2'-10" 12'-0" 6'-8 1/2" 14'-6"21'-0" 7'-11 1/2"11'-1 1/4"6'-11" 17'-2 3/4"13'-8"13'-3 1/2"11'-0"
12'-5"
FAMILY ROOM
8'-0" CEILING
WOOD FLOOR
SCREEN PORCH
VAULTED CEILING
CONCRETE SLAB
DEMO FALSE BEAMS
GAS METER
ELECTRICAL PANEL
AND METER
KITCHEN
8'-0" CEILING
WOOD FLOOR
LAUNDRY
8'-0" CEILING
WOOD FLOOR
GARAGE
8'-7" CEILING
CONCRETE SLAB
DINING
8'-0" CEILING
WOOD FLOOR
ENTRY
8'-0" CEILING
WOOD FLOOR
LIVING ROOM
8'-0" CEILING
CARPET
POWDER
8'-0" CEILING
WOOD FLOOR
WH
UP
11'-10"
MECH
EXPOSED CLG
CONCRETE
MEDIA
7'-9" CEILING
CARPET
STORAGE
EXPOSED CLG
CONCRETE
CRAWL SPACE
EXERCISE
EXPOSED CLG
LVP FLOORING
MAIN DRAIN
WALL MOUNTED RAIL
NO RAILING
LINE OF
BULKHEAD
STEEL BEAM
DN
SD
6'-2" 14'-8" 3'-3 1/2" 11'-1 1/4"15'-2"2'-0"11'-4 1/2"11'-3"8'-5 1/4" 15'-11"13'-9"8'-6 1/2"6'-3"36'-4 1/4"
PRIMARY BEDROOM
8'-0" CEILING
CARPET
BEDROOM 2
8'-0" CEILING
CARPET
BEDROOM 3
8'-0" CEILING
CARPET
BEDROOM 4
8'-0" CEILING
CARPET
HALL
8'-0" CEILING
CARPET
C
2022 WGG
THIS PLAN IS PROPERTY
OF
WILLIAM GORDON GROUP.
ANY UNAUTHORIZED USE
OR REPRODUCTION OF
THIS PLAN, IN WHOLE OR
IN PART IS PROHIBITED.
WGG WILL USE ALL LEGAL
MEANS AVAILABLE TO
PURSUE THE
UNAUTHORIZED USE OF
THIS PLAN OR ANY DESIGN
ELEMENTS CONTAINED
THEREIN.Kory / Minich Residence - First Floor Interior RemodelCool Creek North; Section 2; Lot 58184 Hawthorne Drive, Carmel, Indiana 46033Date
09.12.22
Existing Basement Floor Plan
SCALE: 1/8" = 1'-0"
Description
Existing
Floor Plans
Sheet Number
A-01
Existing First Floor Plan
SCALE: 1/8" = 1'-0"
Existing Second Floor Plan
SCALE: 1/8" = 1'-0"
Typical Door and Window Framing
SCALE: 1/4" = 1'-0"
(2) 2x12 HDR
(2) 2x12 HDR
SEE FLOOR PLANS AND WALL SECTION
FOR TOP PLATE HEIGHTS
SEE FLOOR PLANS FOR
HEADER HEIGHTS
KING AND JACK STUDS
DOOR
WDW
SEE FLOOR PLAN AND SECTION NOTES
FOR SPECIFIC UNIQUE BEAM SIZES
Area Location Map
NO SCALE
SQUARE FOOTAGE TABLE
SFGARAGE 528
SF
SF
SECOND FLOOR
FIRST FLOOR 1,260
1,080
SFBASEMENT (FIN & UNFINISHED) 1,044
REMODELED AREA - BASEMENT
REMODELED AREA - FIRST FLOOR
SF528
SF
SF1,260
1,080
SF1,044
SF0
SF1,260
EXISTING PROPOSED
ZONING - R1
REMODELED AREA - SECOND FLOOR SF0
GENERAL NOTES:
WRITTEN DIMENSIONS AND SPECIFIC NOTES SHALL
TAKE PRECEDENCE OVER SCALED DIMENSIONS AND
GENERAL NOTES. THE ENGINEER/DESIGNER SHALL BE
CONSULTED FOR CLARIFICATION IF SITE CONDITIONS
ARE ENCOUNTERED THAT ARE DIFFERENT THAN
SHOWN, IF DISCREPANCIES ARE FOUND IN THE PLANS
OR NOTES, OR IF A QUESTION ARISES OVER THE INTENT
OF THE PLANS OR NOTES. CONTRACTOR SHALL VERIFY
AND IS RESPONSIBLE FOR ALL DIMENSIONS (INCLUDING
ROUGH OPENINGS).
ALL CONTRACTORS ARE TO CLEAN UP THE JOBSITE PER
THEIR WORK.
THE BUILDER SHALL VERIFY THAT SITE CONDITIONS ARE
CONSISTENT WITH THESE PLANS BEFORE STARTING
WORK.
WORK NOT SPECIFICALLY DETAILED SHALL BE
CONSTRUCTED TO THE SAME QUALITY AS SIMILAR
WORK THAT IS DETAILED.
ALL WORK SHALL BE DONE IN ACCORDANCE WITH
INTERNATIONAL BUILDING CODES AND LOCAL CODES.
09/27/22