HomeMy WebLinkAbout06060072 Site Plan
,.,
Scmeider
lluI ScImeIder CorporaUon
_0lII.......
_ lcrlllanboD
1...U.".pnll.. lIld1ana ~a-103'1
317-&8-'1100
317-&8-7200 r.II
This Plot Plan Prepored For: Arbor Homes
Lot # 33 ,containing 12,649 S.F.:!:, in
The Trails at Hayden Run Sec. 1
INSTR. # 200500069468
Clay Twp, Hamilton County
See 20, T29N, R3E
14167 Langham Drive (50'R/W)
Westfield, IN 46074
Prepared Date: 05-22-06: By. MBK
Community Restrlctlon~
SIde .Yard -3' min.
Roar Yard - N/A
Aggregcte - 6 (B.H.)
Arbor Homes
Finished Floor Elevation information
Pad Grade = 920.6 per plan
Pad Grade + 1.0' - Gorage FFE (921.6)
Gorage FFE + 0.5' = Reeldentiol FFE (922.1)
Resldentiol FFE - 10.0' = Bosoment FFE (912.1 )
Note : The gorage finished floor elevation
Is 1.6' above the curb at the drive, per
plan.
GROIJNO COVER CALCULA l1ONS;
Orlve = 9:53 Sf:l:
Public WoIk =317 Sf:l:
Prliate WoIk = 66 Sf:l:
Seeding = 6,842SF:I:
Sod =.3149 SF:I: ,
even .,iIl the reor of house.
1'1
JO.a'
B-B
r-
)> 5.0'
:z: PER PlAN I
G)
:J:
I )> ....
I 3:: !
I 0
I :::0
I rii
I
,
,
I
Plot Pion leqend
~ Proposed Grades
000.0 Exleting Grades
- 000.0- Contour Grade
* Appro,. lateroJ location
- . - Sanitary Sewer lines
- 11'- Storm Sewer lines
-'W-WaterServlcellnes
- - - - - - - Sub-Surface Drain Unes
. WanhoJe (Sanltery or Storm)
. B.ehlve Inlet (Storm)
l1li Curb Inl.t (Storm)
o End Section (storm)
... Flr. H)llrant
- 000 _ 000 - Flow Une of swate
140.00'
14.5' !(l
~ 76.9'
... 35.67
i:i ~ I
g 1
">
~il ~I o. to
P 9
~L <:: 0
1< ;i! ~I 5; q
""
~~ I~ t ~ i!l ~ I
~
I~ ~ ~ 1.75' 0 1
is
~ 20.33' & 1
!(l
14.5' 115.00' I
~
......,.,.
WIdocopo in>hlleol"",
G1S.1l3
Gtolocr
Not~ Sanitary Sewer
Top of Costing Information
Upstream Wonhol.. TCa 920.05
Downstreom Manhole, TC- 920.46
Per Record Drawing
Note:
The contractor Is to maintain Q
mlnmum dl.tonce af ten feet (10')
between the sonlby sewer and water
IIn.laterols
NOTE:
SUMP PUWP(S) TO BE PLACED
BY BUILDER AS NEEDED.
SlR 1808
Tea920.OS
PER RECORO DRA'MNG
~.
flOOD HAZARD STATEMENT
CERllFlCA 110N
,\\\\\\\\\11I1I1I/I//I/III~
#~~ La'
~ ~~ ",,"".... ;f~~
~~'4,G\S TE:"'~.........A~
~<::) ..'~ No <> "";.o~
I ( S0303-\-l.
_.s-...,;~ j s
~ ~. STATE OF i ifg
~ .,;1:.... ..... ~
~~ ......../tvo,.."'':... ~~
~ ..;~..........."...{''> ~
" SUR~ \'1/.#
W//"I//fIIIII\1\\\\\\\\\\~
~l.rv
SlRI600
Tea920."
PER RE~ DRA'MNG
RE\lSON 1
ADD DEll<.
CHANG!': BRJa<
1Il06.0055136
05-23-06 SKN
Not~
Per Corm~ zonIng ordinance 26.1.1 : Th. resldentlol
district limits h~ght to twenty-five feet (25'). however
a dw~llng may be Incrsaeed In h.lght to thrty-flve
feet (35') prolid.d tho .Ide and rear yard. or. Incrsaeed
on addltlonol on. foot (1') far sach on. foot (1') the
structure exceed. the fl"t twenty-flve feet (25') in
h~ght
Flood Hazcrd statement: The accuracy of any flood hazard doto shown on thIs report Is lRJbject to map
ICOII uncertailty and to any other uncertainty In location or e1eyoUon on the referenced flood Insurance
rate map. AU. of the within _ land DOES NOT UE within that spoclol flood hazard zan. A as said
11Ild ~ats by ocaI. on flood 1nsuronce rot. map I 18057C0205F far City af earm_, Indiana (map. dated
FobrIJery 19, 2003).
Note:
This drawing Is based on construction plans or record drawings,
and Is not based upon a fl~d survey. The Schn.lder Corporation
does not warrant the accuracy or sufficiency of this information.
Contractors should verify existing condition. prior to ony
constructIon. MY dIscrepancy found on this drawing should
be reported to The Schneider Corporation Immediately. foRing
to do so results In the contractors assumption of all lIabDlty.
LOT # 33
VB # 06.0054972
DetaR of twlcel Storm
Water now pattern for
Indllidu.lats.
[m
o
-- --
Note;
BuDder to ensure posttive drainage
away from structure(s).
o
~
=li:3.=
o
Assumed North
~O
SCALE I" - 3D'
z
,.
\,
o;!. cRt.
....LE SECTION