVICES FOR DOOR BELL AND TELEPHONE. 2. HEARING IMPAIRED & ACCESSIBLE - GUEST ROOM STROBES SHALL FACE THE BED, BOTTOM OF LENS SHALL BE WITHIN 16 FEET OF PILLOWS. 117 CANDELA STROBE WHEN LOCATED WITHIN 24" OF CEILING, 110 CANDELA FOR ALL OTHER LOCATIONS MINIMUM 80" TO CENTER ABOVE FINISHED FLOOR. PROVIDE IN SLEEPING ROOM AND BATHROOM AREAS. STANDARD ROOMS - OMIT STROBE IN SLEEPING AREA AND BATHROOM. 3. VISUAL ALARMS TO BE FULLY VISIBLE FROM ALL AREAS OF ROOM. 4. GUEST ROOM SMOKE DETECTORS MUST BE SYSTEM PHOTOELECTRIC SMOKE DETECTORS WITH SOUNDER BASES AND BOTH POWERED AND MONITORED BY FACP. FA SOUNDER BASES TO PROVIDE MINIMUM AUDIBLE ALARM OF 85 DBA AT 10'-0" AND 75 DBA AT PILLOW. 5. REFER TO ARCHITECTURAL PLANS FOR LIST OF GUESTROOMS WITH ACCESSIBLE & HEARING IMPAIRED AND GUESTROOMS WITH CONNECTING FEATURES. 6. REFER TO MARRIOTT'S MODULE 14 FOR ALL FIRE ALARM REQUIREMENTS 7. REFER TO TYPICAL PANEL SCHEDULE FOR CIRCUITING IN GUEST ROOMS WITH PANELS AND ON OVERALL PLANS FOR GUESTROOMS WITHOUT PANELS. PROVIDE ARCH FAULT CIRCUIT INTERRUPTERS (AFCI) PER NEC IN ALL ROOMS WITH COOKING. FOR GENERAL OUTLETS PROVIDE MAXIMUM OF 9 OUTLETS ON A CIRCUIT. 8. ELECTRICAL DEVICES SHOWN FOR CIRCUITING--REFER TO ARCHITECTURAL ROOM PLANS AND ELEVATIONS FOR MOUNTING HEIGHTS AND GENERAL DIMENSIONING OF ALL ELECTRICAL DEVICES IN GUEST ROOMS AND TO COORDINATE PLACEMENT OF DEVICES WITHIN MILLWORK PARTITIONS. 9. BACK TO BACK DEVICES ARE NOT ALLOWED. ELECTRICAL CONTRACTOR MUST STAGGER ALL DEVICES AS REQUIRED TO MAINTAIN A 6" OFFSET BETWEEN ADJACENT GUEST ROOMS WHILE MAINTAINING RELATIVE POSITIONS AS SHOWN. NOTE: MAINTAINING A 6" OFFSET BETWEEN ELECTRICAL DEVICES WITH ADJACENT ROOMS SUPERSEDES DIMENSIONS. CONSULT ARCHITECT IF DISCREPANCIES. 10. ALL NON-LOCKING 120V 15A & 20A RECEPTACLES MOUNTED BELOW 5'-6" AFF IN GUESTROOMS TO BE TAMPER RESISTANT PER NEC. 11. ELECTRICAL WALL PLATE AND DEVICE COLOR (OUTLET & SWITCH) FOR GUESTROOM / GUESTROOM BATHROOM TO BE VERIFIED WITH INTERIOR DESIGN. 12 ALL DEVICES VISIBLE TO OCCUPANT ALL DEVICES TO BE DECORA STYLE IN GUESTROOMS. WHERE DEVICES ARE GANGED TOGETHER PROVIDE SUITABLE COVER PLATE FOR QUANTITY OF DEVICES SHOWN. DECORA OUTLETS TYPE LEGRAND T5325. USB OUTLETS SHALL BE LEGRAND T5632 13. E.C. TO VERIFY WITH AHJ THAT PANELS CAN BE MOUNTED BEHIND DOOR FOR GUEST ROOMS WITH PANELS AS NOTED ON PLANS. Engi n ngir LLC8200 PEACHTREE AVE. ROCKFORD, MI 49341 P. 616-340-9627 SCALE: 1/4" = 1'-0" Element - Studio Queen A&B&C1 E-231 Enlarged Electrical Plan HEARING IMPAIRED ROOMS: 203 & 510 SCALE: 1/4" = 1'-0" Element - Standard King- A & B2 E-231 Enlarged Electrical Plan SCALE: 1/4" = 1'-0" Element - Standard King - C3 E-231 Enlarged Electrical Plan SCALE: 1/4" = 1'-0" Element - Standard King - D4 E-231 Enlarged Electrical Plan SCALE: 1/4" = 1'-0" Element - Studio King5 E-231 Enlarged Electrical Plan SCALE: 1/4" = 1'-0" Element - Acc Studio King6 E-231 Enlarged Electrical Plan SCALE: 1/4" = 1'-0" Element - Acc Std King Tub7 E-231 Enlarged Electrical Plan SCALE: 1/4" = 1'-0" Element - Acc Std King Sh8 E-231 Enlarged Electrical Plan SCALE: 1/4" = 1'-0" Element - Acc Studio Queen9 E-231 Enlarged Electrical Plan HEARING IMPAIRED ROOMS: 613 HEARING IMPAIRED ROOMS: 206, 324, 411 & 505 HEARING IMPAIRED ROOM: E318HEARING IMPAIRED ROOM: E418 P:\2018\2018388 Aloft-Element Carmel\Working Drawings\E231 -Carmel DB.dwg, 5/26/2020 2:16:31 PM, cll09/28/20 EF-2 DH-1 DH-2 X401 DH-3 FRIG ALJ-02-48 E4 T E3 H VTAC-1 USB USB H USB TVX401 DH-3 T E3 USB E1 H USB H USB FRIG MICRO E4 DH-2 EF-2 E1 ALJ-02-48 MICRO E7 E7 VTAC-1 TVJ X301JX301 JX301 J X301 E1 DL E8 DL E8 E1 DB E5 EF-2 DH-1 DH-2 ALJ-02-48 E4 E1 EF-2 DH-1 DH-2 E4 ALJ-02-48TV TVTVTVJ DW FRIGE9 HOOD/ MICRO 2P20 COOKTOP USBUSB J DW FRIGE9 HOOD/ MICRO 2P20 COOKTOP H USB H USB H USB H USB X400 VTAC VTAC-2 X401 X400 X401 E7 E7 E7 DL E1 E8 DH-5 DH-6 DH-3 DH-5 DH-6 DH-3 DH-5 X401 3X401 3 DH-4 3 DH-4 3 DH-4 DH-4 E1 E1 DH-5 E6 E2 T E3 T E3 FRIG RECEPT GFI PROTECTED BY COUTERTOP RECEPTACLE (TYP.) J X301 J X301 J X301 J X301 E2 FRIG RECEPT GFI PROTECTED BY COUTERTOP RECEPTACLE (TYP.) HE4 EF-2 DH-2 DH-1 VTAC-2 J DW HOOD/ MICRO FRIG 2P20 COOKTOP E9 USB ALJ-02-48 TV X401 BPG2 X400 TV HUSB E7 USB T E33DH-6 DH-4 E4 EF-2 DH-2 DH-1 VTAC-2 J DW HOOD/ MICRO FRIG 2P20 COOKTOP E9 ALJ-02-48 TV X401 BPG2 X400 TV E7 USB T E3 3DH-6 DH-4 E2 TV TV E7 USB J DW HOOD/ MICRO E9 FRIG X401 X400 BPG2 3DH-6 DH-4 T E3 E4 DH-2 DH-1 EF-2 ALJ-02-48 E7 E7 E7 3 DH-4 3DH-4 3DH-4 E1 E1 E1 E1 E1 DB E5 E6 DL E8 DL E8 DH-5 E1 VTAC-2 FRIG RECEPT GFI PROTECTED BY COUTERTOP RECEPTACLE (TYP.) J X-301JX-301 HUSB HUSB J X-301JX-301 HUSB HUSB J X-301JX-301 ELECTRICAL KEY NOTES E1 E2 E3 E4 E5 E7 E6 PROVIDE SPEAKER/STROBE & STROBE IN BATHROOM IN HEARING IMPAIRED & ACCESSIBLE ROOMS. BATTERY MOTORIZED ROLLER SHADES. PROVIDE SINGLE GANG BOX WITH MUD RING FOR WIRELESS SWITCH PROVIDED WITH ROLLER SHADE AS SHOWN. ACCESSIBLE ROOMS ONLY, 46" TO CENTER AFF. THERMOSTAT SHOWN FOR COORDINATION ONLY. WIRING AND ROUGH IN BY M.C. MOTION SENSOR PROVIDED WITH THERMOSTAT, UTILIZE FOR SHUT DOWN OF LIGHTING 20 MINUTES AFTER UNOCCUPIED. PROVIDE OUTLET FOR MIRROR. REFER TO ARCH ELEVATIONS FOR LOCATION AND VERIFY ROUGH-IN HEIGHT WITH MIRROR MANUFACTURER. GFI RECEPTACLE AT SINK FEEDS MIRROR RECEPTACLE TO PROVIDE GFI PROTECTION. DOORBELL HARDWIRED TO DOORBELL LIGHT - PROVIDE SINGLE GANG BOX AND MOUNT AT 44" AFF TO CENTER OF BUTTON, EDWARDS 620 PUSHBUTTON & EDWARDS 592 TRANSFORMER OR EQUAL. PROVIDE A 120V CONNECTION TO TRANSFORMER LOCATED ABOVE ACCESSIBLE CEILING. CONNECT TO NEAREST CONVENIENCE OUTLET CIRCUIT. (FOR COMMUNICATION ROOMS ONLY) DOORBELL ON/OFF SWITCH FOR HEARING IMPAIRED ROOMS ONLY. LABEL DOORBELL, DH-5. STRIP LIGHT MOUNTED TO UNDERSIDE OF WARDROBE SHELF. LOCATE DUPLEX OUTLET ON WALL BEHIND WARDROBE UNIT. STRIP LIGHT PROVIDED BY MILLWORKER. COORDINATE LOCATION OF ACTIVATION SWITCH, SUCH THAT, LIGHTS ARE ACTIVATED WHEN WARDROBE DOORS OPEN. MILLWORKER TO PROVIDE WIRE MANAGEMENT TO CONCEAL WIRES LEADING FROM LIGHT TO OUTLET. MILLWORKER TO DRILL HOLE IN CLOSET BACK TO ALLOW LIGHT PLUG-IN. DOORBELL LIGHT FOR HEARING IMPAIRED ROOMS ONLY. PROVIDE SINGLE GANG BOX, EDWARDS 6536-G5 HORN/STOBE OR EQUAL. PROVIDE SINGLE GANG BOX. ALIGN WITH OTHER DEVICES AS SHOWN ON ARCHITECTURAL ELEVATIONS. PROVIDE JBOX IN CABINET FOR ALJ-01 UNDER CABINET LIGHTING PROVIDED WITH MILLWORK.. PROVIDE SWITCH ON WALL, PROVIDE 2-GANG JBOX FOR SWITCH/DRIVER PROVIDED WITH SHELF LA-001. E8 E9 E10 ELECTRICAL GENERAL NOTES 1. HEARING IMPAIRED ROOMS SHALL BE EQUIPPED WITH VISIBLE FIRE ALARMS AND NOTIFICATION DEVICES FOR DOOR BELL AND TELEPHONE. 2. HEARING IMPAIRED & ACCESSIBLE - GUEST ROOM STROBES SHALL FACE THE BED, BOTTOM OF LENS SHALL BE WITHIN 16 FEET OF PILLOWS. 117 CANDELA STROBE WHEN LOCATED WITHIN 24" OF CEILING, 110 CANDELA FOR ALL OTHER LOCATIONS MINIMUM 80" TO CENTER ABOVE FINISHED FLOOR. PROVIDE IN SLEEPING ROOM AND BATHROOM AREAS. STANDARD ROOMS - OMIT STROBE IN SLEEPING AREA AND BATHROOM. 3. VISUAL ALARMS TO BE FULLY VISIBLE FROM ALL AREAS OF ROOM. 4. GUEST ROOM SMOKE DETECTORS MUST BE SYSTEM PHOTOELECTRIC SMOKE DETECTORS WITH SOUNDER BASES AND BOTH POWERED AND MONITORED BY FACP. FA SOUNDER BASES TO PROVIDE MINIMUM AUDIBLE ALARM OF 85 DBA AT 10'-0" AND 75 DBA AT PILLOW. 5. REFER TO ARCHITECTURAL PLANS FOR LIST OF GUESTROOMS WITH ACCESSIBLE & HEARING IMPAIRED AND GUESTROOMS WITH CONNECTING FEATURES. 6. REFER TO MARRIOTT'S MODULE 14 FOR ALL FIRE ALARM REQUIREMENTS 7. REFER TO TYPICAL PANEL SCHEDULE FOR CIRCUITING IN GUEST ROOMS WITH PANELS AND ON OVERALL PLANS FOR GUESTROOMS WITHOUT PANELS. PROVIDE ARCH FAULT CIRCUIT INTERRUPTERS (AFCI) PER NEC IN ALL ROOMS WITH COOKING. FOR GENERAL OUTLETS PROVIDE MAXIMUM OF 9 OUTLETS ON A CIRCUIT. 8. ELECTRICAL DEVICES SHOWN FOR CIRCUITING--REFER TO ARCHITECTURAL ROOM PLANS AND ELEVATIONS FOR MOUNTING HEIGHTS AND GENERAL DIMENSIONING OF ALL ELECTRICAL DEVICES IN GUEST ROOMS AND TO COORDINATE PLACEMENT OF DEVICES WITHIN MILLWORK PARTITIONS. 9. BACK TO BACK DEVICES ARE NOT ALLOWED. ELECTRICAL CONTRACTOR MUST STAGGER ALL DEVICES AS REQUIRED TO MAINTAIN A 6" OFFSET BETWEEN ADJACENT GUEST ROOMS WHILE MAINTAINING RELATIVE POSITIONS AS SHOWN. NOTE: MAINTAINING A 6" OFFSET BETWEEN ELECTRICAL DEVICES WITH ADJACENT ROOMS SUPERSEDES DIMENSIONS. CONSULT ARCHITECT IF DISCREPANCIES. 10. ALL NON-LOCKING 120V 15A & 20A RECEPTACLES MOUNTED BELOW 5'-6" AFF IN GUESTROOMS TO BE TAMPER RESISTANT PER NEC. 11. ELECTRICAL WALL PLATE AND DEVICE COLOR (OUTLET & SWITCH) FOR GUESTROOM / GUESTROOM BATHROOM TO BE VERIFIED WITH INTERIOR DESIGN. 12 ALL DEVICES VISIBLE TO OCCUPANT ALL DEVICES TO BE DECORA STYLE IN GUESTROOMS. WHERE DEVICES ARE GANGED TOGETHER PROVIDE SUITABLE COVER PLATE FOR QUANTITY OF DEVICES SHOWN. DECORA OUTLETS TYPE LEGRAND T5325. USB OUTLETS SHALL BE LEGRAND T5632 13. E.C. TO VERIFY WITH AHJ THAT PANELS CAN BE MOUNTED BEHIND DOOR FOR GUEST ROOMS WITH PANELS AS NOTED ON PLANS. Engi n ngir LLC8200 PEACHTREE AVE. ROCKFORD, MI 49341 P. 616-340-9627 SCALE: 1/4" = 1'-0" Element - 1 Bedroom A&B1 E-231 Enlarged Electrical Plan SCALE: 1/4" = 1'-0" Element - 1 Bedroom C2 E-231 Enlarged Electrical Plan SCALE: 1/4" = 1'-0" Element - Acc 1 Bedroom3 E-230 Enlarged Electrical Plan SCALE: 1/4" = 1'-0" Element - Conference Suite4 E-231 Enlarged Electrical Plan SCALE: 1/4" = 1'-0" Element - Acc Conference Suite5 E-231 Enlarged Electrical Plan SCALE: 1/4" = 1'-0" Element - King Common A&B6 E-231 Enlarged Electrical Plan SCALE: 1/4" = 1'-0" Element - Acc King Common7 E-231 Enlarged Electrical Plan HEARING IMPAIRED ROOM: E313 HEARING IMPAIRED ROOM: E119 P:\2018\2018388 Aloft-Element Carmel\Working Drawings\E232 -Carmel DB.dwg, 5/26/2020 2:17:13 PM, cll09/28/20 24 X 48 24 X 24 24 X 4218 X 4218 X 4218 X 4218 X 4218 X 4224 X 5424 X 2421 X 48 21 X 3621 X 42 21 X 42 21 X 42 21 X 42 21 X 6021 X 60 21 X 60 21 X 60 21 X 4221 X 4221 X 42 21 X 4221 X 42 21 X 4224 X 54 24 X 36BPK2BPK2S 1B- WR 11 1A- TV 1A- 60" 60" 1A- 60" 1A- 96" 96" 111A- W 1B- WR CR TV 1A- 96" K2-1 K2-76 K2-2 K2-2 K2-4 F JVERIFY LOCATION K2-6/8 K2-10 K2-12/14 F JVERIFY LOCATION K2-16/18 K2-20/22/24 RE: ONELINE/E600 RE: ONELINE/E600 K2-59/61 K2-3/5 K2-7/9 K2-11 K2-13 K2-27 K2-38 1 K2-40 1 3#10+G 3#10+G K2-15/17 1 K2S-19 K2-72 1 K2S-7/9/11 K2S-13/15/17 RE: ONELINE/E600 K2-23 K2-25 K2-21 K2-19 11 1 1 K2-63 K2-63 K2-65 F J VERIFY LOCATION K2-67/69 K2-71 1 K2-42 1 K2-41 1 K2-29/31/33 K2-35/37/39 K2-43 K2-45/47 3#10+G K2-49 1 K2-57 1 K2-55 1 K2-51/53 K2-73 K2-70 55B 55B.1 55B.2 57B 59B 63B 64B 56B 47B C.O. C.O. C.O. 29B 33B 36B 38B 26B 28B 28B.1 28B.2 28B.3 23B 23B 1B 3B 5B 23B 1B 23B 14B 75B 77B 80B 119A 125A 125A.1 125A.2 127A 126A 85A 113A 87A 108A 109A 93A 106A 95A 99A C.O. 97A 137A 1 1 1 1 1 1 1 K2-74 K2-74 K2-74 F 3P20 DP1 EF-13 2 HP F 3P20 DP1 EF-142 HP F 3P20 DP1 EF-15 2 HP RE: ROOF PLAN/E107 F K2S-1/3/5 MAU-3 ON ROOF INTERLOCK WITH EF-13 & EF-14 & EF-15 & KITCHEN HOOD CONTROLS 1C-79/81 FC-3 J J J J J J J J J J J J J J J J J J J J J J J S J J J 22 X 3914 X 4214 X 42 38" USB 38" USB 38" USB 38" USB 6A15 J SIGNAGE CR 1 K2-48 K2-81/83 K2-44 K2-50 1 K2-52/54 K2-56 1 K2-581 K2-68 1 K2-60 K2-60 K2-62 F J VERIFY LOCATION K2-64/66 159A 157A 153A 148A 139A 166A 173A 181A 174A 175A 176A 174A.2 174A.1 1 K2-44 J J J B B S S S S S GENERAL POWER NOTES: 1. 2. 3. POWER KEY NOTES: 1 REFER TO FOOD SERVICE SCHEDULE FS FOR FINAL ELECTRICAL REQUIREMENTS AND MOUNTING HEIGHTS. SCHEDULE SHOWN HERE FOR COORDINATION ONLY. ALL 120V 15A & 20A RECEPTACLES TO BE GFCI PROTECTED, REFER TO PANEL SCHEDULE THIS SHEET FOR GFCI BREAKERS. COORDINATE WITH DISCONNECTS WITH FOOD SERVICE EQUIPMENT LAYOUT. RECEPTACLE PROTECTED WITH GFCI BREAKER. Engin ngir LLC8200 PEACHTREE AVE. ROCKFORD, MI 49341 P. 616-340-9627 SCALE: 1/4" = 1'-0" POWER & TECHNOLOGY3 E300 ALOFT KITCHEN SCALE: 1/4" = 1'-0" POWER & TECHNOLOGY4 E300 ALOFT KITCHEN P:\2018\2018388 Aloft-Element Carmel\Working Drawings\E300 -Carmel DB.dwg, 5/26/2020 1:49:14 PM, cll09/28/20 24 X 48 24 X 42 24 X 36 24 X 36 24 X 36 24 X 3624 X 4824 X 4224 X 54BPK1W F 3P20 DP1 EF-16 2 HP F 3P20 DP1 EF-17 2 HP 4E K1-1/3/5 1 15E K1-7 19E K1-9/111 49E 27E 1 K1-7 29EK1-2 29E.1K1-2 29E.2 33E F JVERIFY LOCATION 34E K1-4 K1-6/8 1K1-15 38E 3#10+G K1-17/19 47E 48E3#10+G K1-21/23 1 K1-25 55E 1K1-27 58E 1K1-29 J 59E K1S-8/10/12 K1S-2/4/6 67E K1-22 K1-20 68E/77E 68E.1 1 K1S-1/3/5 75E 76E 1 K1-10 68E.2/77E.2 77E.1 78E 1 K1-12 C.O. K1-39 C.O. K1-39 F RE: ONELINE/E600 MAU-4 ON CEILING INTERLOCK WITH EF-16 & EF-17 & KITCHEN HOOD CONTROLS F 2P20 1C-75/77 FC-7 1/2 HP J J J J J J J J JJ J J JBPK1S 83E 1 K1-14 1K1-18 85E1K1-16 84E GENERAL POWER NOTES: 1. 2. 3. POWER KEY NOTES: 1 REFER TO FOOD SERVICE SCHEDULE FS FOR FINAL ELECTRICAL REQUIREMENTS AND MOUNTING HEIGHTS. SCHEDULE SHOWN HERE FOR COORDINATION ONLY. ALL 120V 15A & 20A RECEPTACLES TO BE GFCI PROTECTED, REFER TO PANEL SCHEDULE THIS SHEET FOR GFCI BREAKERS. COORDINATE WITH DISCONNECTS WITH FOOD SERVICE EQUIPMENT LAYOUT. RECEPTACLE PROTECTED WITH GFCI BREAKER. Engin ngir LLC8200 PEACHTREE AVE. ROCKFORD, MI 49341 P. 616-340-9627 SCALE: 1/4" = 1'-0" 1 E300 ELEMENT KITCHEN POWER & TECHNOLOGY SCALE: 1/4" = 1'-0" POWER & TECHNOLOGY2 E300 ELEMENT KITCHEN C C G ELECT. EQUIPMENT CONTACTOR 480V. ELECT. EQUIPMENT CONTACTOR 120/208V. CR-a CR-b GAS SOLENOID NORMALLY CLOSED CR-C 2#14, 1/2"C. BY ELECTRICAL CONTRACTOR 480V. 3-PH. 3#12, 1/2"C. BY ELECTRICAL CONTRACTOR TO TEMPERATURE CONTROL PANEL BY TEMPERATURE CONTROL CONTRACTOR INTERLOCK SUPPLY AIR FAN TO AUXILLARY CONTACT OF EXHAUST FAN STARTER 480V. 3-PH. 4#14, 1/2"C. BY ELECTRICAL CONTRACTOR 3#12, 1/2"C. BY ELECTRICAL CONTRACTOR POWER RELAY IN NEMA 1 ENCLOSURE WITH 1 NORMALLY CLOSED HP RATED CONTACT FOR LOAD. FURNISHED, INSTALLED & WIRED BY ELECTRICAL CONTRACTOR C.S./F.D.S. PR FLUSH MOUNTED HOOD CONTROL PANEL ON FACE OF HOOD. (FURNISHED WITH HOOD) F F NON-FUSED DISCONNECT NON-FUSED DISCONNECT WIRE NORMALLY OPEN AUXILLARY CONTACT IN SERIES WITH SUPPLY AIR FAN CONTROL CIRCUIT OF MAKE-UP AIR UNIT. EXHAUST FAN MAKE-UP AIR UNIT CR 120V. CIRCUIT 'RESET' WIRE SYSTEM SO THAT WHEN FIRE PROTECTION SYSTEM IS ACTIVATED EXHAUST FAN CONTNUES TO RUN AND MAKE-UP AIR UNIT FAN SHUTS DOWN. NOTE: N.T.S.P:\2018\2018388 Aloft-Element Carmel\Working Drawings\E300 -Carmel DB.dwg, 5/26/2020 1:52:51 PM, cll09/28/20 EC SHALL WIRE INTAKE DOORS FOR LAUNDRY CHUTE PER CHUTE MANUFACTURER'S ELECTRICAL INTERLOCK WIRING DIAGRAM. INSTALL AND WIRE MANUAL ON/OFF SWITCH, PROVIDED WITH UNIT IN LAUNDRY ROOM . SMOKE DETECTOR TO BE WIRED TO DOOR INTERLOCK SO THAT INTERLOCKS WILL NOT OPERATE UPON ACTIVATION OF SMOKE DETECTOR, TYPICAL EACH FLOOR. PROVIDE 120V POWER TO INTAKE DOOR AND RUN 4 WIRES BETWEEN FLOORS TO EACH INTAKE DOOR. CONNECT ALL SMOKE DAMPERS TO 120V EMERGENCY CIRCUIT AS SHOWN, COORDINATE VOLTAGE WITH SUPPLIER. CONNECT TO FIRE ALARM SYSTEM. VERIFY QUANTITY AND LOCATIONS WITH MECHANICAL PLANS. PROVIDE TWO-WAY COMMUNICATION SYSTEMS. VIKING E-1600-20A WITH MASTER STATION AT RECEPTION DESK AND CENTRAL CONTROL UNIT IN FIRE COMMAND ROOM CONTROL EF WITH LIGHT SWITCH WEATHERPROOF HORN STROBE TO BE LOCATED ON EXTERIOR OF BUILDING 8'-0" AFF AT FIRE SUPPRESSION CONNECTION, STROBE TO ACTIVATED BY FIRE PROTECTION FLOW SWITCHES. COORDINATE LOCATION. GANG TOILET EXHAUST FANS TO OPERATE WITH LIGHTING, PROVIDE 120V AUXILIARY RELAY WATTSTOPPER S120/277 C-P OR EQUAL COORDINATE LOCATIONS OF ALL EQUIPMENT IN ELEVATOR EQUIPMENT ROOM/HOIST ROOM AND PIT WITH ELEVATOR SHOP DRAWINGS PRIOR TO ROUGH-IN. CONNECT EMERGENCY SHUT-DOWN OF ELEVATOR AS REQUIRED. SEQUENCE EQUIPMENT TO SHUT-DOWN THE ELEVATOR BY SMOKE DETECTORS WHEN REQUIRED. ELECTRICAL CONTRACTOR SHALL REFERENCE ELEVATOR SPECIFICATIONS AND COORDINATE ALL REQUIREMENTS WITH ELEVATOR MANUFACTURER FOR ALL ELECTRICAL REQUIREMENTS PRIOR TO ROUGH-IN. COORDINATE QUANTITY & LOCATION OF FIRE SUPPRESSION RISERS AND TAMPER SWITCHES WITH FIRE SUPPRESSION PLANS. VERIFY WITH STATE CODE TO PROVIDE SMOKE DETECTION FOR ELEVATOR, PROVIDE AND INSTALLED BY E.C. CONNECT TO FIRE ALARM SYSTEM UNLESS NOT ALLOWED BY STATE CODE. PROVIDE POWER AND CONTROL TO SIGNAGE, VERIFY EXACT LOCATION WITH ARCHITECTURAL ELEVATIONS AND FINAL CONNECTIONS WITH SIGNAGE SHOP DRAWINGS ELEV. SUMP PUMP, PROVIDE POWER TO CONTROL PANEL. PROVIDED WITH UNIT AND WIRE PER MANUFACTURERS REQUIREMENTS. COORDINATE LOCATION W/PLUMBING PLANS. VERIFY WITH STATE CODE TO PROVIDE SMOKE DETECTION FOR ELEVATOR, PROVIDE AND INSTALLED BY E.C. CONNECT TO FIRE ALARM SYSTEM UNLESS NOT ALLOWED BY STATE CODE. PROVIDE POWER TO MOTORIZED PROJECTION SCREEN AND INSTALL CONTROLS PROVIDED WITH SCREENS AS SHOWN. PROVIDE SINGLE GANG BOX AT 46" A.F.F. FOR RF BLIND CONTROLLER PROVIDED WITH BLINDS. PROVIDE RECEPTACLE AT TOP RIGHT OF EACH SHADE FOR SHADE TO PLUG INTO. COORDINATE EXACT LOCATION WITH SUPPLIER/INSTALLER. REFER TO ARCHITECTURAL MILLWORK DETAILS FOR LOCATION OF ALL OUTLETS LOCATED AT CABINETS. REFER TO ARCHITECTURAL ELEVATIONS FOR MOUNTING HEIGHTS OF OUTLET/TV JACK. PROVIDE POWER TO DOOR OPERATORS, MOTION SENSOR INTEGRAL WITH DOOR. COORDINATE WITH DOOR SUPPLIER INSTALLER PROVIDE 1/2" CONDUIT TO ACCESSIBLE CEILING SPACE AND SINGLE GANG BOX FOR ALL MECHANICAL WALL MOUNTED TEMPERATURE SENSORS, SEE MECHANICAL PLANS FOR LOCATIONS. PROVIDE F.A. CONNECTION FOR LOCAL AUXILIARY SMOKE ALARM CONTACT AND 120V POWER FOR ELEVATOR SMOKE CURTAIN. ALL FOUR SMOKE CURTAINS ARE CONNECTED TO THE SAME EMERGENCY CIRCUIT AS SHOWN. SYSTEM WILL NOT DEPLOY ON GENERAL ALARM. SCREEN REWIND SWITCH DROPS DOWN WITH CURTAIN. PROVIDE 1/2" CONDUIT TO ACCESSIBLE CEILING SPACE AND SINGLE GANG BOX FOR ALL MECHANICAL WALL MOUNTED TEMPERATURE SENSORS, SEE MECHANICAL PLANS FOR LOCATIONS. 1 2 4 5 6 7 8 9 10 15 12 13 14 3 11 16 17 GENERAL POWER NOTES: 1. 2. 3. 4. 5. 6. 7. POWER KEY NOTES: ALL 15A & 20A 120V NON-LOCKING RECEPTACLES WITHIN CHILDCARE AREAS (AGES 7 & UNDER) SHALL BE LISTED TAMPER RESISTANT PER NEC 406.12. THIS INCLUDES GUEST ROOMS. MOUNT PANELS, TRANSFORMERS, DISCONNECT SWITCHES, AND COMBINATION MOTOR STARTERS WITH ADEQUATE CLEARANCES IN ACCORDANCE WITH NEC 110. VOLTAGE DROP TO MEET ASHRAE 90.1 (2007) ELEMENT ROOMS WHERE PANEL IS INDICATED - LABEL PANELS IN EACH ROOM WITH FINAL ROOM NUMBERS, COORDINATE WITH ARCHITECT FOR FINAL ROOM NUMBERING. DENOTED ON PLAN AS BPG (FLOOR #)-XX. "XX" DENOTE ROOM NUMBER INSTALL FIRE ALARM PER MARRIOTT'S MODULE 14 STANDARDS INSTALL PER LATEST NEC CODE: 2008 NEC NOT ALL POWER KEY NOTES ARE USED ON EACH FLOOR. 18 19 20 CR I F.A.A.1A-39 WR 1A-39 WR 14 1C-53 1C-44 141C-53 1C-54 1A-39 1A-35 1A-35 38" 1A-37 AC 1A-55 AC 1A-55 AC1A-55 1C-43 14 D DOOR DOOR 1C-54 S 8S8 S 7 CR I 1B-20 1B-2 1B-2 1B-53 AC1A-34 1B-24 WR 1B-59 1B-57 1B-57 F.A.A.D DOOR DOOR S 12 S11S11 UP FS TS8 1B-11 1B-11 WR ECH-11500W 1B-49 F Engin ngir LLC8200 PEACHTREE AVE. ROCKFORD, MI 49341 P. 616-340-9627 SCALE: 1/4" = 1'-0" 1 EP228 ENLARGED FIRST FLOOR - POWER SCALE: 1/4" = 1'-0" 2 EP228 ENLARGED FIRST FLOOR - POWER SCALE: 1/4" = 1'-0" 3 EP228 ENLARGED FIRST FLOOR - POWER P:\2018\2018388 Aloft-Element Carmel\Working Drawings\EP228 -Carmel DB.dwg, 5/26/2020 2:55:43 PM, cll09/28/20 EC SHALL WIRE INTAKE DOORS FOR LAUNDRY CHUTE PER CHUTE MANUFACTURER'S ELECTRICAL INTERLOCK WIRING DIAGRAM. INSTALL AND WIRE MANUAL ON/OFF SWITCH, PROVIDED WITH UNIT IN LAUNDRY ROOM . SMOKE DETECTOR TO BE WIRED TO DOOR INTERLOCK SO THAT INTERLOCKS WILL NOT OPERATE UPON ACTIVATION OF SMOKE DETECTOR, TYPICAL EACH FLOOR. PROVIDE 120V POWER TO INTAKE DOOR AND RUN 4 WIRES BETWEEN FLOORS TO EACH INTAKE DOOR. CONNECT ALL SMOKE DAMPERS TO 120V EMERGENCY CIRCUIT AS SHOWN, COORDINATE VOLTAGE WITH SUPPLIER. CONNECT TO FIRE ALARM SYSTEM. VERIFY QUANTITY AND LOCATIONS WITH MECHANICAL PLANS. PROVIDE TWO-WAY COMMUNICATION SYSTEMS. VIKING E-1600-20A WITH MASTER STATION AT RECEPTION DESK AND CENTRAL CONTROL UNIT IN FIRE COMMAND ROOM CONTROL EF WITH LIGHT SWITCH WEATHERPROOF HORN STROBE TO BE LOCATED ON EXTERIOR OF BUILDING 8'-0" AFF AT FIRE SUPPRESSION CONNECTION, STROBE TO ACTIVATED BY FIRE PROTECTION FLOW SWITCHES. COORDINATE LOCATION. GANG TOILET EXHAUST FANS TO OPERATE WITH LIGHTING, PROVIDE 120V AUXILIARY RELAY WATTSTOPPER S120/277 C-P OR EQUAL COORDINATE LOCATIONS OF ALL EQUIPMENT IN ELEVATOR EQUIPMENT ROOM/HOIST ROOM AND PIT WITH ELEVATOR SHOP DRAWINGS PRIOR TO ROUGH-IN. CONNECT EMERGENCY SHUT-DOWN OF ELEVATOR AS REQUIRED. SEQUENCE EQUIPMENT TO SHUT-DOWN THE ELEVATOR BY SMOKE DETECTORS WHEN REQUIRED. ELECTRICAL CONTRACTOR SHALL REFERENCE ELEVATOR SPECIFICATIONS AND COORDINATE ALL REQUIREMENTS WITH ELEVATOR MANUFACTURER FOR ALL ELECTRICAL REQUIREMENTS PRIOR TO ROUGH-IN. COORDINATE QUANTITY & LOCATION OF FIRE SUPPRESSION RISERS AND TAMPER SWITCHES WITH FIRE SUPPRESSION PLANS. VERIFY WITH STATE CODE TO PROVIDE SMOKE DETECTION FOR ELEVATOR, PROVIDE AND INSTALLED BY E.C. CONNECT TO FIRE ALARM SYSTEM UNLESS NOT ALLOWED BY STATE CODE. PROVIDE POWER AND CONTROL TO SIGNAGE, VERIFY EXACT LOCATION WITH ARCHITECTURAL ELEVATIONS AND FINAL CONNECTIONS WITH SIGNAGE SHOP DRAWINGS ELEV. SUMP PUMP, PROVIDE POWER TO CONTROL PANEL. PROVIDED WITH UNIT AND WIRE PER MANUFACTURERS REQUIREMENTS. COORDINATE LOCATION W/PLUMBING PLANS. VERIFY WITH STATE CODE TO PROVIDE SMOKE DETECTION FOR ELEVATOR, PROVIDE AND INSTALLED BY E.C. CONNECT TO FIRE ALARM SYSTEM UNLESS NOT ALLOWED BY STATE CODE. PROVIDE POWER TO MOTORIZED PROJECTION SCREEN AND INSTALL CONTROLS PROVIDED WITH SCREENS AS SHOWN. PROVIDE SINGLE GANG BOX AT 46" A.F.F. FOR RF BLIND CONTROLLER PROVIDED WITH BLINDS. PROVIDE RECEPTACLE AT TOP RIGHT OF EACH SHADE FOR SHADE TO PLUG INTO. COORDINATE EXACT LOCATION WITH SUPPLIER/INSTALLER. REFER TO ARCHITECTURAL MILLWORK DETAILS FOR LOCATION OF ALL OUTLETS LOCATED AT CABINETS. REFER TO ARCHITECTURAL ELEVATIONS FOR MOUNTING HEIGHTS OF OUTLET/TV JACK. PROVIDE POWER TO DOOR OPERATORS, MOTION SENSOR INTEGRAL WITH DOOR. COORDINATE WITH DOOR SUPPLIER INSTALLER PROVIDE 1/2" CONDUIT TO ACCESSIBLE CEILING SPACE AND SINGLE GANG BOX FOR ALL MECHANICAL WALL MOUNTED TEMPERATURE SENSORS, SEE MECHANICAL PLANS FOR LOCATIONS. PROVIDE F.A. CONNECTION FOR LOCAL AUXILIARY SMOKE ALARM CONTACT AND 120V POWER FOR ELEVATOR SMOKE CURTAIN. ALL FOUR SMOKE CURTAINS ARE CONNECTED TO THE SAME EMERGENCY CIRCUIT AS SHOWN. SYSTEM WILL NOT DEPLOY ON GENERAL ALARM. SCREEN REWIND SWITCH DROPS DOWN WITH CURTAIN. PROVIDE 1/2" CONDUIT TO ACCESSIBLE CEILING SPACE AND SINGLE GANG BOX FOR ALL MECHANICAL WALL MOUNTED TEMPERATURE SENSORS, SEE MECHANICAL PLANS FOR LOCATIONS. 1 2 4 5 6 7 8 9 10 15 12 13 14 3 11 16 17 GENERAL POWER NOTES: 1. 2. 3. 4. 5. 6. 7. POWER KEY NOTES: ALL 15A & 20A 120V NON-LOCKING RECEPTACLES WITHIN CHILDCARE AREAS (AGES 7 & UNDER) SHALL BE LISTED TAMPER RESISTANT PER NEC 406.12. THIS INCLUDES GUEST ROOMS. MOUNT PANELS, TRANSFORMERS, DISCONNECT SWITCHES, AND COMBINATION MOTOR STARTERS WITH ADEQUATE CLEARANCES IN ACCORDANCE WITH NEC 110. VOLTAGE DROP TO MEET ASHRAE 90.1 (2007) ELEMENT ROOMS WHERE PANEL IS INDICATED - LABEL PANELS IN EACH ROOM WITH FINAL ROOM NUMBERS, COORDINATE WITH ARCHITECT FOR FINAL ROOM NUMBERING. DENOTED ON PLAN AS BPG (FLOOR #)-XX. "XX" DENOTE ROOM NUMBER INSTALL FIRE ALARM PER MARRIOTT'S MODULE 14 STANDARDS INSTALL PER LATEST NEC CODE: 2008 NEC NOT ALL POWER KEY NOTES ARE USED ON EACH FLOOR. 18 19 20 UP FS TS8 1A-31 1A-31 WR ECH-1 1500W 1A-77 F P 1A- EF-11 P 1A- EF-11 P 1A- EF-11 P 1A-1 EF-11 P 1A-1 EF-11 1A-30 1A-30 1A-30 1C17 1C17 1A-43 1A-43 1C-25 1C-28 1C-54 1C-54 1A-51 38" 1A-62 38" 1A-62 38"1A-64 38" 1A-30 1A-69 1A-231A-30 1A-23 AC 1C-21 AC 1C-21 AC1C-21 J 1C10J1C-8 1C-21 J 1C12 J 1C14 W W 1A-24 1A-25 1A-4 AC 38" 1A-62 1A-62 38" 1A-64 1A-30 1A-781A-69 1A-67 1A-781A-67 14'-3" 14'-6" 18'-0" 18'-0" 14'-3" 18'-0" 18'-0"7'-6"1A-65 1A-79 1A-65 1A-63 1A-79 1A-51 6'-11" 14'-6" 18'-0" 18'-0" 6'-11" 18'-0" 18'-0" 5'-8" DH DH DH DH J 1C-20 1C18 1C16 1C16 1A-30 1C-56 16 CEILING 1C-31 17' - 22' DH 78" F 1C-76/78 FC-17 F 1C-72/74 FC-9 VC S 6 S 6 S 6 S 4 S 4 S 1 1VC S 1 S 2 2 S 2 DH CEILING 1C-82 Engin ngir LLC8200 PEACHTREE AVE. ROCKFORD, MI 49341 P. 616-340-9627 SCALE: 1/4" = 1'-0" 1 EP227 ENLARGED FIRST FLOOR - POWER P:\2018\2018388 Aloft-Element Carmel\Working Drawings\EP227 -Carmel DB.dwg, 5/26/2020 2:53:34 PM, cll09/28/20 CR I F.A.A.1A-39 WR 1A-39 WR 1C-44 1C-37 18" 1C-38 IG 1C-40 IG 1C-47 1C-47 1C-49 1C-49 1C-51 1C-50TV1C15 1C-22 1C-24 1C-54 1A-39 1A-35 1A-35 1C-37 1C-43 1C-44 1C-46 J 1C-20 1C18 1C16 1C16 14 1C-43 14 E300 FOR EQUIPMENT IN BAR. AND STORAGE. 16 16 D DOOR DOOR DH 78" F 1C-47 2'-9"S8 S 7 S 7 S 7 S 7 S 7 S 7 S 7 DH EC SHALL WIRE INTAKE DOORS FOR LAUNDRY CHUTE PER CHUTE MANUFACTURER'S ELECTRICAL INTERLOCK WIRING DIAGRAM. INSTALL AND WIRE MANUAL ON/OFF SWITCH, PROVIDED WITH UNIT IN LAUNDRY ROOM . SMOKE DETECTOR TO BE WIRED TO DOOR INTERLOCK SO THAT INTERLOCKS WILL NOT OPERATE UPON ACTIVATION OF SMOKE DETECTOR, TYPICAL EACH FLOOR. PROVIDE 120V POWER TO INTAKE DOOR AND RUN 4 WIRES BETWEEN FLOORS TO EACH INTAKE DOOR. CONNECT ALL SMOKE DAMPERS TO 120V EMERGENCY CIRCUIT AS SHOWN, COORDINATE VOLTAGE WITH SUPPLIER. CONNECT TO FIRE ALARM SYSTEM. VERIFY QUANTITY AND LOCATIONS WITH MECHANICAL PLANS. PROVIDE TWO-WAY COMMUNICATION SYSTEMS. VIKING E-1600-20A WITH MASTER STATION AT RECEPTION DESK AND CENTRAL CONTROL UNIT IN FIRE COMMAND ROOM CONTROL EF WITH LIGHT SWITCH WEATHERPROOF HORN STROBE TO BE LOCATED ON EXTERIOR OF BUILDING 8'-0" AFF AT FIRE SUPPRESSION CONNECTION, STROBE TO ACTIVATED BY FIRE PROTECTION FLOW SWITCHES. COORDINATE LOCATION. GANG TOILET EXHAUST FANS TO OPERATE WITH LIGHTING, PROVIDE 120V AUXILIARY RELAY WATTSTOPPER S120/277 C-P OR EQUAL COORDINATE LOCATIONS OF ALL EQUIPMENT IN ELEVATOR EQUIPMENT ROOM/HOIST ROOM AND PIT WITH ELEVATOR SHOP DRAWINGS PRIOR TO ROUGH-IN. CONNECT EMERGENCY SHUT-DOWN OF ELEVATOR AS REQUIRED. SEQUENCE EQUIPMENT TO SHUT-DOWN THE ELEVATOR BY SMOKE DETECTORS WHEN REQUIRED. ELECTRICAL CONTRACTOR SHALL REFERENCE ELEVATOR SPECIFICATIONS AND COORDINATE ALL REQUIREMENTS WITH ELEVATOR MANUFACTURER FOR ALL ELECTRICAL REQUIREMENTS PRIOR TO ROUGH-IN. COORDINATE QUANTITY & LOCATION OF FIRE SUPPRESSION RISERS AND TAMPER SWITCHES WITH FIRE SUPPRESSION PLANS. VERIFY WITH STATE CODE TO PROVIDE SMOKE DETECTION FOR ELEVATOR, PROVIDE AND INSTALLED BY E.C. CONNECT TO FIRE ALARM SYSTEM UNLESS NOT ALLOWED BY STATE CODE. PROVIDE POWER AND CONTROL TO SIGNAGE, VERIFY EXACT LOCATION WITH ARCHITECTURAL ELEVATIONS AND FINAL CONNECTIONS WITH SIGNAGE SHOP DRAWINGS ELEV. SUMP PUMP, PROVIDE POWER TO CONTROL PANEL. PROVIDED WITH UNIT AND WIRE PER MANUFACTURERS REQUIREMENTS. COORDINATE LOCATION W/PLUMBING PLANS. VERIFY WITH STATE CODE TO PROVIDE SMOKE DETECTION FOR ELEVATOR, PROVIDE AND INSTALLED BY E.C. CONNECT TO FIRE ALARM SYSTEM UNLESS NOT ALLOWED BY STATE CODE. PROVIDE POWER TO MOTORIZED PROJECTION SCREEN AND INSTALL CONTROLS PROVIDED WITH SCREENS AS SHOWN. PROVIDE SINGLE GANG BOX AT 46" A.F.F. FOR RF BLIND CONTROLLER PROVIDED WITH BLINDS. PROVIDE RECEPTACLE AT TOP RIGHT OF EACH SHADE FOR SHADE TO PLUG INTO. COORDINATE EXACT LOCATION WITH SUPPLIER/INSTALLER. REFER TO ARCHITECTURAL MILLWORK DETAILS FOR LOCATION OF ALL OUTLETS LOCATED AT CABINETS. REFER TO ARCHITECTURAL ELEVATIONS FOR MOUNTING HEIGHTS OF OUTLET/TV JACK. PROVIDE POWER TO DOOR OPERATORS, MOTION SENSOR INTEGRAL WITH DOOR. COORDINATE WITH DOOR SUPPLIER INSTALLER PROVIDE 1/2" CONDUIT TO ACCESSIBLE CEILING SPACE AND SINGLE GANG BOX FOR ALL MECHANICAL WALL MOUNTED TEMPERATURE SENSORS, SEE MECHANICAL PLANS FOR LOCATIONS. PROVIDE F.A. CONNECTION FOR LOCAL AUXILIARY SMOKE ALARM CONTACT AND 120V POWER FOR ELEVATOR SMOKE CURTAIN. ALL FOUR SMOKE CURTAINS ARE CONNECTED TO THE SAME EMERGENCY CIRCUIT AS SHOWN. SYSTEM WILL NOT DEPLOY ON GENERAL ALARM. SCREEN REWIND SWITCH DROPS DOWN WITH CURTAIN. PROVIDE 1/2" CONDUIT TO ACCESSIBLE CEILING SPACE AND SINGLE GANG BOX FOR ALL MECHANICAL WALL MOUNTED TEMPERATURE SENSORS, SEE MECHANICAL PLANS FOR LOCATIONS. 1 2 4 5 6 7 8 9 10 15 12 13 14 3 11 16 17 GENERAL POWER NOTES: 1. 2. 3. 4. 5. 6. 7. POWER KEY NOTES: ALL 15A & 20A 120V NON-LOCKING RECEPTACLES WITHIN CHILDCARE AREAS (AGES 7 & UNDER) SHALL BE LISTED TAMPER RESISTANT PER NEC 406.12. THIS INCLUDES GUEST ROOMS. MOUNT PANELS, TRANSFORMERS, DISCONNECT SWITCHES, AND COMBINATION MOTOR STARTERS WITH ADEQUATE CLEARANCES IN ACCORDANCE WITH NEC 110. VOLTAGE DROP TO MEET ASHRAE 90.1 (2007) ELEMENT ROOMS WHERE PANEL IS INDICATED - LABEL PANELS IN EACH ROOM WITH FINAL ROOM NUMBERS, COORDINATE WITH ARCHITECT FOR FINAL ROOM NUMBERING. DENOTED ON PLAN AS BPG (FLOOR #)-XX. "XX" DENOTE ROOM NUMBER INSTALL FIRE ALARM PER MARRIOTT'S MODULE 14 STANDARDS INSTALL PER LATEST NEC CODE: 2008 NEC NOT ALL POWER KEY NOTES ARE USED ON EACH FLOOR. 18 19 20 1C-47 TV1C15 1C-22 1C-24 1A-6 1A-6 1A-4 1A-4 1A-4 TV 1A-75 1A-6 1A-6 42" 1C-25 1C-25 1B-53 WP WR 1B-53 WR 1A-4 J 1C-20 1C18 1A-642" 1C16 1C16 1A-4 1C-23 REFER TO DRAWING E300 FOR EQUIPMENT IN BAR. AND STORAGE. 1C-56 1C-56 1C-58 1C-61 16 16 16 1C-57 1C-59 1C-56 DH 78" VC S16 S 7 S 7 S 6 S 5 5 DH DH Engin ngir LLC8200 PEACHTREE AVE. ROCKFORD, MI 49341 P. 616-340-9627 SCALE: 1/4" = 1'-0" 1 EP226 ENLARGED FIRST FLOOR - POWER SCALE: 1/4" = 1'-0" 2 EP226 ENLARGED FIRST FLOOR - POWER P:\2018\2018388 Aloft-Element Carmel\Working Drawings\EP226 -Carmel DB.dwg, 5/26/2020 2:51:42 PM, cll09/28/20 24 X 48 24 X 24 24 X 4218 X 4218 X 4218 X 4218 X 4218 X 4224 X 5424 X 2421 X 48 21 X 3621 X 42 21 X 42 21 X 42 21 X 42 21 X 6021 X 60 21 X 60 21 X 60 21 X 4221 X 4221 X 42 21 X 4221 X 42 21 X 4224 X 54 24 X 36BPK2BPK2S F.A.A.1A-39 WR 1A-39 WR 38" 14 1A-37 1A-56 TV 1C-53 60" 60" 1A-56 60" 1A-19 96" 96" 141C-53 1C-54 1A-39 W 1A-31 WR TV 1A-19 96" 38"1A-37 1A-58 1A-58 1A-58 1C17 1A-43 1A-60 1A-60 1C-54 1C-54 38" 1A-62 38" 1A-62 1C-66 1C-54 W 1C17 1A-53 1A-24 1C-54 AC 1A-55 AC 1A-55 AC 1A-55 38" 1A-62 1A-62 1A-65 1A-791A-65 6'-11" 18'-0" 18'-0" DH DH DH J 1C-20 1C18 1C16 1C16 14'-0"26'-6" 18'-0" 16'-6"7"1A-66 1A-66 1A-82 1A-59 16'-0" 18'-0" 8'-11" 1A-82 16 1A-59 DH D D 78" T F 1C17 1C-54 VC VC S8 S 7 S 6 2 3 S 3 S 3 VC 3 DH CEILING 1C-84 EC SHALL WIRE INTAKE DOORS FOR LAUNDRY CHUTE PER CHUTE MANUFACTURER'S ELECTRICAL INTERLOCK WIRING DIAGRAM. INSTALL AND WIRE MANUAL ON/OFF SWITCH, PROVIDED WITH UNIT IN LAUNDRY ROOM . SMOKE DETECTOR TO BE WIRED TO DOOR INTERLOCK SO THAT INTERLOCKS WILL NOT OPERATE UPON ACTIVATION OF SMOKE DETECTOR, TYPICAL EACH FLOOR. PROVIDE 120V POWER TO INTAKE DOOR AND RUN 4 WIRES BETWEEN FLOORS TO EACH INTAKE DOOR. CONNECT ALL SMOKE DAMPERS TO 120V EMERGENCY CIRCUIT AS SHOWN, COORDINATE VOLTAGE WITH SUPPLIER. CONNECT TO FIRE ALARM SYSTEM. VERIFY QUANTITY AND LOCATIONS WITH MECHANICAL PLANS. PROVIDE TWO-WAY COMMUNICATION SYSTEMS. VIKING E-1600-20A WITH MASTER STATION AT RECEPTION DESK AND CENTRAL CONTROL UNIT IN FIRE COMMAND ROOM CONTROL EF WITH LIGHT SWITCH WEATHERPROOF HORN STROBE TO BE LOCATED ON EXTERIOR OF BUILDING 8'-0" AFF AT FIRE SUPPRESSION CONNECTION, STROBE TO ACTIVATED BY FIRE PROTECTION FLOW SWITCHES. COORDINATE LOCATION. GANG TOILET EXHAUST FANS TO OPERATE WITH LIGHTING, PROVIDE 120V AUXILIARY RELAY WATTSTOPPER S120/277 C-P OR EQUAL COORDINATE LOCATIONS OF ALL EQUIPMENT IN ELEVATOR EQUIPMENT ROOM/HOIST ROOM AND PIT WITH ELEVATOR SHOP DRAWINGS PRIOR TO ROUGH-IN. CONNECT EMERGENCY SHUT-DOWN OF ELEVATOR AS REQUIRED. SEQUENCE EQUIPMENT TO SHUT-DOWN THE ELEVATOR BY SMOKE DETECTORS WHEN REQUIRED. ELECTRICAL CONTRACTOR SHALL REFERENCE ELEVATOR SPECIFICATIONS AND COORDINATE ALL REQUIREMENTS WITH ELEVATOR MANUFACTURER FOR ALL ELECTRICAL REQUIREMENTS PRIOR TO ROUGH-IN. COORDINATE QUANTITY & LOCATION OF FIRE SUPPRESSION RISERS AND TAMPER SWITCHES WITH FIRE SUPPRESSION PLANS. VERIFY WITH STATE CODE TO PROVIDE SMOKE DETECTION FOR ELEVATOR, PROVIDE AND INSTALLED BY E.C. CONNECT TO FIRE ALARM SYSTEM UNLESS NOT ALLOWED BY STATE CODE. PROVIDE POWER AND CONTROL TO SIGNAGE, VERIFY EXACT LOCATION WITH ARCHITECTURAL ELEVATIONS AND FINAL CONNECTIONS WITH SIGNAGE SHOP DRAWINGS ELEV. SUMP PUMP, PROVIDE POWER TO CONTROL PANEL. PROVIDED WITH UNIT AND WIRE PER MANUFACTURERS REQUIREMENTS. COORDINATE LOCATION W/PLUMBING PLANS. VERIFY WITH STATE CODE TO PROVIDE SMOKE DETECTION FOR ELEVATOR, PROVIDE AND INSTALLED BY E.C. CONNECT TO FIRE ALARM SYSTEM UNLESS NOT ALLOWED BY STATE CODE. PROVIDE POWER TO MOTORIZED PROJECTION SCREEN AND INSTALL CONTROLS PROVIDED WITH SCREENS AS SHOWN. PROVIDE SINGLE GANG BOX AT 46" A.F.F. FOR RF BLIND CONTROLLER PROVIDED WITH BLINDS. PROVIDE RECEPTACLE AT TOP RIGHT OF EACH SHADE FOR SHADE TO PLUG INTO. COORDINATE EXACT LOCATION WITH SUPPLIER/INSTALLER. REFER TO ARCHITECTURAL MILLWORK DETAILS FOR LOCATION OF ALL OUTLETS LOCATED AT CABINETS. REFER TO ARCHITECTURAL ELEVATIONS FOR MOUNTING HEIGHTS OF OUTLET/TV JACK. PROVIDE POWER TO DOOR OPERATORS, MOTION SENSOR INTEGRAL WITH DOOR. COORDINATE WITH DOOR SUPPLIER INSTALLER PROVIDE 1/2" CONDUIT TO ACCESSIBLE CEILING SPACE AND SINGLE GANG BOX FOR ALL MECHANICAL WALL MOUNTED TEMPERATURE SENSORS, SEE MECHANICAL PLANS FOR LOCATIONS. PROVIDE F.A. CONNECTION FOR LOCAL AUXILIARY SMOKE ALARM CONTACT AND 120V POWER FOR ELEVATOR SMOKE CURTAIN. ALL FOUR SMOKE CURTAINS ARE CONNECTED TO THE SAME EMERGENCY CIRCUIT AS SHOWN. SYSTEM WILL NOT DEPLOY ON GENERAL ALARM. SCREEN REWIND SWITCH DROPS DOWN WITH CURTAIN. PROVIDE 1/2" CONDUIT TO ACCESSIBLE CEILING SPACE AND SINGLE GANG BOX FOR ALL MECHANICAL WALL MOUNTED TEMPERATURE SENSORS, SEE MECHANICAL PLANS FOR LOCATIONS. 1 2 4 5 6 7 8 9 10 15 12 13 14 3 11 16 17 GENERAL POWER NOTES: 1. 2. 3. 4. 5. 6. 7. POWER KEY NOTES: ALL 15A & 20A 120V NON-LOCKING RECEPTACLES WITHIN CHILDCARE AREAS (AGES 7 & UNDER) SHALL BE LISTED TAMPER RESISTANT PER NEC 406.12. THIS INCLUDES GUEST ROOMS. MOUNT PANELS, TRANSFORMERS, DISCONNECT SWITCHES, AND COMBINATION MOTOR STARTERS WITH ADEQUATE CLEARANCES IN ACCORDANCE WITH NEC 110. VOLTAGE DROP TO MEET ASHRAE 90.1 (2007) ELEMENT ROOMS WHERE PANEL IS INDICATED - LABEL PANELS IN EACH ROOM WITH FINAL ROOM NUMBERS, COORDINATE WITH ARCHITECT FOR FINAL ROOM NUMBERING. DENOTED ON PLAN AS BPG (FLOOR #)-XX. "XX" DENOTE ROOM NUMBER INSTALL FIRE ALARM PER MARRIOTT'S MODULE 14 STANDARDS INSTALL PER LATEST NEC CODE: 2008 NEC NOT ALL POWER KEY NOTES ARE USED ON EACH FLOOR. 18 19 20 Engin ngir LLC8200 PEACHTREE AVE. ROCKFORD, MI 49341 P. 616-340-9627 SCALE: 1/4" = 1'-0" 1 EP225 ENLARGED FIRST FLOOR - POWER REFER TO SHEET E300 FOR WORK IN THIS AREA P:\2018\2018388 Aloft-Element Carmel\Working Drawings\EP225 -Carmel DB.dwg, 5/26/2020 2:49:08 PM, cll09/28/20 SDP1 300 KVAF T-LS130 KVABPLS1RELAYPNL 1DP1BP-1A F JOCKEY PUMP RE: E6.0 1B-11 5 F FIRE PUMP RE: E6.0 MDPATS-1 NEMA 3R AST-2 NEMA 3R ATS-3BP-1B BP-1CBPP EF-10 P 25 P DUCT HEATERRE: E600WP-1 T-JBDP1 3P90A 20KW COF.A.C.P. W FIRE ALARM PANEL, BOOSTER PANEL AND FIRE PHONE PANEL EMI-12 1B-11 WR 1B-11 WR F 1B-9 1B-9 1B-9 DH 1C-55 W W CR W 1B-31 TV 1B-33 TV 1B-35 TV 1B-23 TV 1B-25 TV 1B-27 TV 1B-29 TV 1B-7 TV 1B-19 TV 1B-21 TVTV1B-37 1B-37 1B-23 1B-37 W CR CR PDU-1RE: E60040" P-6 P-3 208V 40" P-8 40" P-1 40"40" P-13 40" P-10 40" P-1 40" P-2 40" P-4 40" P-15 40" P-11 P 1B-1 EF-8 P 1B-15 EF-11 P 1B-15 EF-11 P P-13 EF-5 1C-5 1C-5 1C-5 P EM1-24 EF-13 P 1C-7 EF-4 P-19 WP 1B-18 J P-23 J 1C-32 J 1C-34 AC1C-36 AC1C-36 J 1C-27 AC J 1C-29 AC 2P20A P-15 P-15 P-15 P-19 P-19 P-19 P-21 P-21 P-27 VC WP WP WP K 1C-55 1C-60 1C-60 1B-18 WR WR WR 1B-18 P-20 GFI BREAKER 1B-731B-771B-561B-741B-7616 W IC-71/73 FC-6 HAND DRYERSHAND DRYERS D D D D D TTIC-5 IB-3 IB-5TWP-135 T 1C-42 D F 1B-54 EF-7 THAND DRYER WR WR WR WR WR WR WR WR WR WR BPG-2 BPG-2 BPG-2 BPG-2 F 1B-17 1B-171B-751B-791B-811B-821B-58GFI BREAKER 1C-36 S S VC VC S 15 15 15 S 16 14 14 S 14 S 14 S 13 S 13 S 14 1C-36 EC SHALL WIRE INTAKE DOORS FOR LAUNDRY CHUTE PER CHUTE MANUFACTURER'S ELECTRICAL INTERLOCK WIRING DIAGRAM. INSTALL AND WIRE MANUAL ON/OFF SWITCH, PROVIDED WITH UNIT IN LAUNDRY ROOM . SMOKE DETECTOR TO BE WIRED TO DOOR INTERLOCK SO THAT INTERLOCKS WILL NOT OPERATE UPON ACTIVATION OF SMOKE DETECTOR, TYPICAL EACH FLOOR. PROVIDE 120V POWER TO INTAKE DOOR AND RUN 4 WIRES BETWEEN FLOORS TO EACH INTAKE DOOR. CONNECT ALL SMOKE DAMPERS TO 120V EMERGENCY CIRCUIT AS SHOWN, COORDINATE VOLTAGE WITH SUPPLIER. CONNECT TO FIRE ALARM SYSTEM. VERIFY QUANTITY AND LOCATIONS WITH MECHANICAL PLANS. PROVIDE TWO-WAY COMMUNICATION SYSTEMS. VIKING E-1600-20A WITH MASTER STATION AT RECEPTION DESK AND CENTRAL CONTROL UNIT IN FIRE COMMAND ROOM CONTROL EF WITH LIGHT SWITCH WEATHERPROOF HORN STROBE TO BE LOCATED ON EXTERIOR OF BUILDING 8'-0" AFF AT FIRE SUPPRESSION CONNECTION, STROBE TO ACTIVATED BY FIRE PROTECTION FLOW SWITCHES. COORDINATE LOCATION. GANG TOILET EXHAUST FANS TO OPERATE WITH LIGHTING, PROVIDE 120V AUXILIARY RELAY WATTSTOPPER S120/277 C-P OR EQUAL COORDINATE LOCATIONS OF ALL EQUIPMENT IN ELEVATOR EQUIPMENT ROOM/HOIST ROOM AND PIT WITH ELEVATOR SHOP DRAWINGS PRIOR TO ROUGH-IN. CONNECT EMERGENCY SHUT-DOWN OF ELEVATOR AS REQUIRED. SEQUENCE EQUIPMENT TO SHUT-DOWN THE ELEVATOR BY SMOKE DETECTORS WHEN REQUIRED. ELECTRICAL CONTRACTOR SHALL REFERENCE ELEVATOR SPECIFICATIONS AND COORDINATE ALL REQUIREMENTS WITH ELEVATOR MANUFACTURER FOR ALL ELECTRICAL REQUIREMENTS PRIOR TO ROUGH-IN. COORDINATE QUANTITY & LOCATION OF FIRE SUPPRESSION RISERS AND TAMPER SWITCHES WITH FIRE SUPPRESSION PLANS. VERIFY WITH STATE CODE TO PROVIDE SMOKE DETECTION FOR ELEVATOR, PROVIDE AND INSTALLED BY E.C. CONNECT TO FIRE ALARM SYSTEM UNLESS NOT ALLOWED BY STATE CODE. PROVIDE POWER AND CONTROL TO SIGNAGE, VERIFY EXACT LOCATION WITH ARCHITECTURAL ELEVATIONS AND FINAL CONNECTIONS WITH SIGNAGE SHOP DRAWINGS ELEV. SUMP PUMP, PROVIDE POWER TO CONTROL PANEL. PROVIDED WITH UNIT AND WIRE PER MANUFACTURERS REQUIREMENTS. COORDINATE LOCATION W/PLUMBING PLANS. VERIFY WITH STATE CODE TO PROVIDE SMOKE DETECTION FOR ELEVATOR, PROVIDE AND INSTALLED BY E.C. CONNECT TO FIRE ALARM SYSTEM UNLESS NOT ALLOWED BY STATE CODE. PROVIDE POWER TO MOTORIZED PROJECTION SCREEN AND INSTALL CONTROLS PROVIDED WITH SCREENS AS SHOWN. PROVIDE SINGLE GANG BOX AT 46" A.F.F. FOR RF BLIND CONTROLLER PROVIDED WITH BLINDS. PROVIDE RECEPTACLE AT TOP RIGHT OF EACH SHADE FOR SHADE TO PLUG INTO. COORDINATE EXACT LOCATION WITH SUPPLIER/INSTALLER. REFER TO ARCHITECTURAL MILLWORK DETAILS FOR LOCATION OF ALL OUTLETS LOCATED AT CABINETS. REFER TO ARCHITECTURAL ELEVATIONS FOR MOUNTING HEIGHTS OF OUTLET/TV JACK. PROVIDE POWER TO DOOR OPERATORS, MOTION SENSOR INTEGRAL WITH DOOR. COORDINATE WITH DOOR SUPPLIER INSTALLER PROVIDE 1/2" CONDUIT TO ACCESSIBLE CEILING SPACE AND SINGLE GANG BOX FOR ALL MECHANICAL WALL MOUNTED TEMPERATURE SENSORS, SEE MECHANICAL PLANS FOR LOCATIONS. PROVIDE F.A. CONNECTION FOR LOCAL AUXILIARY SMOKE ALARM CONTACT AND 120V POWER FOR ELEVATOR SMOKE CURTAIN. ALL FOUR SMOKE CURTAINS ARE CONNECTED TO THE SAME EMERGENCY CIRCUIT AS SHOWN. SYSTEM WILL NOT DEPLOY ON GENERAL ALARM. SCREEN REWIND SWITCH DROPS DOWN WITH CURTAIN. PROVIDE 1/2" CONDUIT TO ACCESSIBLE CEILING SPACE AND SINGLE GANG BOX FOR ALL MECHANICAL WALL MOUNTED TEMPERATURE SENSORS, SEE MECHANICAL PLANS FOR LOCATIONS. 1 2 4 5 6 7 8 9 10 15 12 13 14 3 11 16 17 GENERAL POWER NOTES: 1. 2. 3. 4. 5. 6. 7. POWER KEY NOTES: ALL 15A & 20A 120V NON-LOCKING RECEPTACLES WITHIN CHILDCARE AREAS (AGES 7 & UNDER) SHALL BE LISTED TAMPER RESISTANT PER NEC 406.12. THIS INCLUDES GUEST ROOMS. MOUNT PANELS, TRANSFORMERS, DISCONNECT SWITCHES, AND COMBINATION MOTOR STARTERS WITH ADEQUATE CLEARANCES IN ACCORDANCE WITH NEC 110. VOLTAGE DROP TO MEET ASHRAE 90.1 (2007) ELEMENT ROOMS WHERE PANEL IS INDICATED - LABEL PANELS IN EACH ROOM WITH FINAL ROOM NUMBERS, COORDINATE WITH ARCHITECT FOR FINAL ROOM NUMBERING. DENOTED ON PLAN AS BPG (FLOOR #)-XX. "XX" DENOTE ROOM NUMBER INSTALL FIRE ALARM PER MARRIOTT'S MODULE 14 STANDARDS INSTALL PER LATEST NEC CODE: 2008 NEC NOT ALL POWER KEY NOTES ARE USED ON EACH FLOOR. 18 19 20 Engin ngir LLC8200 PEACHTREE AVE. ROCKFORD, MI 49341 P. 616-340-9627 SCALE: 1/4" = 1'-0" 1 EP224 ENLARGED FIRST FLOOR - POWER NOTE: ELEMENT GUEST SUITES POWER AND LIGHTING CIRCUIT SHOWN ON E612, PANEL BG-2 FOR THIS FLOOR.P:\2018\2018388 Aloft-Element Carmel\Working Drawings\EP224 -Carmel DB.dwg, 5/26/2020 2:47:00 PM, cll09/28/20 24 X 48 24 X 42 24 X 36 24 X 36 24 X 36 24 X 3624 X 4824 X 4224 X 54 F JOCKEY PUMP RE: E6.0 F FIRE PUMP RE: E6.0 BPK11B-9 DH DH 1C-55 1B-23 TV 1B-25 TV 1B-27 TV 1B-29 TV TV1B-37 1B-23 1B-37 TV1A- 65" 65" 1B-53 1B-4 CR I 1B-2 1B-2 W 1B-10 1A-81B-10 1B-6 1B-6 1B-12 1B-12 P 1B-15 EF-11 P 1B-15 EF-11 1B-10 1B-1B-14 1B-22 1B-51 1B-22 1B-14 1B-20 1B-20 1B-53 J 1C-32 J 1C-34 AC1C-36 AC1C-36 J 1C-27 AC J 1C-29 AC 1C-331C-33 1B-11 WR 1B-10 28" 1B-53 1B-20 1B-53 1B-4 1B-4 WR 1B-59 1B-57 1B-57 1C-55 1C-60 1C-60 D DOOR DOOR HAND DRYERSHAND DRYERS EM REFER TO DRWING E301 FOR POWER IN THIS AREA 16'-7"4'-8" 9'-6" 21'-11"8'-3"14'-3"3'-2"BPK1SBPG-2 BPG-2 1B-17 1C-36 S 13 S 13 S 12 S 12 S 12 S 12 S 12 S 12 S 12 S11 JJ 1C-36 EC SHALL WIRE INTAKE DOORS FOR LAUNDRY CHUTE PER CHUTE MANUFACTURER'S ELECTRICAL INTERLOCK WIRING DIAGRAM. INSTALL AND WIRE MANUAL ON/OFF SWITCH, PROVIDED WITH UNIT IN LAUNDRY ROOM . SMOKE DETECTOR TO BE WIRED TO DOOR INTERLOCK SO THAT INTERLOCKS WILL NOT OPERATE UPON ACTIVATION OF SMOKE DETECTOR, TYPICAL EACH FLOOR. PROVIDE 120V POWER TO INTAKE DOOR AND RUN 4 WIRES BETWEEN FLOORS TO EACH INTAKE DOOR. CONNECT ALL SMOKE DAMPERS TO 120V EMERGENCY CIRCUIT AS SHOWN, COORDINATE VOLTAGE WITH SUPPLIER. CONNECT TO FIRE ALARM SYSTEM. VERIFY QUANTITY AND LOCATIONS WITH MECHANICAL PLANS. PROVIDE TWO-WAY COMMUNICATION SYSTEMS. VIKING E-1600-20A WITH MASTER STATION AT RECEPTION DESK AND CENTRAL CONTROL UNIT IN FIRE COMMAND ROOM CONTROL EF WITH LIGHT SWITCH WEATHERPROOF HORN STROBE TO BE LOCATED ON EXTERIOR OF BUILDING 8'-0" AFF AT FIRE SUPPRESSION CONNECTION, STROBE TO ACTIVATED BY FIRE PROTECTION FLOW SWITCHES. COORDINATE LOCATION. GANG TOILET EXHAUST FANS TO OPERATE WITH LIGHTING, PROVIDE 120V AUXILIARY RELAY WATTSTOPPER S120/277 C-P OR EQUAL COORDINATE LOCATIONS OF ALL EQUIPMENT IN ELEVATOR EQUIPMENT ROOM/HOIST ROOM AND PIT WITH ELEVATOR SHOP DRAWINGS PRIOR TO ROUGH-IN. CONNECT EMERGENCY SHUT-DOWN OF ELEVATOR AS REQUIRED. SEQUENCE EQUIPMENT TO SHUT-DOWN THE ELEVATOR BY SMOKE DETECTORS WHEN REQUIRED. ELECTRICAL CONTRACTOR SHALL REFERENCE ELEVATOR SPECIFICATIONS AND COORDINATE ALL REQUIREMENTS WITH ELEVATOR MANUFACTURER FOR ALL ELECTRICAL REQUIREMENTS PRIOR TO ROUGH-IN. COORDINATE QUANTITY & LOCATION OF FIRE SUPPRESSION RISERS AND TAMPER SWITCHES WITH FIRE SUPPRESSION PLANS. VERIFY WITH STATE CODE TO PROVIDE SMOKE DETECTION FOR ELEVATOR, PROVIDE AND INSTALLED BY E.C. CONNECT TO FIRE ALARM SYSTEM UNLESS NOT ALLOWED BY STATE CODE. PROVIDE POWER AND CONTROL TO SIGNAGE, VERIFY EXACT LOCATION WITH ARCHITECTURAL ELEVATIONS AND FINAL CONNECTIONS WITH SIGNAGE SHOP DRAWINGS ELEV. SUMP PUMP, PROVIDE POWER TO CONTROL PANEL. PROVIDED WITH UNIT AND WIRE PER MANUFACTURERS REQUIREMENTS. COORDINATE LOCATION W/PLUMBING PLANS. VERIFY WITH STATE CODE TO PROVIDE SMOKE DETECTION FOR ELEVATOR, PROVIDE AND INSTALLED BY E.C. CONNECT TO FIRE ALARM SYSTEM UNLESS NOT ALLOWED BY STATE CODE. PROVIDE POWER TO MOTORIZED PROJECTION SCREEN AND INSTALL CONTROLS PROVIDED WITH SCREENS AS SHOWN. PROVIDE SINGLE GANG BOX AT 46" A.F.F. FOR RF BLIND CONTROLLER PROVIDED WITH BLINDS. PROVIDE RECEPTACLE AT TOP RIGHT OF EACH SHADE FOR SHADE TO PLUG INTO. COORDINATE EXACT LOCATION WITH SUPPLIER/INSTALLER. REFER TO ARCHITECTURAL MILLWORK DETAILS FOR LOCATION OF ALL OUTLETS LOCATED AT CABINETS. REFER TO ARCHITECTURAL ELEVATIONS FOR MOUNTING HEIGHTS OF OUTLET/TV JACK. PROVIDE POWER TO DOOR OPERATORS, MOTION SENSOR INTEGRAL WITH DOOR. COORDINATE WITH DOOR SUPPLIER INSTALLER PROVIDE 1/2" CONDUIT TO ACCESSIBLE CEILING SPACE AND SINGLE GANG BOX FOR ALL MECHANICAL WALL MOUNTED TEMPERATURE SENSORS, SEE MECHANICAL PLANS FOR LOCATIONS. PROVIDE F.A. CONNECTION FOR LOCAL AUXILIARY SMOKE ALARM CONTACT AND 120V POWER FOR ELEVATOR SMOKE CURTAIN. ALL FOUR SMOKE CURTAINS ARE CONNECTED TO THE SAME EMERGENCY CIRCUIT AS SHOWN. SYSTEM WILL NOT DEPLOY ON GENERAL ALARM. SCREEN REWIND SWITCH DROPS DOWN WITH CURTAIN. PROVIDE 1/2" CONDUIT TO ACCESSIBLE CEILING SPACE AND SINGLE GANG BOX FOR ALL MECHANICAL WALL MOUNTED TEMPERATURE SENSORS, SEE MECHANICAL PLANS FOR LOCATIONS. 1 2 4 5 6 7 8 9 10 15 12 13 14 3 11 16 17 GENERAL POWER NOTES: 1. 2. 3. 4. 5. 6. 7. POWER KEY NOTES: ALL 15A & 20A 120V NON-LOCKING RECEPTACLES WITHIN CHILDCARE AREAS (AGES 7 & UNDER) SHALL BE LISTED TAMPER RESISTANT PER NEC 406.12. THIS INCLUDES GUEST ROOMS. MOUNT PANELS, TRANSFORMERS, DISCONNECT SWITCHES, AND COMBINATION MOTOR STARTERS WITH ADEQUATE CLEARANCES IN ACCORDANCE WITH NEC 110. VOLTAGE DROP TO MEET ASHRAE 90.1 (2007) ELEMENT ROOMS WHERE PANEL IS INDICATED - LABEL PANELS IN EACH ROOM WITH FINAL ROOM NUMBERS, COORDINATE WITH ARCHITECT FOR FINAL ROOM NUMBERING. DENOTED ON PLAN AS BPG (FLOOR #)-XX. "XX" DENOTE ROOM NUMBER INSTALL FIRE ALARM PER MARRIOTT'S MODULE 14 STANDARDS INSTALL PER LATEST NEC CODE: 2008 NEC NOT ALL POWER KEY NOTES ARE USED ON EACH FLOOR. 18 19 20 Engin ngir LLC8200 PEACHTREE AVE. ROCKFORD, MI 49341 P. 616-340-9627 SCALE: 1/4" = 1'-0" 1 EP223 ENLARGED FIRST FLOOR - POWER NOTE: ELEMENT GUEST SUITES POWER AND LIGHTING CIRCUIT SHOWN ON E612, PANEL BG-2 FOR THIS FLOOR.P:\2018\2018388 Aloft-Element Carmel\Working Drawings\EP223 -Carmel DB.dwg, 5/26/2020 2:41:37 PM, cll09/28/20 14 X 4214 X 42 STUB (4) 4" C BETWEEN ALL FLOORS RE: 1/ET2.00 1A-13 1A-11 CR 1C-24 1B-16 1B-16 W CR 1A-131A-83 1A-15 1A-15 W L6-30R PROVIDE 4"X6" GROUND BAR, #8 AWG WIRE EM1-1 1A-63 1A-69 1A-50 1A-52 1A-54 ACACAC 1B-53 P-19 WP WP WP WR 1B-53 WR 1B-18 P-15 W 1C-26 PROVIDE POWER TO EXTERIOR BARBEQUES. PROVIDE ON/OFF SWITCH AT RECEPTION DESK. SHUT GAS SOLENOID OFF IN THE EVENT OF FIRE AND PROVIDE REMOTE SHUT-DOWN RED MUSHROOM BUTTON WITH WEATHERPROOF ENCLOSURE AT 46" TO CENTER. K 1A-6 1A-4 1B-66 WP 1B-70 WP MOUNT @ 72" FOR STRING OF LIGHTS MOUNT @ 72" FOR STRING OF LIGHTSMOUNT @ 72" FOR STRING OF LIGHTS 1A-49 1C-331C-33 REFER TO DRAWING E300 FOR EQUIPMENT IN BAR. AND STORAGE. MOUNT @ 72" FOR STRING OF LIGHTS TYPE 403MOUNT @ 72" FOR STRING OF LIGHTS TYPE TE-403 1B-18 WR WR WR 1B-18 1A-15 1B-731B-771B-561B-741B-761C-61 TYPE TE-403 STRING OF LIGHTS TYPICAL TYPE TE-403 STRING OF LIGHTS TYPICAL W MOUNT HOUSE PHONE ROUGH-IN AT 48"AFF. CONDUIT WILL BE EXPOSED ON WOOD, PROVIDE WP WIREMOLD . EMT NOT APPROVED. 1C-56 D D WP-135 F 1B-54 EF-7 1B-75 WR WR 1B-17 1B-751B-791B-811B-821B-58S 16 S 16S16 S 16 S 7 EC SHALL WIRE INTAKE DOORS FOR LAUNDRY CHUTE PER CHUTE MANUFACTURER'S ELECTRICAL INTERLOCK WIRING DIAGRAM. INSTALL AND WIRE MANUAL ON/OFF SWITCH, PROVIDED WITH UNIT IN LAUNDRY ROOM . SMOKE DETECTOR TO BE WIRED TO DOOR INTERLOCK SO THAT INTERLOCKS WILL NOT OPERATE UPON ACTIVATION OF SMOKE DETECTOR, TYPICAL EACH FLOOR. PROVIDE 120V POWER TO INTAKE DOOR AND RUN 4 WIRES BETWEEN FLOORS TO EACH INTAKE DOOR. CONNECT ALL SMOKE DAMPERS TO 120V EMERGENCY CIRCUIT AS SHOWN, COORDINATE VOLTAGE WITH SUPPLIER. CONNECT TO FIRE ALARM SYSTEM. VERIFY QUANTITY AND LOCATIONS WITH MECHANICAL PLANS. PROVIDE TWO-WAY COMMUNICATION SYSTEMS. VIKING E-1600-20A WITH MASTER STATION AT RECEPTION DESK AND CENTRAL CONTROL UNIT IN FIRE COMMAND ROOM CONTROL EF WITH LIGHT SWITCH WEATHERPROOF HORN STROBE TO BE LOCATED ON EXTERIOR OF BUILDING 8'-0" AFF AT FIRE SUPPRESSION CONNECTION, STROBE TO ACTIVATED BY FIRE PROTECTION FLOW SWITCHES. COORDINATE LOCATION. GANG TOILET EXHAUST FANS TO OPERATE WITH LIGHTING, PROVIDE 120V AUXILIARY RELAY WATTSTOPPER S120/277 C-P OR EQUAL COORDINATE LOCATIONS OF ALL EQUIPMENT IN ELEVATOR EQUIPMENT ROOM/HOIST ROOM AND PIT WITH ELEVATOR SHOP DRAWINGS PRIOR TO ROUGH-IN. CONNECT EMERGENCY SHUT-DOWN OF ELEVATOR AS REQUIRED. SEQUENCE EQUIPMENT TO SHUT-DOWN THE ELEVATOR BY SMOKE DETECTORS WHEN REQUIRED. ELECTRICAL CONTRACTOR SHALL REFERENCE ELEVATOR SPECIFICATIONS AND COORDINATE ALL REQUIREMENTS WITH ELEVATOR MANUFACTURER FOR ALL ELECTRICAL REQUIREMENTS PRIOR TO ROUGH-IN. COORDINATE QUANTITY & LOCATION OF FIRE SUPPRESSION RISERS AND TAMPER SWITCHES WITH FIRE SUPPRESSION PLANS. VERIFY WITH STATE CODE TO PROVIDE SMOKE DETECTION FOR ELEVATOR, PROVIDE AND INSTALLED BY E.C. CONNECT TO FIRE ALARM SYSTEM UNLESS NOT ALLOWED BY STATE CODE. PROVIDE POWER AND CONTROL TO SIGNAGE, VERIFY EXACT LOCATION WITH ARCHITECTURAL ELEVATIONS AND FINAL CONNECTIONS WITH SIGNAGE SHOP DRAWINGS ELEV. SUMP PUMP, PROVIDE POWER TO CONTROL PANEL. PROVIDED WITH UNIT AND WIRE PER MANUFACTURERS REQUIREMENTS. COORDINATE LOCATION W/PLUMBING PLANS. VERIFY WITH STATE CODE TO PROVIDE SMOKE DETECTION FOR ELEVATOR, PROVIDE AND INSTALLED BY E.C. CONNECT TO FIRE ALARM SYSTEM UNLESS NOT ALLOWED BY STATE CODE. PROVIDE POWER TO MOTORIZED PROJECTION SCREEN AND INSTALL CONTROLS PROVIDED WITH SCREENS AS SHOWN. PROVIDE SINGLE GANG BOX AT 46" A.F.F. FOR RF BLIND CONTROLLER PROVIDED WITH BLINDS. PROVIDE RECEPTACLE AT TOP RIGHT OF EACH SHADE FOR SHADE TO PLUG INTO. COORDINATE EXACT LOCATION WITH SUPPLIER/INSTALLER. REFER TO ARCHITECTURAL MILLWORK DETAILS FOR LOCATION OF ALL OUTLETS LOCATED AT CABINETS. REFER TO ARCHITECTURAL ELEVATIONS FOR MOUNTING HEIGHTS OF OUTLET/TV JACK. PROVIDE POWER TO DOOR OPERATORS, MOTION SENSOR INTEGRAL WITH DOOR. COORDINATE WITH DOOR SUPPLIER INSTALLER PROVIDE 1/2" CONDUIT TO ACCESSIBLE CEILING SPACE AND SINGLE GANG BOX FOR ALL MECHANICAL WALL MOUNTED TEMPERATURE SENSORS, SEE MECHANICAL PLANS FOR LOCATIONS. PROVIDE F.A. CONNECTION FOR LOCAL AUXILIARY SMOKE ALARM CONTACT AND 120V POWER FOR ELEVATOR SMOKE CURTAIN. ALL FOUR SMOKE CURTAINS ARE CONNECTED TO THE SAME EMERGENCY CIRCUIT AS SHOWN. SYSTEM WILL NOT DEPLOY ON GENERAL ALARM. SCREEN REWIND SWITCH DROPS DOWN WITH CURTAIN. PROVIDE 1/2" CONDUIT TO ACCESSIBLE CEILING SPACE AND SINGLE GANG BOX FOR ALL MECHANICAL WALL MOUNTED TEMPERATURE SENSORS, SEE MECHANICAL PLANS FOR LOCATIONS. 1 2 4 5 6 7 8 9 10 15 12 13 14 3 11 16 17 GENERAL POWER NOTES: 1. 2. 3. 4. 5. 6. 7. POWER KEY NOTES: ALL 15A & 20A 120V NON-LOCKING RECEPTACLES WITHIN CHILDCARE AREAS (AGES 7 & UNDER) SHALL BE LISTED TAMPER RESISTANT PER NEC 406.12. THIS INCLUDES GUEST ROOMS. MOUNT PANELS, TRANSFORMERS, DISCONNECT SWITCHES, AND COMBINATION MOTOR STARTERS WITH ADEQUATE CLEARANCES IN ACCORDANCE WITH NEC 110. VOLTAGE DROP TO MEET ASHRAE 90.1 (2007) ELEMENT ROOMS WHERE PANEL IS INDICATED - LABEL PANELS IN EACH ROOM WITH FINAL ROOM NUMBERS, COORDINATE WITH ARCHITECT FOR FINAL ROOM NUMBERING. DENOTED ON PLAN AS BPG (FLOOR #)-XX. "XX" DENOTE ROOM NUMBER INSTALL FIRE ALARM PER MARRIOTT'S MODULE 14 STANDARDS INSTALL PER LATEST NEC CODE: 2008 NEC NOT ALL POWER KEY NOTES ARE USED ON EACH FLOOR. 18 19 20 Engin ngir LLC8200 PEACHTREE AVE. ROCKFORD, MI 49341 P. 616-340-9627 SCALE: 1/4" = 1'-0" 1 EP222 ENLARGED FIRST FLOOR - POWER P:\2018\2018388 Aloft-Element Carmel\Working Drawings\EP222 -Carmel DB.dwg, 5/26/2020 2:38:29 PM, cll09/28/20 22 X 3914 X 4214 X 42 STUB (4) 4" C BETWEEN ALL FLOORS RE: 1/ET2.00 GENERATOR ANNUCIATOR PANEL TWO WAY COMMUNICATION MASTER STATION F.A.A. 1B-13 1A-38 AC 1A-48 AC 1A-26 1A-36 1A-36 1B-13 1B-71 1A-47 1 1C-39 1B-47 DRYERS RE: ONELINE/ E6.0 MD MDMD 40" 1A-29 INTERLOCK W/ DRYER WASHER RE: ONELINE/ E6.0 1A-14 48" DISP.LOCATION 48" W T 1A-40 EM1-2 SP-1 1.5HP 3P15A EM1-38/40/42 11F 11F SP-1 1.5HP 3P15A EM1-13/15/17 11 F EM1-10 EM1-2 EM1-10 EM1-2 W P 1A-1 EF-5 1A-7 1A-7 1A-10 1A-21 GFI BRKR AC 1A-46 AC 1A-2 P 1A-8 EF-9 WEM1-22 46" TIMECLOCK 1A-13 1A-11 CR 1A-67 14 1C-37 18" 18" 1C-45 1A-9 1C-38 IG 1C-40 IG CR 1C-351C-35 18" 1C-37 6A15 J SIGNAGE CR CR 1B-16 1B-16 W AC 1B-20 CO MD 1A-13 1A-91A-65 AC 1A-44 AC 1A-5 1A-7 1A-7 1A-7 72" 72" 1C-37 1A-83 1A-17 1B-8 1B-8 1B-28 1A-11 1A-10 1A-10 1A-15 1A-15 W L6-30R 3/4" FIRE RATED PLY WOOD. HORIZONTAL MOUNTED CENTER ON WALL. PAINT TO MATCH COLOR OF ROOM. LEAVE FIRE SYMBOL SHOWING. PROVIDE 4"X6" GROUND BAR, #8 AWG WIRE 1A-47 1A-47 EM1-5 EM1-1 1A-63 1A-69 1B-72 1B-32 1A-50 1A-52 1A-54 ACACAC 1B-26 1B-24 AC1A-34 1C-30 1C-33 1C-37 1A-10 AC 1C-28 1C-26 1B-24 1C-44 1C-481C-48 1C-46 1B-57 F.A.A.1A-49 1C-331C-33 1A27 1A27 1A27 14 REFER TO DRAWING E300 FOR EQUIPMENT IN BAR. AND STORAGE. TV 60" 60" 60" 1B-13 1C-41 1B-24 1A-15 1A-12 1A-40 1B-731B-771B-561B-741B-761A-29 P 1B-36 EF-7 F 1C-63/65 FC-4 F 1C-67/69 FC-8 F 1C-71/73 FC-6 1C-42 D 1C-42 D F 1B-54 EF-7 TDRYERS RE: ONELINE/ E6.0 DRYERS RE: ONELINE/ E6.0 DRYERS RE: ONELINE/ E6.0 4 1A-61 T F 1B-171B-751B-791B-811B-821B-587'-1"2'-9"SP-1 1.5HP 3P15A EM1-14/16/18 L6-30R EM1-7 VC VC VC VC VC VC VC S 12 12 13 16 12 VC 9 S 10 10 S 9S 9 S11 EC SHALL WIRE INTAKE DOORS FOR LAUNDRY CHUTE PER CHUTE MANUFACTURER'S ELECTRICAL INTERLOCK WIRING DIAGRAM. INSTALL AND WIRE MANUAL ON/OFF SWITCH, PROVIDED WITH UNIT IN LAUNDRY ROOM . SMOKE DETECTOR TO BE WIRED TO DOOR INTERLOCK SO THAT INTERLOCKS WILL NOT OPERATE UPON ACTIVATION OF SMOKE DETECTOR, TYPICAL EACH FLOOR. PROVIDE 120V POWER TO INTAKE DOOR AND RUN 4 WIRES BETWEEN FLOORS TO EACH INTAKE DOOR. CONNECT ALL SMOKE DAMPERS TO 120V EMERGENCY CIRCUIT AS SHOWN, COORDINATE VOLTAGE WITH SUPPLIER. CONNECT TO FIRE ALARM SYSTEM. VERIFY QUANTITY AND LOCATIONS WITH MECHANICAL PLANS. PROVIDE TWO-WAY COMMUNICATION SYSTEMS. VIKING E-1600-20A WITH MASTER STATION AT RECEPTION DESK AND CENTRAL CONTROL UNIT IN FIRE COMMAND ROOM CONTROL EF WITH LIGHT SWITCH WEATHERPROOF HORN STROBE TO BE LOCATED ON EXTERIOR OF BUILDING 8'-0" AFF AT FIRE SUPPRESSION CONNECTION, STROBE TO ACTIVATED BY FIRE PROTECTION FLOW SWITCHES. COORDINATE LOCATION. GANG TOILET EXHAUST FANS TO OPERATE WITH LIGHTING, PROVIDE 120V AUXILIARY RELAY WATTSTOPPER S120/277 C-P OR EQUAL COORDINATE LOCATIONS OF ALL EQUIPMENT IN ELEVATOR EQUIPMENT ROOM/HOIST ROOM AND PIT WITH ELEVATOR SHOP DRAWINGS PRIOR TO ROUGH-IN. CONNECT EMERGENCY SHUT-DOWN OF ELEVATOR AS REQUIRED. SEQUENCE EQUIPMENT TO SHUT-DOWN THE ELEVATOR BY SMOKE DETECTORS WHEN REQUIRED. ELECTRICAL CONTRACTOR SHALL REFERENCE ELEVATOR SPECIFICATIONS AND COORDINATE ALL REQUIREMENTS WITH ELEVATOR MANUFACTURER FOR ALL ELECTRICAL REQUIREMENTS PRIOR TO ROUGH-IN. COORDINATE QUANTITY & LOCATION OF FIRE SUPPRESSION RISERS AND TAMPER SWITCHES WITH FIRE SUPPRESSION PLANS. VERIFY WITH STATE CODE TO PROVIDE SMOKE DETECTION FOR ELEVATOR, PROVIDE AND INSTALLED BY E.C. CONNECT TO FIRE ALARM SYSTEM UNLESS NOT ALLOWED BY STATE CODE. PROVIDE POWER AND CONTROL TO SIGNAGE, VERIFY EXACT LOCATION WITH ARCHITECTURAL ELEVATIONS AND FINAL CONNECTIONS WITH SIGNAGE SHOP DRAWINGS ELEV. SUMP PUMP, PROVIDE POWER TO CONTROL PANEL. PROVIDED WITH UNIT AND WIRE PER MANUFACTURERS REQUIREMENTS. COORDINATE LOCATION W/PLUMBING PLANS. VERIFY WITH STATE CODE TO PROVIDE SMOKE DETECTION FOR ELEVATOR, PROVIDE AND INSTALLED BY E.C. CONNECT TO FIRE ALARM SYSTEM UNLESS NOT ALLOWED BY STATE CODE. PROVIDE POWER TO MOTORIZED PROJECTION SCREEN AND INSTALL CONTROLS PROVIDED WITH SCREENS AS SHOWN. PROVIDE SINGLE GANG BOX AT 46" A.F.F. FOR RF BLIND CONTROLLER PROVIDED WITH BLINDS. PROVIDE RECEPTACLE AT TOP RIGHT OF EACH SHADE FOR SHADE TO PLUG INTO. COORDINATE EXACT LOCATION WITH SUPPLIER/INSTALLER. REFER TO ARCHITECTURAL MILLWORK DETAILS FOR LOCATION OF ALL OUTLETS LOCATED AT CABINETS. REFER TO ARCHITECTURAL ELEVATIONS FOR MOUNTING HEIGHTS OF OUTLET/TV JACK. PROVIDE POWER TO DOOR OPERATORS, MOTION SENSOR INTEGRAL WITH DOOR. COORDINATE WITH DOOR SUPPLIER INSTALLER PROVIDE 1/2" CONDUIT TO ACCESSIBLE CEILING SPACE AND SINGLE GANG BOX FOR ALL MECHANICAL WALL MOUNTED TEMPERATURE SENSORS, SEE MECHANICAL PLANS FOR LOCATIONS. PROVIDE F.A. CONNECTION FOR LOCAL AUXILIARY SMOKE ALARM CONTACT AND 120V POWER FOR ELEVATOR SMOKE CURTAIN. ALL FOUR SMOKE CURTAINS ARE CONNECTED TO THE SAME EMERGENCY CIRCUIT AS SHOWN. SYSTEM WILL NOT DEPLOY ON GENERAL ALARM. SCREEN REWIND SWITCH DROPS DOWN WITH CURTAIN. PROVIDE 1/2" CONDUIT TO ACCESSIBLE CEILING SPACE AND SINGLE GANG BOX FOR ALL MECHANICAL WALL MOUNTED TEMPERATURE SENSORS, SEE MECHANICAL PLANS FOR LOCATIONS. 1 2 4 5 6 7 8 9 10 15 12 13 14 3 11 16 17 GENERAL POWER NOTES: 1. 2. 3. 4. 5. 6. 7. POWER KEY NOTES: ALL 15A & 20A 120V NON-LOCKING RECEPTACLES WITHIN CHILDCARE AREAS (AGES 7 & UNDER) SHALL BE LISTED TAMPER RESISTANT PER NEC 406.12. THIS INCLUDES GUEST ROOMS. MOUNT PANELS, TRANSFORMERS, DISCONNECT SWITCHES, AND COMBINATION MOTOR STARTERS WITH ADEQUATE CLEARANCES IN ACCORDANCE WITH NEC 110. VOLTAGE DROP TO MEET ASHRAE 90.1 (2007) ELEMENT ROOMS WHERE PANEL IS INDICATED - LABEL PANELS IN EACH ROOM WITH FINAL ROOM NUMBERS, COORDINATE WITH ARCHITECT FOR FINAL ROOM NUMBERING. DENOTED ON PLAN AS BPG (FLOOR #)-XX. "XX" DENOTE ROOM NUMBER INSTALL FIRE ALARM PER MARRIOTT'S MODULE 14 STANDARDS INSTALL PER LATEST NEC CODE: 2008 NEC NOT ALL POWER KEY NOTES ARE USED ON EACH FLOOR. 18 19 20 Engin ngir LLC8200 PEACHTREE AVE. ROCKFORD, MI 49341 P. 616-340-9627 SCALE: 1/4" = 1'-0" 1 EP221 ENLARGED FIRST FLOOR - POWER P:\2018\2018388 Aloft-Element Carmel\Working Drawings\EP221 -Carmel DB.dwg, 5/26/2020 2:36:05 PM, cll09/28/20 LIGHTING KEYNOTES: PROVIDE POWER TO SIGNAGE REFER TO ARCH ELEVATIONS. COORDINATE WITH FINAL SIGNAGE PLANS. LOCAL SWITCHES TO OVERRIDE OCCUPANCY SENSOR OFF FOR AV USAGE. PROVIDE LOCAL DIMMER SWITCH AT PANEL TO SET LIGHTING LEVEL AT ONSET OF JOB. PROVIDE DIMMING EMERGENCY TRANSFER DEVICE FOR DIMMED CORRIDOR LOADS TO BRING EMERGENCY CORRIDOR LIGHTING TO 100% IN GENERATOR MODE. LIGHTS RUN 24/7. L2 L1 GENERAL LIGHTING NOTES: 1. 2. 3. 4. 5. 6. 7. 8. EGRESS ILLUMINATION LEVELS MEET NFPA 101 OR LOCAL CODE LIGHTING DESIGN COMPLIES WITH 2010 INDIANA ENERGY CODE/ASHRAE 90.1 2007 VOLTAGE DROP TO MEET ASHRAE 90.1 (2007) CONNECT CORRIDOR, ELEVATOR LOBBY AND CORRIDOR FIXTURES TO EMERGENCY CIRCUIT AND NORMAL CIRCUIT, RUN 24/7, REFER TO LIGHTING CONTROL SCHEDULE OR PLANS FOR CIRCUITING CONNECT EMERGENCY LIGHTING TO UL LISTED 924 EMERGENCY TRANSFER DEVICE FOR ALL EMERGENCY LOADS. EMERGENCY LIGHTING MAY BE GROUPED TOGETHER ON ONE TRANSFER DEVICE SIZED FOR LOAD PER LIGHTING ZONES. CONNECT EXIT SIGNS TO EMERGENCY LIGHTING CIRCUIT FEEDING LIGHTING IN AREA AHEAD OF SWITCHING. ELEMENT: CORRIDOR LIGHTS R-02 TO BE CONNECTED TO IC-68/EM1-20. LIGHTING TO RUN 24/7. REFER TO KEY NOTE L3. DECORATIVE FIXTURE PG-401 TO BE CONNECTED TO IC-68, SCONCE LIGHTING PG-402 TO BE CIRCUITED TO IC-70. L3 24 X 2421 X 4221 X 4221 X 42ALR04 ALK-05B ALK-06 ALK-06 ALM-407 ALR-01 ALR-01 ALK-05B ALK-06 ALK-06 AP1 AP1/E AP1 AP1 X104 XR1 XR1/E XR1 XR1 XR1 XR1/E XR1/E XR1 X105 EXTERIOR SLOPED CANOPY LIGHTING. REFER TO ARCH ELEVATIONS FOR EXACT LOCATION XF1-X X120 EXTERIOR SIDE LIGHTING. PROVIDE ONE VERTICAL RUN OF FIXTURE - REFER TO ARCH ELEVATIONS FOR EXACT LOCATION EXTERIOR DOWNLIGHTS IN CANOPY. REFER TO ARCH ELEVATIONS FOR EXACT LOCATION EM1-30 XR1/E XR1/E EM1-30 EM1-30 EM1-30 EM1-30 S2 S2 S2 S2 S2 EM1-34 S2 LM-405/LM-405B LM-403/LM-403B LM-402LM-402B ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 E101 S2S2 X112 XF1-X XF1-X X119 EXTERIOR SITE LIGHTING. PROVIDE ONE VERTICAL RUN OF FIXTURE - XF1-X REFER TO ARCH ELEVATIONS FOR EXACT LOCATION VERITICAL APPROXIMATE HEIGHT - 50'-0" AC1 AC1-X1 25' X114 EXTERIOR SIDE LIGHTING. PROVIDE THREE RUNS OF FIXTURES HORIZONTAL RUN (1) -78'-0" VERTICAL RUN (1) - 60'-0" HORIZONTAL RUN (1) - 146'-0" REFER TO ARCH ELEVATIONS FOR EXACT LOCATION X113 ALR-04ALR-04 ALR-04 E103 S2/E EM1-34 S2/E EXTERIOR BUILDING OUTLINE. REFER TO ARCH ELEVATIONS FOR EXACT LOCATION AND LENGTH. ME101 ME103 UP TO LIGHTS ABOVE FW1 FW1 EEXW1E E L L EM1-19 Engin ngir LLC8200 PEACHTREE AVE. ROCKFORD, MI 49341 P. 616-340-9627 SCALE: 1/4" = 1'-0" 1 EL228 ENLARGED FIRST FLOOR - ELEMENT EXTERIOR LIGHTING SCALE: 1/4" = 1'-0" 2 EL228 ENLARGED FIRST FLOOR - ALOFT EXTERIOR LIGHTING SCALE: 1/4" = 1'-0" 3 EL228 ENLARGED FIRST FLOOR - LIGHTING P:\2018\2018388 Aloft-Element Carmel\Working Drawings\EL228 -Carmel DB.dwg, 5/26/2020 2:34:24 PM, cll09/28/20 LIGHTING KEYNOTES: PROVIDE POWER TO SIGNAGE REFER TO ARCH ELEVATIONS. COORDINATE WITH FINAL SIGNAGE PLANS. LOCAL SWITCHES TO OVERRIDE OCCUPANCY SENSOR OFF FOR AV USAGE. PROVIDE LOCAL DIMMER SWITCH AT PANEL TO SET LIGHTING LEVEL AT ONSET OF JOB. PROVIDE DIMMING EMERGENCY TRANSFER DEVICE FOR DIMMED CORRIDOR LOADS TO BRING EMERGENCY CORRIDOR LIGHTING TO 100% IN GENERATOR MODE. LIGHTS RUN 24/7. L2 L1 GENERAL LIGHTING NOTES: 1. 2. 3. 4. 5. 6. 7. 8. EGRESS ILLUMINATION LEVELS MEET NFPA 101 OR LOCAL CODE LIGHTING DESIGN COMPLIES WITH 2010 INDIANA ENERGY CODE/ASHRAE 90.1 2007 VOLTAGE DROP TO MEET ASHRAE 90.1 (2007) CONNECT CORRIDOR, ELEVATOR LOBBY AND CORRIDOR FIXTURES TO EMERGENCY CIRCUIT AND NORMAL CIRCUIT, RUN 24/7, REFER TO LIGHTING CONTROL SCHEDULE OR PLANS FOR CIRCUITING CONNECT EMERGENCY LIGHTING TO UL LISTED 924 EMERGENCY TRANSFER DEVICE FOR ALL EMERGENCY LOADS. EMERGENCY LIGHTING MAY BE GROUPED TOGETHER ON ONE TRANSFER DEVICE SIZED FOR LOAD PER LIGHTING ZONES. CONNECT EXIT SIGNS TO EMERGENCY LIGHTING CIRCUIT FEEDING LIGHTING IN AREA AHEAD OF SWITCHING. ELEMENT: CORRIDOR LIGHTS R-02 TO BE CONNECTED TO IC-68/EM1-20. LIGHTING TO RUN 24/7. REFER TO KEY NOTE L3. DECORATIVE FIXTURE PG-401 TO BE CONNECTED TO IC-68, SCONCE LIGHTING PG-402 TO BE CIRCUITED TO IC-70. L3 UP TO LIGHTS ABOVE FW1 FW1 XW1 EXW1 XW1 XW1 E E1 E L EE1 EL EE EEE E1 E1EE L CS M2 CS M3 ALK-06 ALK-06ALK-05BA2A2 A2 JJ J J PR-301PR-301 PR-301 PR-301 PR-301 PR-301 PR-301 PR-301 LT-300 LT-300 LT-300 LT-300LT-300 LT-300 ALR-01 NL ALR-01 NL ALR-01 ALR-01ALR-01 ALR-01 ALR-01 ALR-01ALR-01 ALR-01 ALR-01 ALR-01ALR-01 ALR-01 ALR-01 ALR-01 ALR-01 ALR-01 ALR-01 ALR-01 ALR-01 ALR-01 A2 LT325 LT325 LT325 1A-76 1C-23 1A-76 C1E ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 IR IR ALR-04 ALR-04 ALR-04 ALR-04 ALR-04E LM204 M203 M201 M202 R3 LT-300 LT-300 LT-300LT-300 M302 M304 J A2 A2 A2 A2 ALR-04E L EM-17 ALR-04 R3 ALR-04 ALR-04 OS 1A-76 OS ALR-04 ALR-04 ALR-04ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04ALR-04 ALR-04 ALR-04 ALR-04 ALR-04ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 LT-300 LT-300 E1 OS M301 A024 EM1-30 EM1-30 EM1-30 PF02 EM1-30 OS OS M303 C1E ALR-04 ALR-04 ALR-04 CS PF ALM-404 VC VC C1A C1AE C1A C1A C1A C1AE C1A C1A C1A C1AE C1A C1AE C1A C1A C1AE C1A C1A C1A C1A C1A C1A C1A C1AC1A C1A C1AEC1A C1AE C1A C1A C1A C1AE C1AE LT325 Engin ngir LLC8200 PEACHTREE AVE. ROCKFORD, MI 49341 P. 616-340-9627 SCALE: 1/4" = 1'-0" 1 EL227 ENLARGED FIRST FLOOR - LIGHTING P:\2018\2018388 Aloft-Element Carmel\Working Drawings\EL227 -Carmel DB.dwg, 5/27/2020 10:29:37 AM, cll09/28/20 ALK-05B ALK-06 ALK-06 E E1 ALK-06 ALK-06ALK-05BALK-06 ALK-06ALM-401 A08 ALM-401 ALM-403 ALK-05B ALK-06 ALK-06 ALK-05B ALK-06 ALK-06 ALM-501C ALM-501B J J J J ALM-404 J J J ALK-06 ALK-06ALK-05BALK-05B ALK-06 ALK-06 ALK-06 ALK-06ALK-05BTYPE ALJ-09A MOUNTED TOP AND BOTTOM TO BACKLIGHT SCREEN, REFER TO ARCH DETAIL, ALR-01 ALR-01 ALM-501B J ALM-407ALR-01 ALR-01 ALK-06 ALK-06ALK-05BALK-05B ALK-06 ALK-06 ALK-06 ALK-06ALK-05BALK-06 ALK-06ALK-05BALK-06 ALK-06ALK-05BALK-06LM-402/LM-402B LM-402/ LM-402B C1E C1E C1E C1EALK-05BC1E C1E A27 C1 C1E ALK-05B ALK-06 ALK-06 ALK-05B ALK-06 ALK-06 ALR-01 A17 XF1-X X120ALK-06 ALK-06ON-OFF SWITCH FOR PATIO BARBAQUE ALM-404 ALR-04 ALR-04 E E1 L A05 A06 A21 A022 A023 A16 A07 A03 A024 E ALK-06 ALK-06ALK-05BA17 C1E C1E C1E C1E C1E C1E C1E CS PF CS AEALM-404 LIGHTING KEYNOTES: PROVIDE POWER TO SIGNAGE REFER TO ARCH ELEVATIONS. COORDINATE WITH FINAL SIGNAGE PLANS. LOCAL SWITCHES TO OVERRIDE OCCUPANCY SENSOR OFF FOR AV USAGE. PROVIDE LOCAL DIMMER SWITCH AT PANEL TO SET LIGHTING LEVEL AT ONSET OF JOB. PROVIDE DIMMING EMERGENCY TRANSFER DEVICE FOR DIMMED CORRIDOR LOADS TO BRING EMERGENCY CORRIDOR LIGHTING TO 100% IN GENERATOR MODE. LIGHTS RUN 24/7. L2 L1 GENERAL LIGHTING NOTES: 1. 2. 3. 4. 5. 6. 7. 8. EGRESS ILLUMINATION LEVELS MEET NFPA 101 OR LOCAL CODE LIGHTING DESIGN COMPLIES WITH 2010 INDIANA ENERGY CODE/ASHRAE 90.1 2007 VOLTAGE DROP TO MEET ASHRAE 90.1 (2007) CONNECT CORRIDOR, ELEVATOR LOBBY AND CORRIDOR FIXTURES TO EMERGENCY CIRCUIT AND NORMAL CIRCUIT, RUN 24/7, REFER TO LIGHTING CONTROL SCHEDULE OR PLANS FOR CIRCUITING CONNECT EMERGENCY LIGHTING TO UL LISTED 924 EMERGENCY TRANSFER DEVICE FOR ALL EMERGENCY LOADS. EMERGENCY LIGHTING MAY BE GROUPED TOGETHER ON ONE TRANSFER DEVICE SIZED FOR LOAD PER LIGHTING ZONES. CONNECT EXIT SIGNS TO EMERGENCY LIGHTING CIRCUIT FEEDING LIGHTING IN AREA AHEAD OF SWITCHING. ELEMENT: CORRIDOR LIGHTS R-02 TO BE CONNECTED TO IC-68/EM1-20. LIGHTING TO RUN 24/7. REFER TO KEY NOTE L3. DECORATIVE FIXTURE PG-401 TO BE CONNECTED TO IC-68, SCONCE LIGHTING PG-402 TO BE CIRCUITED TO IC-70. L3 ALM-404 J J J ALK-06 ALK-06ALK-05BALK-05B ALK-06 ALK-06 ALK-06 ALK-06ALK-05BCS TE1 OS ALK-06 ALK-06ALK-05BALK-09 ALK-09ALK-05BALK-09 ALK-09ALK-09 ALK-09 PR-301 PR-301 PR-301 PR-402 PR-402 J4 ALR-01 NL ALR-01 NL ALR-01 ALR-01 ALR-01ALR-01 ALR-01 ALR-01 ALR-01 ALR-01 ALK-09 ALK-09 LT325 LT325 ALR-04 1A-76 1C-23 C1E C1E ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 C1 C1E EE1 TE-019 ALR-04 C1E IR PF01 C1E A18 ALK-05BALK-05B OS 1A-76 OS TE-019 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04ALR-04 TE-019 TE-019 EM1-34 EM1-34 ALK-05B ALK-06 ALK-06 ALK-05B ALK-06 ALK-06 A20 A21 A15 C1 TE-103 TE-101 TE-102 ALR-04 X111 A024 ALK-06 ALK-06ALK-05BA17 PF02 C1E C1E CS PF CS PF ALM-404 PR-402 Engin ngir LLC8200 PEACHTREE AVE. ROCKFORD, MI 49341 P. 616-340-9627 SCALE: 1/4" = 1'-0" 1 EL226 ENLARGED FIRST FLOOR - LIGHTING SCALE: 1/4" = 1'-0" 2 EL226 ENLARGED FIRST FLOOR - LIGHTING P:\2018\2018388 Aloft-Element Carmel\Working Drawings\EL226 -Carmel DB.dwg, 5/27/2020 10:25:41 AM, cll09/28/20 24 X 48 24 X 24 24 X 4218 X 4218 X 4218 X 4218 X 4218 X 4224 X 5424 X 2421 X 48 21 X 3621 X 42 21 X 42 21 X 42 21 X 42 21 X 6021 X 60 21 X 60 21 X 60 21 X 4221 X 4221 X 42 21 X 4221 X 42 21 X 4224 X 54 24 X 36J ALR04 ALR04 ALR04 ALK-07 ALJ-01 ALJ-01 ALJ-01 ALJ-01 ALJ-01 ALJ-01 ALJ-01 ALJ-01 ALJ-01 ALJ-01 ALJ-01 ALJ-01 ALJ-01 ALJ-01 ALJ-01 ALJ-01E ALJ-01 ALJ-01 ALJ-01 ALJ-01 ALJ-01 ALJ-01 ALJ-01 ALJ-01E ALJ-01 ALJ-01 ALJ-01 ALJ-01 ALJ-01 ALJ-01 ALJ-01 ALJ-01E ALJ-01 ALJ-01 ALJ-01 ALJ-01 ALJ-01 ALJ-01 ALJ-01 ALJ-01E ALJ-01 ALJ-01 ALJ-01 ALJ-01 ALJ-01 ALJ-01 ALJ-01 ALJ-01 ALJ-01 ALJ-01 ALJ-01 ALK-06 EL ALM-501B ALR-01 XW1 EA3 A3 A3 A3 A3 A3 A3 A3 CSK2 XW1 XW1 A3 E E E E1EE1 EL E E E EE1 E1 CS M1 CS M2 ALK-06 ALK-06ALK-05BA3 A3 A3 A3 A3 A3 A3 A3A3 A3 A2 LT-300LT-300 LT-300 LT-300 LT-300 LT-300 LT-300 LT-300 LT-300 LT-300 LT-300 LT-300 LT325 R3 OSE C1E C1EALK-06ALK-05BALK-05BC1E ALR-04 EM1-3 IREM-17 ALR-04 ALR-04 ALR-04 ELE LELM101 M204 M203 M202 K2S-4 1A-76 IRALK-06ALK-06 ALK-06CS OS A2 A2 A2 A2 ALR-04 EL E L ALR-04 ALR-04 ALK-07 ALK-07 ALR-04 ALR-04 ALR-04 ALR-04ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04ALR-04 ALR-04 ALR-04 C1A ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 A022 A023 A01 A09 A10 A11 M104 M102 A04 A03 M103 A024 E EM1-30 EM1-30 EM1-30 OS OS C1E LM-406/LM406/B K2 6A10 CS PF EALM-404 C1A C1A C1A C1AE C1A C1AC1A C1A C1AE C1A C1A C1A C1A C1AE C1A C1AE C1A C1AE C1A C1A C1AE LM-403/LM-403B LT325 LIGHTING KEYNOTES: PROVIDE POWER TO SIGNAGE REFER TO ARCH ELEVATIONS. COORDINATE WITH FINAL SIGNAGE PLANS. LOCAL SWITCHES TO OVERRIDE OCCUPANCY SENSOR OFF FOR AV USAGE. PROVIDE LOCAL DIMMER SWITCH AT PANEL TO SET LIGHTING LEVEL AT ONSET OF JOB. PROVIDE DIMMING EMERGENCY TRANSFER DEVICE FOR DIMMED CORRIDOR LOADS TO BRING EMERGENCY CORRIDOR LIGHTING TO 100% IN GENERATOR MODE. LIGHTS RUN 24/7. L2 L1 GENERAL LIGHTING NOTES: 1. 2. 3. 4. 5. 6. 7. 8. EGRESS ILLUMINATION LEVELS MEET NFPA 101 OR LOCAL CODE LIGHTING DESIGN COMPLIES WITH 2010 INDIANA ENERGY CODE/ASHRAE 90.1 2007 VOLTAGE DROP TO MEET ASHRAE 90.1 (2007) CONNECT CORRIDOR, ELEVATOR LOBBY AND CORRIDOR FIXTURES TO EMERGENCY CIRCUIT AND NORMAL CIRCUIT, RUN 24/7, REFER TO LIGHTING CONTROL SCHEDULE OR PLANS FOR CIRCUITING CONNECT EMERGENCY LIGHTING TO UL LISTED 924 EMERGENCY TRANSFER DEVICE FOR ALL EMERGENCY LOADS. EMERGENCY LIGHTING MAY BE GROUPED TOGETHER ON ONE TRANSFER DEVICE SIZED FOR LOAD PER LIGHTING ZONES. CONNECT EXIT SIGNS TO EMERGENCY LIGHTING CIRCUIT FEEDING LIGHTING IN AREA AHEAD OF SWITCHING. ELEMENT: CORRIDOR LIGHTS R-02 TO BE CONNECTED TO IC-68/EM1-20. LIGHTING TO RUN 24/7. REFER TO KEY NOTE L3. DECORATIVE FIXTURE PG-401 TO BE CONNECTED TO IC-68, SCONCE LIGHTING PG-402 TO BE CIRCUITED TO IC-70. L3 Engin ngir LLC8200 PEACHTREE AVE. ROCKFORD, MI 49341 P. 616-340-9627 SCALE: 1/4" = 1'-0" 1 EL225 ENLARGED FIRST FLOOR - LIGHTING P:\2018\2018388 Aloft-Element Carmel\Working Drawings\EL225 -Carmel DB.dwg, 5/26/2020 2:31:40 PM, cll09/28/20 SDP1E3 J4E BPLS1RELAYPNL 1DP1BP-1A MDPATS-1 NEMA 3R AST-2 NEMA 3R ATS-3BP-1B BP-1CJ8E J8E 3 BPP2A-9J8E ALR-04 ALR-04 EE2 EEE L L E2 EE2 PG401-1 R-02 PG402 R-02 R-02 R-02 R-02 PG401-1 PG401-1 PG401-1 PG402 PG402 PG402 PG402 PG402 PG402 PG402E E1EL XW1 XW1 A3 A3 IRE IRA3 A2 OS A3 J4E J4E J4E 33RE400 RE400 RE400 RE400 RE400 RE400 RE400 RE400 RE400 RE400 RE400/E EM1-14 RE400 1A-74 1A-74 1B-46 1B-46 1B-46 EM1-1 EM1-1 EM1-1 ALR-04 ALR-04ALR-04 EIR TE-019 TE-019 EE1 EM1-34 E L IRIRP-18 E114 OS OS ALR-01 ALR-01 ALR-01ALR-01 ALR-01 ALR-01 ALR-01 ALR-01 ALR-01 ALR-01 ALR-01 ALR-01 ALR-01 ALR-01 ALR-01 ALR-01 ALR-01ALR-01 ALR-01 ALR-01 RE400/E EM1-14 RE400/E EM1-14 EM1-34 EM1-1EM1-34 ALR-03 EM1-34 CS P E2 XW1 PR-401B TE-019 ALR-04 ALR-04 ALR-04 ALR-04 ALR-03 RE400 EM1-34 EM1-34 EM1-34 EM1-34 EM1-34 EM1-34 EM1-34EM1-34 NL EM1-34 E113 EE E1 BPG-2 BPG-2 BPG-2E E EEM1-30 PG402 PG402 EM1-19 OSOS ALR-03 ALR-03 ALR-03 ALR-03 ALR-03 ALR-03 NL NL 1B-46 EM1-30 S S VC S15 15 15 S16 14 14 S 14 S 14 S 13 S 13 S 14 J J J J J J J J EM1-34 ALR-03 EM1-34 ALR-03 EM1-34 ALR-03 ALK-04 ALK-04 ALK-04 ALK-04 ALK-04 ALK-04 ALK-04 ALK-04ALK-04 ALK-04 ALK-04 ALK-04 102 101 Q EM1-30 POOL LTG Q. TO REMOTE DRIVERS IN POOL EQUIPMENT ROOM R1-1 LIGHTING KEYNOTES: PROVIDE POWER TO SIGNAGE REFER TO ARCH ELEVATIONS. COORDINATE WITH FINAL SIGNAGE PLANS. LOCAL SWITCHES TO OVERRIDE OCCUPANCY SENSOR OFF FOR AV USAGE. PROVIDE LOCAL DIMMER SWITCH AT PANEL TO SET LIGHTING LEVEL AT ONSET OF JOB. PROVIDE DIMMING EMERGENCY TRANSFER DEVICE FOR DIMMED CORRIDOR LOADS TO BRING EMERGENCY CORRIDOR LIGHTING TO 100% IN GENERATOR MODE. LIGHTS RUN 24/7. L2 L1 GENERAL LIGHTING NOTES: 1. 2. 3. 4. 5. 6. 7. 8. EGRESS ILLUMINATION LEVELS MEET NFPA 101 OR LOCAL CODE LIGHTING DESIGN COMPLIES WITH 2010 INDIANA ENERGY CODE/ASHRAE 90.1 2007 VOLTAGE DROP TO MEET ASHRAE 90.1 (2007) CONNECT CORRIDOR, ELEVATOR LOBBY AND CORRIDOR FIXTURES TO EMERGENCY CIRCUIT AND NORMAL CIRCUIT, RUN 24/7, REFER TO LIGHTING CONTROL SCHEDULE OR PLANS FOR CIRCUITING CONNECT EMERGENCY LIGHTING TO UL LISTED 924 EMERGENCY TRANSFER DEVICE FOR ALL EMERGENCY LOADS. EMERGENCY LIGHTING MAY BE GROUPED TOGETHER ON ONE TRANSFER DEVICE SIZED FOR LOAD PER LIGHTING ZONES. CONNECT EXIT SIGNS TO EMERGENCY LIGHTING CIRCUIT FEEDING LIGHTING IN AREA AHEAD OF SWITCHING. ELEMENT: CORRIDOR LIGHTS R-02 TO BE CONNECTED TO IC-68/EM1-20. LIGHTING TO RUN 24/7. REFER TO KEY NOTE L3. DECORATIVE FIXTURE PG-401 TO BE CONNECTED TO IC-68, SCONCE LIGHTING PG-402 TO BE CIRCUITED TO IC-70. L3 Engin ngir LLC8200 PEACHTREE AVE. ROCKFORD, MI 49341 P. 616-340-9627 SCALE: 1/4" = 1'-0" 1 EL224 ENLARGED FIRST FLOOR - LIGHTING NOTE: ELEMENT GUEST SUITES POWER AND LIGHTING CIRCUIT SHOWN ON E612, PANEL BG-2 FOR THIS FLOOR.P:\2018\2018388 Aloft-Element Carmel\Working Drawings\EL224 -Carmel DB.dwg, 5/26/2020 2:28:57 PM, cll09/28/20 24 X 48 24 X 42 24 X 36 24 X 36 24 X 36 24 X 3624 X 4824 X 4224 X 54 R-02 PG401-1 PG401-1 PG402 PG402 A3 A3 IREE E1 CS K1 CSK1 A3 A3 A3 A3 EEA3 A3 A3 A3 A3 S2 S2 S2 S2 S2 J4E LM-405/LM-405B LM-403/LM-403B LM-403/LM-403B LM-405/LM-405B LM-402LM-402B LM-402LM-402B LM-403/LM-403B 1B-46 1B-46 1B-46 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 LM-404/LM-404B ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04ALR-04ALR-04 ALR-04 ALR-04ALR-04ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04ALR-04 E E1 E E1 E E1 LM-407/LM407B (TYP) ALR-04 ALR-04 ALR-04ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 E110 ALR-04ALR-04 ALR-04ALR-04 E101 LM-401/LM401B (TYP) E102 E108 EE1 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 K01 ALR-04 ALR-04 ALR-04 ALR-04ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04ALR-04 ALR-04 ALR-04 E L E1 OS OS ALR-01 ALR-01 ALR-01ALR-01 ALR-01 ALR-01 ALR-01 ALR-01 ALR-01 ALR-01 ALR-01 ALR-01 ALR-01 ALR-01 ALR-01 ALR-01 ALR-01ALR-01 ALR-01 ALR-01 ALR-04 ALR-04 E103 E104 E105 E109 E106 XW1EEE1 EM1-34 S2/E E E PG402 NL NL CS M EM1-19 LIGHTING KEYNOTES: PROVIDE POWER TO SIGNAGE REFER TO ARCH ELEVATIONS. COORDINATE WITH FINAL SIGNAGE PLANS. LOCAL SWITCHES TO OVERRIDE OCCUPANCY SENSOR OFF FOR AV USAGE. PROVIDE LOCAL DIMMER SWITCH AT PANEL TO SET LIGHTING LEVEL AT ONSET OF JOB. PROVIDE DIMMING EMERGENCY TRANSFER DEVICE FOR DIMMED CORRIDOR LOADS TO BRING EMERGENCY CORRIDOR LIGHTING TO 100% IN GENERATOR MODE. LIGHTS RUN 24/7. L2 L1 GENERAL LIGHTING NOTES: 1. 2. 3. 4. 5. 6. 7. 8. EGRESS ILLUMINATION LEVELS MEET NFPA 101 OR LOCAL CODE LIGHTING DESIGN COMPLIES WITH 2010 INDIANA ENERGY CODE/ASHRAE 90.1 2007 VOLTAGE DROP TO MEET ASHRAE 90.1 (2007) CONNECT CORRIDOR, ELEVATOR LOBBY AND CORRIDOR FIXTURES TO EMERGENCY CIRCUIT AND NORMAL CIRCUIT, RUN 24/7, REFER TO LIGHTING CONTROL SCHEDULE OR PLANS FOR CIRCUITING CONNECT EMERGENCY LIGHTING TO UL LISTED 924 EMERGENCY TRANSFER DEVICE FOR ALL EMERGENCY LOADS. EMERGENCY LIGHTING MAY BE GROUPED TOGETHER ON ONE TRANSFER DEVICE SIZED FOR LOAD PER LIGHTING ZONES. CONNECT EXIT SIGNS TO EMERGENCY LIGHTING CIRCUIT FEEDING LIGHTING IN AREA AHEAD OF SWITCHING. ELEMENT: CORRIDOR LIGHTS R-02 TO BE CONNECTED TO IC-68/EM1-20. LIGHTING TO RUN 24/7. REFER TO KEY NOTE L3. DECORATIVE FIXTURE PG-401 TO BE CONNECTED TO IC-68, SCONCE LIGHTING PG-402 TO BE CIRCUITED TO IC-70. L3 Engin ngir LLC8200 PEACHTREE AVE. ROCKFORD, MI 49341 P. 616-340-9627 SCALE: 1/4" = 1'-0" 1 EL223 ENLARGED FIRST FLOOR - LIGHTING NOTE: ELEMENT GUEST SUITES POWER AND LIGHTING CIRCUIT SHOWN ON E612, PANEL BG-2 FOR THIS FLOOR.P:\2018\2018388 Aloft-Element Carmel\Working Drawings\EL223 -Carmel DB.dwg, 5/26/2020 2:25:53 PM, cll09/28/20 14 X 4214 X 42 EE2 EE2 B3 B3B3 IRB2 B2IR ALK-06ALK-05BIRA13 BUILT IN A3 A3 IRALK-09 ALK-091A-74 1A-74 1A-74 ALR-04ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 1A-74 A3 C1 E E1EE1 TE-019TE-019 TE-019 TE-019 TE-019 A19 EM1-34 EL C1E A18 OS EM1-34 EM1-34 EM1-34 ALR-03 EM1-34 E2 XW1 1B-66 WP 1B-68 WP1B-68 WP 1B-70 WP MOUNT @ 72" FOR STRING OF LIGHTS MOUNT @ 72" FOR STRING OF LIGHTS TYPE TE-403 REFER TO DRAWING E300 FOR EQUIPMENT IN BAR. AND STORAGE. E4 MOUNT TO GATE MOUNT @ 72" FOR STRING OF LIGHTS TYPE TE-403 MOUNT @ 72" FOR STRING OF LIGHTS TYPE TE-403 MOUNT @ 72" FOR STRING OF LIGHTS TYPE TE-403 TE-019 TE-019 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-03 TE-019 TE-019 EM1-34 EM1-34 EM1-34EM1-34 EM1-34EM1-34 EM1-34 TYPE TE-403 STRING OF LIGHTS TYPICAL TYPE TE-403 STRING OF LIGHTS TYPICAL TYPE TE-403 STRING OF LIGHTS TYPICAL TYPE TE-403 STRING OF LIGHTS TYPICAL ALK-05B ALK-06 ALK-06 A20 A15 E E1 TE-102 ALR-04 X111 EE E4 MOUNT TO GATE X109 X110 X115 X116 E ALK-06ALK-05BEACH STRING TO BE 48'-0". PROVIDE (2) STRINGS PER NOTED LOCATION EM1-30 C1E ALR-03 ALR-03 S 16S16 S16 S 16 S 7 ALK-04 ALK-04 ALK-04 LIGHTING KEYNOTES: PROVIDE POWER TO SIGNAGE REFER TO ARCH ELEVATIONS. COORDINATE WITH FINAL SIGNAGE PLANS. LOCAL SWITCHES TO OVERRIDE OCCUPANCY SENSOR OFF FOR AV USAGE. PROVIDE LOCAL DIMMER SWITCH AT PANEL TO SET LIGHTING LEVEL AT ONSET OF JOB. PROVIDE DIMMING EMERGENCY TRANSFER DEVICE FOR DIMMED CORRIDOR LOADS TO BRING EMERGENCY CORRIDOR LIGHTING TO 100% IN GENERATOR MODE. LIGHTS RUN 24/7. L2 L1 GENERAL LIGHTING NOTES: 1. 2. 3. 4. 5. 6. 7. 8. EGRESS ILLUMINATION LEVELS MEET NFPA 101 OR LOCAL CODE LIGHTING DESIGN COMPLIES WITH 2010 INDIANA ENERGY CODE/ASHRAE 90.1 2007 VOLTAGE DROP TO MEET ASHRAE 90.1 (2007) CONNECT CORRIDOR, ELEVATOR LOBBY AND CORRIDOR FIXTURES TO EMERGENCY CIRCUIT AND NORMAL CIRCUIT, RUN 24/7, REFER TO LIGHTING CONTROL SCHEDULE OR PLANS FOR CIRCUITING CONNECT EMERGENCY LIGHTING TO UL LISTED 924 EMERGENCY TRANSFER DEVICE FOR ALL EMERGENCY LOADS. EMERGENCY LIGHTING MAY BE GROUPED TOGETHER ON ONE TRANSFER DEVICE SIZED FOR LOAD PER LIGHTING ZONES. CONNECT EXIT SIGNS TO EMERGENCY LIGHTING CIRCUIT FEEDING LIGHTING IN AREA AHEAD OF SWITCHING. ELEMENT: CORRIDOR LIGHTS R-02 TO BE CONNECTED TO IC-68/EM1-20. LIGHTING TO RUN 24/7. REFER TO KEY NOTE L3. DECORATIVE FIXTURE PG-401 TO BE CONNECTED TO IC-68, SCONCE LIGHTING PG-402 TO BE CIRCUITED TO IC-70. L3 Engin ngir LLC8200 PEACHTREE AVE. ROCKFORD, MI 49341 P. 616-340-9627 SCALE: 1/4" = 1'-0" 1 EL222 ENLARGED FIRST FLOOR - LIGHTING P:\2018\2018388 Aloft-Element Carmel\Working Drawings\EL222 -Carmel DB.dwg, 5/26/2020 2:21:30 PM, cll09/28/20 22 X 3914 X 4214 X 42 B3 IR 33OS B3 B3 B3 IR EEA2 IR A3 A3 A3 A3 EEO MOUNT SWITCH ADJ. TO LADDER IN PIT. FIELD COORD LIGHT AND SWITCH LOCATION TYPICAL EM1-8 O EM1-8 O EM1-10 O EM1-10 O EM1-6 A2 A3 A3 A2 A2 A3 A3 A2 A3 A3 A3 OSIR A3 A3 IR B3 B3B3 B3 B3 IRB2 B2IR J4E J4E ALK-06 ALK-06ALK-05BALM-401 A08 ALM-401 ALK-05B ALK-06 ALK-06 TYPE ALJ-09A MOUNTED TOP AND BOTTOM TO BACKLIGHT SCREEN, REFER TO ARCH DETAIL, ALR-01 ALR-01 A3 OS IRIR B2 B2 A3 A3 A2 A2 A2 A2 A2 OS OS A13 BUILT IN LTG A2 ALK-06 ALK-06ALK-05B ALK-06 ALK-06ALK-06J8E A3 A3 A3 A3 A3 IR A3 ALJ-09A ALJ-09AALJ-09A1A-74 J4E EM1-3 1A-74 1A-74 1A-74 1A-74 1A-74 1A-74 1A-74 1A-74 1A-74 1A-74 1A-74 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 1A-61 1A-74 1A-61 1A-61 LT305 LT305 OS ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 E E1 ALR-04ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 ALR-04 D D DIR1A-61 1A-61 EIR IREM1-3 1A-74 ALM-401 ALM-401 C1E E E1 A27 IR1A-61 IR A3 C1 C1E A19 E108 EE1 ALK-05B ALR-01 A17 A26 XF1-X XF1-X X119 EXTERIOR SITE LIGHTING. PROVIDE ONE VERTICAL RUN OF FIXTURE - XF1-X REFER TO ARCH ELEVATIONS FOR EXACT LOCATION VERITICAL APPROXIMATE HEIGHT - 50'-0" PROVIDE ONE VERTICAL RUN OF FIXTURE - REFER TO ARCH ELEVATIONS FOR EXACT LOCATION AC1 AC1-X1 25' X114 EXTERIOR SIDE LIGHTING. PROVIDE THREE RUNS OF FIXTURES HORIZONTAL RUN (1) -78'-0" VERTICAL RUN (1) - 60'-0" HORIZONTAL RUN (1) - 146'-0" REFER TO ARCH ELEVATIONS FOR EXACT LOCATION X113 ALR-04ALR-04 ALR-04 ALR-04 ALR-04 OS ALR-04 ALR-04 ALR-04 ALR-04 EL ON-OFF SWITCH FOR PATIO BARBAQUE REFER TO DRAWING E300 FOR EQUIPMENT IN BAR. AND STORAGE. ALM-404 ALR-04 ALR-04 A20 OS NLNL L2 A05 A14 E113 E111 EE1 C1E A12 EXTERIOR BUILDING OUTLINE. REFER TO ARCH ELEVATIONS FOR EXACT LOCATION AND LENGTH. E E ME101 ME102 ME103 1A-74 ALK-06 ALK-06ALK-05BA17 C1E A28 CS M CS A EALM-404 ALM-404 VC VC VC VC VC VC VC S S 12 12 13 16 12 VC9 S 10 10 S 9S 9 S11 LM-403/LM-403B LIGHTING KEYNOTES: PROVIDE POWER TO SIGNAGE REFER TO ARCH ELEVATIONS. COORDINATE WITH FINAL SIGNAGE PLANS. LOCAL SWITCHES TO OVERRIDE OCCUPANCY SENSOR OFF FOR AV USAGE. PROVIDE LOCAL DIMMER SWITCH AT PANEL TO SET LIGHTING LEVEL AT ONSET OF JOB. PROVIDE DIMMING EMERGENCY TRANSFER DEVICE FOR DIMMED CORRIDOR LOADS TO BRING EMERGENCY CORRIDOR LIGHTING TO 100% IN GENERATOR MODE. LIGHTS RUN 24/7. L2 L1 GENERAL LIGHTING NOTES: 1. 2. 3. 4. 5. 6. 7. 8. EGRESS ILLUMINATION LEVELS MEET NFPA 101 OR LOCAL CODE LIGHTING DESIGN COMPLIES WITH 2010 INDIANA ENERGY CODE/ASHRAE 90.1 2007 VOLTAGE DROP TO MEET ASHRAE 90.1 (2007) CONNECT CORRIDOR, ELEVATOR LOBBY AND CORRIDOR FIXTURES TO EMERGENCY CIRCUIT AND NORMAL CIRCUIT, RUN 24/7, REFER TO LIGHTING CONTROL SCHEDULE OR PLANS FOR CIRCUITING CONNECT EMERGENCY LIGHTING TO UL LISTED 924 EMERGENCY TRANSFER DEVICE FOR ALL EMERGENCY LOADS. EMERGENCY LIGHTING MAY BE GROUPED TOGETHER ON ONE TRANSFER DEVICE SIZED FOR LOAD PER LIGHTING ZONES. CONNECT EXIT SIGNS TO EMERGENCY LIGHTING CIRCUIT FEEDING LIGHTING IN AREA AHEAD OF SWITCHING. ELEMENT: CORRIDOR LIGHTS R-02 TO BE CONNECTED TO IC-68/EM1-20. LIGHTING TO RUN 24/7. REFER TO KEY NOTE L3. DECORATIVE FIXTURE PG-401 TO BE CONNECTED TO IC-68, SCONCE LIGHTING PG-402 TO BE CIRCUITED TO IC-70. L3 Engin ngir LLC8200 PEACHTREE AVE. ROCKFORD, MI 49341 P. 616-340-9627 SCALE: 1/4" = 1'-0" 1 EL221 ENLARGED FIRST FLOOR - LIGHTING P:\2018\2018388 Aloft-Element Carmel\Working Drawings\EL221 -Carmel DB.dwg, 5/26/2020 2:20:05 PM, cll09/28/20 F.A. NOTES: 1. E.C. TO PROVIDE CONNECTION TO ALL DUCT DETECTORS WHETHER SHOWN ON ELECTRICAL DRAWINGS OR NOT. COORDINATE QUANITY AND LOCATIONS WITH MECHANICAL CONTRACTOR SCHEDULES, REVIEWING ALL CFM REQUIREMENTS. PROVIDE DUCT DETECTORS IF NOT NOTED TO BE PROVIDE BY M.C. 2. E.C. TO PROVIDE CONNECTIONS TO ALL FLOW AND TAMPER SWITCHES WHETHER SHOWN ON ELECTRICAL DRAWINGS OR NOT. COORDINATE QUANTITY AND LOCATIONS WITH FIRE PROTECTION DRAWINGS AND/OR DESIGN BUILD CONTRACTOR. 3. E.C. TO PROVIDE EMERGENCY POWER TO FIRE ALARM BOOSTER POWER SUPPLIES WHEN EMERGENCY POWER SYSTEM IS AVAILABLE. T THERMOSTAT. E.C TO ROUGH-IN SINGLE GANG BOX AND 1/2"C. TO ACCESSIBLE CEILING SPACE. 46" TRANSFORMER 72" TO TOPPANELBOARD SURFACE OR FLUSH MTD. BRANCH CIRCUIT THREE PHASE ELECTRIC MOTOR SINGLE PHASE ELECTRIC MOTOR SWITCH - CS/NFDS COMBINATION MAG. STARTER/NON-FUSED DISC. CS/FDS COMBINATION MAG. STARTER/ FUSED DISC. SWITCH - H-DENOTES WITH HAND-OFF-AUTO SW. MANUAL MOTOR STARTER W/PILOT LIGHT "SSU" & FUSESTAT FUSE SW. AND PLUGFUSE HOLDER- BUSSMANN NFDS-HEAVY DUTY NON-FUSED DISCONNECT SWITCH- AT EQUIPT. MAGNETIC MOTOR STARTER-MS 46" 46" 46" 46" 46" 46" AS NOTED FDS-HEAVY DUTY FUSED DISCONNECT SWITCH- DIMMER SW. 46" 46" 46" 46" KEY OPERATED SW.-SPEC. GRADE FOUR WAY SW.-SPEC. GRADE DUPLEX OUTLET-SPEC. GRADE SPECIFICATION GRADE SINGLE POLE OR 3-WAY SWITCH- (2) DUPLEX OUTLET-SPEC. GRADE T F M P F J H --- --- --- ELECTRICAL SYMBOL LEGEND S S S WR D K 4 S S SYMBOL DESCRIPTION 3 MTG. HT. TO C 18" 18" L 18" SPECIAL OUTLET-CHARACTERISTICS AS NOTED ON PLANS AS NOTED 1"C. UP WALL TO CLG. SPACE UNLESS OTHERWISE NOTED JUNCTION BOX -4" SQ. BOX W/ 2 GANG RAISED COVER. CIRCLE AROUND SYMBOL= CEILING MOUNTED CIRCLE AROUND SYMBOL= CEILING MOUNTED OS IRD S IR SWITCH DIMMABLE OCCUPANCY SENSOR PUSH BUTTON 46"PB WITH WEATHERPROOF WHILE IN USE COVER WATER RESISTANT GROUND FAULT CIRCUIT INTERRUPTER SYMBOL NOTES: 1. "AC" DENOTES ABOVE COUNTER. COORDINATE HEIGHT WITH ARCHITECT. 2. "H" DENOTES HORIZONTAL MOUNTING OF DEVICE. 3. "W" DENOTES WALL MOUNTED AT 46" AFF. 4. "B" DENOTES MOUNTED IN BASE. 5. "F" DENOTES MOUNTED IN FACE OF CABINETS. IR S IR SWITCH CS CONTROL STATION 46" 46" 46" C 18"C - DENOTES CONTROLLED VIA RELAY OR OCC SENSOR SPLIT WIRED RECEPTACLE 18"SPECIAL SIMPLEX RECEPTACLE VARIABLE FREQUENCY DRIVE ---VFD FLOOR BOX 1 RECPTACLE WIREMOLD RFB2 ISOLATED GROUND RECEPTACLE 18"IG --- --- --- --- --- --- --- VISUAL ONLY ALARM 80" FIRE ALARM CONTROL RELAY REMOTE ALARM KEY TEST SWITCH WATER FLOW SWITCH 46" 80" 46" O,S,&Y TAMPER SWITCH HEAT DETECTOR DUCT SMOKE DETECTOR AREA SMOKE DETECTOR-PHOTOELECTRIC FIRE ALARM HORN/STROBE LIGHT FIRE ALARM PULL STATION ---CEILING SPEAKER SPEAKER/STROBE LIGHT --- LMTG. HT. TO C DESCRIPTIONSYMBOL SYSTEMS SYMBOL LEGEND SMOKE/HORN BASE FIRE ALARM ANNUNCIATOR PANEL --- --- FIRE ALARM CONTROL PANEL --- F CO CR FS D TS RT F.A.A. F.A.C.P. CO CO-DENOTES COMBO CARBON MONOXIDE/SMOKE ---MAGNETIC DOOR HOLD OPEN DH CARBON MONOXIDE SENSOR. E.C TO ROUGH-IN SINGLE GANG BOX AND 1/2"C. TO ACCESSIBLE CEILING SPACE. DESCRIPTIONSYMBOL LOW VOLTAGE SYMBOL LEGEND PHONE/DATA ROUGH IN WALL PHONE/DATA ROUGH IN MULTIPLE PHONE/DATA ROUGH IN, PHONE/DATA ROUGH IN TV/DATA ROUGH IN TV ROUGH IN MICROPHONE ROUGH IN CEILING MOUNTED PROJECTOR ROUGH IN, REFER TO PLANS TV/DATA ROUGH IN VOLUME CONTROL ROUGH IN MOTORIZED SCREEN UP WITH CONTROL CARD READER ROUGH IN #D VC W MTG. HT. TO CL TV TV TV 44" 18" OR AS NOTED 18" 18" 46" 46"CR SYMBOL NOTES: 1. "AC" DENOTES ABOVE COUNTER. COORDINATE HEIGHT WITH ARCHITECT. 2. "H" DENOTES HORIZONTAL MOUNTING OF DEVICE. 3. "W" DENOTES WALL MOUNTED AT 46" AFF. 4. "B" DENOTES MOUNTED IN BASE. 5. "F" DENOTES MOUNTED IN FACE OF CABINETS. PROJ SCREEN VERIFY WITH ARCH ELEVATIONS TWO (2) CAT 6 AND 1 XLR 18/2 SHIELDED AUDIO RUN TO IDF/AV ROOM. ONE (1) HDMI RUN TO CEILING MOUNTED PROJECTOR. TWO (2) CAT 6 ELECTRICAL ROUGH IN AND POWER 4" SQ. BOX W/1 GANG RAISED COVER IN CEILING WITH 1-1/4" SMURF TUBE OR CONDUIT TO ACCESSIBLE CEILING SPACE. PROVIDE RECEPTACLE AT PROJECTOR IN CEILING FOR POWER 4" SQ. BOX W/1 GANG RAISED COVER. 1-1/4" SMURF TUBE OR CONDUIT. UP WALL TO ACCESSIBLE CEILING SPACE SINGLE GANG JUNCTION BOX 3/4" SMURF TUBE OR CONDUIT TO ACCESSIBLE CEILING SPACE 4" SQ. BOX W/1 GANG RAISED COVER. 1-1/4" SMURF TUBE OR CONDUIT TO ACCESSIBLE CEILING SPACE SINLE GANG JUNCTION BOX 3/4" SMURF TUBE OR CONDUIT TO ACCESSIBLE CEILING SPACE SINGLE GANG JUNCTION BOX 3/4" SMURF TUBE OR CONDUIT TO ACCESSIBLE CEILING SPACE 18" OR AS NOTED 4" SQ. BOX W/1 GANG RAISED COVER. 1-1/4" SMURF TUBE OR CONDUIT. UP WALL TO ACCESSIBLE CEILING SPACE 18" OR AS NOTED SINGLE GANG JUNCTION BOX 3/4" SMURF TUBE OR CONDUIT TO ACCESSIBLE CEILING SPACE SINGLE GANG JUNCTION BOX 3/4" SMURF TUBE OR CONDUIT TO ACCESSIBLE CEILING SPACE SINGLE GANG JUNCTION BOX 3/4" SMURF TUBE OR CONDUIT TO ACCESSIBLE CEILING SPACE 46" 18" OR AS NOTED FOUR COMPARTMENT COMBINATION FLOORBOX - WIREMOLD RFB4 PROVIDE APPROPRIATE DEVICE PLATE FOR LOW VOLTAGE DEVICES 2" CONDUIT FROM LOW VOLTAGE COMPARTMENT STUBBED TO ABOVE ACCESSIBLE CEILING SPACE AT PROJECTOR OR WALL MOUNTED TV OR AS NOTED ON PLAN. PROVIDE (2) DUPLEX RECEPTACLES AND DEVICE PLATES PROVIDE CONCEALED ACCESS COVER SINGLE GANG JUNCTION BOX 3/4" SMURF TUBE OR CONDUIT TO ACCESSIBLE CEILING SPACE TWO COMPARTMENT COMBINATION FLOORBOX - WIREMOLD RFB2 PROVIDE APPROPRIATE DEVICE PLATE FOR LOW VOLTAGE DEVICES 1 1/2" CONDUIT FROM LOW VOLTAGE COMPARTMENT STUBBED TO ACCESSIBLE CEILING SPACE. PROVIDE ONE DUPLEX RECEPTACLE AND DEVICE PLATE PROVIDE CONCEALED ACCESS COVER GUEST ROOMS: SINGLE GANG BOX WITH 3/4" CONDUIT OR SMURF TUBE COMMON AREAS: 4" SQ. BOX W/1 GANG RAISED COVER. 1-1/4" SMURF TUBE OR CONDUIT. UP WALL TO ACCESSIBLE CEILING SPACE # PC PHOTO CELL SENSOR ELECTRIC STRIKE ROUGH IN 46"ES REFER TO SECURITY CONDUIT FOR DOOR ALARMS DETAIL INDOOR SPEAKER 10" WITH ZONE ID. RUN 16/2 STRANDED NON-SHIELDED CABLE FROM EACH SPEAKER. LOOP TO NEXT SPEAKER IN ZONE AND THEN RUN TO THE ZONES VOLUME CONTROL. VOLUME CONTROL WITH ZONE ID. RUN 16/2 NON SHIELDED STRANDED CABLE FROM VOLUME CONTROL BACK TO IDF1/AV ROOM. OUTDOOR SPEAKER WITH ZONE ID. RUN 16/2 STRANDED NON-SHIELDED CABLE FROM EACH SPEAKER. LOOP TO NEXT SPEAKER IN ZONE AND THEN RUN TO THE ZONES VOLUME CONTROL. VC 46" SINGLE GANG WEATHERPROOF BOX WITH 3/4" CONDUIT TO ACCESSIBLE CEILING SPACE SINGLE GANG JUNCTION BOX 3/4" SMURF TUBE OR CONDUIT TO ACCESSIBLE CEILING SPACE WALL MOUNTED ON MULLION S S S S (wall) (ceiling) (wall) (ceiling) Engi n ngir LLC8200 PEACHTREE AVE. ROCKFORD, MI 49341 P. 616-340-9627 P:\2018\2018388 Aloft-Element Carmel\Working Drawings\E500 -Carmel DB.dwg, 5/26/2020 10:03:25 AM, cll09/28/20 M 3M OL OLOL H 1A 2A A FU FU FU FUSED CONTROL TRANSFORMER ON 480V, 230V, OR 208V SYSTEMS REWIRE FACTORY INSTALLED SELECT SWITCH TO PLACE PROTECTIVE DEVECES IN CONTROL CIRCUIT AS SHOWN PUSH TO TEST AUXILLARY CONTACTS TO RESPECTIVE INTERLOCKS "HAND-OFF-AUTO" SELECT SWITCH AND PILOT LIGHT WITH PUSH TO TEST IN COVER LOCATE STARTER WHERE SHOWN ON PLAN CONTROL WIRING EXTENSIONS BY MECHANICAL CONTRACTOR IN ACCORDANCE WITH TEMPERATURE CONTROL SPECIFICATIONS FREEZE STAT DUCT DETECTOR N M N.T.S. BUSSMAN SSU PLUGFUSE & DISC. BY E.C. AT MOTOR L1 N EXHAUST FAN N.T.S. A-1 E501 1-3 HOUR SPRING WOUND TIMER FURNISHED AND INSTALLED BY E.C. B-2 E501 FOR BIDDING PURPOSES ONLY. VERIFY ALL BREAKER, WIRE SIZE, AND WIRING REQUIREMENTS WITH APPROVED UNIT SHOP DRAWINGS. DISCONNECT SWITCH BY ELECTRICAL CONTRACTOR ABOVE ACCESSIBLE CEILING SPACE WITH WIRE TO PANEL AS NOTED ON FLOOR PLAN. 7#10 3/4"C INTERCONNECTING OUTDOOR UNIT TO INDOOR UNIT. NEMA 3R DISCONNECT BY ELECTRICAL CONTRACTOR. REFER TO ELECTRICAL AND MECHANICAL PLANS FOR EXACT LOCATION. ROOF MOUNTED OUTLET AS REQUIRED BY CODE. CIRCUIT TO NEAREST AVAILABLE CIRCUIT. FINISHED FLOOR F F W.P. CEILING GRID ROOF DECK N.T.S. C C A.C.C.U. NEMA 3R FDS & FUSES BY E.C. 4#14 LOW VOLTAGE CONTROL WIRES TO TEMPERATURE CONTROL MODULE L1 L2 L3 N.T.S. A-3 E501 L1 L2 2#14 LOW VOLTAGE CONTROL WIRES TO TEMPERATURE CONTROL MODULE NEMA 3R FDS & FUSES BY E.C. A.C.C.U. N.T.S. B-3 E501 REFER TO EF-8 ON FIRST FLOOR. REVERSE ACTING THERMOSTAT PROVIDED BY M.C., WIRED BY ELECTRICAL CONTRACTOR. LOCATE WHERE SHOWN ON PLANS L1 N BUSSMAN SSU PLUGFUSE & DISCONNECT BY E.C. AT MOTOR. EXHAUST FANT C N.T.S. B-1 E501 FRONT REAR SIDE OF PLATE FRONT REAR SIDE OF PLATE BPA-15LP2-5 LABEL CKT. NO. OF EACH DEVICE ON REAR SIDE OF COVER PLATE. USE PERMANANT MARKER PEN, BRADY MARKING SYSTEM OR OTHER METHOD APPROVED BY THE ENGINEER JUNCTION BOXES (EXPOSED OR CONCEALED ABOVE ACCESSIBLE CEILING) LABEL COVERS WITH CKT.'S CONTAINED WITHIN. USE PERMANANT MARKER PEN OR OTHER APPROVED METHOD. FOR J.B.'S CONTAINING OTHER THAN POWER OR LIGHTING CKT.'S LABEL COVERS INDICATING SYSTEM TYPE AND ZONES. LABEL EXAMPLES: ----------- "FIRE ALARM-ZONES 2&3" "P.A. ZONES 4,5,&6" "DATA CIRCUITS A&B" "EXIT SIGNS-EMI&2" "EMERG. CKTS. BPEM-3,4" CKT.S LP4-13,15,17 DUPLEX RECEPTACLE PLATESTANDARD TOGGLE SWITCH PLATE N.T.S. ENTER AT STRIKE SIDE OF DOOR. PROVIDE STYRAFOAM FILLER FOR FILLED FRAMES. 1/2"CONDUIT OR ELECTRICAL NON-METALLIC TUBING WITH PULL STRING TO ACCESSIBLE CEILING SPACE. COORDINATE WITH LINTEL WHERE NECESSARY. HINGE PLATE STRIKE PLATE N.T.S. DUCT DETECTOR. (TYPICAL) 2#14 & 1#18 TWISTED SHIELDED PAIR TO FIRE ALARM PANEL. REMOTE DUCT DETECTOR TEST SWITCH (TYPICAL) R.T.U. CONTROL PANEL SUPPLY AIR DUCT 9#16 LOW VOLTAGE IN 1/2" CONDUIT. 7#18,1/2"C. (TYPICAL) RETURN AIR DUCT 4#12,1/2"C. (TYPICAL) NEMA 3R DISC. SW. BY E.C. R.T.U. W.P. ROOF MOUNTED OUTLET AS REQUIRED BY CODE. CIRCUIT TO NEAREST AVAILABLE CIRCUIT. T NOTES: 1. FOR BIDDING ONLY. ACTUAL WIRING PER APPROVED MANUFACTURER'S SHOP DRAWINGS. 2. REFER TO ELECTRICAL PLANS AND MECHANICAL SCHEDULES FOR DUCT DETECTOR REQUIREMENTS. D RT D RT N.T.S. B-4 E501 Engi n ngir LLC8200 PEACHTREE AVE. ROCKFORD, MI 49341 P. 616-340-9627 P:\2018\2018388 Aloft-Element Carmel\Working Drawings\E501 -Carmel DB.dwg, 5/26/2020 10:10:09 AM, cll09/28/20 Engi n ngir LLC8200 PEACHTREE AVE. ROCKFORD, MI 49341 P. 616-340-9627 P:\2018\2018388 Aloft-Element Carmel\Working Drawings\E502 -Carmel DB.dwg, 5/26/2020 10:12:36 AM, cll09/28/20 Engi n ngir LLC8200 PEACHTREE AVE. ROCKFORD, MI 49341 P. 616-340-9627 P:\2018\2018388 Aloft-Element Carmel\Working Drawings\E503 -Carmel DB.dwg, 5/26/2020 10:13:07 AM, cll09/28/20 Engi n ngir LLC8200 PEACHTREE AVE. ROCKFORD, MI 49341 P. 616-340-9627 P:\2018\2018388 Aloft-Element Carmel\Working Drawings\E504 -Carmel DB.dwg, 5/26/2020 10:13:47 AM, cll09/28/20 Engin ngir LLC8200 PEACHTREE AVE. ROCKFORD, MI 49341 P. 616-340-9627 P:\2018\2018388 Aloft-Element Carmel\Working Drawings\E505 -Carmel DB.dwg, 5/26/2020 10:14:18 AM, cll09/28/20 TYPICAL ELEVATOR BASED ON SCHINDLER 3300 TEST AND INSPECTION PANEL PROVIDED WITH ELEV. LOCATED IN HOISTWAY. PROVIDE LOCKABLE NON FUSED DISCONNET (JH1) WITH AUX DRY CONTACT POSITIVELY DRIVEN OPEN WHEN SWITCH IS OPEN, LOCATED IN ELEVATOR SHAFT, NEMA 3R INSPECTION AND TEST PANEL PROVIDED WITH ELEVATOR LOCATED ON 9TH FLOOR. OR AS NOTED ON ARCH PLANS E.C. TO PROVIDE WIRING BETWEEN ELEVATOR COMPONENTS PER ELEVATOR REQUIREMENTS. MOTOR CONTROLLER PROVIDED WITH ELEVATOR IN HOISTWAY FUSEBOX PROVIDED WITH ELEV IN HOISTWAY VFD PROVIDE WITH UNIT IN HOISTWAY 3P30A LOCKABLE FUSIBLE DISCONNECT (JH) OUTSIDE HOISTWAY F ELEV 1 AND 2 TO BE PROGRAMMED SO THAT ONLY ONE ELEVATOR RUNS AT A TIME UNDER EMERGENCY POWER ELEVATOR 3 AND 4 TO BE PROGRAMMED SO THAT ONLY ONE ELEVATOR RUNS AT A TIME UNDER EMERGENCY POWER ELEVATOR 5 TO BE PROGRAMMED TO NOT RUN UNDER EMERGENCY POWER PROVIDE CT CABINET FOR METERING PER UTILITY REQUIREMENTS. METERING CABINET BY UTILITY.M UTILITY FEED UNDERGROUND HIGH VOLTAGE CABLE BY UTILITY. COORDINATED BY EC 277/480V- 3Ø-4W, ONE-LINE DIAGRAM DOMESTIC WATER BOOSTER 3P30 CONTROL PANEL PROVIDE WITH UNIT 600A MLO 'DP1' JOCKEY PUMP 1 1/2HP 3P15 WASHER WASHER WASHER DRYER 3P20 3P20 3P20 3P20 DRYER 3P20 DRYER 3P20 WASHER 3P20 BP-EM1 PANEL LIFE SAFETY ATS-1 3P80A 3P60A SURGE SUPPRESSION ON DEVICE (TVSS) FOR EMERGENCY T T-EM1 45KVA 3P125A NON LIFE SAFETY ATS-2 3P200A 3P30A BPEM3 PANEL SURGE SUPPRESSION ON DEVICE (TVSS) FOR EMERGENCY 3P30A E.C. TO TERMINATE AT TEST & INSPECTION PANEL, REFER TO TYPICAL ELEVATOR BLOCK WIRING DIAGRAM THIS SHEET.. 3P40 3P40 3P40 F ELEV #1 15 HP F ELEV #2 15 HP F ELEV #3 15 HP 225A MLO 'DPE6 3P200 3P80 SCKVA HP 200KW DIESEL LOAD CALCULATION TO BE PROVIDED IN SHOP DRAWING SUBMITTAL. FIRE PUMP 50HP 3P400 JOCKEY PUMP AND FIRE PUMP CONTROLLER AND ATS PROVIDED BY FIRE PROTECTION CONTRACTOR, INSTALLED BY E.C. VERIFY SIZE AND WIRING WITH FIRE SUPPRESSION CONTRACTOR. ATS-3 PROVIDED WITH FIRE PUMP PACKAGE 3P30 3P303P303P30 INTERLOCK WITH PDU-1 CONTROLS 3P30 DUCT HEATER 20KW PDU-1 2HP PDU-1 2HP 3P15 F 3P60A NOTE 1 MAU-4 71.7 MCA 3P60A NEMA 3R 3P110A RE:A2/E5.0 FEED TO MDP1 (9) SETS OF 4-750KCMIL (CU)+500CKMIL G, 5" C BY EC. ST MAU FOR KITCHEN PROVIDE SHUNT TRIP BREAKER AS NOTED BREAKER SIZED FOR 50HP, 363 LOCKED ROTOR AMPS. WIRING SIZED AT 125% OF FLA. VERIFY WITH FINAL FIRE PUMP SIZE. 3P40 80B BOOSTER HEATER 54.2A 3P70 29B-COMBI STEAMER 80.5A 3P100A ST SEE SHEET E601 FOR CONTINUATION SEE SHEET E601 FOR CONTINUATION SEE SHEET E601 FOR CONTINUATION SEE SHEET E601 FOR CONTINUATION SEE SHEET E601 FOR CONTINUATION 77-B DISHWASH 22.3A DRYER 3P20 EF-16 (2) 3P60 EF-13, EF-14, EF-16 SURGE SUPPRESSION ON DEVICE (TVSS) FOR EMERGENCY 3P30 1P20 SITE LIGHTING 3P60A FUSE 40A 3P60A FUSE 40A 3P60A FUSE 40A 3P40 F ELEV #4 15 HP 3P60A FUSE 40A 3P40 F ELEV #5 15 HP 3P60A FUSE 40AF ELEV #1 15 HP GENERAL NOTES: REFER TO WIRE SIZING CHART, COPPER OR ALUMINUM MAY BE UTILIZED AT CONTRACTORS DISCRETION UNLESS NOTED OTHERWISE. COORDINATE ROUTING WITH TRADES ON SITE. PROVIDE HAZARD LABELS PER CODE MEETING ANSI Z535.4 PROVIDE ARC ENERGY REDUCTION FOR MDP PER NEC (1200A OR HIGHER) PANELBOARD MANUFACTURER IS REQUIRED TO TO RUN ARC FLASH CALCULATIONS AND PROVIDE LABELING ON PANELS PER NEC 70 2011 CODE. MANUFACTURER TO PROVIDE COORDINATION STUDY. SURGE PROTECTION TO BE PROVIDED ON ALL EMERGENCY SYSTEMS SWITCHBOARDS AND PANELBOARDS PER NEC 700.8 ALL PANELS OVER 42 BREAKERS SHALL BE VERTICAL SINGLE TUB PANELS WITH 60-84 BREAKERS AS NOTED IN PANEL SCHEDULE. SIDE BY SIDE TUBS NOT PERMITTED UNLESS NOTED OTHERWISE. Engi n ngir LLC8200 PEACHTREE AVE. ROCKFORD, MI 49341 P. 616-340-9627 P:\2018\2018388 Aloft-Element Carmel\Working Drawings\E600 -Carmel DB.dwg, 5/26/2020 10:14:50 AM, cll09/28/20 MAIN SWITCHBOARD "MDP" 480/277V, 3P, 4W, WYE 3P200A PIPING PER NEC, REFER & ALL OTHER METALLIC BARE CU TO WATER BARE CU TO BUILDING STEEL BARE CU "UFER" CONCRETE ENCASED GROUND ISOLATION BARRIER PER NEC 695.3(A)(1) 3P80A 3P600A TO GROUNDING DETAIL FOR SIZES 3P800A F 3P100A NOTE 1 MAU-1 52 MCA 3P100A NEMA 3R MAU PROVIDED WITH NEMA 3R DISCONNECT. RE:A2/E5.0 3P400A 3P400 BPK1 PANEL SDP1A 3P1400A 3P200 BP1B PANEL BP1A PANEL 3P150 BPP PANEL 3P100 2P100 BPG2 PANEL (4) 2P100A FEEDS T T-1 500 KVA BP1C PANEL 3P225 BPK2 PANEL BPK2S PANEL 3P200ST SHUNT TRIP PANEL FOR HOOD LOADS INDIVIDUAL SHUNT TRIP BREAKERS OR CONTACTOR MAY BE USED 3P600 3P800A 3P200A TO DP2B TO DP2A TO DP6A 3P3500A GROUND FAULT PROTECTED NEMA 3R BY EC 3P1200A 3P400A BREAKER SIZED FOR 50HP, 363 LOCKED ROTOR AMPS. WIRING SIZED AT 125% OF FLA. VERIFY WITH FINAL FIRE PUMP SIZE. SEE SHEET E600 FOR CONTINUATION SEE SHEET E600 FOR CONTINUATION SEE SHEET E600 FOR CONTINUATION SEE SHEET E600 FOR CONTINUATION SEE SHEET E600 FOR CONTINUATION SEE SHEET E602 FOR CONTINUATION SEE SHEET E602 FOR CONTINUATION SEE SHEET E602 FOR CONTINUATION GENERAL NOTES: REFER TO WIRE SIZING CHART, COPPER OR ALUMINUM MAY BE UTILIZED AT CONTRACTORS DISCRETION UNLESS NOTED OTHERWISE. COORDINATE ROUTING WITH TRADES ON SITE. PROVIDE HAZARD LABELS PER CODE MEETING ANSI Z535.4 PROVIDE ARC ENERGY REDUCTION FOR MDP PER NEC (1200A OR HIGHER) PANELBOARD MANUFACTURER IS REQUIRED TO TO RUN ARC FLASH CALCULATIONS AND PROVIDE LABELING ON PANELS PER NEC 70 2011 CODE. MANUFACTURER TO PROVIDE COORDINATION STUDY. SURGE PROTECTION TO BE PROVIDED ON ALL EMERGENCY SYSTEMS SWITCHBOARDS AND PANELBOARDS PER NEC 700.8 ALL PANELS OVER 42 BREAKERS SHALL BE VERTICAL SINGLE TUB PANELS WITH 60-84 BREAKERS AS NOTED IN PANEL SCHEDULE. SIDE BY SIDE TUBS NOT PERMITTED UNLESS NOTED OTHERWISE. 3P70A BPK1S PANEL 3P200ST SHUNT TRIP PANEL FOR HOOD LOADS INDIVIDUAL SHUNT TRIP BREAKERS OR CONTACTOR MAY BE USED TO DPEM1 TO FIRE PUMP TO DPE6 TO DP1 Engi n ngir LLC8200 PEACHTREE AVE. ROCKFORD, MI 49341 P. 616-340-9627 P:\2018\2018388 Aloft-Element Carmel\Working Drawings\E601 -Carmel DB.dwg, 5/26/2020 10:15:22 AM, cll09/28/20 F 3P60A NOTE 1 MAU-2 52 MCA 3P60A NEMA 3R 'SDP2B' 2P100 BPG2 PANEL (15) 2P100A FEEDS EACH TO PANEL IN LIVING UNIT REFER TO ENLARGED PLANS FOR EXACT LOCATION OF PANEL TYPICAL 'SDP3B' BP3B PANEL BP3A PANEL T T-2A 112 KVA DP2B 3P400A T T2B 225 KVA T T3B 150 KVA TO MDP 1200A MAIN LUG 3P500A 3P800A F RTU-1 18 MCA F RTU-2 18 MCA F RTU-3 18 MCA F RTU-4 37 MCA F RTU-5 37 MCA 3P200A 'SDP4B' 2P100 BPG2 PANEL (12) 2P100A FEEDS EACH TO PANEL IN LIVING UNIT T T4B 150 KVA 3P500A 3P200A 3P200A 3P200A 'SDP5B' T T5B 150 KVA 3P500A 'SDP6B' T T6B 150 KVA RTU PROVIDED WITH NEMA 3R DISCONNECT AND RECEPTACLE. E.C. TO POWER AS NOTED. 3P225 BP4C PANEL 2P100 BPG2 PANEL (12) 2P100A FEEDS EACH TO PANEL IN LIVING UNIT 3P225 BP5C PANEL 2P100 BPG2 PANEL (13) 2P100A FEEDS EACH TO PANEL IN LIVING UNIT RE:A2/E5.0 3P200A 800A MAIN LUG TO MDP DP2A 3P200A T T-3A 112 KVA T T-4A 112 KVA T T-5A 112 KVA 3P200A 3P200A 277/480V- 3Ø-4W, ONE-LINE DIAGRAM - ELEMENT TOWER 277/480V- 3Ø-4W, ONE-LINE DIAGRAM - ALOFT TOWER F 3P60A NOTE 1 MAU-1 71.7 MCA 3P60A NEMA 3R RE:A2/E5.0 2P125 BPG3 PANEL 2P125 BPG3 PANEL SEE SHEET E601 FOR CONTINUATION SEE SHEET E601 FOR CONTINUATION SEE SHEET E601 FOR CONTINUATION 3P500A 2P100 BPG2 PANEL (12) 2P100A FEEDS EACH TO PANEL IN LIVING UNIT 3P225 BP6C PANEL 2P125 BPG3 PANEL BP2B PANEL BP2A PANEL GENERAL NOTES: REFER TO WIRE SIZING CHART, COPPER OR ALUMINUM MAY BE UTILIZED AT CONTRACTORS DISCRETION UNLESS NOTED OTHERWISE. COORDINATE ROUTING WITH TRADES ON SITE. PROVIDE HAZARD LABELS PER CODE MEETING ANSI Z535.4 PROVIDE ARC ENERGY REDUCTION FOR MDP PER NEC (1200A OR HIGHER) PANELBOARD MANUFACTURER IS REQUIRED TO TO RUN ARC FLASH CALCULATIONS AND PROVIDE LABELING ON PANELS PER NEC 70 2011 CODE. MANUFACTURER TO PROVIDE COORDINATION STUDY. SURGE PROTECTION TO BE PROVIDED ON ALL EMERGENCY SYSTEMS SWITCHBOARDS AND PANELBOARDS PER NEC 700.8 ALL PANELS OVER 42 BREAKERS SHALL BE VERTICAL SINGLE TUB PANELS WITH 60-84 BREAKERS AS NOTED IN PANEL SCHEDULE. SIDE BY SIDE TUBS NOT PERMITTED UNLESS NOTED OTHERWISE. 'DP6A' 3P70 3P110 3P200A BP6B PANEL BP6A PANEL T T-6A 112 KVA 400A MLO 3P30A 3P50A 3P50A 3P30A 3P30A 3P125 BP3C PANEL 3P150 BP2C PANEL 3P225 BP2D PANEL BP5B PANEL BP5A PANEL BP4B PANEL BP4A PANEL F 3P400A F 3P400A F 3P400A F 3P400A F 3P400A F 3P30A NOTE 1 EF-12 3.25 MCA 3P30A NEMA 3R RE:A2/E5.0 3P20 Engi n ngir LLC8200 PEACHTREE AVE. ROCKFORD, MI 49341 P. 616-340-9627 P:\2018\2018388 Aloft-Element Carmel\Working Drawings\E602 -Carmel DB.dwg, 5/26/2020 10:15:55 AM, cll09/28/20 CONCRETE-ENCASED ELECTRODEGROUND ROD NO. 6 COPPER MINIMUM BUILDING STEEL NEUTRAL BUSS BONDING JUMPER PROVIDED BY E.C. IF NOT PROVIDED WITH EQUIPMENT EQUIPMENT GROUNDING BUS UNDERGROUND WATER PIPE. PROVIDE FULL SIZE JUMPER AROUND WATER METER AS REQUIRED. #4 BARE COPPER MINIMUM GROUND RING. MINIMUM OF 20' OF #2 BARE COPPER. NOT LARGER THAN CONDUCTOR USED FOR GROUND RING5/8"x8' MINIMUM REFER TO NATIONAL ELECTRIC CODE FOR ALL REQUIREMENTS FOR A PROPERLY GROUNDED SYSTEM. ALL GROUND CONDUCTORS TO BE SIZED ACCORDING TO ART. 250 OF THE NATIONAL ELECTRIC CODE. 2. 1. N.T.S. SERVICE DISCONNECT OR SERVICE EQUIPMENT 250-118 PER SEC SERVICE EQUIPMENT GEN NOT A SEPARATELY EQUIPMENT GROUNDING CONDUCTOR N DERIVED SYSTEM N LOAD TRANSFER SWITCH 3-POLE GN NATIONAL ELECTRIC CODE. GROUNDED SYSTEM. 1. REFER TO NATIONAL ELECTRIC CODE FOR ALL REQUIREMENTS FOR A PROPERLY 2. ALL GROUND CONDUCTORS TO BE SIZED ACCORDING TO ART. 250 OF THE N.T.S. ELECTRICAL PANEL GROUNDING ELECTRODE CONDUCTOR 'A' EQUIPMENT GROUNDING CONDUCTOR 'B' DRY-TYPE TRANSFORMER GROUNDING ELECTRODE NEARBY, PREFERABLY THE STRUCTURAL METAL MAIN BONDING JUMPER 'A' B A NEUTRAL C 120 V N 208Y/ G 480 V INSULATED NEUTRAL TERMINAL 1. REFER TO NATIONAL ELECTRIC CODE FOR ALL REQUIREMENTS FOR A PROPERLY GROUNDED SYSTEM. 2. ALL GROUND CONDUCTORS TO BE SIZED ACCORDING TO ART. 250 OF THE NATIONAL ELECTRIC CODE. 3. TRANSFORMER GRND ELECTRODE (A) EQUIPMENT GRND (B) (15 KVA) #6 COPPER #8 COPPER (30 KVA) #6 COPPER #8 COPPER (45 KVA) #6 COPPER #8 COPPER (75 KVA) #2 COPPER #8 COPPER (112.5 KVA) #2 COPPER #6 COPPER (150 KVA) #1/0 COPPER #6 COPPER (225 KVA) #2/0 COPPER #4 COPPER (300 KVA) #3/0 COPPER #3 COPPER N.T.S. Engi n ngir LLC8200 PEACHTREE AVE. ROCKFORD, MI 49341 P. 616-340-9627 P:\2018\2018388 Aloft-Element Carmel\Working Drawings\E603 -Carmel DB.dwg, 5/26/2020 10:16:26 AM, cll09/28/20 Engi n ngir LLC8200 PEACHTREE AVE. ROCKFORD, MI 49341 P. 616-340-9627 P:\2018\2018388 Aloft-Element Carmel\Working Drawings\E604 -Carmel DB.dwg, 5/26/2020 10:17:22 AM, cll09/28/20 Engi n ngir LLC8200 PEACHTREE AVE. ROCKFORD, MI 49341 P. 616-340-9627 P:\2018\2018388 Aloft-Element Carmel\Working Drawings\E605 -Carmel DB.dwg, 5/26/2020 10:18:06 AM, cll09/28/20 Engi n ngir LLC8200 PEACHTREE AVE. ROCKFORD, MI 49341 P. 616-340-9627 P:\2018\2018388 Aloft-Element Carmel\Working Drawings\E606 -Carmel DB.dwg, 5/26/2020 10:18:43 AM, cll09/28/20 Engi n ngir LLC8200 PEACHTREE AVE. ROCKFORD, MI 49341 P. 616-340-9627 P:\2018\2018388 Aloft-Element Carmel\Working Drawings\E607 -Carmel DB.dwg, 5/26/2020 10:19:30 AM, cll09/28/20 Engi n ngir LLC8200 PEACHTREE AVE. ROCKFORD, MI 49341 P. 616-340-9627 P:\2018\2018388 Aloft-Element Carmel\Working Drawings\E608 -Carmel DB.dwg, 5/26/2020 10:20:04 AM, cll09/28/20 Engi n ngir LLC8200 PEACHTREE AVE. ROCKFORD, MI 49341 P. 616-340-9627 P:\2018\2018388 Aloft-Element Carmel\Working Drawings\E609 -Carmel DB.dwg, 5/26/2020 10:20:46 AM, cll09/28/20 Engi n ngir LLC8200 PEACHTREE AVE. ROCKFORD, MI 49341 P. 616-340-9627 P:\2018\2018388 Aloft-Element Carmel\Working Drawings\E610 -Carmel DB.dwg, 5/26/2020 10:21:18 AM, cll09/28/20 Engi n ngir LLC8200 PEACHTREE AVE. ROCKFORD, MI 49341 P. 616-340-9627 P:\2018\2018388 Aloft-Element Carmel\Working Drawings\E611 -Carmel DB.dwg, 5/26/2020 10:21:56 AM, cll09/28/20 6th Floor 5th Floor 4th Floor 3rd Floor 2nd Floor 1st Floor Roof N.T.S. A ET-200 Two (2) 4" continuous conduits for Telco services DEMARC to MDF room coordinate with low voltage plans. MDF IDF2(ELEMENT) N.T.S. B ET-200 GUESTROOM LEVEL 2 ROOF LEVEL 7 RF AMPLIFIER (FFRT)-TYPICAL 4" SLEEVE AT EACH FLOOR GUESTROOM LEVEL 5 GUESTROOM LEVEL 6 CONTRACTOR SHALL PROVIDE PRICING TO PROVIDE AN EMERGENCY RESPONDER RADIO COVERAGE (EERC) SYSTEM IN ACCORDANCE WITH THE REQUIREMENTS OF THE INTERNATIONAL FIRE CODE (IFC) 510 FOR HOTEL BUILDING. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL LABOR AND MATERIALS FOR THE DESIGN, PERMITTING AND INSTALLATION OF THE ERRC SYSTEM. CONTRACTOR MUST HAVE THE MINIMUM QUALIFICATIONS AS OUTLINED IN THE IFC SECTION 510.5.2. THE SYSTEM SHALL MEET THE TECHNICAL REQUIREMENTS AND DESIGN PARAMETERS INDICATED IN THE IFC 510.4. ONCE THE SYSTEM INSTALLATION HAS BEEN COMPLETED, A "LETTER OF CERTIFICATION" SHALL BE PROVIDED TO THE FIRE MARSHAL'S OFFICE INDICATING COMPLIANCE WITH THE TESTING PROVISION OF IFC 510.5.3. ALL WORK AND MATERIALS SHALL CONFORM TO ALL FEDERAL, STATE AND LOCAL CODES AND REGULATION GOVERNING THE INSTALLATION., WHERE REQUIRED VERTICAL ANTENNA WIRE TO RUN IN 4" LOW VOLTAGE CONDUITS SHOWN ON RISER DIAGRAM THIS SHEET. EMERGENCY POWER IS PROVIDED FOR AMPLIFIER UNIT IN IDF OR MDF ROOMS DIAGRAM IS REPRESENTATIVE OF TYPICAL SYSTEM AND IS NOT FINALIZED FOR THIS PROJECT. FFRT ANTENNAE GENERAL NOTES: FIRE FIGHTER RADIO TRANSMITTER (FFRT). QUANTITY AND LOCATIONS ARE APPROXIMATE, CONTRACTOR(S) TO COORDINATE WITH SIGNAL SURVEY. SIGNAL SURVEY BY WIRELESS COMMUNICATIONS VENDOR. FOR EXTERIOR OUTLETS, PROVIDE WEATHERPROOF BOX. PROVIDE (2) FIRE RATED COAXIAL CABLES TO RADIO TRANSMITTER AMPLIFIER. FORWARD SHOP DRAWINGS/PRODUCT DATA TO FIRE DEPARTMENT FOR REVIEW AND COMMENT BEFORE CONSTRUCTION. CONTRACTOR TO VERIFY FINAL ANTENNAE PLACEMENT AFTER FLOORS, WALLS AND CEILINGS ARE INSTALLED. PROVIDE ADDITIONAL AMPLIFIER AND ASSOCIATED EQUIPMENT AS REQUIRED. 1. GUESTROOM LEVEL 4 LOBBY LEVEL 1 GUESTROOM LEVEL 3 Three (3) 2" Conduits with weather heads to MDF IDF4(ELEMENT) IDF1(Aloft) IDF3(Aloft) Four (4) 4" Conduit Stubs in IDF/ELEC Stacked roomsFour (4) 4" Conduit Stubs in IDF/ELEC Stacked rooms Engi n ngir LLC8200 PEACHTREE AVE. ROCKFORD, MI 49341 P. 616-340-9627 P:\2018\2018388 Aloft-Element Carmel\Working Drawings\E700 -Carmel DB.dwg, 5/26/2020 10:01:22 AM, cll09/28/20