HomeMy WebLinkAboutA-101.5A. ALL DIMENSIONS TO BE VERIFIED IN FIELD PRIOR TO CONSTRUCTION. NOTIFY ARCHITECT OF ALL DISCREPANCIES PRIOR TO STARTING WORK B. ALL DIMENSIONS ARE FACE OF MASONRY, POURED/PRECAST CONCRETE, OR FACE OF STUD (WOOD OR METAL, UNO) C. ALL DIMENSIONED STOREFRONT SYSTEMS ARE NOMINAL ROUGH OPENINGS, UNO D. ALL RESIDENTIAL UNITS TO BE ACCESSIBILITY TYPE B, UNO ( ONLY UNITS 202, 205, & 206 TO BE TYPE A) E. ALL INTERIOR PARTITIONS TO BE TYPE 6A UNLESS NOTED OTHERWISE. REFER TO SHEET A-002 FOR PARTITION DETAILS/SCHEDULE F. ALL INTERIOR DOOR FRAMES SHALL BE LOCATED A DISTANCE OF FOUR INCHES FROM THROAT RETURN TO THE CLOSEST ADJACENT PERPENDICULAR PARTITION, UNO G. PROVIDE SOLID BLOCKING/BACKING IN-WALL CAVITIES AT ALL WALL MOUNTED CASEWORK, FIXTURES, EQUIPMENT, AND SHELVING. REFER TO TYPICAL PARITION AND INTERIOR ELEVATIONS FOR ADDITIONAL INFORMATION H. REFER TO MEP AND FIRE PROTECTION DRAWINGS FOR MOUNTING HEIGHTS OF SWITCHES, OUTLETS, ALARMS AND ALL SURFACE MOUNTED COMPONENTS. I. ALL MASONRY DIMENSIONS ARE NOMINAL, UNO J. PROVIDE 24" X 24" MIN FIRE RATED ACCESS PANELS TO ALL CHASES AT EVERY FLOOR LEVEL FOR ACCESSIBILITY GREASE PIPE(S) AND MECHANICAL DUCTS. K. ALL DOORS FROM CORRIDOR(S) TO STOR (STORAGE) & MECH ELECT (MECHANICAL ELECTRICAL) ROOMS ARE TO BE CENTERED ON THE INTERIOR OF THE SPACE, UNO L. REFER TO SHEET A-601/A-602 FOR DOOR/WINDOW SCHEDULE, TYPES, & DETAILS M. REFER TO INTERIOR DESIGN DRAWINGS FOR ALL INTERIOR FINISH PLANS, SPECIFICATIONS, & DETAILS N. REFER TO STRUCTURAL DRAWINGS FOR GROUND FLOOR CONCRETE SLAB LEAVE OUT LOCATIONS, TYP O. DRAFT STOPS REQUIRED IN THE FLOOR ASSEMBLIES IN LINE WITH EACH DWELLING UNIT SEPERATION. REQUIRED IN ATTIC TO SEPERATE SPACE ABOVE EVERY TWO DWELLING UNITS OR 3000SF, WHICHEVER IS LESS P. ALL RESIDENTIAL UNITS ON FLOORS 3&4 TO RECEIVE 1-1/8" GYPCRETE TOPPING ON 3/8" ACOUSTIMAT OR SIMILAR ON TOP OF WOOD DECK, TYP Q. CORRIDORS & PUBLIC INTERIOR SPACES ON FLOORS 3&4 TO RECEIVE 1-1/2" GYPCRETE TOPPING ONLY ON TOP OF WOOD DECK, TYP R. ALL RESIDENTIAL UNITS ON FLOOR 5 ONLY TO RECEIVE 2-1/8" GYPCRETE TOPPING ON 3/8" ACOUSTIMAT OR SIMILAR ON TOP OF WOOD DECK, TYP S. CORRIDORS & PUBLIC INTERIOR SPACES ON FLOOR 5 ONLY TO RECEIVE 2-1/2" GYPCRETE TOPPING ONLY ONY TOP OF WOOD DECK, TYP A-202 D2 A-202 A2 A-201 D1 A A 1717 A1 A-301 A1 A-301 RAMP (DOWN) NORTH STAIR N1 EAST STAIR E1 ELEV 1 ELEV 2 281 SF LOBBY 150L 98 SF MISC 150M3 55 SF MISC 150M2 103 SF MISC 150M1 A2 A-301 A2 A-301D D E 1313 B1 A-302 B1 A-302 B2 A-302 B2 A-302 D2 A-314 16 B 1 2 4. 11 G P S T 1515 A-203 A1 3 5 6 9 10 12 1414 F H J K M N RAA AC AD 4Bm 4Bm 4Bm 11' - 4 7/8"2' - 0" (CLEAR)7 5/8"15' - 4 1/2"(CLEAR)8' - 6"7 5/8"(CLEAR)8' - 6"3' - 3 1/2"7 5/8" (CLEAR)7' - 6 7/8"9' - 8 1/8"5' - 4 3/4"5' - 4 3/4" 9' - 3 1/8"8' - 2 1/4"C C D.9 L 7 8 13.113.1 A1 A-311 A2 A-311 A4 A-311 B2 A-312 B3 A-312 B4 A-312 C1 A-313 C2 A-313 C3 A-313 C4 A-313 D1 A-314 D3 A-314 A3 A-311 E1 A-315 B1 A-3126Sm 6Sm 6Bm 12.9 E.1 E2 A-315 A-411 A2 A-412 A2 6Bm6Bm 4Am 14' - 0" (RAMP)9' - 0 7/8"5' - 0"18' - 0"(20'-0" MIN)22' - 8 1/2"18' - 0"18' - 0" (20'-0" MIN) 21' - 9" 18' - 0"18' - 0"(20'-0" MIN)22' - 8 1/2"18' - 0"(TYP WIDTH) 9' - 0"(TYP STALL DEPTH)18' - 0"ONE-WAY ONE-WAY ONE-WAY ONE-WAY TWO-WAY (RAMP ONLY) ONE-WAY ONE-WAY (20'-0" MIN)21' - 11 5/8"18' - 0"5' - 0"DWGS)(SEE PC5' - 9"5' - 9"4Am 4Am 4Am 4Am 2' - 0"106 106 106106 13.513.5 A-414 A3 A-414 A2 19424 SF TWO-STORY OPEN PUBLIC PARKING GARAGE P150G A-414 A1 SF9 SF19 E4 A-315 D.5 D.5 AB 8' - 0" 14' - 6 1/2"33' - 5 1/2" 56' - 0"5' - 9" (SEE PRECAST DRAWINGS) 156' - 9" 34' - 0"104' - 8"27' - 4" 2' - 0" 213' - 5 3/8"2' - 0"27' - 4"104' - 8"34' - 0"213' - 5 3/8"CL CL 12' - 4"12' - 4"8' - 0"14' - 6 1/2"33' - 5 1/2"56' - 0"5' - 9"(SEE PRECAST DRAWINGS)146' - 1"121121 14' - 0"17' - 2" 17' - 2" 1 4 ' - 0 " A-323 A1 A-323 A2161.5°1 6 1 .5 °116.5°116.5° A-323 A3 A-322 C1 A-322 C2 116 116 116 116 116 116 119119119119 135.0°135.0°(RAMP WIDTH)25' - 0"18' - 0"5' - 9" 111' - 4 1/2"111' - 4 1/2"5' - 6" 16' - 8 7/8"16' - 8 7/8"5' - 6"23' - 10 3/8"18' - 2 1/2"150M1 150M2 150M3150L A-413 A3 Sim 130130 *REFER TO CIVIL DRAWINGS FOR OFFICIAL PARKING LAYOUT AND DETAILS COMPACT 7' - 10"COMPACT7' - 10"INDICATES CEILING/PLENUM SPACE TO FLOOR LEVEL BELOW INDICATES NON-DRIVING CIRCULATION AREA OF PARKING LOT/RAMP/STAIR CONNECTOR AREAS INDICATES APPROXIMATE TYPICAL PARKING STALL, SEE CIVIL ARCHITECTURE ENGINEERING GEOSPATIAL│ │ 333 NORTH ALABAMA STREET SUITE 200 INDIANAPOLIS, IN 46204 317.299.7500 SHEET KEYNOTES: LEGEND: GENERAL NOTES:ISSUANCE SCHEDULE SHEET NAME: PROJECT NO: DATE ISSUED: NOT FOR CONSTRUCTION NUMBER DATE DESCRIPTION SHEET NO: DRAWN BY: CHECKED BY: PRELIMINARY SUBMITTAL BIM 360://NOVO Development_1215 Rangeline-Indy/A_1215 Rangline_R20.rvt6/24/2022 11:14:26 AMUPPER PARKING FLOOR PLAN A-101.5 RH RH 081948 06/24/22PROSCENIUM PHASE II (1215)NOVO DEVELOPMENT GROUP1215 RANGELINE RDCARMEL, IN 46032NEW MIXED USE MULTI-FAMILY PROJECT24'16'8'4'0 1/8"=1'-0" GRAPHIC SCALE PLAN NORTH 1/8" = 1'-0" SECOND FLOOR PLAN (P)A1 106 POLE MOUNTED LIGHT FIXTURE, SEE ELECT DWGS 116 INDICATES AREA OF FIRE-RATED VERTICAL CHASE FROM GROUND FLOOR TO ROOF ABOVE 119 PRECAST CONCRETE OPEN PARKING GARAGE, SEE PC DWGS 121 INDICATES AREA OF TYPICAL PARKING STALL, SEE CIVIL DWGS 130 PROVIDE GALVANIZED LOOP/WAVE STYLE BIKE RACK WITH CONCRETE MOUNTING HARDWARE OR APPROVED EQUAL (10 BIKE CAPACITY MIN AT THIS AREA)