HomeMy WebLinkAbout[1] C501 DETAILS6" CONCRETE SLAB DETAIL TYPICAL PAVEMENT SECTION CONCRETE STOOP DETAIL (ADJACENT TO SIDEWALK) CONCRETE STOOP DETAIL FIRE HYDRANT ASSEMBLY TYPICAL CONSTRUCTION FOR LATERAL CONNECTIONS TYPE 1, 2 & 3 ™ Phone (888) 344-9044 Fax (423) 826-2112 STORMWATER TREATMENT SOLUTIONS www.aquashieldinc.com Aqua-Swirl Concentrator Model AS-4 PCS Standard Detail AS-4 PCS STD 02/05/15 Scale: Drawn By: Document: Date: JCW 1:20 U.S. Patent No. 6524473 and other Patent Pending * Please see accompanied Aqua-Swirl specification notes. * See Site Plan for actual system orientation. ** Orientation may vary from 90°, 180°, or custom angles to meet site conditions. 12" [305 mm] PCS Max A Inlet66" [1676 mm] 12" [305 mm] PCS Max 66" [1676 mm] Outlet A Ø54" [Ø1372 mm] Pipe coupling by Contractor. 12" long Stub-out by Manufacturer. Pipe coupling by Contractor. 12" long Stub-out by Manufacturer. Vent Arched Baffle Octagonal Base Plate STORMWATER TREATMENT SOLUTIONS Phone (888) 344-9044 www.aquashieldinc.com ™ Vent Arched Baffle Slide riser over top ring and bolt in 4 placesRiser 68" [1727 mm] 104" [2642 mm] Swirl Inlet Swirl Outlet Bedding Undisturbed Soil Backfill 6" [152 mm] 18" [457 mm] Section A-A Plan View Grade (Rim) 30" [762 mm] Rim elevations to match finished grade. Manhole Frame and Cover by Manufacturer. (See Details)5" [127 mm] MH Frame Varies 90°** Varies Backfill shall extend at least 18 inch [457 mm] outward from Swirl Concentrator and for the full height of the Swirl Concentrator (including riser) extending laterally to undisturbed soils. (See MH Detail Below) 4 1/2" [114 mm] 1/2" [13 mm] 1" [25 mm] Manhole Frame & Cover Detail NTS For Non-Traffic Areas Only Soil 1" [25 mm] Unless other traffic barriers are present, bollards shall be placed around access riser(s) in non-traffic areas to prevent inadvertent loading by maintenance vehicles. Soil Place small amount of concrete [3,000 psi [20 MPa] (min)] to support and level manhole frame. DO NOT allow manhole frame to rest upon riser. Riser Frame Cover 48" [1219 mm] Min. 12" [305 mm] Wrap Compressible Expansion Joint Material to a minimum 1-inch [25 mm] thickness around top of riser to allow transfer of inadvertent loading from manhole cover to concrete slab. Backfill (90% Proctor Density) Concrete Concrete8" [203 mm] Gravel Backfill Gravel Backfill 4 1/2"Cover Frame 1" [25 mm] Thick Expansion Joint Material30" [762 mm] Riser #4 [13 mm] Rebar @ 6" [152 mm] Each Way 14"1/2" 3,000 psi [20 MPa] (min) Concrete Manhole Frame & Cover Detail For Traffic Loading Areas NTS If traffic loading (HS-25) is required or anticipated, a 4-foot [1.22 m] diameter, 14-inch [356 mm] thick reinforced concrete pad must be placed over the Stormwater Treatment System Riser to support and level the manhole frame, as shown. The top of riser pipe must be wrapped with compressible expansion joint material to a minimum 1-inch [25 mm] thickness to allow transfer of wheel loads from manhole cover to concrete slab. Manhole cover shall bear on concrete slab and not on riser pipe. The concrete slab shall have a minimum strength of 3,000 psi [20 MPa] and be reinforced with #4 [13 mm] reinforcing steel as shown. Minimum cover over reinforcing steel shall be 1-inch [25 mm]. Top of manhole cover and concrete slab shall be level with finish grade. Backfill (90% Proctor Density) 48" Aqua-Swirl Polymer Coated Steel (PCS) Stormwater Treatment System 2733 Kanasita Drive, Suite 111, Chattanooga, TN 37343 Note: AS an alternative, 42-inch OD, HS-25 rated precast concrete rings may be substituted. 14-inch thickness must be maintained. DIVERSION STRUCTURE DETAIL STR. NO. 1.6 OUTLET CONTROL STRUCTURE PRECAST CONCRETE WHEEL STOP C501 DETAILSCKD.DR.DES.DATEPROJECT No:REVISIONDATENo.PROSCENIUM II1215 SOUTH RANGELINE ROADCARMEL, INDIANA333 North Alabama StreetSuite 200Indianapolis, IN 46204317.299.7500FAX: 317.291.5805Preliminary 01/09/2022 1:57:21 PM