HomeMy WebLinkAboutA-101.5A. ALL DIMENSIONS TO BE VERIFIED IN FIELD PRIOR TO CONSTRUCTION. NOTIFY
ARCHITECT OF ALL DISCREPANCIES PRIOR TO STARTING WORK
B. ALL DIMENSIONS ARE FACE OF MASONRY, POURED/PRECAST CONCRETE, OR
FACE OF STUD (WOOD OR METAL, UNO)
C. ALL DIMENSIONED STOREFRONT SYSTEMS ARE NOMINAL ROUGH OPENINGS,
UNO
D. ALL RESIDENTIAL UNITS TO BE ACCESSIBILITY TYPE B, UNO ( ONLY UNITS 202,
205, & 206 TO BE TYPE A)
E. ALL INTERIOR PARTITIONS TO BE TYPE 6A UNLESS NOTED OTHERWISE. REFER
TO SHEET A-002 FOR PARTITION DETAILS/SCHEDULE
F. ALL INTERIOR DOOR FRAMES SHALL BE LOCATED A DISTANCE OF FOUR
INCHES FROM THROAT RETURN TO THE CLOSEST ADJACENT PERPENDICULAR
PARTITION, UNO
G. PROVIDE SOLID BLOCKING/BACKING IN-WALL CAVITIES AT ALL WALL MOUNTED
CASEWORK, FIXTURES, EQUIPMENT, AND SHELVING. REFER TO TYPICAL
PARITION AND INTERIOR ELEVATIONS FOR ADDITIONAL INFORMATION
H. REFER TO MEP AND FIRE PROTECTION DRAWINGS FOR MOUNTING HEIGHTS
OF SWITCHES, OUTLETS, ALARMS AND ALL SURFACE MOUNTED COMPONENTS.
I. ALL MASONRY DIMENSIONS ARE NOMINAL, UNO
J. PROVIDE 24" X 24" MIN FIRE RATED ACCESS PANELS TO ALL CHASES AT EVERY
FLOOR LEVEL FOR ACCESSIBILITY GREASE PIPE(S) AND MECHANICAL DUCTS.
K. ALL DOORS FROM CORRIDOR(S) TO STOR (STORAGE) & MECH ELECT
(MECHANICAL ELECTRICAL) ROOMS ARE TO BE CENTERED ON THE INTERIOR
OF THE SPACE, UNO
L. REFER TO SHEET A-601/A-602 FOR DOOR/WINDOW SCHEDULE, TYPES, &
DETAILS
M. REFER TO INTERIOR DESIGN DRAWINGS FOR ALL INTERIOR FINISH PLANS,
SPECIFICATIONS, & DETAILS
N. REFER TO STRUCTURAL DRAWINGS FOR GROUND FLOOR CONCRETE SLAB
LEAVE OUT LOCATIONS, TYP
O. DRAFT STOPS REQUIRED IN THE FLOOR ASSEMBLIES IN LINE WITH EACH
DWELLING UNIT SEPERATION. REQUIRED IN ATTIC TO SEPERATE SPACE
ABOVE EVERY TWO DWELLING UNITS OR 3000SF, WHICHEVER IS LESS
P. ALL RESIDENTIAL UNITS ON FLOORS 3&4 TO RECEIVE 1-1/8" GYPCRETE
TOPPING ON 3/8" ACOUSTIMAT OR SIMILAR ON TOP OF WOOD DECK, TYP
Q. CORRIDORS & PUBLIC INTERIOR SPACES ON FLOORS 3&4 TO RECEIVE 1-1/2"
GYPCRETE TOPPING ONLY ON TOP OF WOOD DECK, TYP
R. ALL RESIDENTIAL UNITS ON FLOOR 5 ONLY TO RECEIVE 2-1/8" GYPCRETE
TOPPING ON 3/8" ACOUSTIMAT OR SIMILAR ON TOP OF WOOD DECK, TYP
S. CORRIDORS & PUBLIC INTERIOR SPACES ON FLOOR 5 ONLY TO RECEIVE 2-1/2"
GYPCRETE TOPPING ONLY ONY TOP OF WOOD DECK, TYP
A-202
D2
A-202
A2
A-201
D1
A
A
1717
A1
A-301
A1
A-301
RAMP (DOWN)
NORTH
STAIR
N1
EAST
STAIR
E1
ELEV
1
ELEV
2
281 SF
LOBBY
150L
98 SF
MISC
150M3
55 SF
MISC
150M2
103 SF
MISC
150M1
A2
A-301
A2
A-301D
D E
1313
B1
A-302
B1
A-302
B2
A-302
B2
A-302
D2
A-314
16
B
1
2
4.
11
G P S T
1515
A-203
A1
3
5
6
9
10
12
1414
F H J K M N RAA
AC
AD
4Bm
4Bm
4Bm
11' - 4 7/8"2' - 0" (CLEAR)7 5/8"15' - 4 1/2"(CLEAR)8' - 6"7 5/8"(CLEAR)8' - 6"3' - 3 1/2"7 5/8" (CLEAR)7' - 6 7/8"9' - 8 1/8"5' - 4 3/4"5' - 4 3/4" 9' - 3 1/8"8' - 2 1/4"C
C D.9
L
7
8
13.113.1
A1
A-311
A2
A-311
A4
A-311
B2
A-312
B3
A-312
B4
A-312
C1
A-313
C2
A-313
C3
A-313
C4
A-313
D1
A-314
D3
A-314
A3
A-311
E1
A-315
B1
A-3126Sm
6Sm
6Bm
12.9
E.1
E2
A-315
A-411
A2
A-412
A2
6Bm6Bm
4Am
14' - 0" (RAMP)9' - 0 7/8"5' - 0"18' - 0"(20'-0" MIN)22' - 8 1/2"18' - 0"18' - 0"
(20'-0" MIN)
21' - 9" 18' - 0"18' - 0"(20'-0" MIN)22' - 8 1/2"18' - 0"(TYP WIDTH)
9' - 0"(TYP STALL DEPTH)18' - 0"ONE-WAY
ONE-WAY ONE-WAY ONE-WAY TWO-WAY
(RAMP ONLY) ONE-WAY ONE-WAY (20'-0" MIN)21' - 11 5/8"18' - 0"5' - 0"DWGS)(SEE PC5' - 9"5' - 9"4Am
4Am
4Am
4Am
2' - 0"106
106
106106
13.513.5
A-414
A3
A-414
A2
19424 SF
TWO-STORY OPEN
PUBLIC PARKING
GARAGE
P150G
A-414
A1
SF9
SF19
E4
A-315
D.5
D.5
AB
8' - 0" 14' - 6 1/2"33' - 5 1/2"
56' - 0"5' - 9"
(SEE PRECAST DRAWINGS)
156' - 9"
34' - 0"104' - 8"27' - 4" 2' - 0"
213' - 5 3/8"2' - 0"27' - 4"104' - 8"34' - 0"213' - 5 3/8"CL
CL
12' - 4"12' - 4"8' - 0"14' - 6 1/2"33' - 5 1/2"56' - 0"5' - 9"(SEE PRECAST DRAWINGS)146' - 1"121121
14' - 0"17' - 2" 17' - 2"
1 4 ' - 0 "
A-323
A1
A-323
A2161.5°1 6 1 .5 °116.5°116.5°
A-323
A3
A-322
C1 A-322
C2
116 116
116
116
116
116
119119119119
135.0°135.0°(RAMP WIDTH)25' - 0"18' - 0"5' - 9"
111' - 4 1/2"111' - 4 1/2"5' - 6" 16' - 8 7/8"16' - 8 7/8"5' - 6"23' - 10 3/8"18' - 2 1/2"150M1
150M2
150M3150L
A-413
A3
Sim
130130
*REFER TO CIVIL DRAWINGS
FOR OFFICIAL PARKING
LAYOUT AND DETAILS
COMPACT
7' - 10"COMPACT7' - 10"INDICATES CEILING/PLENUM SPACE TO FLOOR LEVEL BELOW
INDICATES NON-DRIVING CIRCULATION AREA OF PARKING
LOT/RAMP/STAIR CONNECTOR AREAS
INDICATES APPROXIMATE TYPICAL PARKING STALL, SEE CIVIL
ARCHITECTURE ENGINEERING GEOSPATIAL│ │
333 NORTH ALABAMA STREET
SUITE 200
INDIANAPOLIS, IN 46204
317.299.7500
SHEET KEYNOTES:
LEGEND:
GENERAL NOTES:ISSUANCE SCHEDULE SHEET NAME:
PROJECT NO:
DATE ISSUED:
NOT FOR
CONSTRUCTION
NUMBER DATE DESCRIPTION SHEET NO:
DRAWN BY:
CHECKED BY:
PRELIMINARY
SUBMITTAL
BIM 360://NOVO Development_1215 Rangeline-Indy/A_1215 Rangline_R20.rvt6/24/2022 11:14:26 AMUPPER PARKING FLOOR
PLAN
A-101.5
RH
RH
081948
06/24/22PROSCENIUM PHASE II (1215)NOVO DEVELOPMENT GROUP1215 RANGELINE RDCARMEL, IN 46032NEW MIXED USE MULTI-FAMILY PROJECT24'16'8'4'0
1/8"=1'-0"
GRAPHIC SCALE
PLAN NORTH
1/8" = 1'-0"
SECOND FLOOR PLAN (P)A1
106 POLE MOUNTED LIGHT FIXTURE, SEE ELECT DWGS
116 INDICATES AREA OF FIRE-RATED VERTICAL CHASE FROM GROUND FLOOR TO
ROOF ABOVE
119 PRECAST CONCRETE OPEN PARKING GARAGE, SEE PC DWGS
121 INDICATES AREA OF TYPICAL PARKING STALL, SEE CIVIL DWGS
130 PROVIDE GALVANIZED LOOP/WAVE STYLE BIKE RACK WITH CONCRETE
MOUNTING HARDWARE OR APPROVED EQUAL (10 BIKE CAPACITY MIN AT THIS
AREA)