Loading...
HomeMy WebLinkAboutA-101-5 - UPPER PARKING FLOOR PLANA. ALL DIMENSIONS TO BE VERIFIED IN FIELD PRIOR TO CONSTRUCTION. NOTIFY ARCHITECT OF ALL DISCREPANCIES PRIOR TO STARTING WORK B. ALL DIMENSIONS ARE FACE OF MASONRY, POURED/PRECAST CONCRETE, OR FACE OF STUD (WOOD OR METAL, UNO) C. ALL DIMENSIONED STOREFRONT SYSTEMS ARE NOMINAL ROUGH OPENINGS, UNO D. ALL RESIDENTIAL UNITS TO BE ACCESSIBILITY TYPE B, UNO ( ONLY UNITS 202, 205, & 206 TO BE TYPE A) E. ALL INTERIOR PARTITIONS TO BE TYPE 4Am (ON GROUND AND MEZZANINE LEVELS) 4Aw (ON UPPER LEVELS)UNLESS NOTED OTHERWISE. REFER TO SHEET A-002 FOR PARTITION DETAILS/SCHEDULE F. ALL INTERIOR DOOR FRAMES SHALL BE LOCATED A DISTANCE OF FOUR INCHES FROM THROAT RETURN TO THE CLOSEST ADJACENT PERPENDICULAR PARTITION, UNO G. PROVIDE SOLID BLOCKING/BACKING IN-WALL CAVITIES AT ALL WALL MOUNTED CASEWORK, FIXTURES, EQUIPMENT, AND SHELVING. REFER TO TYPICAL PARITION AND INTERIOR ELEVATIONS FOR ADDITIONAL INFORMATION H. REFER TO MEP AND FIRE PROTECTION DRAWINGS FOR MOUNTING HEIGHTS OF SWITCHES, OUTLETS, ALARMS AND ALL SURFACE MOUNTED COMPONENTS. I. ALL MASONRY DIMENSIONS ARE NOMINAL, UNO J. PROVIDE 24" X 24" MIN FIRE RATED ACCESS PANELS TO ALL CHASES AT EVERY FLOOR LEVEL FOR ACCESSIBILITY GREASE PIPE(S) AND MECHANICAL DUCTS. K. ALL DOORS FROM CORRIDOR(S) TO STOR (STORAGE) & MECH ELECT (MECHANICAL ELECTRICAL) ROOMS ARE TO BE CENTERED ON THE INTERIOR OF THE SPACE, UNO L. REFER TO SHEET A-601/A-602 FOR DOOR/WINDOW SCHEDULE, TYPES, & DETAILS M. REFER TO INTERIOR DESIGN DRAWINGS FOR ALL INTERIOR FINISH PLANS, SPECIFICATIONS, & DETAILS N. REFER TO STRUCTURAL DRAWINGS FOR GROUND FLOOR CONCRETE SLAB LEAVE OUT LOCATIONS, TYP O. DRAFT STOPS REQUIRED IN THE FLOOR ASSEMBLIES IN LINE WITH EACH DWELLING UNIT SEPERATION. REQUIRED IN ATTIC TO SEPERATE SPACE ABOVE EVERY TWO DWELLING UNITS OR 3000SF, WHICHEVER IS LESS P. ALL RESIDENTIAL UNITS ON FLOORS 3&4 TO RECEIVE 1-1/8" GYPCRETE TOPPING ON 3/8" PREMIUM ACOUSTIMAT OR SIMILAR ON TOP OF WOOD DECK, TYP Q. CORRIDORS & PUBLIC INTERIOR SPACES ON FLOORS 3&4 TO RECEIVE 1-1/2" GYPCRETE TOPPING ONLY ON TOP OF WOOD DECK, TYP R. ALL RESIDENTIAL UNITS ON FLOOR 5 ONLY TO RECEIVE 2-1/8" GYPCRETE TOPPING ON 3/8" PREMIUM ACOUSTIMAT OR SIMILAR ON TOP OF WOOD DECK, TYP S. CORRIDORS & PUBLIC INTERIOR SPACES ON FLOOR 5 ONLY TO RECEIVE 2-1/2" GYPCRETE TOPPING ONLY ONY TOP OF WOOD DECK, TYP A-202 D2 A-202 A2 A-201 D1 A A 1717 A1 A-301 A1 A-301 RAMP (DOWN) NORTH STAIR N1 EAST STAIR E1 ELEV 1 ELEV 2 390 SF LOBBY 150L 60 SF UNISEX RR 150M3 55 SF MECH 150M2 A2 A-301 A2 A-301D D E 1313 B1 A-302 B1 A-302 B2 A-302 B2 A-302 16 B 1 2 4 11 G P S T 1515 A-203 A1 3 5 6 9 10 12 1414 F H J K M N RAA AC AD 4Am 4Am 4Am 11' - 4 7/8"2' - 0" (CLEAR)7 5/8"4' - 7 7/8"8' - 0"2' - 8 5/8"(CLEAR)8' - 6"7 5/8"(CLEAR)8' - 6"3' - 3 1/2"7 5/8" (CLEAR)7' - 6 7/8"9' - 8 1/8"5' - 4 3/4"5' - 4 3/4" 9' - 3 1/8"8' - 2 1/4"C C D.9 L 7 8 13.113.1 6Sm 6Sm 6Bm 12.9 E.1 A-411 A2 A-412 A2 6Bm6Bm 4Sm 14' - 0" (RAMP)9' - 0 7/8"5' - 0"18' - 0"(20'-0" MIN)22' - 8 1/2"18' - 0"18' - 0" (20'-0" MIN) 21' - 9" 18' - 0"18' - 0"(20'-0" MIN)22' - 8 1/2"18' - 0"(TYP WIDTH) 9' - 0"(TYP STALL DEPTH)18' - 0"ONE-WAY ONE-WAY ONE-WAY ONE-WAY TWO-WAY (RAMP ONLY) ONE-WAY ONE-WAY (20'-0" MIN)21' - 11 5/8"18' - 0"5' - 0"DWGS)(SEE PC5' - 9"5' - 9"4Sm 4Sm 4Sm 106 106 106106 13.513.5 A-414 A3 A-414 A2 19424 SF TWO-STORY OPEN PUBLIC PARKING GARAGE P150G A-414 A1 SF9 SF19 D.5 D.5 AB 8' - 0" 14' - 6 1/2"33' - 5 1/2" 56' - 0"5' - 9" (SEE PRECAST DRAWINGS) 156' - 9" 34' - 0"104' - 8"27' - 4" 2' - 0" 213' - 5 3/8"2' - 0"27' - 4"104' - 8"34' - 0"213' - 5 3/8"CL CL 12' - 4"12' - 4"8' - 0"14' - 6 1/2"33' - 5 1/2"56' - 0"5' - 9"(SEE PRECAST DRAWINGS)146' - 1"121121 14' - 0"17' - 2" 17' - 2" 1 4 ' - 0 " A-323 A1 A-323 A3161.5°1 6 1 .5 °116.5°116.5° A-323 A5 A-322 D1 A-322 D4 116 116 116 116 116 116 119119119119 135.0°135.0°(RAMP WIDTH)25' - 0"18' - 0"5' - 9" 111' - 4 1/2"111' - 4 1/2"5' - 6" 16' - 8 7/8"16' - 8 7/8"5' - 6"23' - 10 3/8"18' - 2 1/2"150M2 150M3150L A-413 A3 Sim *REFER TO CIVIL DRAWINGS FOR OFFICIAL PARKING LAYOUT AND DETAILS COMPACT 7' - 10" G2 G1 2.5 2.9 A1 A4 A3 A6 A2 A5 G3 GB GC GD GE GA7 G4 GB.2 S.5S.1 GC.8 A0 A8 A4 A-311 A2 A-311 A3 A-311 A1 A-311 A4 A-312 A3 A-312 A2 A-312 A1 A-312 A3 A-313 A2 A-313 A1 A-313 A3 A-314 A2 A-314 A1 A-314 A4 A-315 A3 A-315 A2 A-315 A1 A-315 A4 A-316 A3 A-316 A2 A-316 A1 A-316 A4 A-317 A3 A-317A2 A-317 A4 A-318 A1 A-317 A3 A-318 A2 A-318 A1 A-318 34 SF JANITOR 150M1150M1 2' - 0" 4Sm PARKINGNO1302' - 0"2' - 6" 20' - 3" 2' - 6"2' - 6"2' - 6"2' - 6"2' - 6"2' - 6"2' - 6 5/8"11' - 7"6' - 0"130 2' - 0"2' - 6"2' - 6"2' - 6"2' - 6"2' - 6" 152152 EQ4' - 6"EQINDICATES CEILING/PLENUM SPACE TO FLOOR LEVEL BELOW INDICATES NON-DRIVING CIRCULATION AREA OF PARKING LOT/RAMP/STAIR CONNECTOR AREAS INDICATES APPROXIMATE TYPICAL PARKING STALL, SEE CIVIL 24'16'8'4'0 1/8"=1'-0" GRAPHIC SCALE PLAN NORTH 1/8" = 1'-0" UPPER PARKING FLOOR PLANA1 106 POLE MOUNTED LIGHT FIXTURE, SEE ELECT DWGS 116 INDICATES AREA OF FIRE-RATED VERTICAL CHASE FROM GROUND FLOOR TO ROOF ABOVE; PROVIDE 12" TPO WEATHERED IN CURB 119 PRECAST CONCRETE OPEN PARKING GARAGE, SEE PC DWGS 121 INDICATES AREA OF TYPICAL PARKING STALL, SEE CIVIL DWGS 130 PROVIDE INVERTED-U STYLE BIKE RACK WITH CONCRETE MOUNTING HARDWARE OR APPROVED EQUAL (10 BIKE CAPACITY MIN AT THIS AREA) 152 PARKING BOLLARD, PAINTED ARCHITECTURE ENGINEERING GEOSPATIAL│ │ 333 NORTH ALABAMA STREET SUITE 200 INDIANAPOLIS, IN 46204 317.299.7500 SHEET KEYNOTES: LEGEND: GENERAL NOTES:ISSUANCE SCHEDULE SHEET NAME: PROJECT NO: DATE ISSUED:NUMBER DATE DESCRIPTION SHEET NO: DRAWN BY: CHECKED BY:BIM 360://NOVO Development_1215 Rangeline-Indy/A_1215 Rangline_R20.rvt8/12/2022 4:12:58 AMUPPER PARKING FLOOR PLAN A-101.5 RH RH 081948 07/29/22PROSCENIUM PHASE II (1215)NOVO DEVELOPMENT GROUP1215 RANGELINE RDCARMEL, IN 46032NEW MIXED USE MULTI-FAMILY PROJECTISSUED FOR PERMIT