Loading...
HomeMy WebLinkAboutFT Plans(Part 1) 1383180 for Contract Services1 ROAD PLANS GUILFORD ROAD PROJECT LOCATION SHOWN BY DESIGNATION SHEETS PROJECT SURVEY BOOK CONTRACT of A.A.D.T. (2018) A.A.D.T. (2038) D.H.V (2038) DIRECTIONAL DISTRIBUTION TRUCKS DESIGN SPEED PROJECT DESIGN CRITERIA FUNCTIONAL CLASSIFICATION RURAL/URBAN TERRAIN ACCESS CONTROL 50% POS. PROJECT DESIGNATION CONTRACT INDIANA DEPARTMENT OF TRANSPORTATION O A A ATIN T F T R N SPORTATIONNA DEPRME N D I 1.5% A.A.D.T. 1.5% D.H.V. APPROVED FOR LETTING: DATE PHONE NUMBER PLANS PREPARED BY: DATE CERTIFIED BY: LATITUDE: 39° 58' 77" N LONGITUDE: 86° 08' 27" W INDIANA DEPARTMENT OF TRANSPORTATION TRAFFIC DATA DESIGN DATA INDIANA DEPARTMENT OF TRANSPORTATION STANDARD SPECIFICATIONS DATED 2018 TO BE USED WITH THESE PLANS DIRECTORY PATH: R:\Active\Carmel\Guilford Road Des. No. 1383180\CAD\PlansFILENAME: TITLESHT.dwgDATE/USER: 7/23/2018 9:44 AM / AwolfGUILFORD RD. CROSSROAD ENGINEERS, P.C. 1383180 1383180 R-36906 6,885 V.P.D. 8,265 V.P.D. 670 V.P.H. 1383180 1383180R-36906 (317) 780-1555 HAMILTON COUNTY PROJECT NO.1383180 PE MAIN ST. RECONSTRUCTION (NON-FREEWAY) MINOR ARTERIAL URBAN (BUILT-UP) LEVEL NONE 35 M.P.H. Road Reconstruction on Guilford Road from City Center Drive to West Main Street Located 0.9 Miles North of 116th Street Section 25 and 36, T-18-N, R-3-E, Clay Township, Hamilton County, Indiana. 49% POS. 1% A.A.D.T. 1% D.H.V. 10,590 V.P.D. 12,710 V.P.D. 1,200 V.P.H. RECONSTRUCTION (NON-FREEWAY) MINOR ARTERIAL URBAN (BUILT-UP) LEVEL NONE 30 M.P.H. HAMILTON CO. C L A Y 2627 25 30 31363534 6123 19242322 29 32 5 20 U. S. 31Guilford Rd.Keystone Pkwy.City Main St. E 116th St. Carmel Dr. BEGIN PROJECT STA. 14+95.30 "B" END PROJECT STA. 50+39.01 "B" U. S. 3 1 Main St.Keystone Pkwy.GROSS LENGTH: MAX. GRADE: MI. MI. % NET LENGTH: 0.7 4.00 0.7 SCALE: 1" = 2000' BEGIN CONSTRUCTION STA. 8+20.75 "S-1-B" END CONSTRUCTION STA. 12+19.06 "S-1-B" 1383180 R/W 1383180 CONSTR CenterDr. 4/2/18 PLANS PREPARED BY TRANSPORTATION & DEVELOPMENT CONSULTANTS 3417 SHERMAN DRIVE BEECH GROVE, IN 46107 (317) 780-1555 CROSSROADENGINEERS.COM ANDR E W J OHN W O L F76 TYPICAL CROSS SECTIONS INDEX SHEET AND GENERAL NOTES2 TITLE SHEET1 DRAWINGS INDEXSHEET NO. INDEX REVISEDDATESHEET NO GENERAL NOTESUTILITIES REVISIONS ROAD PLAN AND PROFILES MAINTENANCE OF TRAFFIC CROSS SECTIONS (57 SHEETS) MISCELLANEOUS TABLES PAVEMENT MARKING AND SIGNING DETAILS ** 3 XS-1 - XS-57 A.J.W. RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALEINDIANA DEPARTMENT OF TRANSPORTATION M.B. A.P. M.B. 4/2/2018 VERTICAL SCALE 1383180 1383180 R-36906 76ERR 1 S EF SPRO NO. ASTATE OF D NIO IN LA AI N 01306 NGINE 27 EERIGEETS DANDREW JOHN W O L FDIRECTORY PATH: R:\Active\Carmel\Guilford Road Des. No. 1383180\CAD\PlansFILENAME: RD-INF.dwgDATE/USER: 7/23/2018 9:44 AM / AwolfINDEX SHEET 13-19 CONSTRUCTION DETAILS 4-6 43-44 20-34 7-12 PLAT NO. 1 LIGHTING, CONDUIT, AND COMMUNICATION DETAILS EROSION CONTROL SHEETS 2 STRUCTURE DATA TABLE GEOMETRIC DETAILS 35-40 ROUNDABOUT EXISTING & PROPOSED CONTOURS 41 CULVERT DETAILS 42 SIGN SUMMARY TABLES UNDERDRAIN TABLES PIPE MATERIAL SHEET 45 48-53 54-56 57-59 60-62 63 64 65 The exact location of all utilities shall be field verified by the contractor prior to starting any work. Sheet signs and square posts shall not be ordered until the exact number of signs and length of each post have been determined upon field investigation. A utility location service will be contacted by the construction contractor in accordance with Indiana Code (IC) 8-1-26 prior to construction to ensure that public water systems and other public utilities are not adversely affected. If groundwater is encountered at 811 West Main Street or 808 West Main Street, lab anlysis will occur prior to management of the groundwater. Do not work in the waterway from April 1 through June 30 without the prior written approval of the Division of Fish and Wildlife. Do not excavate in the low flow areas except for the placement of piers, foundations, and riprap, or removal of the old structure. Do not construct any temporary runarounds or causeways. 404 Regional General Permit (RGP) general conditions can be found on the permits tab of the contract documents. All conditions shall be followed unless specifically removed in a special condition or the permit amended by the contractor. 401 Water Quality Certification conditions can be found on the permits tab of the contract documents. All conditions shall be followed unless specifically removed in a special condition or the permit amended by the contractor. The Rule 5 SWPPP, NOI and NOS can be found on the permits tab of the contract documents. The NOI and NOS shall be posted at the job site. The Rule 5 SWPPP, Storm Water Quality Control Plan (SWQCP), and all amendments shall be housed in project construction office and available upon request. The SWQCP shall be approved by INDOT at least 14 days before earth disturbance. All storm water quality measures and erosion and sediment control necessary to comply with 327 IAC 15-5 must be implemented in accordance with the SWQCP and sufficient to minimize off site sedimentation and pollution releases. Construction activities shall follow all current standard specifications including RSP 205-R-636 and the SWQCP unless specifically amended during project development or agreed to by the project engineer. All permits obtained for this project will be posted and maintained at the project site until the project is completed. * * * * * AT&T Contact: Jeff Rice Ph: (317) 610-5438 jr2647@att.com CARMEL SANITARY Contact: Joe Faucett Ph: (317) 571-2634 jfaucett@carmel.in.gov CARMEL WATER Contact: Steve Cook Ph: (317) 716-3913 scook@carmel.in.gov CENTURYLINK Contact: Dewayne Hamilton Ph: (317) 966-9956 dewayne.hamilton@centurylink.com COMCAST Contact: Scott Evans Ph: (317) 752-6569 sevans@telecomplacement.com DUKE ENERGY Contact: Dan Benson Ph: (317) 776-5340 dan.benson@duke-energy.com SPECTRUM Contact: Joe Burton Ph: (317) 632-9077 joe.burton@charter.com VECTREN Contact: Brian Harger Ph: (317) 776-5534 bharger@vectren.com ZAYO BANDWIDTH Contact: Waylon Higgins Ph: (765) 341-1199 waylon.higgins@zayo.com SPOT ELEVATION DETAILS ROUNDABOUT CURB PROFILES AND SPOT ELEVATIONS 66-67 CITY OF CARMEL STANDARD DETAILS68-69 WATER MAIN AND SANITARY SEWER REPLACEMENT DETAILS70-76 RETAINING WALL DETAILS46-47 * * * * Combined Concrete Curb & Gutter, Barrier, Modified Concrete Curb (Barrier) 165#/Syd. QC/QA-HMA, 3, 64, Surface 9.5 mm on 1.5" Surface Milling Modified Roll Curb Sodding C2 HMA Pavement 165#/Syd. QC/QA-HMA, 3, 64, Surface 9.5 mm, on 275#/Syd. QC/QA-HMA, 2, 64, Intermediate 19.0 mm, on 330#/Syd. QC/QA-HMA, 2, 64, Base 19.0 mm, on PCCP, 7" (Slate Green color) with D-1 Contraction Joints Spaced at 14' Max, on 10" Compacted Aggregate No. 53, on Subgrade Treatment Type IB (Cement Option) Combined Concrete Curb & Gutter, Barrier, Dry, Modified Concrete Center Curb, Type D LEGEND K1 R 14 15 16 18 19 26 Concrete Sidewalk, 4"F Varies 11'-0" to 24'-11" Lane Varies Varies 11'-0" to 26'-7" Lane2'-7"2'-7" Grade As Shown On Profile Grade As Shown On Profile 2%2% 2%2% K1 18 26 18 K1 Varies TYPICAL CROSS SECTION STA. 8+90.8 "S-1-B" to STA. 9+40.9 "S-1-B" Line "B" or "S-1-B"Varies UNDERDRAIN DETAIL 2'-0"1'-2"2'-0" 1.87' 2.0' TRUCK APRON RADIAL JOINT DETAIL RAB CENTER Concrete to be "Slate Green" color. Concrete to be broom finished perpendicular to road. D-1 contraction joints to fall at tooled joints. (No greater than 14' apart) 2% 2'-7" 2'-0"7" 1"6"2"R1"R 2%7"8"1'-1"2'-7" 2'-0"7" 1"6"2"R1"R 2%7"8"1'-1"1'-2"1" Aggregate for Underdrain Geotextile for Underdrain, Type 1AVariesPipe, Type 4, Circular, 6" K2% C2 UNDERDRAIN DETAIL AT ROUNDABOUT 16 165#/Syd. HMA Surface, Type B, on 275#/Syd. HMA Intermediate, Type B, on P 6" Compacted Aggregate No. 53, on Subgrade Treatment Type III HMA for Sidewalk Varies 12' to 13' TYPICAL CROSS SECTION R R STA. 14+95.30 "B" to STA. 21+39.10 "B" Varies 14' to 15' 1' Line "B" App. Centerline 11' Lane Grade As Shown On Profile TYPICAL CROSS SECTION 11' Lane K1 2%2%K1 STA. 32+69.30 "B" to STA. 35+29.80 "B" 2% 8'-0"2'-0" Line "C" & Profile Grade TYPICAL CROSS SECTION 18'-0" C2 K12% 16 STA. 0+00 "C" to STA. 2+63.89 "C" Underdrain (See Detail) Varies 0'0" to 9'-4"32'-0" Center Circle 6 in. of Compacted Aggregate No. 53, on Subgrade Treatment Type IB (Cement Option) Varies 0'-0" to 11'-0"Varies 0'-0" to 11'-0" Line "B" 26 Varies: 11' to 23.5' TYPICAL CROSS SECTION R R STA. 50+39.01 "B" to STA. 50+63.54 "B" STA. 6+84 "S-1-B" to STA. 8+21 "S-1-B" STA. 12+19 "S-1-B" to STA. 12+30 "S-1-B" Varies: 7' to 20.5' Line "B" or "S-1-B" STA. 10+60.1 "S-1-B" to STA. 11+10.3 "S-1-B" STA. 46+67.70 "B" to STA. 47+60 "B" STA. 48+80 "B" to STA. 49+25 "B" Varies: 14' to 28' Grade As Shown On Profile TYPICAL CROSS SECTION K1 2%2%K1 Line "B" or "S-1-B" Varies: 8' to 22' STA. 49+25.00 "B" to STA. 50+39.01 "B" STA. 8+21 "S-1-B" to STA. 8+90.80 "S-1-B" STA. 11+10.30 "S-1-B" to STA. 12+19.06 "S-1-B" 2'-7" 15 1'-6" Appurtenance Free Zone 10' Clear Zone 4:1 26 5'-0" 1.5%F26 6' 2'-7" 15 1'-6" Appurtenance Free Zone 10' Clear Zone 2' if P 0' if F 4:1 26 1.5% F26 6'2'-7" 15 1'-6" Appurtenance Free Zone 10' Clear Zone 2' 4:1 26 1.5%P 26 Varies 4'-0" to 6'-0"5'-0", 8'-0", or 10'-0" F or 2'-7" 15 1'-6" Appurtenance Free Zone 10' Clear Zone 2' 4:1 26 1.5%P 26 Varies 4'-0" to 6'-0"5'-0", 8'-0", or 10'-0" F or 2'-7" 15 1'-6" Appurtenance Free Zone 10' Clear Zone 2' 4:1 26 1.5% P 26 Varies 4'-0" to 6'-0"5'-0", 8'-0", or 10'-0" F or 2'-7" 15 1'-6" Appurtenance Free Zone 10' Clear Zone 4:1 26 5'-0" 1.5%F26 6' 2'-7" 15 1'-6" Appurtenance Free Zone 10' Clear Zone 4:1 26 5'-0" 1.5% F26 6' 14 1' 14 1'26 D+4 1/8"D 14" R. 14" R.4"3/8" 24"5/8" ROLL CURB, MODIFIED 16 8'-0" 1.5%P26 5'-0" 5'-0", 8'-0" or 10'-0" Por STA. 35+29.80 "B" to STA. 36+33.70 "B"STA. 21+39.10 "B" to STA. 22+47.80 "B" STA. 22+93.10 "B" to STA. 24+03.10 "B" STA. 28+12.50 "B" to STA. 29+51.90 "B" STA. 31+45.30 "B" to STA. 32+69.30 "B" STA. 38+08.80 "B" to STA. 39+27.10 "B" STA. 42+68.70 "B" to STA. 43+63.10 "B" STA. 44+57.20 "B" to STA. 45+18.20 "B" STA. 45+64.20 "B" to STA. 46+67.70 "B" Varies STA. 21+51.90 "B" to STA. 31+45.30 "B" STA. 22+47.80 "B" to STA. 22+93.01 "B" STA. 24+03.10 "B" to STA. 28+12.50 "B" STA. 39+27.10 "B" to STA. 42+68.70 "B" STA. 43+63.20 "B" to STA. 44+63.20 "B" STA. 45+27.20 "B" to STA. 45+64.20 "B" STA. 36+33.70 "B" to STA. 38+08.80 "B" Subgrade Treatment, Type IB Pipe, Type 4, Circular, 6 in. Aggregate for Underdrain 6" 4" 7" Geotextile for Underdrain, Type 1A Geotextile for Underdrain, Type 1A (Required at Curb Installation) 4:1 Varies Varies 4:1 4:1 STD. DITCH LT. STA. 22+22 "B" to STA. 26+55 "B" 3'-0" (Typ) 9" (Typ) STD. DITCH RT. STA. 32+75 "B" to STA. 33+91 "B" 6' (Typ) 1.5' Typ 4:1 9.5 (Typ) 2.3' Typ STD. DITCH RT. STA. 40+50 "B" to STA. 42+62 "B" CURB & GUTTER, BARRIER, MODIFIED CURB & GUTTER, BARRIER, DRY, MODIFIED 15 18 DIRECTORY PATH: R:\Active\Carmel\Guilford Road Des. No. 1383180\CAD\PlansFILENAME: TYPSEC.dwgDATE/USER: 7/31/2018 10:26 AM / AwolfTYPICAL CROSS SECTIONS N/A N/A 3A.J.W. RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALEINDIANA DEPARTMENT OF TRANSPORTATION M.B. A.P. M.B. 4/2/2018 VERTICAL SCALE 1383180 1383180 R-36906 76ERR 1 SEFSPRO NO. ASTATE OF D NIO IN LA AI N 01306 NGINE 27 EERIGEETS DANDREW JOHN W O LF Sec. 36, T18N, R3E Clay Township Hamilton County12+0013+0014+0015+0016+0017+0018+0019+0020+0021+0022+0023+0024+0025+0011+00TWIN LAKES APARTMENTS OF CARMEL LLC NEW BUFFALO LAND IMPROVEMENT JANET PICKERING WALTER GUILFORD COMMONS LLC HUNT LAKES OF CARMEL LLC LOTUS REALITY LLC S. GUILFORD ROAD Line "B" PHASE I OF TIMBER RIDGE HORIZONTAL PROPERTY REGIME PHASE II OF TIMBER RIDGE HORIZONTAL PROPERTY REGIME W. CITY CENTER DRIVEWATERLILY WAYW. 126th ST.App. Exist. R/W App. Exist. R/W Sec. 36, T18N, R3E Clay Township Hamilton County Sec. 25, T18N, R3E Clay Township Hamilton County Sec. 25, T18N, R3E Clay Township Hamilton CountySection LineSection LineApp. Exist. R/WApp. Exist. R/WApp. Exist. R/WApp PLApp. Exist. R/WApp PLBEGIN PROJECT 14+95.30 "B"Temp R/W App. Exist. R/W App. Exist. R/W A.J.W. RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALEINDIANA DEPARTMENT OF TRANSPORTATION M.B. A.P. M.B. 4/2/2018 VERTICAL SCALE 1383180 1383180 R-36906 76ERR 1 S EF SPRONO. ASTATE OF D NIO IN LA AI N 01306 NGINE 27 EERIGEETS DANDREW J OHN W OLFDIRECTORY PATH: R:\Active\Carmel\Guilford Road Des. No. 1383180\CAD\PlansFILENAME: PLAT-1.dwgDATE/USER: 3/28/2018 5:24 PM / ApercifieldPLAT NO. 1 1"=50'MATCH LINE 26+00 "B"4 27+0028+0029+0030+0031+0032+0033+0034+0035+0036+0037+0038+0039+0040+001802 CONDO LLC FRANK ANTHONY & KAREN S. RUTKKOWSKI RYAN D. MCHOME CARRIE E. STOCK DAVID M. & ANGELA E. CONCANNON PAUL J. MILLERJULIE M. WEBB EQUITY TRUST COMPANY CUSTODIAN FBO DAVID M. WALTERS MICHAEL D. & CAROL L. KEEN AMARJIT & BALWINDER KAUR h&w SINGH CARMEL CLAY SCHOOLS TWIN LAKES APARTMENTS OF CARMEL LLC S. GUILFORD ROAD Line "B" CARMEL 2002 SCHOOL BUILDING CORPORATION CARMEL CLAY SCHOOLS HELEN KEEN CT.COLLEGE WAYEMERSON RD.App. Exist. R/W App. Exist. R/WApp. Exist. R/WApp. Exist. R/W Sec. 25, T18N, R3E Clay Township Hamilton County Sec. 25, T18N, R3E Clay Township Hamilton CountyCHIMNEY ROCK DR.GRAND BLVD.CARMEL CLAY SCHOOLS App. Exist. R/WApp. Exist. R/WWILSON VILLAGE CONDOMINIUMS App. Exist. R/W App PLApp PLApp PLApp. Exist. R/WApp. Exist. R/WApp. Exist. R/WApp. Exist. R/WApp PLApp PLApp PLApp PLApp PLApp. Exist. R/W App PLApp PLApp PLR/W Temp R/W Temp R/W Temp R/W Temp R/W App. Exist. R/W Temp R/W Temp R/W Temp R/W Temp R/W R/W LITTLE CO O L CREEK LITTLE COOLCREEKA p p . E x i s t . R /W R/WApp. Exist. R/W Temp R/W Perpetual Drainage Easement R/WApp. Exist. R/W App. Exist. R/W App. Exist. R/W A.J.W. RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALEINDIANA DEPARTMENT OF TRANSPORTATION M.B. A.P. M.B. 4/2/2018 VERTICAL SCALE 1383180 1383180 R-36906 76ERR 1 S EF SPRONO. ASTATE OF D NIO IN LA AI N 01306 NGINE 27 EERIGEETS DANDREW J OHN W OLFDIRECTORY PATH: R:\Active\Carmel\Guilford Road Des. No. 1383180\CAD\PlansFILENAME: PLAT-1.dwgDATE/USER: 3/28/2018 5:24 PM / Apercifield1"=50'MATCH LINE 26+00 "B"5 MATCH LINE 41+00 "B"PLAT NO. 1 42+0043+0044+0045+0046+0047+0048+0049+0050+0051+0052+0053+00AUBREY S. & JANIE D. NARAINE TERESA ANN KANE MAIN & GUILFORD PLAZA LLC MIG GUILFORD RESERVE LLC S. GUILFORD ROAD Line "B"DRUID HILL DR.WILSON TERRACE CT.W. MAIN ST.CARMEL CLAY SCHOOLS SHOTZIE LLC MATT D. MITCHEL App. Exist. R/W App. Exist. R/W Sec. 25, T18N, R3E Clay Township Hamilton County Sec. 25, T18N, R3E Clay Township Hamilton County STANLEY A. & ANGELA D. HUNNICUTT MELNICHEK, VLADIMIR & TATIANA FRANK B. DIXON AMERICAN LEGION POST 155 Sec. 25, T18N, R3E Clay Township Hamilton County ALTA JANE ROTHFUSS TRUSTEE OF ALTA JANE ROTHFUSS REV TRUST JAMES & PAULA S. QUINN Line "S-1-B"8+00 7+00 6+00 9+00 11+00GUILFORD TRAIL DR.1+002+00 Line "C" WILSON VILLAGE CONDOMINIUMS WILSON VILLAGE CONDOMINIUMS GUILFORD TRAIL TOWNHOMESApp PLApp PLApp. Exist. R/W App. Exist. R/WApp. Exist. R/WApp. Exist. R/WApp. Exist. R/W App. Exist. R/W App. Exist. R/WApp. Exist. R/WApp PLApp PLApp PLApp PLApp. Exist. R/WApp PLApp PL W. MAIN ST.Line "S-1-B"END INCIDENTAL CONSTRUCTION 50+63.54 "B" END PROJECT 50+39.01 "B" BEGIN INCIDENTAL CONSTRUCTION 6+83.34 "S-1-B" BEGIN PROJECT 8+20.75 "S-1-B" END PROJECT 12+19.06 "S-1-B" END INCIDENTAL CONSTRUCTION 12+29.06 "S-1-B" 12+00 13+00 14+00 P.O.T. 48+20.44 "B" = P.O.T. 10+00.00 "S-1-B" Temp R/W Temp R/W Temp R/W Temp R/W R/W R/ W R /WR/W Temp R/W R/W R/W R/WA.J.W. RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALEINDIANA DEPARTMENT OF TRANSPORTATION M.B. A.P. M.B. 4/2/2018 VERTICAL SCALE 1383180 1383180 R-36906 76ERR 1 S EF SPRONO. ASTATE OF D NIO IN LA AI N 01306 NGINE 27 EERIGEETS DANDREW J OHN W OLFDIRECTORY PATH: R:\Active\Carmel\Guilford Road Des. No. 1383180\CAD\PlansFILENAME: PLAT-1.dwgDATE/USER: 3/28/2018 5:24 PM / Apercifield1"=50'MATCH LINE 41+00 "B"6PLAT NO. 1 DIRECTORY PATH: R:\Active\Carmel\Guilford Road Des. No. 1383180\CAD\PlansFILENAME: MOT-DETOUR.dwgDATE/USER: 7/31/2018 5:40 PM / AwolfA.J.W. RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALEINDIANA DEPARTMENT OF TRANSPORTATION M.B. A.P. M.B. 4/2/2018 VERTICAL SCALE 1383180 1383180 R-36906 76ERR 1 SEFSPRO NO. ASTATE OF D NIO IN LA AI N 01306 NGINE 27 EERIGEETS DANDREW J OHN W O L FMAINTENANCE OF TRAFFIC DETOUR ROUTE - PHASE 1 7 NTS NTS XM4-10(L) R11-3XM4-10(R) R11-3 R11-3 R11-2 R11-2 CLOSED ROAD CONSTRUCTION SIGNS, TYPE "A" AHEAD DETOUR AHEAD XW20-3 36" X 36" XW20-2 36" X 36" XW20-1 36" X 36" CONSTRUCTION ROAD R11-3 XM4-10(L) R11-3XM4-10(R) (G) (M) (G) (G) R11-3XM4-10(R) (G) (M)(M) (M)(G) (M)(G)(M)(G) (M)(G) (M)(G) (M)(G) (M)(G) (M) (G) (M) (M) (M) (G) (G) (G) (G) (G) (M) (M) (M) (M)(M)(M) (M)(M)(M) (M) (M)(M) (M) XM4-10(L) (M) R11-3 (G) (M)(G) (M)(G) R11-2 R11-2 R11-2 R11-2 CONSTRUCTION SIGNS, TYPE "A" CLOSED GUILFORD RD. AT MAIN ST. CLOSED MAIN STREET AT GUILFORD RD. CLOSED ROAD AHEAD DETOUR AHEAD XW20-3 36" X 36" XW20-2 36" X 36" XW20-1 36" X 36" CONSTRUCTION ROAD DIRECTORY PATH: R:\Active\Carmel\Guilford Road Des. No. 1383180\CAD\PlansFILENAME: MOT-DETOUR.dwgDATE/USER: 7/31/2018 5:40 PM / AwolfA.J.W. RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALEINDIANA DEPARTMENT OF TRANSPORTATION M.B. A.P. M.B. 4/2/2018 VERTICAL SCALE 1383180 1383180 R-36906 76ERR 1 S EF SPRONO. ASTATE OF D NIO IN LA AI N 01306 NGINE 27 EERIGEETS DANDREW J OHN W O L FMAINTENANCE OF TRAFFIC DETOUR ROUTE - ROUNDABOUT CLOSURE 8 NTS NTS R11-3XM4-10(L) R11-3XM4-10(R) R11-2 R11-2 R11-2 R11-2 R11-3 R11-2 R11-2 CONSTRUCTION SIGNS, TYPE "A" CLOSED ROAD AHEAD DETOUR AHEAD XW20-3 36" X 36" XW20-2 36" X 36" XW20-1 36" X 36" CONSTRUCTION ROAD DIRECTORY PATH: R:\Active\Carmel\Guilford Road Des. No. 1383180\CAD\PlansFILENAME: MOT-DETOUR.dwgDATE/USER: 7/31/2018 5:40 PM / AwolfA.J.W. RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALEINDIANA DEPARTMENT OF TRANSPORTATION M.B. A.P. M.B. 4/2/2018 VERTICAL SCALE 1383180 1383180 R-36906 76ERR 1 S EF SPRONO. ASTATE OF D NIO IN LA AI N 01306 NGINE 27 EERIGEETS DANDREW J OHN W O L FMAINTENANCE OF TRAFFIC DETOUR ROUTE - PHASE 2 9 NTS NTS A.J.W. RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALEINDIANA DEPARTMENT OF TRANSPORTATION M.B. A.P. M.B. 4/2/2018 VERTICAL SCALE 1383180 1383180 R-36906 76ERR 1 S EF SPRONO. ASTATE OF D NIO IN LA AI N 01306 NGINE 27 EERIGEETS DANDREW J OHN W O L FMATCHLINE STA. 35+0036+00MATCHLINE STA. 35+0037+0038+0039+0040+0041+0042+0043+0044+0045+0046+0047+0048+0049+0022+0023+0024+0025+0026+0027+0028+0029+0030+0031+0032+0033+0034+0021+00GUILFORD ROAD WATERLILY WAYCHIMNEY ROCK DRHELEN KEEN CTCOLLEGE WAYSCHOOLENTRANCEGRAND BLVDEMERSON ROAD126TH STSCHOOLENTRANCESCHOOLENTRANCEGUILFORD ROAD 47+00MAINTENANCE OF TRAFFIC PHASE 1 10 DIRECTORY PATH: R:\Active\Carmel\Guilford Road Des. No. 1383180\CAD\PlansFILENAME: MOT-PHASING.dwgDATE/USER: 7/31/2018 5:37 PM / Awolf1"=50' N/AW. MAIN STREETW. MAIN STREETGENERAL LEGEND WORK AREA TYPE III BARRICADE ROAD CLOSURE SIGN ASSEMBLY R9-92' X 1'WILSON TERRACE CTDRUID HILL DR(NO OUTLET-14 DUPLEXES)(NO OUTLET-CONDO COMMUNITY)GUILFORD TRAIL DR(NO OUTLET- MUTI-UNIT HOUSING)COMMERCIAL ENTRANCE(ALTERNATE ACCESS FROM W. MAIN ST)GUILFORD ROAD MAINTAIN ACCESSMAINTAIN ACCESSMAINTAIN ACCESSR9-9 R9-9 A.J.W. RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALEINDIANA DEPARTMENT OF TRANSPORTATION M.B. A.P. M.B. 4/2/2018 VERTICAL SCALE 1383180 1383180 R-36906 76ERR 1 S EF SPRONO. ASTATE OF D NIO IN LA AI N 01306 NGINE 27 EERIGEETS DANDREW J OHN W O L FMATCHLINE STA. 35+0036+00MATCHLINE STA. 35+0037+0038+0039+0040+0041+0042+0043+0044+0045+0046+0047+0048+0049+0022+0023+0024+0025+0026+0027+0028+0029+0030+0031+0032+0033+0034+0021+00GUILFORD ROAD WATERLILY WAYCHIMNEY ROCK DRHELEN KEEN CTCOLLEGE WAYSCHOOLENTRANCEGRAND BLVDEMERSON ROAD126TH STSCHOOLENTRANCESCHOOLENTRANCEGUILFORD ROAD 47+00MAINTENANCE OF TRAFFIC PHASE 1 - ROUNDABOUT CLOSURE 11 DIRECTORY PATH: R:\Active\Carmel\Guilford Road Des. No. 1383180\CAD\PlansFILENAME: MOT-PHASING.dwgDATE/USER: 7/31/2018 5:37 PM / Awolf1"=50' N/AMAINTAIN ACCESSMAINTAIN ACCESSMAINTAIN ACCESSW. MAIN STREETW. MAIN STREETGENERAL LEGEND WORK AREA R9-9 R9-9 R9-9 TYPE III BARRICADE ROAD CLOSURE SIGN ASSEMBLY R9-92' X 1'WILSON TERRACE CTDRUID HILL DR(NO OUTLET-14 DUPLEXES)(NO OUTLET-CONDO COMMUNITY)GUILFORD TRAIL DR(NO OUTLET- MUTI-UNIT HOUSING)COMMERCIAL ENTRANCE(ALTERNATE ACCESS FROM W. MAIN ST)GUILFORD ROAD MAINTAIN ACCESSMAINTAIN ACCESSMAINTAIN ACCESSR9-9 A.J.W. RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALEINDIANA DEPARTMENT OF TRANSPORTATION M.B. A.P. M.B. 4/2/2018 VERTICAL SCALE 1383180 1383180 R-36906 76ERR 1 S EF SPRONO. ASTATE OF D NIO IN LA AI N 01306 NGINE 27 EERIGEETS DANDREW J OHN W O L FMATCHLINE STA. 35+00MATCHLINE STA. 35+0022+0023+0024+0025+0026+0027+0028+0029+0030+0031+0032+0033+0034+0021+00GUILFORD ROAD WATERLILY WAYCHIMNEY ROCK DRHELEN KEEN CTCOLLEGE WAYSCHOOLENTRANCEGRAND BLVDEMERSON ROADWILSON TERRACE CTDRUID HILL DR126TH STGUILFORD TRAIL DRW. MAIN STREETGUILFORD ROADSCHOOLENTRANCESCHOOLENTRANCEGUILFORD ROAD MAINTENANCE OF TRAFFIC PHASE 2 12 DIRECTORY PATH: R:\Active\Carmel\Guilford Road Des. No. 1383180\CAD\PlansFILENAME: MOT-PHASING.dwgDATE/USER: 7/31/2018 5:37 PM / Awolf1"=50' N/AMAINTAIN ACCESS FROMEMERSON ROAD(CLOSED)(NO OUTLET-8 HOUSES)ACCESS TO SCHOOL ONLYMAINTAIN ACCESSMAINTAIN ACCESSMAINTAIN ACCESSMAINTAIN ACCESSMAINTAIN ACCESSMAINTAIN ACCESSMAINTAIN ACCESS(CLOSED)MAINTAIN ACCESS(CLOSED)(CLOSED)(CLOSED)(CLOSED)ACCESS FROM WATERLILY WAYACCESS FROM SHERMAN DR36+0037+0038+0039+0040+0041+0042+0043+0044+0045+0046+0047+0048+0049+0047+00GENERAL LEGEND WORK AREA R9-9 R9-9 R9-9 R9-9 TYPE III BARRICADE ROAD CLOSURE SIGN ASSEMBLY R9-92' X 1'(CLOSED)ACCESS FROM CHIMNEY ROCK DR(CLOSED)ACCESS FROM GRAND BLVD Sec. 36, T18N, R3E Clay Township Hamilton County12+0013+0014+0015+0016+0017+0018+0011+00HUNT LAKES OF CARMEL LLC LOTUS REALITY LLC S. GUILFORD ROAD Line "B" PHASE I OF TIMBER RIDGE HORIZONTAL PROPERTY REGIME W. CITY CENTER DRIVEApp. Exist. R/W App. Exist. R/WApp. Exist. R/W (grass) (grass) (grass) Sec. 36, T18N, R3E Clay Township Hamilton County (conc walk)(bu s h e s ) (trees/grass)+74.5, 40.6', Guy Wire+90.6, 40.6', PP w/Riser+43.7, 50.0', 12" Dec.+48.1, 48.1', 6" Dec.+93.3, 48.4', 3" Dec.+99.6, 49.5', 9" Dec.+67.6, 40.6', PP w/Riser+79.5, 41.7', 6" Dec.+06.7, 49.8', Gas Marker+13.0, 45.5', Sprinkler Head+54.6, 23.0', 15" Dec.+50.1, 48.0', 12" Con.+08.6, 23.6', 24" Dec.+09.0, 37.0', Sprinkler Head+45.7, 18.0', 6" Dec.+36.3, 39.7', PP w/Riser+37.6, 39.4', Tele Box+85.9, 18.1', 9" Dec.+31.0, 18.8', 6" Dec.+64.6, 19.0', 6" Dec.+99.7, 19.5', 6" Dec.+26.7, 33.2', Rnd. Inlet+22.8, 49.3', 15" Dec.+71.6, 45.5', 36" Bush+72.8, 47.7', 36" Bush+73.7, 49.8', 36" Bush+76.0, 44.8', Air Cond.+78.4, 43.2', 24" Bush+77.5, 48.2', Air Cond.+80.1, 46.9', 24" Bush+02.8, 41.1', PP w/Riser+20.2, 14.3', Inlet+92.1, 22.0',Storm M.H.+53.6, 23.5',San. M.H.+95.1, 22.6',Storm M.H.+90.7, 33.8',6" Con.+22.5, 36.6',6" Con.+49.7, 33.2',6" Con.+73.8, 40.3',6" Con.+94.0, 37.2',6" Con.+22.5, 35.8',12" Dec.+54.1, 34.0',6" Dec.+71.9, 37.6',6" Dec.+87.1, 34.1',6" Dec.+97.5, 18.9',Sign (35 MPH)+10.3, 41.3',6" Con.+27.1, 18.8',6" Dec.+35.6, 32.2',6" Con.+60.5, 18.7',6" Dec.+63.8, 35.3',12" Dec.+95.0, 18.8',6" Dec.+94.5, 31.2',6" Con.+21.3, 36.2',6" Con.+28.0, 18.7',6" Dec.+37.4, 48.2',Elec. Box+55.5, 35.1',6" Con.+61.5, 18.9',6" Dec.+67.5, 35.1',6" Con.+79.7, 37.1',6" Con.+90.6, 18.9',6" Dec.+86.2, 44.5',6" Con.+98.3, 34.7',60" Bush+09.9, 40.2',60" Bush+23.5, 38.1',60" Bush+28.9, 19.3',9" Dec.+33.7, 48.9',48" Bush+56.4, 49.0',12" Dec.+61.9, 18.4',6" Dec.+89.7, 29.3',???+02.6, 18.5',6" Dec.+19.3, 15.6',Inlet+20.4, 19.6',Storm M.H.(Asph.) BEGIN PROJECT 14+95.30 "B" 12" Pipe 12" Pipe24" Pipe18" Pipe 18" Pipe 24" Pipe15" Pipe12" Pipe24" Pipe 12" Pipe12" Pipe15" Pipe18" Pipe(conc walk)App. Exist. R/WEasementEasementEasement EasementEasementApp PLConstr. Limits Easement (Asph.) (Asph.)+20.0, 35.8', 15" Dec.+81.2, 29.8', 15" Dec.Easement Proposed Grade Exist. & Proposed Grade @ Line "B" 11+00 12+00 13+00 14+00 15+00 16+00 17+00 18+00843.31843.49843.68843.86843.69843.49843.29843.15843.26843.49843.80844.12844.45844.78845.09845.41845.65846.07846.32846.30846.28846.20846.07845.93845.78845.63845.49845.31845.10844.84844.64844.49846.35846.42846.42846.35846.20846.00845.81845.62845.43845.23845.04844.85844.68844.59PVI STA: 15+48.50 PVI ELEV: 846.59 VCL: 105.00 PVI STA: 18+34.69 PVI ELEV: 844.39 Exist. Grade @ Line "B"846.35846.42846.42846.35846.20846.00845.81845.62845.43845.23845.04844.85844.68844.59BEGIN PROJECT STA. 14+95.30 "A" ELEV. = 846.33 -0.77% +0.50% PROPOSED LEGEND EXISTING Storm Manhole Gas Line Storm Inlets Sanitary Manhole Gas Valve Gas Meter Sanitary Cleanout Water Line Water Valve Fire Hydrant Sprinkler Electric Line Power Pole w/(Riser) Light & Power Pole Light & Power Pole w/Riser Water Meter Light Pole Guy Wire Electric Box Fiber Optic Line Telephone Line Telephone Manhole Cable TV Line Cable TV Box Telephone Riser Utility Manhole Wood Fence Iron Pin Sign Flag Pole Bush Tree Trunk Deciduous Tree Coniferous Tree Overhead Utility Line Wood Fence Wire Fence Chainlink Fence Iron Fence Irr. Valve Mailbox (A) CENTER OF WATER METER, 44.10' (A) MAG W/ WASHER FOUND ON W SIDE OF PP# 300184 UP 1.0', 99.79' (B) MAG W/ WASHER FOUND ON W SIDE OF PP# 300185 UP 1.0', 74.02' (C) MAG W/ WASHER FOUND ON E SIDE OF PP# 300186 UP 1.0', 91.20' (D) CENTER OF WATER VALVE, 48.50' (E) CENTER OF GAS VALVE, 60.60' (F) T.B.M. 473, CUT "X" ON NORTH BONNET BOLT OF HYD, 104.15' CONTROL POINT 173 (PIN WITH CAP) - O.P.O.T. STA. 21+91.78', 14.97' (R) LINE "B" N = 47558.1910 E = 60720.0750 (A) NW CRNR OF CURB INLET (ON BC), 29.25' (B) ON BC WHERE CONCRETE SIDEWALK EDGE MEETS CURB, 6.00' (C) SW CRNR OF CONCRETE SIDEWALK, 9.02' (D) CENTER OF TRAFFIC MH, 35.92' (E) NW CRNR OF CURB INLET (ON BC), 84.00' (F) NE CORNER OF CONCRETE SIDEWALK, 10.70' (G) SOUTHERNMOST CRNR OF METAL BOX UP 1.0, 14.95' (H) T.B.M. 478, CUT "X" INTO NNE BONNET BOLT OF HYD,N = 46407.9956 E = 60678.6862 CONTROL POINT 178 (MAG NAIL) - O.P.O.T. STA. 10+41.56', -26.96' (L) LINE "B" C.P. 178 GUILFORD RD.(A) (B)(C) (D)LINE "B"AMERICAN LEGION C.P. 173 (A)(B) (C) (D) GUILFORD RD. LINE "B"126th ST.(E)(F) WATERLILY WAY (E)(F) (G)(H) (A) MAG NAIL ON NW SIDE OF CONCRETE BASE OF TRAFFIC POLE, 13.34'LINE "B" All R/W and Topo from Line "B" Unless Noted Otherwise Removal (Pvmt, Sidewalk, Concrete) TBM #474 - Cut " " on SW Corner of Square Concrete Light Pole Foundation in Parking Lot at SE Corner of 852 W. Main St. Sta. 5+10.70 "S-1-B", 93.46' Lt., Elev. = 847.88' TBM #471 - Cut "X" on WNW Bonnet Bolt of Fire Hydrant. Sta. 39+12.52 "B", 26.67' Rt., Elev. = 836.47' TBM #472 - RR Spike set 1.0' up on W. face of Power Pole #185-562. Sta. 30+66.56 "B", 12.53' Rt., Elev. = 842.79' TBM #473 - Cut "X" on N Bonnet Bolt of Fire Hydrant. Sta. 22+78.42 "B", 42.79' Lt., Elev. = 844.99 TBM #478 -Cut "X" on NNE Bonnet Bolt of Fire Hydrant. Sta. 11+66.72 "B", 62.69' Rt., Elev. = 845.12' TBM #470 - Top of NW Corner of Bottom Porch Step Sta. 47+35.12 "B", 88.05' Rt., Elev. = 852.06' ORIGINATING BENCHMARK DESIGNATION - V 42 PID - LB0600 STATE/COUNTY - IN/HAMILTON USGS QUAD - WESTFIELD (1992) VERT ORDER - SECOND CLASS 0 DESCRIBED BY COAST AND GEODETIC SURVEY 1934 1.8 MILES SOUTH ALONG THE CHICAGO, INDIANAPOLIS AND LOUISVILLE RAILWAY FROM THE STATION AT WESTFIELD, HAMILTON COUNTY, 6 1 2 RAILS SOUTH OF CULVERT B-165.1 IN THE NORTHEAST ANGLE OF A GRAVEL ROAD, 9 YARDS EAST OF THE EAST RAIL, 6 YARDS NORTH OF THE CENTERLINE OF THE ROAD, AND ABOUT 3 FEET HIGHER THAN THE RAIL. A STANDARD DISK, STAMPED V 42 1934 AND SET IN THE TOP OF A CONCRETE POST PROJECTING ONE-HALF FOOT ABOVE GROUND. ELEVATION = 884.62 (NAVD 88) A.J.W. RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALEINDIANA DEPARTMENT OF TRANSPORTATION M.B. A.P. M.B. 4/2/2018 VERTICAL SCALE 1383180 1383180 R-36906 76ERR 1 S EF SPRONO. ASTATE OF D NIO IN LA AI N 01306 NGINE 27 EERIGEETS DANDREW J OHN W OLFDIRECTORY PATH: R:\Active\Carmel\Guilford Road Des. No. 1383180\CAD\PlansFILENAME: PP-B.dwgDATE/USER: 7/20/2018 4:25 PM / AwolfPLAN AND PROFILE LINE "B" 1"=30' 1"=5' 835 830 825 840 MATCH LINE 18+25 "B"845 850 855 13 835 830 825 840 845 850 855 EARTHWORK SUMMARY COMMON EX. = 8,975 CYD* FILL = 2,785 CYD FILL +25% = 3,480 CYD BORROW = 1,235 CYD *Assume 2,245 CYD useable Does not include pipe spoils. Raw Earthwork is calculated by section method up to the roundabout and then in Civil 3D by comparing the existing DEM to the Final DEM as shown on Sheets 43 and 44. 5,103 CYD asphalt pavement removal was estimated and is included in Common Excavation. 19+0020+0021+0022+0023+0024+0025+00HUNT LAKES OF CARMEL LLC TWIN LAKES APARTMENTS OF CARMEL LLC NEW BUFFALO LAND IMPROVEMENT JANET PICKERING WALTER GUILFORD COMMONS LLCPHASE II OF TIMBER RIDGE HORIZONTAL PROPERTY REGIME S. GUILFORD ROAD Line "B"WATERLILY WAYW. 126th ST.App. Exist. R/W App. Exist. R/W (grass) (grass) Sec. 25, T18N, R3E Clay Township Hamilton County Sec. 36, T18N, R3E Clay Township Hamilton County Sec. 36, T18N, R3E Clay Township Hamilton County Sec. 25, T18N, R3E Clay Township Hamilton County Section LineSection Line(trees) (trees) (grass)(conc walk)(grass) (grass)(asph)(asph)(conc walk) (asph path) T.B.M. 473 C.P. 173+29.8, 18.4', 6" Dec.+70.7, 48.9', 12" Dec.+89.1, 41.0', 48" Bush+88.8, 44.6', Yard Light+88.4, 46.2', 48" Bush+90.9, 44.5', 48" Bush+90.9, 42.1', 48" Bush+90.9, 40.0', 48" Bush+79.7, 44.8', 48" Bush+86.8, 42.4', 48" Bush+87.2, 40.1', 48" Bush+61.1, 40.9', PP w/Riser+64.6, 20.1', 6" Dec.+98.0, 20.2', 6" Dec.+70.5, 24.9', 24" Dec.+19.6, 37.9', Tele Box+19.6, 41.1', PP w/Riser+44.5, 41.2', Guy Wire+46.8, 41.5', Guy Wire+54.0, 42.0', Guy Wire+68.2, 50.2', 15" Dec.+84.1, 30.4', Sign (Stop)+87.1, 35.3', Storm M.H.+14.3, 35.2', San. M.H.+17.5, 40.4', Gas Vavle+17.2, 40.6', Gas Vavle+33.3, 39.2',???+46.0, 39.1',???+69.8, 42.5', 24" Stump+47.5, 23.0', 24" Dec.+77.7, 42.5', 24" Dec.+78.7, 45.3', Water Valve+86.6, 47.8', 9" Con.+07.8, 39.8', 18" Con.+19.4, 33.2', San. M.H.+25.2, 45.7', 12" Con.+30.8, 50.5', 15" Con.+53.5, 38.9', 6" Con.+63.6, 43.4', Water Valve+67.9, 47.1', 9" Con.+85.0, 47.3', 12" Con.+95.1, 44.3', 6" Con.+33.3, 46.4', 9" Con.+54.5, 44.5', 9" Con.+55.5, 46.3', 6" Con.+74.6, 34.7', 18" Con.+82.4, 44.1', 12" Con.+89.9, 29.5', Sign+09.8, 29.0', San. M.H.+16.1, 47.8', 15" Con.+37.6, 38.2', 15" Con.+73.2, 30.2', 12" Con.+71.8, 48.3', 18" Con.+98.5, 32.1', 3" Con.+29.6, 17.7',6" Dec.+64.1, 18.4',6" Dec.+93.5, 17.7',6" Dec.+93.7, 48.5',12" Dec.+27.7, 18.1',6" Dec.+63.3, 18.3',6" Dec.+96.9, 17.6',6" Dec.+09.9, 47.6',9" Con.+29.2, 18.7',6" Dec.+63.5, 17.9',6" Dec.+73.4, 29.6',Tele M.H.+78.2, 45.8',6" Con.+94.3, 27.0',???+94.5, 26.6',Guy Wire+99.1, 27.6',???+99.1, 27.4',Guy Wire+01.7, 27.7',???+02.1, 27.9',Guy Wire+04.9, 27.3',???+18.9, 27.9',PP w/Riser+20.8, 27.9',Tele Box+69.8, 15.0',Inlet+85.4, 30.1',Tele Box+92.5, 31.6',3" Con.+11.8, 45.4',48" Bush+17.9, 49.4',1" Dec.+29.7, 39.3',Guy Wire+47.7, 44.3',3" Dec.+73.4, 44.5',3" Dec.+91.0, 27.4',PP w/Riser+06.3, 48.4',6" Dec.+10.3, 41.8',Yard Light+18.1, 48.2',Yard Light+24.1, 39.6',Gas Vavle+25.0, 39.8',Gas Marker+26.5, 44.0',Irr. Valve+69.6, 39.6',Sign (Stop)+59.1, 27.3',Power Pole+64.7, 17.9',Sign (35 MPH)+57.8, 41.1',Irr. ValveN0°01'40"W P.I. STA: 21+85.45 (No Curve) N0°06'57"E 12" Pipe1 2 " P i p e 10" San.12" San.6" San.12" San. 12" San.8" San.Easement Easement EasementApp. Exist. R/WApp PL(asph path) App. Exist. R/W Constr. Limits Constr. Limits Constr. LimitsConstr. Limits Temp R/W for Drive Const. Easement Easement Easement +22 "B" PL(39') +25 "B" 81'+71 "B" 81' +71 "B" PL(39') 12" Pipe 12" PipeStr. No. 23 Str. No. 21 Str. No. 22A Str. No. 21A Str. No. 22 Str. No. 27 Str. No. 20 Str. No. 25 Str. No. 26 Str. No. 24 91°7'5" 88°46'54"91°4'29" 89°1'32" Proposed Grade Exist. Grade @ Line "B" 19+00 20+00 21+00 22+00 23+00 24+00 25+00 26+00844.49844.52844.59844.74844.92845.06845.14845.16845.12844.97844.71844.43844.11843.77843.39843.21843.29843.38843.51843.66843.81843.92843.84843.61843.17842.58841.90841.32840.86840.63840.46840.34844.59844.56844.61844.72844.84844.97845.09845.16845.12844.97844.73844.42844.12843.82843.58843.44843.40843.46843.58843.71843.83843.87843.76843.51843.12842.58842.01841.51841.09840.75840.48840.29PVI STA: 20+25.03 PVI ELEV: 845.34 VCL: 105.00 PVI STA: 23+86.00 PVI ELEV: 844.14 VCL: 130.00 PVI STA: 18+34.69 PVI ELEV: 844.39 VCL: 112.00 PVI STA: 22+00.00 PVI ELEV: 843.20 VCL: 112.00 PVI STA: 25+76.32 PVI ELEV: 839.51 VCL: 250.00 844.59844.56844.61844.72844.84844.97845.09845.16845.12844.97844.73844.42844.12843.82843.58843.44843.40843.46843.58843.71843.83843.87843.76843.51843.12842.58842.01841.51841.09840.75840.48840.2921"∅ PIPE @ 0.30%18"∅ PIPE @ 0.30% INV. = 835.60 INV. = 836.45 INV. = 835.60 21" Str. No. 23 Str. No. 27 +22.16 841.42 +39.75 842.51 Std. Ditch Lt. 9" Deep. 5.5% Str. No. 20 15"∅ PIPE @ 0.50% +0.51% +0.50%-1.22% -2.44% All R/W and Topo from Line "B" Unless Noted Otherwise PROPOSED (See Typical Sheet for Additional Details) Concrete Curb (Barrier)14 Mill and OverlayR 15 Sodding26 16 LEGEND EXISTING Storm Manhole Gas Line Storm Inlets Sanitary Manhole Gas Valve Gas Meter Sanitary Cleanout Water Line Water Valve Fire Hydrant Sprinkler Electric Line Power Pole w/(Riser) Light & Power Pole Light & Power Pole w/Riser Water Meter Light Pole Guy Wire Electric Box Fiber Optic Line Telephone Line Telephone Manhole Cable TV Line Cable TV Box Telephone Riser Utility Manhole Wood Fence Iron Pin Sign Flag Pole Bush Tree Trunk Deciduous Tree Coniferous Tree Overhead Utility Line Wood Fence Wire Fence Chainlink Fence Iron Fence Irr. Valve Mailbox Concrete Sidewalk, 4"F 18 Concrete Center Curb, Type 'D'19 Combined Concrete Curb & Gutter (Barrier) Modified Roll Curb Combined Concrete Curb & Gutter (Barrier) (Dry) Concrete Curb Ramp C2 PCCP, 7" with D-1 Contraction Joints Spaced at 14' Max. HMA for SidewalkP Asphalt ShoulderJ C PCCP, For Approaches 6" on Subgrade Treatment Type II. H C1 PCCP, For Approaches 9" on Subgrade Treatment Type II. Retaining WallW Full Depth Asphalt PavementK1 Removal (Pvmt, Sidewalk, Concrete) D HMA For Approaches (See Typical Sheet for Additional Details) TBM #474 - Cut " " on SW Corner of Square Concrete Light Pole Foundation in Parking Lot at SE Corner of 852 W. Main St. Sta. 5+10.70 "S-1-B", 93.46' Lt., Elev. = 847.88' TBM #471 - Cut "X" on WNW Bonnet Bolt of Fire Hydrant. Sta. 39+12.52 "B", 26.67' Rt., Elev. = 836.47' TBM #472 - RR Spike set 1.0' up on W. face of Power Pole #185-562. Sta. 30+66.56 "B", 12.53' Rt., Elev. = 842.79' TBM #473 - Cut "X" on N Bonnet Bolt of Fire Hydrant. Sta. 22+78.42 "B", 42.79' Lt., Elev. = 844.99 TBM #478 -Cut "X" on NNE Bonnet Bolt of Fire Hydrant. Sta. 11+66.72 "B", 62.69' Rt., Elev. = 845.12' TBM #470 - Top of NW Corner of Bottom Porch Step Sta. 47+35.12 "B", 88.05' Rt., Elev. = 852.06' ORIGINATING BENCHMARK DESIGNATION - V 42 PID - LB0600 STATE/COUNTY - IN/HAMILTON USGS QUAD - WESTFIELD (1992) VERT ORDER - SECOND CLASS 0 DESCRIBED BY COAST AND GEODETIC SURVEY 1934 1.8 MILES SOUTH ALONG THE CHICAGO, INDIANAPOLIS AND LOUISVILLE RAILWAY FROM THE STATION AT WESTFIELD, HAMILTON COUNTY, 6 1 2 RAILS SOUTH OF CULVERT B-165.1 IN THE NORTHEAST ANGLE OF A GRAVEL ROAD, 9 YARDS EAST OF THE EAST RAIL, 6 YARDS NORTH OF THE CENTERLINE OF THE ROAD, AND ABOUT 3 FEET HIGHER THAN THE RAIL. A STANDARD DISK, STAMPED V 42 1934 AND SET IN THE TOP OF A CONCRETE POST PROJECTING ONE-HALF FOOT ABOVE GROUND. ELEVATION = 884.62 (NAVD 88) (A) CUT "X" ON EAST EDGE OF RIM OF MH, 34.65' (B) MAG NAIL SET ON NORTH SIDE OF PP #186034 UP 1.0', 49.95' (C) CUT NOTCH ON W SIDE OF PED CROSSING PIC POST UP 1.0', 38.37' (D) T.B.M. 411, SET RR SPIKE ON W SIDE OF PP# 185562 UP 1.0', 60.27' N = 48483.4849 E = 60686.5859 CONTROL POINT 172 (MAG NAIL) - O.P.O.T. STA. 31+17.00', -20.39' (L) LINE "B" (A) MAG W/ WASHER FOUND ON W SIDE OF PP# 300184 UP 1.0', 99.79' (B) MAG W/ WASHER FOUND ON W SIDE OF PP# 300185 UP 1.0', 74.02' (C) MAG W/ WASHER FOUND ON E SIDE OF PP# 300186 UP 1.0', 91.20' (D) CENTER OF WATER VALVE, 48.50' (E) CENTER OF GAS VALVE, 60.60' (F) T.B.M. 473, CUT "X" ON NORTH BONNET BOLT OF HYD, 104.15' CONTROL POINT 173 (PIN WITH CAP) - O.P.O.T. STA. 21+91.78', 14.97' (R) LINE "B" N = 47558.1910 E = 60720.0750 (B) ON BC WHERE CONCRETE SIDEWALK EDGE MEETS CURB, 6.00' C.P. 172 (A) (B) (C)(D) GUILFORD RD. LINE "B" COLLEGE CARMEL MIDDLE SCHOOL WAY C.P. 173 (A)(B) (C) (D) GUILFORD RD. LINE "B"126th ST.(E)(F) WATERLILY WAY (A) MAG NAIL ON NW SIDE OF CONCRETE BASE OF TRAFFIC POLE, 13.34'LINE "B" A.J.W. RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALEINDIANA DEPARTMENT OF TRANSPORTATION M.B. A.P. M.B. 4/2/2018 VERTICAL SCALE 1383180 1383180 R-36906 76ERR 1 S EF SPRONO. ASTATE OF D NIO IN LA AI N 01306 NGINE 27 EERIGEETS DANDREW J OHN W OLFDIRECTORY PATH: R:\Active\Carmel\Guilford Road Des. No. 1383180\CAD\PlansFILENAME: PP-B.dwgDATE/USER: 7/20/2018 4:25 PM / AwolfPLAN AND PROFILE LINE "B" 1"=30' 1"=5' 835 830 825 840 MATCH LINE 26+00 "B"845 850 855 14 835 830 825 840 845 850 855MATCH LINE 18+25 "B" 27+0028+0029+0030+0031+0032+0033+001802 CONDO LLCJULIE M. WEBB EQUITY TRUST COMPANY CUSTODIAN FBO DAVID M. WALTERS MICHAEL D. & CAROL L. KEEN AMARJIT & BALWINDER KAUR h&w SINGH CARMEL CLAY SCHOOLS GUILFORD COMMONS LLC TWIN LAKES APARTMENTS OF CARMEL LLC S. GUILFORD ROAD Line "B" CARMEL CLAY SCHOOLS HELEN KEEN CT.COLLEGE WAYApp. Exist. R/WApp. Exist. R/W Sec. 25, T18N, R3E Clay Township Hamilton County Sec. 25, T18N, R3E Clay Township Hamilton County (conc. walk) (conc. walk) (asph. path) (grass) (grass) (lawn) (lawn) (lawn) (lawn)(lawn)(grass)+01,20'(asph)CHIMNEY ROCK DR.+35,22'(asph)+84,55'(asph)+90,12'(asph)+54,12'(conc)+53,15'(asph)+16,30'(conc.) (asph)+08,44'(asph)+57,16'(asph)(conc)(conc walk)(conc walk)(conc walk)(conc. walk)(conc)(conc walk)(asph. path) (grass)(grass) T.B.M. 472 C.P. 172+08.8, 49.0', 18" Con.+19.7, 29.7', 15" Con.+32.0, 40.5', 12" Con.+52.5, 43.4', 18" Con.+72.4, 49.3', 3" Con.+92.6, 47.0', 3" Con.+95.1, 16.4', Sign+16.3, 22.8', Rnd. Inlet+26.7, 30.2', 6" Con.+45.6, 35.9', Water Valve+48.8, 37.5', Water Valve+51.4, 34.6', Water Valve+63.3, 34.5', Water Valve+81.3, 27.4', San. M.H.+83.9, 32.6', Fire Hyd.+85.4, 34.6', Water Valve+83.0, 48.6', 6" Con.+03.2, 21.5', Storm M.H.+31.9, 37.5', Sign+32.5, 37.1', Sign+35.6, 35.7',???+36.8, 38.0',???+39.1, 38.9',???+39.2, 42.2', Power Pole+38.0, 44.2', Tele Box+43.8, 48.9', Sign (Stop)+64.2, 22.9', San. M.H.+50.1, 23.6', Inlet+66.9, 22.2',???+67.3, 24.6', Power Pole+87.7, 39.3', Storm M.H.+76.9, 44.4', Sign (Stop)+15.3, 12.4', San. M.H.+48.0, 46.3', Water Valve+63.6, 41.3', Water Valve+67.2, 44.2', 6" Dec.+00.3, 45.5', 6" Dec.+35.9, 45.8', 6" Dec.+68.4, 44.8', 6" Dec.+70.5, 23.4', Inlet+04.6, 15.9',???+20.5, 26.4',Power Pole+56.7, 24.5',Rnd. Inlet+85.5, 49.8',Irr. Valve+03.1, 47.2',Sq. Inlet+16.7, 28.5',Storm M.H.+13.8, 40.4',Sign (Stop)+22.6, 36.8',Tele Box+36.8, 21.9',Sign+37.1, 24.1',3" Dec.+36.9, 26.0',Sign (25 MPH)+41.6, 30.0',Water Meter+73.8, 20.8',Mailbox+75.0, 45.1',6" Dec.+89.0, 26.4',3" Dec.+05.9, 26.1',PP w/Riser+22.1, 23.0',???+34.9, 23.9',Mailbox+62.3, 37.8',Water Meter+93.0, 24.8',Sign (25 MPH)+86.1, 50.3',18" Dec.+20.1, 48.1',Sign+25.7, 9.5',Water Valve+49.9, 44.3',Sign (Stop)+67.8, 11.7',Mailbox+61.8, 25.7',PP w/Riser+61.7, 28.9',60" Bush+59.5, 42.7',Guy Wire+59.7, 43.8',Guy Wire+70.4, 45.0',15" Con.+03.9, 41.0',Water Meter+28.9, 33.1',3" Dec.+40.2, 43.7',24" Dec.+67.5, 12.9',Gas Marker+66.5, 13.5',Power Pole+69.5, 19.6',Guy Wire+69.6, 23.2',Guy Wire+66.1, 31.0',60" Bush+43.5, 20.9',24" Bush+42.7, 40.9',Yard Light+39.7, 21.3',24" Bush+34.7, 13.9',Sign (W11A-2)+34.9, 21.3',24" Bush+30.3, 21.2',36" Bush+25.4, 21.2',36" Bush+19.0, 12.0',Mailbox+20.3, 21.2',24" Bush+15.5, 21.1',24" Bush+10.6, 21.5',24" Bush+22.4, 49.4',6" Dec.+11.3, 48.0',30" Dec.+05.4, 20.7',24" Bush+00.5, 20.9',24" Bush+94.6, 20.9',24" Bush+89.2, 20.5',24" Bush+83.1, 20.8',24" Bush+78.0, 11.7',Gas Marker+76.4, 21.2',24" Bush+83.9, 41.9',36" Dec.+69.5, 39.4',Power Pole+63.2, 20.0',24" Bush+66.3, 19.5',24" Bush+69.1, 17.5',24" Bush+73.4, 19.3',24" Bush+77.8, 21.5',24" Bush+80.4, 23.2',24" Bush+85.1, 27.2',24" Bush+87.0, 28.5',12" Bush+88.4, 30.7',24" Bush+89.2, 36.3',24" Bush+73.2, 39.4',48" Dec.+01.1, 29.2',Water Valve+98.2, 32.1',Water Valve+96.4, 37.6',Water Valve+90.1, 46.1',24" Bush+90.2, 49.7',24" Bush+33.5, 42.0',Sign (Stop)+36.4, 43.4',Gas Vavle+37.9, 30.3',San. M.H.+46.6, 28.3',Power Pole+62.9, 43.9',30" Dec.+62.9, 43.9',30" Dec.+12.2, 22.4',Mailbox+10.7, 46.1',30" Bush+22.1, 42.4',Water Meter+62.2, 39.8',Guy Wire+63.8, 43.3',96" Bush+73.2, 40.4',PP w/Riser+73.4, 48.5',Guy WireN0°06'57"E 12" P i p e 18" Pipe(asph. path)12" Pipe12" Pipe 12" Pipe 12" Pipe GRAND BLVD.36" Pipe36" Pipe36" Pipe 24" Pipe 12" Pipe2 4 " P i p e12" Pipe24" Pipe 10" Pip e 12" San.12" San.12" San.12" San.24" San.12" San.12" San. App. Exist. R/W App. Exist. R/WApp. Exist. R/WApp. Exist. R/W(conc. walk)(conc. walk) App. Exist. R/W App PLApp PLApp PLApp. Exist. R/WApp. Exist. R/WApp. Exist. R/WApp. Exist. R/WApp PLApp PLApp PLConstr. Limits Constr. Limits Constr. Limits Constr. Limits Temp R/W for Drive Const. Temp R/W for Drive Const. App. Exist. R/W App. Exist. R/W +38 "B" PL(41') +33 "B" 51' +33 "B" 81'+78 "B" 81' +77.82 "B" 51' +73 "B" PL(41') +81 "B" PL(39') +PL(+21.99 )"B" 81' +81 "B" 81' Str. No. 41 Str. No. 40 Str. No. 34 Str. No. 39 Str. No. 33Str. No. 38 Str. No. 45 Str. No. 32 Str. No. 37 Str. No. 42 Str. No. 44 Str. No. 29A Str. No. 30 Str. No. 29 Str. No. 30A Str. No. 28 12" San . Proposed Grade 26+00 27+00 28+00 29+00 30+00 31+00 32+00 33+00840.34840.25840.15840.25840.38840.39840.58840.84841.14841.56841.92842.21842.32842.33842.36842.35842.37842.42842.52842.66842.84843.03843.20843.32843.32843.14842.67842.19841.59840.76840.01839.32840.29840.18840.15840.19840.31840.47840.64840.80840.96841.12841.29841.45841.61841.77841.94842.10842.26842.42842.59842.75842.91843.07843.23843.30843.23843.01842.65842.16841.52840.80840.14839.54PVI STA: 32+25.73 PVI ELEV: 843.73 VCL: 160.00 PVI STA: 25+76.32 PVI ELEV: 839.51 VCL: 250.00 840.29840.18840.15840.19840.31840.47840.64840.80840.96841.12841.29841.45841.61841.77841.94842.10842.26842.42842.59842.75842.91843.07843.23843.30843.23843.01842.65842.16841.52840.80840.14839.54 PIPE @ 0.30%24"∅ PIPE @ 0.30%24"∅ PIPE @ 0.30% 24"∅ PIPE @ 0.30%INV. = 835.20 INV. = 834.73 INV. = 834.20 INV. = 833.21INV. = 834.20 INV. = 835.20 INV. = 834.73 21"∅ PIPE @ 0.30% Str. No. 38 Str. No. 41 Str. No. 45 24"∅ PIPE @ 0.30% Str. No. 31 Std. Ditch Rt. (In Utility Strip) 1.5' Deep. Std. Ditch Rt. (In Utility Strip) 1.53' Deep. +75 840.78 -2.97%+0.65% All R/W and Topo from Line "B" Unless Noted Otherwise PROPOSED (See Typical Sheet for Additional Details) Concrete Curb (Barrier)14 Mill and OverlayR 15 Sodding26 16 LEGEND EXISTING Storm Manhole Gas Line Storm Inlets Sanitary Manhole Gas Valve Gas Meter Sanitary Cleanout Water Line Water Valve Fire Hydrant Sprinkler Electric Line Power Pole w/(Riser) Light & Power Pole Light & Power Pole w/Riser Water Meter Light Pole Guy Wire Electric Box Fiber Optic Line Telephone Line Telephone Manhole Cable TV Line Cable TV Box Telephone Riser Utility Manhole Wood Fence Iron Pin Sign Flag Pole Bush Tree Trunk Deciduous Tree Coniferous Tree Overhead Utility Line Wood Fence Wire Fence Chainlink Fence Iron Fence Irr. Valve Mailbox Concrete Sidewalk, 4"F 18 Concrete Center Curb, Type 'D'19 Combined Concrete Curb & Gutter (Barrier) Modified Roll Curb Combined Concrete Curb & Gutter (Barrier) (Dry) Concrete Curb Ramp C2 PCCP, 7" with D-1 Contraction Joints Spaced at 14' Max. HMA for SidewalkP Asphalt ShoulderJ C PCCP, For Approaches 6" on Subgrade Treatment Type II. H C1 PCCP, For Approaches 9" on Subgrade Treatment Type II. Retaining WallW Full Depth Asphalt PavementK1 Removal (Pvmt, Sidewalk, Concrete) D HMA For Approaches (See Typical Sheet for Additional Details) TBM #474 - Cut " " on SW Corner of Square Concrete Light Pole Foundation in Parking Lot at SE Corner of 852 W. Main St. Sta. 5+10.70 "S-1-B", 93.46' Lt., Elev. = 847.88' TBM #471 - Cut "X" on WNW Bonnet Bolt of Fire Hydrant. Sta. 39+12.52 "B", 26.67' Rt., Elev. = 836.47' TBM #472 - RR Spike set 1.0' up on W. face of Power Pole #185-562. Sta. 30+66.56 "B", 12.53' Rt., Elev. = 842.79' TBM #473 - Cut "X" on N Bonnet Bolt of Fire Hydrant. Sta. 22+78.42 "B", 42.79' Lt., Elev. = 844.99 TBM #478 -Cut "X" on NNE Bonnet Bolt of Fire Hydrant. Sta. 11+66.72 "B", 62.69' Rt., Elev. = 845.12' TBM #470 - Top of NW Corner of Bottom Porch Step Sta. 47+35.12 "B", 88.05' Rt., Elev. = 852.06' ORIGINATING BENCHMARK DESIGNATION - V 42 PID - LB0600 STATE/COUNTY - IN/HAMILTON USGS QUAD - WESTFIELD (1992) VERT ORDER - SECOND CLASS 0 DESCRIBED BY COAST AND GEODETIC SURVEY 1934 1.8 MILES SOUTH ALONG THE CHICAGO, INDIANAPOLIS AND LOUISVILLE RAILWAY FROM THE STATION AT WESTFIELD, HAMILTON COUNTY, 6 1 2 RAILS SOUTH OF CULVERT B-165.1 IN THE NORTHEAST ANGLE OF A GRAVEL ROAD, 9 YARDS EAST OF THE EAST RAIL, 6 YARDS NORTH OF THE CENTERLINE OF THE ROAD, AND ABOUT 3 FEET HIGHER THAN THE RAIL. A STANDARD DISK, STAMPED V 42 1934 AND SET IN THE TOP OF A CONCRETE POST PROJECTING ONE-HALF FOOT ABOVE GROUND. ELEVATION = 884.62 (NAVD 88) (A) CUT "X" ON EAST EDGE OF RIM OF MH, 34.65' (B) MAG NAIL SET ON NORTH SIDE OF PP #186034 UP 1.0', 49.95' (C) CUT NOTCH ON W SIDE OF PED CROSSING PIC POST UP 1.0', 38.37' (D) T.B.M. 411, SET RR SPIKE ON W SIDE OF PP# 185562 UP 1.0', 60.27' N = 48483.4849 E = 60686.5859 CONTROL POINT 172 (MAG NAIL) - O.P.O.T. STA. 31+17.00', -20.39' (L) LINE "B" (A) MAG W/ WASHER FOUND ON W SIDE OF PP# 300184 UP 1.0', 99.79' (B) MAG W/ WASHER FOUND ON W SIDE OF PP# 300185 UP 1.0', 74.02' (C) MAG W/ WASHER FOUND ON E SIDE OF PP# 300186 UP 1.0', 91.20' (D) CENTER OF WATER VALVE, 48.50' (E) CENTER OF GAS VALVE, 60.60' (F) T.B.M. 473, CUT "X" ON NORTH BONNET BOLT OF HYD, 104.15' CONTROL POINT 173 (PIN WITH CAP) - O.P.O.T. STA. 21+91.78', 14.97' (R) LINE "B" N = 47558.1910 E = 60720.0750 (B) ON BC WHERE CONCRETE SIDEWALK EDGE MEETS CURB, 6.00' C.P. 172 (A) (B) (C)(D) GUILFORD RD. LINE "B" COLLEGE CARMEL MIDDLE SCHOOL WAY C.P. 173 (A)(B) (C) (D) GUILFORD RD. LINE "B"126th ST.(E)(F) WATERLILY WAY (A) MAG NAIL ON NW SIDE OF CONCRETE BASE OF TRAFFIC POLE, 13.34'LINE "B" A.J.W. RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALEINDIANA DEPARTMENT OF TRANSPORTATION M.B. A.P. M.B. 4/2/2018 VERTICAL SCALE 1383180 1383180 R-36906 76ERR 1 S EF SPRONO. ASTATE OF D NIO IN LA AI N 01306 NGINE 27 EERIGEETS DANDREW J OHN W OLFDIRECTORY PATH: R:\Active\Carmel\Guilford Road Des. No. 1383180\CAD\PlansFILENAME: PP-B.dwgDATE/USER: 7/20/2018 4:25 PM / AwolfPLAN AND PROFILE LINE "B" 1"=30' 1"=5' 835 830 825 840 MATCH LINE 33+75 "B"845 850 855 15 835 830 825 840 845 850 855MATCH LINE 26+00 "B" 34+0035+0036+0037+0038+0039+0040+0041+00FRANK ANTHONY & KAREN S. RUTKKOWSKI RYAN D. MCHOME CARRIE E. STOCK DAVID M. & ANGELA E. CONCANNON PAUL J. MILLER S. GUILFORD ROAD Line "B" CARMEL 2002 SCHOOLS BUILDING CORPORATION (concrete sl o p e w a l l )EMERSON RD.App. Exist. R/W App. Exist. R/W App. Exist. R/W Sec. 25, T18N, R3E Clay Township Hamilton County Sec. 25, T18N, R3E Clay Township Hamilton County (conc. walk) (asph. path) (grass) (grass) (lawn) (lawn)(lawn) (asph. path)+45,10'(asph)+16,30'(asph)+24,19'(asph)+82,24'(asph)(grass) (grass)+10,17'(asph)(grass)+68,35'(asph)+63,30'(asph)(conc. walk)(conc. walk) (conc. walk) (conc. walk) (grass)(conc. walk)(asph. p a t h ) (grass) T.B.M. 471 C.P. 171+03.3, 44.3', 6" Dec.+37.1, 43.8', 6" Dec.+63.0, 23.3', Inlet+70.3, 44.6', 6" Dec.+49.5, 39.7', Rnd. Inlet+67.1, 41.9', Sign (Stop)+59.0, 48.0', Tele Box+68.6, 41.7', 24" Dec.+95.4, 43.0', 6" Dec.+18.5, 42.0', 6" Dec.+43.7, 42.1', 6" Dec.+93.7, 41.5', 18" Dec.+15.7, 22.9', Inlet+20.6, 21.7', San. M.H.+45.9, 23.3', Inlet+19.8, 41.8',Water Meter+30.3, 24.6',Mailbox+62.4, 23.7',Water Valve+62.4, 25.3',Fire Hyd.+74.3, 23.3',Mailbox+08.8, 41.4',Water Meter+16.5, 170.1',12" Con.+51.4, 39.4',PP w/Riser+98.9, 41.2',Water Meter+06.7, 24.2',Mailbox+37.6, 29.8',San. M.H.+43.9, 25.3',Sign (25 MPH)+56.4, 45.3',24" Dec.+86.5, 41.2',Water Meter+91.2, 45.3',18" Dec.+95.9, 24.0',Mailbox+39.3, 38.9',Power Pole+73.2, 49.0',Water Meter+15.8, 24.6',Sign (W11A-2)+30.5, 48.1',9" Con.+48.4, 24.7',Water Valve+79.9, 32.6',Inlet+79.1, 43.6',Sign (Stop)+83.1, 39.5',PP w/Light+12.4, 27.2',Fire Hyd.+50.0, 23.9',Water Valve+70.9, 25.3',3" Dec.+26.2, 38.5',Power Pole+76.8, 26.1',6" Dec.+68.2, 40.7',9" Con.+58.7, 48.8',6" Con.+00.4, 23.8',Water Valve+06.4, 26.1',1" Dec.+37.4, 23.1',Sign (30 MPH)+44.7, 42.7',9" Con.+09.0, 42.8',6" Con.+47.4, 32.3',Inlet+34.8, 37.7',PP w/RiserN0°06'57"E10" Pip e 24" Pipe 1 8 " P i p e 15" Pipe15" Pipe 12" Pi p e 24" Pipe 24" Pipe 12" Pipe 24" Pipe 24" Pipe12" Pipe? ? " P ip e 24" Pipe 24" Pip e 24" P i p e 24" P i p e 24" Pipe 24" Pipe 12" Pipe108" CMP12" Pipe (Conc. P.S.D.) 15" Pipe 15" Pipe 12" Pipe12" Pipe (conc. walk)CARMEL CLAY SCHOOLS +16.2, 52.0', Rnd. Inlet+60.6, 52.3', F/O Box+98.1, 53.4', 6" Dec.+44.8, 71.6', Inlet+46.2, 55.2', Storm M.H.+17.7, 71.4', Inlet+91.9, 71.4', Inlet+93.1, 57.5', Storm M.H.+19.1, 54.2', Elec. Box+38.3, 52.9', Sign (Stop)+39.0, 59.2', Light Pole+53.1, 80.9', Inlet+16.4, 103.9', Rnd. Inlet+28.8, 36.8', Storm M.H.+49.9, 32.9', San. M.H.+58.1, 39.5', Rnd. Inlet+79.8, 71.3', Inlet+87.1, 51.1', 30" Dec.+21.9, 55.5',San. M.H.+32.2, 40.1',Pipe End Sect.+32.2, 55.5',San. M.H.+29.6, 60.7',San. M.H.+35.4, 28.6',Pipe End Sect.+19.2, 63.1',San. M.H.12" San. 12" San.8" San.8" San.12" San. 12" San. WILSON VILLAGE CONDOMINIUMSApp PLApp PLApp. Exist. R/W App PLApp PLApp PLConstr. Limits (conc.)App. Ex ist. R/W Constr. Limits Constr. Limits Constr. Limits R/W R/WR/WR/WR/W Temp R/W for Drive Const. Temp R/W for Drive Const. Temp R/W for Drive Const. Temp R/W for Drive Const. Temp R/W for Drive Const. R/W R/W App. Exist. R/W App. Exist. R/WApp. Exist. R/W Constr. Limits +60 "B" PL(40') +60 "B" 75' +04 "B" 75' +04 "B" 46' +11 "B" PL(40') +11 "B" 45' +36 "B" PL(50') +36 "B" 91' +02 "B" 91' +02 "B" PL(50') +81 "B" 50'+81 "B" PL(40') +85 "B" PL(50') +85 "B" 62'+29 "B" 62' +29 "B" PL(50') +26 "B" PL(40') +26 "B" 93' +58 "B" 93' +81 "B" 57' +03 "B" PL(40') +13 "B" 68' +30 "B" PL(40') +21.50 "B" PL(40') +21.56 "B" 53' +97.96 "B" 53' +98 "B" PL(40') +35.82 "B" PL(40') +35.82 "B" 57' +12.22 "B" 57' +12.32 "B" PL(40')+98.73 "B" PL(40') +98.79 "B" 53' +75.19 "B" 53' +75.23 "B" PL(40') +50.89 "B" PL(40') +50.94 "B" 50' +37.04 "B" 50' +37.06 "B" PL(40') Temp R/W for Clearing and Grading +03 "B" 74' +72 "B" 81' +61.83 "B" 87' Str. No. 47B Str. No. 48 Str. No. 47 Str. No. 46 Str. No. 54 Str. No. 61 Str. No. 66 Str. No. 50 Str. No. 53 Str. No. 49 Str. No. 58 Str. No. 55 Str. No. 57 Str. No. 67 Str. No. 65 Str. No. 62 Str. No. 62A Str. No. 60A Str. No. 60 Str. No. 64 Str. No. 51 Str. No. 56 Str. No. 52 Str. No. 63 Str. No. 47A Str. No. 56A Proposed Grade Exist. Grade @ Line "B" 34+00 35+00 36+00 37+00 38+00 39+00 40+00 41+00839.32838.62838.15837.77837.53837.34837.24837.16837.11837.05837.00836.94836.84836.75836.66836.58836.50836.44836.38836.29836.19836.11836.01835.98836.05836.06836.07836.25836.50836.90837.30837.88839.54839.02838.56838.16837.83837.57837.37837.24837.16837.07836.99836.91836.83836.74836.66836.58836.50836.41836.33836.25836.17836.08836.04836.05836.12836.24836.42836.65836.93837.27837.66838.11PVI STA: 34+30.87 PVI ELEV: 837.63 VCL: 250.00 PVI STA: 40+69.50 PVI ELEV: 835.52 VCL: 350.00 839.54839.02838.56838.16837.83837.57837.37837.24837.16837.07836.99836.91836.83836.74836.66836.58836.50836.41836.33836.25836.17836.08836.04836.05836.12836.24836.42836.65836.93837.27837.66838.1127"∅ PIPE @ 0.30%27"∅ PIPE @ 0.30%27"∅ PIPE @ 0.30%18"∅ PIPE @ 0.30% INV. = 832.27 INV. = 831.80 INV. = 831.38 INV. = 832.80 INV. = 832.27 INV. = 831.80 18"∅ PIPE @ 0.30% 24"∅ PIPE @ 0.30% Str. No. 48 Str. No. 54 Str. No. 58 Str. No. 61 Str. No. 66 Std. Ditch Rt. (In Utility Strip) 2.3' Deep. Std. Ditch Rt. (In Utility Strip) 2.3' Deep. +70 835.98 +50 834.37 -2.0% Std. Ditch Rt. (In Utility Strip) 1.53' Deep. Str. No. 47B +90.69 837.84 -0.33% All R/W and Topo from Line "B" Unless Noted Otherwise PROPOSED (See Typical Sheet for Additional Details) Concrete Curb (Barrier)14 Mill and OverlayR 15 Sodding26 16 LEGEND EXISTING Storm Manhole Gas Line Storm Inlets Sanitary Manhole Gas Valve Gas Meter Sanitary Cleanout Water Line Water Valve Fire Hydrant Sprinkler Electric Line Power Pole w/(Riser) Light & Power Pole Light & Power Pole w/Riser Water Meter Light Pole Guy Wire Electric Box Fiber Optic Line Telephone Line Telephone Manhole Cable TV Line Cable TV Box Telephone Riser Utility Manhole Wood Fence Iron Pin Sign Flag Pole Bush Tree Trunk Deciduous Tree Coniferous Tree Overhead Utility Line Wood Fence Wire Fence Chainlink Fence Iron Fence Irr. Valve Mailbox Concrete Sidewalk, 4"F 18 Concrete Center Curb, Type 'D'19 Combined Concrete Curb & Gutter (Barrier) Modified Roll Curb Combined Concrete Curb & Gutter (Barrier) (Dry) Concrete Curb Ramp C2 PCCP, 7" with D-1 Contraction Joints Spaced at 14' Max. HMA for SidewalkP Asphalt ShoulderJ C PCCP, For Approaches 6" on Subgrade Treatment Type II. H C1 PCCP, For Approaches 9" on Subgrade Treatment Type II. Retaining WallW Full Depth Asphalt PavementK1 Removal (Pvmt, Sidewalk, Concrete) D HMA For Approaches (See Typical Sheet for Additional Details) TBM #474 - Cut " " on SW Corner of Square Concrete Light Pole Foundation in Parking Lot at SE Corner of 852 W. Main St. Sta. 5+10.70 "S-1-B", 93.46' Lt., Elev. = 847.88' TBM #471 - Cut "X" on WNW Bonnet Bolt of Fire Hydrant. Sta. 39+12.52 "B", 26.67' Rt., Elev. = 836.47' TBM #472 - RR Spike set 1.0' up on W. face of Power Pole #185-562. Sta. 30+66.56 "B", 12.53' Rt., Elev. = 842.79' TBM #473 - Cut "X" on N Bonnet Bolt of Fire Hydrant. Sta. 22+78.42 "B", 42.79' Lt., Elev. = 844.99 TBM #478 -Cut "X" on NNE Bonnet Bolt of Fire Hydrant. Sta. 11+66.72 "B", 62.69' Rt., Elev. = 845.12' TBM #470 - Top of NW Corner of Bottom Porch Step Sta. 47+35.12 "B", 88.05' Rt., Elev. = 852.06' ORIGINATING BENCHMARK DESIGNATION - V 42 PID - LB0600 STATE/COUNTY - IN/HAMILTON USGS QUAD - WESTFIELD (1992) VERT ORDER - SECOND CLASS 0 DESCRIBED BY COAST AND GEODETIC SURVEY 1934 1.8 MILES SOUTH ALONG THE CHICAGO, INDIANAPOLIS AND LOUISVILLE RAILWAY FROM THE STATION AT WESTFIELD, HAMILTON COUNTY, 6 1 2 RAILS SOUTH OF CULVERT B-165.1 IN THE NORTHEAST ANGLE OF A GRAVEL ROAD, 9 YARDS EAST OF THE EAST RAIL, 6 YARDS NORTH OF THE CENTERLINE OF THE ROAD, AND ABOUT 3 FEET HIGHER THAN THE RAIL. A STANDARD DISK, STAMPED V 42 1934 AND SET IN THE TOP OF A CONCRETE POST PROJECTING ONE-HALF FOOT ABOVE GROUND. ELEVATION = 884.62 (NAVD 88) (A) CUT "X" ON EAST EDGE OF RIM OF MH, 34.65' (B) MAG NAIL SET ON NORTH SIDE OF PP #186034 UP 1.0', 49.95' (C) CUT NOTCH ON W SIDE OF PED CROSSING PIC POST UP 1.0', 38.37' (D) T.B.M. 411, SET RR SPIKE ON W SIDE OF PP# 185562 UP 1.0', 60.27' N = 48483.4849 E = 60686.5859 CONTROL POINT 172 (MAG NAIL) - O.P.O.T. STA. 31+17.00', -20.39' (L) LINE "B" (A) MAG W/ WASHER FOUND ON W SIDE OF PP# 300184 UP 1.0', 99.79' (B) MAG W/ WASHER FOUND ON W SIDE OF PP# 300185 UP 1.0', 74.02' (A) MAG NAIL ON W SIDE OF POWER POLE #300216 UP 1.0', 64.66' (B) CENTER OF WATER VALVE, 60.50' (C) CUT "X" ON EAST EDGE OF NORTH SAN MH, 51.77' (D) T.B.M. 400, CUT "X" ON NNW BONNET BOLT OF HYD, 99.98' N = 49366.6736 E = 60687.5396 CONTROL POINT 171 (MAG NAIL) - O.P.O.T. STA. 40+00.19', -21.22' (L) LINE "B" C.P. 171 (A) (B) (C) (D) GUILFORD RD. LINE "B"EMERSONCARMEL MIDDLE SCHOOL C.P. 172 (A) (B) (C)(D) GUILFORD RD. LINE "B" COLLEGE CARMEL MIDDLE SCHOOL WAY (A) MAG NAIL ON NW SIDE OF CONCRETE BASE OF TRAFFIC POLE, 13.34' A.J.W. RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALEINDIANA DEPARTMENT OF TRANSPORTATION M.B. A.P. M.B. 4/2/2018 VERTICAL SCALE 1383180 1383180 R-36906 76ERR 1 S EF SPRONO. ASTATE OF D NIO IN LA AI N 01306 NGINE 27 EERIGEETS DANDREW J OHN W OLFDIRECTORY PATH: R:\Active\Carmel\Guilford Road Des. No. 1383180\CAD\PlansFILENAME: PP-B.dwgDATE/USER: 7/20/2018 4:25 PM / AwolfPLAN AND PROFILE LINE "B" 1"=30' 1"=5' 835 830 825 840 MATCH LINE 41+50 "B"845 850 855 16 835 830 825 840 845 850 855MATCH LINE 33+75 "B" 42+0043+0044+0045+0046+0047+0048+0049+00SHOTZIE LLCAUBREY S. & JANIE D. NARAINE MAIN & GUILFORD PLAZA LLC MIG GUILFORD RESERVE LLC S. GUILFORD ROAD Line "B"DRUID HILL DR.WILSON TERRACE CT.W. MAIN ST.CARMEL CLAY SCHOOLS MATT D. MITCHEL App. Exist. R/W App. Exist. R/W Sec. 25, T18N, R3E Clay Township Hamilton County Sec. 25, T18N, R3E Clay Township Hamilton County+22,33(asph)(conc. walk) (grass) (grass) (conc. walk) (grass) (grass) (grass) (bushes) (grass)+96,22'(asph)+42,16'(asph)+14,24'(asph)(conc. walk)(conc. walk) (conc. walk) (conc. walk) (grass) (grass) ALTA JANE ROTHFUSS TRUSTEE OF ALTA JANE ROTHFUSS REV TRUST Line "S-1-B"C.P. 170T.B.M. 471 N0°06'57"E N1°29'20"EN88°49'50"EN88°57'59"E15" Pipe (bushes)(bushes)GUILFORD TRAIL DR.(conc. walk ) P.I. STA: 48+20.44 (No Curve) (Face of Exist. Bldg.)(conc. walk)(grass)(conc. walk)+50.3, 39.1', RR Spike SetT+75.3, 48.1', 36" Dec.+98.3, 19.6', Sign (25 MPH) begin school zone+00.6, 35.4', Guy Wire+00.5, 37.6', Guy Wire+12.0, 37.9', 6" Dec.+99.0, 23.2', Flashing Sig. Pole, School Zone 25 mph+00.1, 50.7', Power Pole+39.5, 22.6', 3" Dec.+66.7, 23.3', 3" Dec.+77.0, 28.9', San. M.H.+93.3, 23.7', 3" Dec.+05.5, 25.8', Sign+21.4, 23.5', 3" Dec.+58.3, 27.6', Rock+74.4, 52.0', Water Valve+77.6, 55.0', Water Valve+81.5, 57.0', Water Valve+93.0, 28.0', San. M.H.+57.5, 24.8', Middle of Sign in Mulch+89.4, 39.6', 36" Bush+93.8, 27.9', 3" Dec.+95.8, 39.6', PP w/Riser+46.0, 28.3', 3" Dec.+70.5, 28.0', 3" Dec.+90.0, 28.3', 3" Dec.+05.1, 28.5', 3" Dec.+19.7, 30.6', 3" Dec.+31.9, 40.8', Cor. Bldg.+37.2, 42.3', Cor. Bldg.+57.7, 63.7', Cor. Bldg.+47.2, 8.0', Detector+47.9, 30.8', Rnd. Inlet+61.3, 32.1', Signal Pole+66.6, 26.3', Traf. M.H.+74.1, 36.5', 3" Dec.(mulch/shrubs)+77.8, 78.1', Water Valve+91.4, 78.2', Rnd. Inlet+82.1, 93.5', 3" Dec.+99.6, 20.8', Water Valve+00.3, 27.8', Water Valve+52.1, 41.1', Signal Pole+60.8, 11.1', Detector+65.4, 57.6', Irr. Valve+67.1, 40.7', PP w/Riser+74.3, 49.5', Sign+81.9, 44.2', 72" Bush+88.0, 41.8', 72" Bush+13.4, 41.1', 12" Dec.+99.1, 41.8', 3" Dec.+82.9, 47.1', 2 Guy Wires+06.3, 70.9', Light Pole(shrubs/mulch)+87.5, 62.7', Pipe End Sect.+53.0, 57.5',6" Dec.+60.3, 43.4',Sprinkler Head+60.5, 44.6',Sprinkler Head+67.9, 45.8',48" Bush+71.4, 24.5',Water Meter+71.6, 40.4',Sprinkler Head+93.5, 43.8',24" Dec.+29.5, 45.6',24" Dec.+35.2, 45.3',3" Con.+41.2, 45.6',3" Con.+48.0, 45.5',3" Con.+51.3, 46.5',3" Con.+65.9, 42.1',6" Con.+77.1, 44.4',9" Con.+69.9, 38.1',Tele Box+86.3, 37.8',PP w/Light+93.6, 36.2',Mag Nail Fnd+97.1, 58.9',9" Dec.+48.4, 26.5',Street Sign+71.5, 15.9',Sign, End Sch. Zn.+48.0, 51.1',Sign in Mulch w/shrubs+94.7, 41.8',Tele Box+77.8, 31.0',San. M.H.+27.8, 48.9',Irr. Valve+31.0, 54.0',30" Dec.+94.5, 54.6',30" Dec.+58.3, 41.4',9" Con.+70.9, 42.1',9" Con.+95.9, 40.7',9" Con.+66.2, 24.7',Water Valve+80.2, 22.2',Water Valve+83.4, 38.3',PP w/Riser+25.1, 38.0',PP w/Riser+40.7, 30.2',San. M.H.+50.1, 41.4',9" Con.+67.1, 51.2',48" Bush+77.9, 24.5',Water Valve+76.0, 50.5',Sign (No Outlet)+83.4, 47.4',Gas Vavle+95.0, 34.1',Mag Nail Fnd+15.7, 52.0',Sign in Mulch/Shrubs+25.2, 28.9',RR Spike SetT+30.9, 37.5',PP w/Light+33.0, 49.6',Sq. Inlet+66.2, 26.3',Fire Hyd.+54.1, 42.1',3" Dec.+52.9, 50.0',24" Bush+54.3, 47.3',24" Bush+54.4, 52.6',24" Bush+61.0, 47.2',12" Dec.+61.7, 51.8',18" Dec.+90.1, 37.9',Sprinkler Head+91.5, 55.3',24" Dec.+11.0, 54.8',24" Dec.+99.5, 39.9',Water Meter+20.5, 39.0',PP w/Riser+30.7, 17.4',Water Valve+39.4, 38.2',Guy Wire+44.5, 38.0',Guy Wire+46.3, 38.0',Guy Wire+49.7, 38.6',Guy Wire+49.7, 40.0',Sprinkler Head+77.3, 35.6',Tele M.H.+72.8, 10.7',Detector+89.9, 30.9',Gas Marker+98.6, 25.5',Water Valve+86.5, 30.8',San. M.H.+01.4, 47.8',Signal Pole+56.7, 44.6',Power Pole+60.7, 35.2',Signal Pole+17.7, 43.7',9" Dec.12" Pipe12" Pipe12" Pipe12" Pipe(bldg.) (Face of Exist. Bldg.)1+002+00 Line "C" 12" San.8" San.12" San. 8" San.8" San.8" San.12" San.12" San.12" San.6" San.6"WILSON VILLAGE CONDOMINIUMS WILSON VILLAGE CONDOMINIUMS GUILFORD TRAIL TOWNHOMESApp PLApp PLApp. Exist. R/W App. Exist. R/WApp. Exist. R/WApp. Exist. R/WApp. Exist. R/WApp. Exist. R/WApp. Exist. R/WApp PL Constr. Limits Constr. Limits Constr. Limits Constr. Limits Constr. Limits +40.0, 36.1',Traf. M.H.R/W R/W R/W R/ W R/W R /W Temp R/W for Drive Const. Temp R/W for Drive Const. Temp R/W for Drive Const. App. Exist. R/W +PL(+19.47 )"B" 50' +70 "B" 75' +20 "B" 75' +20 "B" PL(40') +70 "B" PL(40') +PL(+19 )"S-1-B" 50' +08 "B" PL(40') +02 "B" 49' +88 "S-1-B" 40' +PL(+12 )"S-1-B" 30' +99 "B" PL(40') +99 "B" 75'+53 "B" 75' +53 "B" PL(40') +29.97 "B" PL(40') +30 "B" 53' +54 "B" 50' +54 "B" PL(40') +54 "B" 53' +12 "B" 50' +43 "B" 60' +12 "S-1-B" PL(42') +12 "S-1-B" 49' Do Not Disturb Sign Str. No. 77 Str. No. 78 Str. No. 82 Str. No. 80 Str. No. 81 Str. No. 83 Str. No. 71 Str. No. 73 Str. No. 72Str. No. 68 Str. No. 70 Str. No. 69 Str. No. 75 Str. No. 76 SEE THE PROFILES AND SPOT ELEVATION SHEETS FOR ROUNDABOUT GRADES Proposed Grade Exist. Grade @ Line "B" 42+00 43+00 44+00 45+00 46+00 47+00 48+00 49+00837.88838.46839.12839.80840.45841.09841.70842.33843.01843.68844.36845.04846.02846.93847.57848.21848.87849.53850.13850.50850.74850.82850.81850.72850.63850.68850.63850.58850.35850.24850.16850.19838.11838.62839.18839.79840.46841.14841.82842.50843.19843.87844.55845.24845.92846.60847.29847.97848.65849.22849.65849.95850.12PVI STA: 46+04.79 PVI ELEV: 850.15 VCL: 125.00 838.11838.62839.18839.79840.46841.14841.82842.50843.19843.87844.55845.24845.92846.60847.29847.97848.65849.22849.65849.95850.1212"∅ PIPE @ 0.50% 12"∅ PIPE @ 2.05% INV. = 845.18 INV. = 836.16 INV. = 831.97 INV. = 840.06 18"∅ PIPE @ 0.30% Str. No. 68 Str. No. 71 Str. No. 77 12"∅ PIPE @ 2.25% Str. No. 75 Std. Ditch Rt. (In Utility Strip) 2.3' Deep.+61.21 838.49 +2.73% +0.00% All R/W and Topo from Line "B" Unless Noted Otherwise PROPOSED (See Typical Sheet for Additional Details) Concrete Curb (Barrier)14 Mill and OverlayR 15 Sodding26 16 LEGEND EXISTING Storm Manhole Gas Line Storm Inlets Sanitary Manhole Gas Valve Gas Meter Sanitary Cleanout Water Line Water Valve Fire Hydrant Sprinkler Electric Line Power Pole w/(Riser) Light & Power Pole Light & Power Pole w/Riser Water Meter Light Pole Guy Wire Electric Box Fiber Optic Line Telephone Line Telephone Manhole Cable TV Line Cable TV Box Telephone Riser Utility Manhole Wood Fence Iron Pin Sign Flag Pole Bush Tree Trunk Deciduous Tree Coniferous Tree Overhead Utility Line Wood Fence Wire Fence Chainlink Fence Iron Fence Irr. Valve Mailbox Concrete Sidewalk, 4"F 18 Concrete Center Curb, Type 'D'19 Combined Concrete Curb & Gutter (Barrier) Modified Roll Curb Combined Concrete Curb & Gutter (Barrier) (Dry) Concrete Curb Ramp C2 PCCP, 7" with D-1 Contraction Joints Spaced at 14' Max. HMA for SidewalkP Asphalt ShoulderJ C PCCP, For Approaches 6" on Subgrade Treatment Type II. H C1 PCCP, For Approaches 9" on Subgrade Treatment Type II. Retaining WallW Full Depth Asphalt PavementK1 Removal (Pvmt, Sidewalk, Concrete) D HMA For Approaches (See Typical Sheet for Additional Details) TBM #474 - Cut " " on SW Corner of Square Concrete Light Pole Foundation in Parking Lot at SE Corner of 852 W. Main St. Sta. 5+10.70 "S-1-B", 93.46' Lt., Elev. = 847.88' TBM #471 - Cut "X" on WNW Bonnet Bolt of Fire Hydrant. Sta. 39+12.52 "B", 26.67' Rt., Elev. = 836.47' TBM #472 - RR Spike set 1.0' up on W. face of Power Pole #185-562. Sta. 30+66.56 "B", 12.53' Rt., Elev. = 842.79' TBM #473 - Cut "X" on N Bonnet Bolt of Fire Hydrant. Sta. 22+78.42 "B", 42.79' Lt., Elev. = 844.99 TBM #478 -Cut "X" on NNE Bonnet Bolt of Fire Hydrant. Sta. 11+66.72 "B", 62.69' Rt., Elev. = 845.12' TBM #470 - Top of NW Corner of Bottom Porch Step Sta. 47+35.12 "B", 88.05' Rt., Elev. = 852.06' ORIGINATING BENCHMARK DESIGNATION - V 42 PID - LB0600 STATE/COUNTY - IN/HAMILTON USGS QUAD - WESTFIELD (1992) VERT ORDER - SECOND CLASS 0 DESCRIBED BY COAST AND GEODETIC SURVEY 1934 1.8 MILES SOUTH ALONG THE CHICAGO, INDIANAPOLIS AND LOUISVILLE RAILWAY FROM THE STATION AT WESTFIELD, HAMILTON COUNTY, 6 1 2 RAILS SOUTH OF CULVERT B-165.1 IN THE NORTHEAST ANGLE OF A GRAVEL ROAD, 9 YARDS EAST OF THE EAST RAIL, 6 YARDS NORTH OF THE CENTERLINE OF THE ROAD, AND ABOUT 3 FEET HIGHER THAN THE RAIL. A STANDARD DISK, STAMPED V 42 1934 AND SET IN THE TOP OF A CONCRETE POST PROJECTING ONE-HALF FOOT ABOVE GROUND. ELEVATION = 884.62 (NAVD 88) (C) CUT NOTCH ON W SIDE OF PED CROSSING PIC POST UP 1.0', 38.37' (D) T.B.M. 411, SET RR SPIKE ON W SIDE OF PP# 185562 UP 1.0', 60.27' CONTROL POINT 175 (MAG NAIL FLUSH) - O.P.O.T. STA. 50+77.44', -27.22' (L) LINE "B" (A) MAG NAIL SET UP 1.0' ON S FACE PP# 300667, 61.38' (B) CENTER OF GAS VALVE IN WALK, 10.85' (C) MAG NAIL FND UP 1.0' ON E FACE PP# 086533, 33.87' (D) MAG NAIL SET UP 1.0' ON N FACE PP# 300669, 76.66' LINE "B"(A) (B) (C)(D) C.P. 175 N = 50444.4976 E = 60689.8885 (A) MAG NAIL ON W SIDE OF POWER POLE #300216 UP 1.0', 64.66' (B) CENTER OF WATER VALVE, 60.50' (C) CUT "X" ON EAST EDGE OF NORTH SAN MH, 51.77' (D) T.B.M. 400, CUT "X" ON NNW BONNET BOLT OF HYD, 99.98' N = 49366.6736 E = 60687.5396 CONTROL POINT 171 (MAG NAIL) - O.P.O.T. STA. 40+00.19', -21.22' (L) LINE "B" C.P. 171 (A) (B) (C) (D) GUILFORD RD. LINE "B" GUILFORD RD. SHELL EMERSONCARMEL MIDDLE SCHOOL A.J.W. RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALEINDIANA DEPARTMENT OF TRANSPORTATION M.B. A.P. M.B. 4/2/2018 VERTICAL SCALE 1383180 1383180 R-36906 76ERR 1 S EF SPRONO. ASTATE OF D NIO IN LA AI N 01306 NGINE 27 EERIGEETS DANDREW J OHN W OLFDIRECTORY PATH: R:\Active\Carmel\Guilford Road Des. No. 1383180\CAD\PlansFILENAME: PP-B.dwgDATE/USER: 7/20/2018 4:25 PM / AwolfPLAN AND PROFILE LINE "B" 1"=30' 1"=5' 835 830 825 840 MATCH LINE 49+25 "B"845 850 855 17 835 830 825 840 845 850 855MATCH LINE 41+50 "B" 50+0051+0052+0053+0054+0055+00MATT D. MITCHEL N. GUILFORD ROAD Line "B" SHOTZIE LLC +29,18'(conc)+21,32'(asph)+54,19'(asph)+80,16'(asph)(conc. walk) (conc. walk) (grass) (trees/brush) (grass)(grass)(grass) STANLEY A. & ANGELA D. HUNNICUTT MELNICHEK, VLADIMIR & TATIANA FRANK B. DIXON AMERICAN LEGION POST 155 C.P. 175 C.P. 176 N1°29'20"E END PROJECT 50+39.01 "B" (shrubs/mulch)+42.4, 42.8', 3" Dec.+55.4, 40.6', Guy Wire+58.4, 40.8', Guy Wire+68.1, 41.1', PP w/Riser+94.0, 49.8', Monitoring Well+41.5, 34.1', Water Valve+42.7, 50.8', Water Valve+44.2, 50.8', Fire Hyd.+46.3, 41.8', PP w/Riser+58.0, 43.1', Guy Wire+61.9, 43.5', Guy Wire+65.6, 43.3', Guy Wire+74.9, 37.8', Gas Vavle+13.7, 21.7', Guy Wire+19.7, 22.1', Guy Wire+22.8, 22.0', Guy Wire+39.1, 22.3', Power Pole+96.8, 23.2', Power Pole+58.2, 28.1', Power Pole+47.7, 12.0',Mailbox+21.3, 24.7',Power Pole+29.2, 10.9',24" Stump+72.2, 8.9',Mailbox+76.8, 10.0',Gas Vavle+82.8, 33.4',24" Dec.+09.0, 9.6',24" Stump+39.4, 7.7',Sign (35 MPH)+40.9, 8.6',18" Dec.+40.6, 33.3',Water Valve+42.9, 26.7',San. M.H.+62.1, 7.0',Mailbox+64.0, 7.1',Mailbox+03.7, 17.8',12" Dec.+42.0, 17.4',12" Dec.+79.2, 15.6',12" Dec.+97.0, 34.3',12" Dec.+18.1, 15.0',12" Dec.12" Pipe END INCIDENTAL CONSTRUCTION 50+63.54 "B" App. Exist. R/W App. Exist. R/W App PLApp PLApp PLApp PLConstr. Limits Constr. Limits Temp R/W for Drive Const. +PL(+19 )"S-1-B" +64 "B" PL(30') +58.66 "B" PL(32') +60.79 "B" 35' +38.52 "B" 50'+31.58 "B" PL(40') 50+00 51+00 52+00 53+00 54+00 55+00850.27850.35850.40850.44850.59850.80850.95850.97850.99851.03851.15851.27851.35851.32851.12850.90850.60END PROJECT STA. 50+39.01 "A" ELEV. = 850.75 All R/W and Topo from Line "B" Unless Noted Otherwise PROPOSED (See Typical Sheet for Additional Details) Concrete Curb (Barrier)14 Mill and OverlayR 15 Sodding26 16 LEGEND EXISTING Storm Manhole Gas Line Storm Inlets Sanitary Manhole Gas Valve Gas Meter Sanitary Cleanout Water Line Water Valve Fire Hydrant Sprinkler Electric Line Power Pole w/(Riser) Light & Power Pole Light & Power Pole w/Riser Water Meter Light Pole Guy Wire Electric Box Fiber Optic Line Telephone Line Telephone Manhole Cable TV Line Cable TV Box Telephone Riser Utility Manhole Wood Fence Iron Pin Sign Flag Pole Bush Tree Trunk Deciduous Tree Coniferous Tree Overhead Utility Line Wood Fence Wire Fence Chainlink Fence Iron Fence Irr. Valve Mailbox Concrete Sidewalk, 4"F 18 Concrete Center Curb, Type 'D'19 Combined Concrete Curb & Gutter (Barrier) Modified Roll Curb Combined Concrete Curb & Gutter (Barrier) (Dry) Concrete Curb Ramp C2 PCCP, 7" with D-1 Contraction Joints Spaced at 14' Max. HMA for SidewalkP Asphalt ShoulderJ C PCCP, For Approaches 6" on Subgrade Treatment Type II. H C1 PCCP, For Approaches 9" on Subgrade Treatment Type II. Retaining WallW Full Depth Asphalt PavementK1 Removal (Pvmt, Sidewalk, Concrete) D HMA For Approaches (See Typical Sheet for Additional Details) TBM #474 - Cut " " on SW Corner of Square Concrete Light Pole Foundation in Parking Lot at SE Corner of 852 W. Main St. Sta. 5+10.70 "S-1-B", 93.46' Lt., Elev. = 847.88' TBM #471 - Cut "X" on WNW Bonnet Bolt of Fire Hydrant. Sta. 39+12.52 "B", 26.67' Rt., Elev. = 836.47' TBM #472 - RR Spike set 1.0' up on W. face of Power Pole #185-562. Sta. 30+66.56 "B", 12.53' Rt., Elev. = 842.79' TBM #473 - Cut "X" on N Bonnet Bolt of Fire Hydrant. Sta. 22+78.42 "B", 42.79' Lt., Elev. = 844.99 TBM #478 -Cut "X" on NNE Bonnet Bolt of Fire Hydrant. Sta. 11+66.72 "B", 62.69' Rt., Elev. = 845.12' TBM #470 - Top of NW Corner of Bottom Porch Step Sta. 47+35.12 "B", 88.05' Rt., Elev. = 852.06' ORIGINATING BENCHMARK DESIGNATION - V 42 PID - LB0600 STATE/COUNTY - IN/HAMILTON USGS QUAD - WESTFIELD (1992) VERT ORDER - SECOND CLASS 0 DESCRIBED BY COAST AND GEODETIC SURVEY 1934 1.8 MILES SOUTH ALONG THE CHICAGO, INDIANAPOLIS AND LOUISVILLE RAILWAY FROM THE STATION AT WESTFIELD, HAMILTON COUNTY, 6 1 2 RAILS SOUTH OF CULVERT B-165.1 IN THE NORTHEAST ANGLE OF A GRAVEL ROAD, 9 YARDS EAST OF THE EAST RAIL, 6 YARDS NORTH OF THE CENTERLINE OF THE ROAD, AND ABOUT 3 FEET HIGHER THAN THE RAIL. A STANDARD DISK, STAMPED V 42 1934 AND SET IN THE TOP OF A CONCRETE POST PROJECTING ONE-HALF FOOT ABOVE GROUND. ELEVATION = 884.62 (NAVD 88) CONTROL POINT 176 (PIN WITH CAP) - O.P.O.T. STA. 53+43.61', -31.96' (L) LINE "B" (A) MAG NAIL SET UP 1.0' ON WEST FACE OF PP# 086951, 14.85' (B) CENTER OF SAN MH, 53.35' (C) MAG NAIL SET UP 1.0' ON N FACE OF PP# 201145, 167.00' (D) T.B.M. 476, CUT X ON SSE BONNET BOLT OF HYD (A) (B) (C) C.P. 176 N = 50710.6996 E = 60692.0669 CONTROL POINT 175 (MAG NAIL FLUSH) - O.P.O.T. STA. 50+77.44', -27.22' (L) LINE "B" (A) MAG NAIL SET UP 1.0' ON S FACE PP# 300667, 61.38' (B) CENTER OF GAS VALVE IN WALK, 10.85' (C) MAG NAIL FND UP 1.0' ON E FACE PP# 086533, 33.87' (D) MAG NAIL SET UP 1.0' ON N FACE PP# 300669, 76.66' LINE "B"(A) (B) (C)(D) C.P. 175 N = 50444.4976 E = 60689.8885 DRIVEGUILFORD RD. SHELL LINE "B" GUILFORD RD. (D) A.J.W. RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALEINDIANA DEPARTMENT OF TRANSPORTATION M.B. A.P. M.B. 4/2/2018 VERTICAL SCALE 1383180 1383180 R-36906 76ERR 1 S EF SPRONO. ASTATE OF D NIO IN LA AI N 01306 NGINE 27 EERIGEETS DANDREW J OHN W OLFDIRECTORY PATH: R:\Active\Carmel\Guilford Road Des. No. 1383180\CAD\PlansFILENAME: PP-B.dwgDATE/USER: 7/20/2018 4:25 PM / AwolfPLAN AND PROFILE LINE "B" 1"=30' 1"=5' 835 830 825 840 845 850 855 18 835 830 825 840 845 850 855MATCH LINE 49+25 "B" AUBREY S. & JANIE D. NARAINE TERESA ANN KANE MAIN & GUILFORD PLAZA LLC N. GUILFORD ROADLine "B"MATT D. MITCHEL (grass)(conc. walk)(conc. walk)+29,18' (conc)(conc. walk)(grass)(grass)SHOTZIE LLC Sec. 25, T18N, R3E Clay Township Hamilton County Sec. 25, T18N, R3E Clay Township Hamilton County W. MAIN ST. SEAN SUTTON & KAREN VONKAMECKE ALTA JANE ROTHFUSS TRUSTEE OF ALTA JANE ROTHFUSS REV TRUST ROSALIE M. DAVENPORT AMANDA L. GILL SANDRA JO WILSON & KELLY M. SEYER MARILYN K. MELANGTONJAMES & PAULA S. QUINN Line "S-1-B" & Section Line 8+007+009+0011+0012+0013+00App. Exist. R/W App. Exist. R/W App. Exist. R/W App. Exist. R/W+79,32'(asph)(asph) (awning) (conc walk) (grass) (conc walk) (grass) (conc walk) (conc walk) T.B.M. 471 C.P. 170+26.3, 28.8', Inlet+29.9, 33.3', Rnd. Inlet+42.4, 28.5', Monitoring Well+27.2, 26.8', Sign (W11A-2)+53.1, 37.7', Monitoring Well+56.4, 39.9', Irr. Valve+65.6, 48.7', Fire Hyd.+44.5, 47.6', Irr. Valve+60.4, 33.5', Signal Pole+61.5, 48.5', PP w/Riser+90.8, 40.8', Detector+37.0, 18.0', Traf. M.H.+46.2, 34.2', Power Pole+16.8, 36.7', 6" Dec.+47.0, 38.0', Water Meter+71.3, 21.0', Mailbox+73.1, 37.8', Yard Light+97.1, 18.5', Power Pole+96.6, 19.0',???+01.9, 14.1', Inlet+04.2, 20.0', Sign Carmel Hospitality+47.5, 5.3', Detector+41.5, 30.3', 6" Con.+42.3, 40.9', 3" Con.+61.4, 25.0', 6" Dec.+76.2, 22.8', Water Meter+19.4, 12.3', Inlet+23.4, 39.8', 12" Dec.+46.3, 31.3', Sign (Stop)+52.7, 34.6',San. M.H.+84.2, 27.3',Sign (30 MPH)+38.9, 44.3',Water Meter+49.2, 24.4',Traf. M.H.+53.5, 33.6',Elec. Box conc+46.7, 49.0',6" Dec.+51.9, 46.6',Gas Vavle+51.5, 46.7',Gas Marker+04.9, 41.0',6" Dec.+14.9, 28.6',Rnd. Inlet+31.8, 40.0',3" Dec.+48.6, 40.0',Fire Hyd.+63.5, 19.3',Water Valve+58.6, 39.2',6" Dec.+81.6, 38.1',3" Dec.+51.7, 34.9',San. M.H.+78.8, 20.3',Water Valve+71.7, 19.5',Water Valve+62.5, 45.5',3" Dec.+21.2, 27.3',Rnd. Inlet+21.0, 40.9',Curb Stop+21.0, 40.8',Water Valve+05.2, 36.7',3" Dec.+05.7, 37.1',3" Dec.+09.7, 47.8',Detector+25.1, 22.3',Water Valve+30.3, 31.1',Gas Marker+30.1, 34.6',San. M.H.+34.7, 43.9',Tele M.H.+47.4, 20.0',Signal Pole+73.3, 27.1',36" Dec.+30.8, 23.9',12" Con.+35.6, 21.8',6" Con.+52.3, 41.4',Tele M.H.+58.0, 18.7',12" Dec.+67.7, 18.5',12" Dec.+73.1, 17.7',18" Dec.+95.8, 17.0',Power Pole+95.8, 25.2',Guy Wire+32.1, 18.6',36" Stump+34.2, 18.5',6" Dec.+52.5, 19.0',24" Stump+64.9, 19.9',18" Dec.+96.7, 19.4',18" Dec.+93.1, 49.9',3" Dec.+18.2, 46.6',Light Pole+29.3, 45.7',12" Dec.+46.9, 45.2',60" Bush+87.2, 49.1',12" Con.+80.5, 36.0',Gas Marker+60.9, 44.2',24" Dec.+57.5, 34.6',Water Valve+51.6, 49.6',12" Dec.+95.0, 42.7',Sprinkler HeadN88°49'50"E N88°57'59"E N0°06'57"EN1°29'20"EP.I. STA: 10+00.00 (No Curve) BEGIN INCIDENTAL CONSTRUCTION 6+84.00 "S-1-B" BEGIN CONSTRUCTION 8+21.00 "S-1-B" END PROJECT 12+19.00 "S-1-B" END INCIDENTAL CONSTRUCTION 12+30.00 "S-1-B" 1 2 " P i p e 12" Pipe 12" Pipe 15" Pipe 15" Pipe15" Pipe 15" Pipe12" Pipe12" Pipe 12" Pipegas pumpgas pumpgas pumpgas pump(conc)+66.6, 58.4',Signal Pole12" Pipe (31 shrubs/mulch)+72.5, 53.2',Traf. M.H.+67.6, 71.9',Rnd. Inlet(conc. walk)(conc. walk)(17 shrubs/mulch)+98.0, 87.8', Bollard+01.6, 85.8', Bollard+24.0, 87.9', Bollard+27.5, 85.7', Bollard+50.0, 87.8', Bollard+75.9, 87.8', Bollard+79.4, 85.7', Bollard+54.0, 80.7', Monitoring Well+03.7, 62.3', Monitoring Well+05.7, 62.3', Monitoring Well+10.8, 83.3', Monitoring Well+42.7, 70.5',Brick Gas Sta. Sign+53.0, 56.1', Sign+55.8, 64.6', 2 Guy WiresLine "C"2+001 + 0 0 12" San.12" San.12" San.6" S a n . 12" Pipe (shrubs/mulch)(shrubs/mulch)App. Exist. R/WApp. Exist. R/W App. Exist. R/WConstr. Limits Constr. Limits Constr. Limits Constr. Limits Constr. Limits App PLApp PLApp PLApp PLApp PLApp PLApp PLApp PLApp. Exist. R/W10+00R/W Temp R/W for Drive Const. R /W Temp R/W for Drive Const.R/W R/W R/WR/WR/W+12 "B" 50' +43 "B" 60' +12 "S-1-B" 49' +12 "S-1-B" 42' +70 "S-1-B" 32' +95 "S-1-B" PL(30') +70 "S-1-B" 40' +44 "S-1-B" 40' +44 "S-1-B" 30' +31.58 "B" 40' +38.52 "B" 50' +60.79 "B" 35' +12 "S-1-B" 30' +88 "S-1-B" 40' +02 "B" 49' +64 "B" 30' Temp R/W for Grading +97 "S-1-B" PL(42') +83 "S-1-B" 47' +34 "B" 47' +10 "B" PL(40') +19 "S-1-B" PL(50') +08 "B" PL(40') Str. No. 81 Str. No. 80 Str. No. 82 Str. No. 83 Str. No. 84 92°39'31" 88°42'53"91°8'58" 87°28'38" 7+00 8+00 9+00 10+00 11+00 12+00 13+00845.92846.05846.22846.39846.60846.80847.12847.46847.83848.13848.41848.84849.13849.63850.09850.62850.82850.99850.39849.15847.76846.38845.17844.12843.11842.11841.05839.97838.94837.94836.93846.39846.59846.83847.11847.44847.79848.14848.49+0.73% +1.40% PVI STA: 7+53.57 PVI ELEV: 846.79 VCL: 96.00 -4.00%-4.00% BEGIN INCIDENTAL CONSTRUCTION STA. 6+83.34 ELEV. 846.27 END INCIDENTAL CONSTR. STA. 12+29.06 ELEV. 842.96 Exist. Grade @ Line "S-1-B" Proposed Grade Proposed Grade 847.13846.13845.13844.13843.13BEGIN CONSTRUCTION STA. 8+21 "A" ELEV. = 847.77 END CONSTRUCTION STA. 12+19 "A" ELEV. = 843.37 SEE THE PROFILES AND SPOT ELEVATION SHEETS FOR ROUNDABOUT GRADES Str. No. 81 12"∅ Pipe @ 0.51% Str. No. 80 12"∅ Pipe @ 0.50% Str. No. 82 12"∅ Pipe @ 0.50% Str. No. 83 12"∅ Pipe @ 0.50% Str. No. 84 All R/W and Topo from Line "S-1-B" Unless Noted Otherwise PROPOSED (See Typical Sheet for Additional Details) Concrete Curb (Barrier)14 Mill and OverlayR 15 Sodding26 16 LEGEND EXISTING Storm Manhole Gas Line Storm Inlets Sanitary Manhole Gas Valve Gas Meter Sanitary Cleanout Water Line Water Valve Fire Hydrant Sprinkler Electric Line Power Pole w/(Riser) Light & Power Pole Light & Power Pole w/Riser Water Meter Light Pole Guy Wire Electric Box Fiber Optic Line Telephone Line Telephone Manhole Cable TV Line Cable TV Box Telephone Riser Utility Manhole Wood Fence Iron Pin Sign Flag Pole Bush Tree Trunk Deciduous Tree Coniferous Tree Overhead Utility Line Wood Fence Wire Fence Chainlink Fence Iron Fence Irr. Valve Mailbox Concrete Sidewalk, 4"F 18 Concrete Center Curb, Type 'D'19 Combined Concrete Curb & Gutter (Barrier) Modified Roll Curb Combined Concrete Curb & Gutter (Barrier) (Dry) Concrete Curb Ramp C2 PCCP, 7" with D-1 Contraction Joints Spaced at 14' Max. HMA for SidewalkP Asphalt ShoulderJ C PCCP, For Approaches 6" on Subgrade Treatment Type II. H C1 PCCP, For Approaches 9" on Subgrade Treatment Type II. Retaining WallW Full Depth Asphalt PavementK1 Removal (Pvmt, Sidewalk, Concrete) D HMA For Approaches (See Typical Sheet for Additional Details) TBM #474 - Cut " " on SW Corner of Square Concrete Light Pole Foundation in Parking Lot at SE Corner of 852 W. Main St. Sta. 5+10.70 "S-1-B", 93.46'' Lt., Elev. = 847.88' TBM #471 - Cut "X" on WNW Bonnet Bolt of Fire Hydrant. Sta. 39+12.52 "B", 26.67' Rt., Elev. = 836.47' TBM #472 - RR Spike set 1.0' up on W. face of Power Pole #185-562. Sta. 30+66.56 "B", 12.53' Rt., Elev. = 842.79' TBM #473 - Cut "X" on N Bonnet Bolt of Fire Hydrant. Sta. 22+78.42 "B", 42.79' Lt., Elev. = 844.99 TBM #478 -Cut "X" on NNE Bonnet Bolt of Fire Hydrant. Sta. 11+66.72 "B", 62.69' Rt., Elev. = 845.12' TBM #470 - Top of NW Corner of Bottom Porch Step Sta. 47+35.12 "B", 88.05' Rt., Elev. = 852.06' ORIGINATING BENCHMARK DESIGNATION - V 42 PID - LB0600 STATE/COUNTY - IN/HAMILTON USGS QUAD - WESTFIELD (1992) VERT ORDER - SECOND CLASS 0 DESCRIBED BY COAST AND GEODETIC SURVEY 1934 1.8 MILES SOUTH ALONG THE CHICAGO, INDIANAPOLIS AND LOUISVILLE RAILWAY FROM THE STATION AT WESTFIELD, HAMILTON COUNTY, 6 1 2 RAILS SOUTH OF CULVERT B-165.1 IN THE NORTHEAST ANGLE OF A GRAVEL ROAD, 9 YARDS EAST OF THE EAST RAIL, 6 YARDS NORTH OF THE CENTERLINE OF THE ROAD, AND ABOUT 3 FEET HIGHER THAN THE RAIL. A STANDARD DISK, STAMPED V 42 1934 AND SET IN THE TOP OF A CONCRETE POST PROJECTING ONE-HALF FOOT ABOVE GROUND. ELEVATION = 884.62 (NAVD 88) CONTROL POINT 174 (MAG NAIL FLUSH) - O.P.O.T. STA. 4+75.10', -39.34' (R) LINE "S-1-B" (A) CENTER OF WATER METER, 44.10' (B) N FACE OF AUTO SPRINKLER POLE UP 0.20', 5.02' (C) MAG NAIL IN W FACE OF PP #189550 UP 1.0', 101.35' (D) T.B.M. 474, - SW CRNR OF LIGHT POLE, W. MAIN (A) (B) (C) (D) C.P. 174 N = 50215.4962 E = 60184.8242 LINE "S-1-B" AMERICAN LEGION (A) MAG NAIL ON NW SIDE OF CONCRETE BASE OF TRAFFIC POLE, 13.34' (B) CUT "X" ON WEST SIDE OF TELEPHONE MH RIM, 18.82' (C) MAG NAIL SET ON W SIDE OF PP# 186109 UP 1.0', 69.93' (D) T.B.M. 470, TOP NW CRNR OF BOTTOM PORCH STEP ON N SIDE OF HOUSE, 66.85' N = 50155.7055 E = 60759.1670 CONTROL POINT 170 (MAG NAIL) - O.P.O.T. STA. 10+48.18', 32.05' (R) LINE "S-1-B" C.P. 170 (A) (B) (C) (D) GUILFORD RD. LINE "B"MAIN ST.LINE "S-1-B"A.J.W. RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALEINDIANA DEPARTMENT OF TRANSPORTATION M.B. A.P. M.B. 4/2/2018 VERTICAL SCALE 1383180 1383180 R-36906 76ERR 1 S EF SPRONO. ASTATE OF D NIO IN LA AI N 01306 NGINE 27 EERIGEETS DANDREW J OHN W OLFDIRECTORY PATH: R:\Active\Carmel\Guilford Road Des. No. 1383180\CAD\PlansFILENAME: PP-S-1-B.dwgDATE/USER: 7/20/2018 4:24 PM / ApercifieldPLAN AND PROFILE LINE "S-1-B" 1"=30' 1"=5' 835 830 825 840 845 850 855 19 835 830 825 840 845 850 855 Sec. 36, T18N, R3E Clay Township Hamilton County15+0016+0017+00HUNT LAKES OF CARMEL LLC PHASE I OF TIMBER RIDGE HORIZONTAL PROPERTY REGIME App. Exist. R/W (grass) Sec. 36, T18N, R3E Clay Township Hamilton County (conc walk)(bu s h e s )12" PipeEasementApp PLN0°01'40"W Line "B" EasementEasement S. GUILFORD ROAD App. Exist. R/W 13.4'14.9'8'R P Constr. Limits Constr. Limits Constr. Limits BEGIN PROJECT 14+95.30 "B" (asph) (asph) (asph) App. Exist. R/W Drainage, Utility and Sidewalk Easement App. Exist. R/W PROPOSED (See Typical Sheet for Additional Details) Concrete Curb (Barrier)14 Mill and OverlayR 15 Sodding26 16 Coniferous TreeMailbox Concrete Sidewalk, 4"F 18 Concrete Center Curb, Type 'D'19 Combined Concrete Curb & Gutter (Barrier) Modified Roll Curb Combined Concrete Curb & Gutter (Barrier) (Dry) Concrete Curb Ramp C2 PCCP, 7" with D-1 Contraction Joints Spaced at 14' Max. HMA for SidewalkP Asphalt ShoulderJ C PCCP, For Approaches 6" on Subgrade Treatment Type II. H C1 PCCP, For Approaches 9" on Subgrade Treatment Type II. Retaining WallW Full Depth Asphalt PavementK1 Removal (Pvmt, Sidewalk, Concrete) D HMA For Approaches (See Typical Sheet for Additional Details) A.J.W. RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALEINDIANA DEPARTMENT OF TRANSPORTATION M.B. A.P. M.B. 4/2/2018 VERTICAL SCALE 1383180 1383180 R-36906 76ERR 1 S EF SPRONO. ASTATE OF D NIO IN LA AI N 01306 NGINE 27 EERIGEETS DANDREW J OHN W OLFDIRECTORY PATH: R:\Active\Carmel\Guilford Road Des. No. 1383180\CAD\PlansFILENAME: CONSTR-DETAILS.dwgDATE/USER: 7/20/2018 4:24 PM / ApercifieldCONSTRUCTION DETAIL LINE "B" 1"=10' N/A MATCH LINE 17+50 "B"20 18+0019+0020+00PHASE II OF TIMBER RIDGE HORIZONTAL PROPERTY REGIME App. Exist. R/W App. Exist. R/W (grass) (grass) (grass) (conc walk)12" Pipe15" Pipe18" Pipe Easement Constr. Limits Sec. 36, T18N, R3E Clay Township Hamilton County Sec. 36, T18N, R3E Clay Township Hamilton County PHASE I OF TIMBER RIDGE HORIZONTAL PROPERTY REGIME HUNT LAKES OF CARMEL LLC N0°01'40"W Line "B" S. GUILFORD ROAD13.7'14.7'8'R P Easement App. Exist. R/W Constr. Limits (asph) Drainage, Utility and Sidewalk Easement PROPOSED (See Typical Sheet for Additional Details) Concrete Curb (Barrier)14 Mill and OverlayR 15 Sodding26 16 Coniferous TreeMailbox Concrete Sidewalk, 4"F 18 Concrete Center Curb, Type 'D'19 Combined Concrete Curb & Gutter (Barrier) Modified Roll Curb Combined Concrete Curb & Gutter (Barrier) (Dry) Concrete Curb Ramp C2 PCCP, 7" with D-1 Contraction Joints Spaced at 14' Max. HMA for SidewalkP Asphalt ShoulderJ C PCCP, For Approaches 6" on Subgrade Treatment Type II. H C1 PCCP, For Approaches 9" on Subgrade Treatment Type II. Retaining WallW Full Depth Asphalt PavementK1 Removal (Pvmt, Sidewalk, Concrete) D HMA For Approaches (See Typical Sheet for Additional Details) A.J.W. RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALEINDIANA DEPARTMENT OF TRANSPORTATION M.B. A.P. M.B. 4/2/2018 VERTICAL SCALE 1383180 1383180 R-36906 76ERR 1 S EF SPRONO. ASTATE OF D NIO IN LA AI N 01306 NGINE 27 EERIGEETS DANDREW J OHN W OLFDIRECTORY PATH: R:\Active\Carmel\Guilford Road Des. No. 1383180\CAD\PlansFILENAME: CONSTR-DETAILS.dwgDATE/USER: 7/20/2018 4:24 PM / ApercifieldCONSTRUCTION DETAIL LINE "B" 1"=10' N/A MATCH LINE 20+50 "B"21MATCH LINE 17+50 "B" 21+0022+00NEW BUFFALO LAND IMPROVEMENTW. 126th ST.(grass)Section LineSection Line(trees) (trees) (grass)(conc walk)(asph)(asph path) Street Approach W=20' +99 C.P. 173 N0°01'40"W P.I. STA: 21+85.45 (No Curve) N0°06'57"E 12" Pipe1 2 " P i p e 10" San.12" San.EasementApp PL+18+48Constr. Limits PHASE II OF TIMBER RIDGE HORIZONTAL PROPERTY REGIME Sec. 36, T18N, R3E Clay Township Hamilton County Sec. 36, T18N, R3E Clay Township Hamilton County HUNT LAKES OF CARMEL LLC EasementSec. 25, T18N, R3E Clay Township Hamilton County Sec. 25, T18N, R3E Clay Township Hamilton County TWIN LAKES APARTMENTS OF CARMEL LLC App. Exist. R/W Drainage, Utility and Sidewalk Easement App. Exist. R/W Easement S. GUILFORD ROAD Line "B"App. Exist. R/WApp. Exist. R/W Constr. Limits Constr. Limits 14'14'0°8'37" 40' Utility Easement R40'R K1 15 14 15 PP R 26 P 13.9'14.4'8'H 19 14 REMOVE App. Exist. R/W Str. No. 23, +40 "B" Manhole 'C-4' with 280' of 18" Pipe Str. No. 21, +40 "B" Inlet 'C-15' with 18' of 18" Pipe Str. No. 22A, +53 "B" Inlet 'B-15' with 13' of 12" Pipe Str. No. 21A, +53 "B" Inlet 'B-15' with 13' of 12" Pipe Str. No. 22, +40 "B" Inlet 'C-15' with 17' of 12" Pipe Str. No. 20, +22 "B" Inlet 'E-7' with 30' of 15" Pipe REMOVE Monument, B 10 Tons Revetment Riprap on 7 Sys. Geotextile, Type 1A +39D Easement Easement14'14'4'14'3'10'21' ADJUST SAN MH TO GRADE F PROPOSED (See Typical Sheet for Additional Details) Concrete Curb (Barrier)14 Mill and OverlayR 15 Sodding26 16 Coniferous TreeMailbox Concrete Sidewalk, 4"F 18 Concrete Center Curb, Type 'D'19 Combined Concrete Curb & Gutter (Barrier) Modified Roll Curb Combined Concrete Curb & Gutter (Barrier) (Dry) Concrete Curb Ramp C2 PCCP, 7" with D-1 Contraction Joints Spaced at 14' Max. HMA for SidewalkP Asphalt ShoulderJ C PCCP, For Approaches 6" on Subgrade Treatment Type II. H C1 PCCP, For Approaches 9" on Subgrade Treatment Type II. Retaining WallW Full Depth Asphalt PavementK1 Removal (Pvmt, Sidewalk, Concrete) D HMA For Approaches (See Typical Sheet for Additional Details) A.J.W. RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALEINDIANA DEPARTMENT OF TRANSPORTATION M.B. A.P. M.B. 4/2/2018 VERTICAL SCALE 1383180 1383180 R-36906 76ERR 1 S EF SPRONO. ASTATE OF D NIO IN LA AI N 01306 NGINE 27 EERIGEETS DANDREW J OHN W OLFDIRECTORY PATH: R:\Active\Carmel\Guilford Road Des. No. 1383180\CAD\PlansFILENAME: CONSTR-DETAILS.dwgDATE/USER: 7/20/2018 4:24 PM / ApercifieldCONSTRUCTION DETAIL LINE "B" 1"=10' N/AMATCH LINE 22+75 "B"22MATCH LINE 15+25 "B" 23+0024+0025+00TWIN LAKES APARTMENTS OF CARMEL LLC GUILFORD COMMONS LLC S. GUILFORD ROAD Line "B"WATERLILY WAYSec. 25, T18N, R3E Clay Township Hamilton County (grass) (grass)(asph)Street Approach W=26' +48 T.B.M. 473 +93.1 12" San.6" San.12" San.8" San.App. Exist. R/W (asph path) App. Exist. R/W Constr. Limits +93.1 +03.1 +53.1 +03.1 Temp R/W for Drive Const. 12" San. Constr. Limits Sec. 25, T18N, R3E Clay Township Hamilton County NEW BUFFALO LAND IMPROVEMENT Constr. Limits 18'18'18'18'22'12'18'18'8'4'12'12'R4 0 ' R40' 26 R K1 15 15 15 P P 26 19 14 14 14 App. Exist. R/W R5' R5' Constr. Limits App. Exist. R/W H F H(asph path) +PL(+71 )"B" 39' +PL(+22 )"B" 39' +71 "B" 81' +25 "B" 81' Str. No. 27, +20 "B" Manhole 'C-4' with 135' of 21" Pipe Str. No. 25, +20 "B" Inlet 'C-15' with 19' of 12" Pipe Str. No. 26, +20 "B" Inlet 'B-15' with 19' of 12" Pipe Str. No. 24, +20 "B" Inlet 'E-7' with 18' of 12" Pipe D12'12'2'6'4'26'+899'8'4'12'3'10'ADJUST SAN MH TO GRADE ADJUST SAN MH TO GRADE PROPOSED Concrete Curb (Barrier)14 15 Coniferous TreeMailbox Concrete Sidewalk, 4"F Combined Concrete Curb & Gutter (Barrier) C2 PCCP, 7" with D-1 Contraction Joints Spaced at 14' Max. HMA for SidewalkP Asphalt ShoulderJ C PCCP, For Approaches 6" on Subgrade Treatment Type II. C1 PCCP, For Approaches 9" on Subgrade Treatment Type II. D HMA For Approaches (See Typical Sheet for Additional Details) Mill and OverlayR Sodding26 16 18 Concrete Center Curb, Type 'D'19 (Barrier) Modified Roll Curb Combined Concrete Curb & Gutter (Barrier) (Dry) Concrete Curb RampH Retaining WallW Full Depth Asphalt PavementK1 Removal (Pvmt, Sidewalk, Concrete) (See Typical Sheet for Additional Details) A.J.W. RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALEINDIANA DEPARTMENT OF TRANSPORTATION M.B. A.P. M.B. 4/2/2018 VERTICAL SCALE 1383180 1383180 R-36906 76ERR 1 S EF SPRONO. ASTATE OF D NIO IN LA AI N 01306 NGINE 27 EERIGEETS DANDREW J OHN W OLFDIRECTORY PATH: R:\Active\Carmel\Guilford Road Des. No. 1383180\CAD\PlansFILENAME: CONSTR-DETAILS.dwgDATE/USER: 7/20/2018 4:24 PM / ApercifieldCONSTRUCTION DETAIL LINE "B" 1"=10' N/A MATCH LINE 25+75 "B"23MATCH LINE 22+75 "B" 27+0028+00AMARJIT & BALWINDER KAUR h&w SINGH GUILFORD COMMONS LLC TWIN LAKES APARTMENTS OF CARMEL LLC (grass) (lawn) (grass) Class I Drive W = 16' Conc. +57(asph)CHIMNEY ROCK DR.+57,16'(asph)Street Approach W=20' +01 12" P i p e 18" Pipe(asph. path) 12" Pipe 12" San.App. Exist. R/W App PLConstr. Limits +13Constr. Limits +63Constr. Limits Temp R/W for Drive Const. App. Exist. R/W Sec. 25, T18N, R3E Clay Township Hamilton County Sec. 25, T18N, R3E Clay Township Hamilton County App. Exist. R/W S. GUILFORD ROAD Line "B" App. Exist. R/W26+0011.5'5'12'12'12'12'22'2'4'8'R10'R20'R4 0 ' R40' 14 14 26 K1 K1 R 14 14 K1 1818 C F F 19 P 28+00H H No Work Required Adjust Casting to Grade, Storm +56+81 "B" 81' +PL(+21.99 )"B" 81' +PL(+81 )"B" 39' Str. No. 29A, +47 "B" Inlet 'B-15' with 8' of 12" Pipe Str. No. 30, +55 "B" Inlet 'C-15' with 19' of 12" Pipe Str. No. 29, +55 "B" Inlet 'C-15' with 19' of 15" Pipe Str. No. 30A, +47 "B" Inlet 'B-15' with 8' of 12" Pipe Replace with Type 4 Casting, Adjust to Grade Str. No. 28, +55 "B" Inlet 'E-7' with 18' of 15" Pipe +74D Str. No. 31, +55 "B" Manhole 'C-4' with 156' of 24" Pipe 8'10'8'4'12'3'10'ADJUST SAN MH TO GRADE PROPOSED (See Typical Sheet for Additional Details) Concrete Curb (Barrier)14 Mill and OverlayR 15 Sodding26 16 Coniferous TreeMailbox Concrete Sidewalk, 4"F 18 Concrete Center Curb, Type 'D'19 Combined Concrete Curb & Gutter (Barrier) Modified Roll Curb Combined Concrete Curb & Gutter (Barrier) (Dry) Concrete Curb Ramp C2 PCCP, 7" with D-1 Contraction Joints Spaced at 14' Max. HMA for SidewalkP Asphalt ShoulderJ C PCCP, For Approaches 6" on Subgrade Treatment Type II. H C1 PCCP, For Approaches 9" on Subgrade Treatment Type II. Retaining WallW Full Depth Asphalt PavementK1 Removal (Pvmt, Sidewalk, Concrete) D HMA For Approaches (See Typical Sheet for Additional Details) A.J.W. RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALEINDIANA DEPARTMENT OF TRANSPORTATION M.B. A.P. M.B. 4/2/2018 VERTICAL SCALE 1383180 1383180 R-36906 76ERR 1 S EF SPRONO. ASTATE OF D NIO IN LA AI N 01306 NGINE 27 EERIGEETS DANDREW J OHN W OLFDIRECTORY PATH: R:\Active\Carmel\Guilford Road Des. No. 1383180\CAD\PlansFILENAME: CONSTR-DETAILS.dwgDATE/USER: 7/20/2018 4:24 PM / ApercifieldCONSTRUCTION DETAIL LINE "B" 1"=10' N/AMATCH LINE 28+00 "B"24MATCH LINE 25+75 "B" 29+0030+0031+00EQUITY TRUST COMPANY CUSTODIAN FBO DAVID M. WALTERS MICHAEL D. & CAROL L. KEEN CARMEL CLAY SCHOOLS S. GUILFORD ROAD Line "B"HELEN KEEN CT.(conc. walk) (asph. path) (lawn) (lawn)+35,22'(asph)(asph)+90,12'(asph)(conc)(conc)(conc walk)(conc walk)(conc) Class I Drive W = 12' Conc. +90 Class I Drive W = 12' Conc. +54 Street Appr. W=55' +84 Street Approach W=22' +35 (grass) T.B.M. 472 N0°06'57"E12" Pipe12" Pipe 12" Pipe GRAND BLVD.36" Pipe36" Pipe 24" Pipe 12" Pipe2 4 " P i p e 12" Pipe12" San.12" San.App. Exist. R/WApp. Exist. R/W(conc. walk) App. Exist. R/W App PL+13+52+45+95Sec. 25, T18N, R3E Clay Township Hamilton County Sec. 25, T18N, R3E Clay Township Hamilton County App PL+84,55'App. Exist. R/W12" San. App. Exist. R/W(asph. path)(grass) S. GUILFORD ROAD AMARJIT & BALWINDER KAUR h&w SINGHApp. Exist. R/W Constr. Limits Constr. Limits Constr. Limits 11.5'5'2'12'22'12'12'12'R40 ' R 4 0 ' R40'R20'R 1 0 'R10'R20'R6'R23' 19 P F F R R F 15 15 15 D R F C 26 F F F 14 14 D 15 15 CF App. Exist. R/W28+0031+00Sec. 25, T18N, R3E Clay Township Hamilton County HH H H 15 19App. Exist. R/W A p p . E x i s t . R /W K1 REMOVE EXISTING INLET AND PLUG PIPE Adjust Casting to Grade A p p . E x i s t . R /W Str. No. 41, +88 "B" Manhole 'C-4' with 332' of 24" Pipe Str. No. 40, +12 "B" Inlet 'B-15' with 29' of 12" Pipe Str. No. 34, +17 "B" Inlet 'B-15' with 70' of 12" Pipe Str. No. 39, +88 "B" Inlet 'B-15' with 19' of 12" Pipe Str. No. 33, +48 "B" Inlet 'C-15' with 41' of 12" Pipe Str. No. 38, +11 "B" Manhole 'C-4' with 177' of 24" Pipe Str. No. 32, +11 "B" Inlet 'C-15' with 19' of 12" Pipe Str. No. 37, +11 "B" Inlet 'B-15' with 19' of 12" Pipe +35+06P+85Constr. Limits 3'11.5'5'5'30'18'8' 6'8'+43.5 57'9.6'10.5'2'6'4'10'10'ADJUST SAN MH TO GRADE (See Typical Sheet for Additional Details) Mill and OverlayR Sodding26 16 18 Concrete Center Curb, Type 'D'19 Modified Roll Curb Combined Concrete Curb & Gutter (Barrier) (Dry) Concrete Curb RampH Retaining WallW Full Depth Asphalt PavementK1 Removal (Pvmt, Sidewalk, Concrete) (See Typical Sheet for Additional Details) PROPOSED Concrete Curb (Barrier)14 15 Coniferous TreeMailbox Concrete Sidewalk, 4"F Combined Concrete Curb & Gutter (Barrier) C2 PCCP, 7" with D-1 Contraction Joints Spaced at 14' Max. HMA for SidewalkP Asphalt ShoulderJ C PCCP, For Approaches 6" on Subgrade Treatment Type II. C1 PCCP, For Approaches 9" on Subgrade Treatment Type II. D HMA For Approaches A.J.W. RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALEINDIANA DEPARTMENT OF TRANSPORTATION M.B. A.P. M.B. 4/2/2018 VERTICAL SCALE 1383180 1383180 R-36906 76ERR 1 S EF SPRONO. ASTATE OF D NIO IN LA AI N 01306 NGINE 27 EERIGEETS DANDREW J OHN W OLFDIRECTORY PATH: R:\Active\Carmel\Guilford Road Des. No. 1383180\CAD\PlansFILENAME: CONSTR-DETAILS.dwgDATE/USER: 7/20/2018 4:24 PM / ApercifieldCONSTRUCTION DETAIL LINE "B" 1"=10' N/A 25MATCH LINE 28+00 "B"MATCH LINE 31+00 "B" 31+0032+0033+001802 CONDO LLC CARMEL CLAY SCHOOLS (conc. walk) (lawn) (lawn)+53,15'(asph)(asph)(conc walk)(conc. walk)(conc walk)Class I Drive W = 15' Conc. +53 (asph. path) Street Approach W=44' +08 Street Appr. W=30' +16 (grass)C.P. 172 24" Pipe 24" San.12" San.12" San. (conc. walk)App PLApp PLConstr. Limits+45+69+19+69Constr. Limits Temp R/W for Drive Const. CARMEL CLAY SCHOOLS App. Exist. R/W JULIE M. WEBB Sec. 25, T18N, R3E Clay Township Hamilton County App. Exist. R/WApp. Exist. R/WCOLLEGE WAY+16,30'(conc.) (asph)12" San. (asph. path) (grass) (grass)+08,44'1802 CONDO LLC Sec. 25, T18N, R3E Clay Township Hamilton County App. Exist. R/W (lawn)App PLSec. 25, T18N, R3E Clay Township Hamilton County Line "B" Constr. Limits Constr. Limits Constr. Limits App. Exist. R/W Constr. Limits11.5'5'11.5'5'2'18'18'22'12'R40'R40'R40' R4 0 'R20'R1 0 ' 15 19 15 C F R K1 K1 15 19 14 K1 F F F 15 F 26 12'12'12'10" Pi p e 24" Pipe H H HH 14 REMOVE EXISTING INLET AND PLUG PIPE +33 "B" 81' +78 "B" 81' +38 "B" PL(41') +73 "B" PL(41') +78 "B" 48' +33 "B" 51' App. Exist. R/W Str. No. 45, +20 "B" Manhole 'C-4' with 137' of 24" Pipe Str. No. 42, +20 "B" Inlet 'B-15' with 19' of 12" Pipe Str. No. 44, +20 "B" Inlet 'B-15' with 20' of 12" Pipe+32+1212" San . PP 6' 6'9.6'9.5'40' 44'10'24'5'4'4' 5.7'6'2'3'4'4'ADJUST SAN MH TO GRADE ADJUST SAN MH TO GRADE PROPOSED (See Typical Sheet for Additional Details) Concrete Curb (Barrier)14 Mill and OverlayR 15 Sodding26 16 Coniferous TreeMailbox Concrete Sidewalk, 4"F 18 Concrete Center Curb, Type 'D'19 Combined Concrete Curb & Gutter (Barrier) Modified Roll Curb Combined Concrete Curb & Gutter (Barrier) (Dry) Concrete Curb Ramp C2 PCCP, 7" with D-1 Contraction Joints Spaced at 14' Max. HMA for SidewalkP Asphalt ShoulderJ C PCCP, For Approaches 6" on Subgrade Treatment Type II. H C1 PCCP, For Approaches 9" on Subgrade Treatment Type II. Retaining WallW Full Depth Asphalt PavementK1 Removal (Pvmt, Sidewalk, Concrete) D HMA For Approaches (See Typical Sheet for Additional Details) A.J.W. RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALEINDIANA DEPARTMENT OF TRANSPORTATION M.B. A.P. M.B. 4/2/2018 VERTICAL SCALE 1383180 1383180 R-36906 76ERR 1 S EF SPRONO. ASTATE OF D NIO IN LA AI N 01306 NGINE 27 EERIGEETS DANDREW J OHN W OLFDIRECTORY PATH: R:\Active\Carmel\Guilford Road Des. No. 1383180\CAD\PlansFILENAME: CONSTR-DETAILS.dwgDATE/USER: 7/20/2018 4:24 PM / ApercifieldCONSTRUCTION DETAIL LINE "B" 1"=10' N/A MATCH LINE 33+75 "B"26MATCH LINE 31+00 "B" 34+0035+0036+00FRANK ANTHONY & KAREN S. RUTKKOWSKI RYAN D. MCHOME CARRIE E. STOCK (conc. walk) (asph. path) (grass) (grass) (lawn) (lawn) (lawn) (asph. path) Class I Drive W = 10' Conc. +45 +45,10'(asph)Class I Drive W = 15' Conc. +86+16,30'(asph)Class I Drive W = 10' Conc. +23 +24,19'(asph)+82,24'(asph)(grass) Street Approach W=24' +82 (grass) (conc. walk) 10" Pi p e 24" Pipe 1 8 " P i p e 15" Pipe15" Pipe 12" Pi p e 24" Pipe 24" Pipe12" Pipe (conc. walk)12" San.App PLApp PLApp. Exist. R/W App PLConstr. Limits (conc.)+30+80+30+34Constr. Limits Temp R/W for Drive Const. Temp R/W for Drive Const. Temp R/W for Drive Const. Sec. 25, T18N, R3E Clay Township Hamilton County (conc. walk) Line "B" S. GUILFORD ROAD Line "B" Constr. Limits Sec. 25, T18N, R3E Clay Township Hamilton County CARMEL CLAY SCHOOLS Temp R/W for Drive Const. App. Exist. R/W App. Exist. R/W App. Exist. R/W2'5'5'5'5'12'12'12'12'22'R40 ' R40'R20'R10'R 1 0 ' R1 0 'R20'R6'R6'26 14 14 C F C 19 15 15 F R 15 15 15 26 26 14 C D K126 F10" PipeConstr. Limits 12'12'F DAVID M. & ANGELA E. CONCANNON H H H H H 14 +36 "B" 57' +12 "B" 58' +99 "B" 53' +75 "B" 53' +51 "B" 51' +37 "B" 51' +04 "B" 75'+60 "B" 75' +36 "B" PL(40') +12 "B" PL(40')+99 "B" PL(40') +75 "B" PL(40')+51 "B" PL(40') +37 "B" PL(40') +11 "B" PL(40') +60 "B" PL(40') +11 "B" 45' +04 "B" 46' Str. No. 47B, +91 "B" Inlet 'E-7' with 34' of 12" Pipe Str. No. 48, +57 "B" Manhole 'J-4' with 178' of 27" Pipe Str. No. 47, +60 "B" Inlet 'C-15' with 20' of 12" Pipe Str. No. 46, +70 "B" Inlet 'B-15' with 23' of 12" Pipe Str. No. 54, +35 "B" Manhole 'J-4' with 156' of 27" Pipe Str. No. 50, +35 "B" Inlet 'C-15' with 19' of 12" Pipe Str. No. 53, +46 "B" Inlet 'C-15' with 22' of 12" Pipe Str. No. 49, +46 "B" Inlet 'B-15' with 89' of 12" Pipe Str. No. 51, +93 "B" Inlet 'E-7' with 16' of 12" Pipe Str. No. 52, +92 "B" Inlet 'C-15' with 53' of 12" Pipe Str. No. 47A, +22 "B" Inlet 'F-7' with 42' of 12" Pipe +22+66+96REMOVE INLET AND PLUG PIPE REMOVE F P P R20'5'11.5'10'8.7'10'11.5'+10+006'+7410'7.8'24'10'12'4'3'ADJUST SAN MH TO GRADE F PROPOSED (See Typical Sheet for Additional Details) Concrete Curb (Barrier)14 Mill and OverlayR 15 Sodding26 16 Coniferous TreeMailbox Concrete Sidewalk, 4"F 18 Concrete Center Curb, Type 'D'19 Combined Concrete Curb & Gutter (Barrier) Modified Roll Curb Combined Concrete Curb & Gutter (Barrier) (Dry) Concrete Curb Ramp C2 PCCP, 7" with D-1 Contraction Joints Spaced at 14' Max. HMA for SidewalkP Asphalt ShoulderJ C PCCP, For Approaches 6" on Subgrade Treatment Type II. H C1 PCCP, For Approaches 9" on Subgrade Treatment Type II. Retaining WallW Full Depth Asphalt PavementK1 Removal (Pvmt, Sidewalk, Concrete) D HMA For Approaches (See Typical Sheet for Additional Details) A.J.W. RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALEINDIANA DEPARTMENT OF TRANSPORTATION M.B. A.P. M.B. 4/2/2018 VERTICAL SCALE 1383180 1383180 R-36906 76ERR 1 S EF SPRONO. ASTATE OF D NIO IN LA AI N 01306 NGINE 27 EERIGEETS DANDREW J OHN W OLFDIRECTORY PATH: R:\Active\Carmel\Guilford Road Des. No. 1383180\CAD\PlansFILENAME: CONSTR-DETAILS.dwgDATE/USER: 7/20/2018 4:24 PM / ApercifieldCONSTRUCTION DETAIL LINE "B" 1"=10' N/A MATCH LINE 36+75 "B"27MATCH LINE 33+75 "B" 37+0038+0039+00PAUL J. MILLER Line "B"EMERSON RD.App. Exist. R/W App. Exist. R/W(grass)+10,17'(asph)Class I Drive W = 17' Conc. +10 +68,35'(asph)Street Approach W=30' +63+63,30'(asph)(conc. walk)(conc. walk)T.B.M. 471 N0°06'57"E 24" Pipe 12" Pipe 24" Pipe 12" Pipe24" Pipe 24" Pip e 12" Pipe 12" Pipe 12" San.8" San.App PL+09+59+09Street Approach W=35' +68 Temp R/W for Drive Const. Temp R/W for Drive Const. R/W R/W Constr. Limits CARMEL CLAY SCHOOLS 12" San.App. Exist. R/WCARMEL CLAY SCHOOLS Sec. 25, T18N, R3E Clay Township Hamilton County DAVID M. & ANGELA E. CONCANNON Constr. Limits Constr. Limits Constr. Limits App. Exist. R/W Constr. Limits App. Exist. R/W5'5'2'12'22'12'12'R40'R40 ' R 4 0 'R40'R10'R20'F 19 C R 15P F F 15 R D D 15 15 F F F 14 14 26 App. Exist. R/W Sec. 25, T18N, R3E Clay Township Hamilton County DAVID M. & ANGELA E. CONCANNON 11.5'5'HH H H K1 REMOVE EXISTING INLET AND PLUG PIPE REMOVE +02 "B" PL(50') +36 "B" PL(50') +81 "B" PL(40') +21.50 "B" PL(40')+98.01 "B" PL(40') +02 "B" 91' +36 "B" 91' +21.50 "B" 54'+98 "B" 53' +81 "B" 50' Str. No. 58, +91 "B" Manhole 'J-4' with 140' of 27" Pipe Str. No. 55, +91 "B" Inlet 'B-15' with 19' of 12" Pipe Str. No. 57, +91 "B" Inlet 'C-15' with 19' of 12" Pipe Str. No. 56, +62 "B" Inlet 'E-7' with 33' of 12" PipeStr. No. 56A, +98 "B" 24' of 15" Pipe and 2 Pipe End Sections REMOVE+84P 12'3'4'11.5'5'36'10'7.7'10'+84+3429' 6'10'Str. No. SS-3 PROPOSED (See Typical Sheet for Additional Details) Concrete Curb (Barrier)14 Mill and OverlayR 15 Sodding26 16 Coniferous TreeMailbox Concrete Sidewalk, 4"F 18 Concrete Center Curb, Type 'D'19 Combined Concrete Curb & Gutter (Barrier) Modified Roll Curb Combined Concrete Curb & Gutter (Barrier) (Dry) Concrete Curb Ramp C2 PCCP, 7" with D-1 Contraction Joints Spaced at 14' Max. HMA for SidewalkP Asphalt ShoulderJ C PCCP, For Approaches 6" on Subgrade Treatment Type II. H C1 PCCP, For Approaches 9" on Subgrade Treatment Type II. Retaining WallW Full Depth Asphalt PavementK1 Removal (Pvmt, Sidewalk, Concrete) D HMA For Approaches (See Typical Sheet for Additional Details) A.J.W. RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALEINDIANA DEPARTMENT OF TRANSPORTATION M.B. A.P. M.B. 4/2/2018 VERTICAL SCALE 1383180 1383180 R-36906 76ERR 1 S EF SPRONO. ASTATE OF D NIO IN LA AI N 01306 NGINE 27 EERIGEETS DANDREW J OHN W OLFDIRECTORY PATH: R:\Active\Carmel\Guilford Road Des. No. 1383180\CAD\PlansFILENAME: CONSTR-DETAILS.dwgDATE/USER: 7/20/2018 4:24 PM / ApercifieldCONSTRUCTION DETAIL LINE "B" 1"=10' N/AMATCH LINE 39+25 "B"28MATCH LINE 36+75 "B" 40+0041+0042+00(concrete s l o p e w a l l ) App. Exist. R/W (conc. walk ) (conc. walk) (grass) (asph. p a t h ) (grass) 24" P i p e 24" P i p e 24" Pipe 24" Pipe 12" Pipe108" CMP12" Pipe (Conc. P.S.D.) CARMEL CLAY SCHOOLS8" San.12" San. 12" San. WILSON VILLAGE CONDOMINIUMSApp PL+77.1 +27Constr. Limits Constr. Limits Constr. Limits R/WR/WR/WR/W 12" San. R/W CARMEL CLAY SCHOOLS Sec. 25, T18N, R3E Clay Township Hamilton County Sec. 25, T18N, R3E Clay Township Hamilton County App. Exist. R/W App. Exist. R/W Constr. Limits Constr. Limits11.5'5'2'32'12'11.5'5'10'28'18'6'12'22'P REMOVE 19 26 P 26 15 14 K1 14 15 K115 15 F 174 Tons Class I Riprap on 174 Sys. Geotextile, Type 1A 38 Tons Class I Riprap on 37 Sys. Geotextile, Type 1A Constr. LimitsF+27.1REMOVE EXISTING INLET AND PLUG PIPE +29 "B" 50' +29 "B" 62' +85 "B" 62' +85 "B" 50' +30 "B" PL(40') +13 "B" 68' +03 "B" 74' +72 "B" 81' +61.83 "B" 87' +81 "B" 57' +58 "B" 93'+26 "B" 93' +26 "B" PL(40') +03 "B" PL(40') Perpetual Drainage Easement Temp R/W for Grading Str. No. 68, +00 "B" Manhole 'C-4' with 172' of 18" Pipe Str. No. 70, +00 "B" Inlet 'B-15' with 19' of 12" Pipe Str. No. 69, +00 "B" Inlet 'B-15' with 29' of 12" Pipe Str. No. 61, +30 "B" Manhole 'J-4' with 19' of 27" Pipe Str. No. 66, +28 "B" Manhole 'C-4' with 25' of 18" Pipe Str. No. 67, +50 "B" Inlet 'B-15' with 36' of 12" Pipe Str. No. 65, +12 "B" Inlet 'C-15' with 44' of 18" Pipe Str. No. 62, +30 "B" Manhole 'J-15' Modified, with 31' of 27" Pipe Str. No. 62A, +38 "B" Inlet 'B-15' with 8' of 12" Pipe Str. No. 60A, +38 "B" Inlet 'B-15' with 8' of 12" Pipe Str. No. 60, +30 "B" Inlet 'C-15' with 29' of 12" Pipe Str. No. 64, +50 "B" Inlet 'E-7' with 39' of 12" Pipe Remove 7 Lft. of Pipe Remove 11 Lft. of Pipe Str. No. 63, +04 "B" 16' x 6' x 103' REINFORCED CONCRETE BOX CULVERT W/WINGWALLS K1 Replace with Type 4 Casting, Adjust to Grade Line "B"28'6'4'12'3'Str. No. SS-4 Str. No. SS-2 Str. No. SS-1 See Sanitary Plan and Profile for Sanitary Sewer Construction Notes and Profile PROPOSED Concrete Curb (Barrier)14 15 Coniferous TreeMailbox Concrete Sidewalk, 4"F Combined Concrete Curb & Gutter (Barrier) C2 PCCP, 7" with D-1 Contraction Joints Spaced at 14' Max. HMA for SidewalkP Asphalt ShoulderJ C PCCP, For Approaches 6" on Subgrade Treatment Type II. C1 PCCP, For Approaches 9" on Subgrade Treatment Type II. D HMA For Approaches (See Typical Sheet for Additional Details) Mill and OverlayR Sodding26 16 18 Concrete Center Curb, Type 'D'19 (Barrier) Modified Roll Curb Combined Concrete Curb & Gutter (Barrier) (Dry) Concrete Curb RampH Retaining WallW Full Depth Asphalt PavementK1 Removal (Pvmt, Sidewalk, Concrete) (See Typical Sheet for Additional Details) A.J.W. RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALEINDIANA DEPARTMENT OF TRANSPORTATION M.B. A.P. M.B. 4/2/2018 VERTICAL SCALE 1383180 1383180 R-36906 76ERR 1 S EF SPRONO. ASTATE OF D NIO IN LA AI N 01306 NGINE 27 EERIGEETS DANDREW J OHN W OLFDIRECTORY PATH: R:\Active\Carmel\Guilford Road Des. No. 1383180\CAD\PlansFILENAME: CONSTR-DETAILS.dwgDATE/USER: 7/20/2018 4:24 PM / ApercifieldCONSTRUCTION DETAIL LINE "B" 1"=10' N/A MATCH LINE 42+25 "B"29MATCH LINE 39+25 "B" 43+0044+00CARMEL CLAY SCHOOLS App. Exist. R/W Street Appr. W=33' +26+22,33(asph)(conc. walk) (grass) (grass) (conc. walk) (grass) (grass) (grass) (bushes) (conc. walk) 15" Pipe (bushes) (Face of Exist. Bldg.) 12" San.8" San.WILSON VILLAGE CONDOMINIUMS GUILFORD TRAIL TOWNHOMESApp PL+69+63+88+18.7 Constr. Limits Temp R/W for Drive Const. App. Exist. R/W Sec. 25, T18N, R3E Clay Township Hamilton County 12'11.5'5'10'28'18'6'12'22'2'4'22'18'18'11.5'5'6'10'R40'R40'R 6 ' Constr. Limits Constr. Limits App. Exist. R/W 15 15 D R F F P 26 14 14 15 15 R/W App. Exist. R/W P H H 19 K1 Do Not Disturb Sign FFFF +53 "B" PL(40') +99 "B" PL(40') +99 "B" 75' +53 "B" 75' Constr. Limits +PL(+19.47 )"B" 50'Str. No. 71, +90 "B" Manhole 'C-4' with 190' of 12" Pipe Str. No. 73, +90 "B" Inlet 'B-15' with 19' of 12" Pipe Str. No. 72, +90 "B" Inlet 'B-15' with 19' of 12" Pipe 19 +68.7 Line "B"12'30'10'ADJUST SAN MH TO GRADE ADJUST SAN MH TO GRADE PROPOSED (See Typical Sheet for Additional Details) Concrete Curb (Barrier)14 Mill and OverlayR 15 Sodding26 16 Coniferous TreeMailbox Concrete Sidewalk, 4"F 18 Concrete Center Curb, Type 'D'19 Combined Concrete Curb & Gutter (Barrier) Modified Roll Curb Combined Concrete Curb & Gutter (Barrier) (Dry) Concrete Curb Ramp C2 PCCP, 7" with D-1 Contraction Joints Spaced at 14' Max. HMA for SidewalkP Asphalt ShoulderJ C PCCP, For Approaches 6" on Subgrade Treatment Type II. H C1 PCCP, For Approaches 9" on Subgrade Treatment Type II. Retaining WallW Full Depth Asphalt PavementK1 Removal (Pvmt, Sidewalk, Concrete) D HMA For Approaches (See Typical Sheet for Additional Details) A.J.W. RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALEINDIANA DEPARTMENT OF TRANSPORTATION M.B. A.P. M.B. 4/2/2018 VERTICAL SCALE 1383180 1383180 R-36906 76ERR 1 S EF SPRONO. ASTATE OF D NIO IN LA AI N 01306 NGINE 27 EERIGEETS DANDREW J OHN W OLFDIRECTORY PATH: R:\Active\Carmel\Guilford Road Des. No. 1383180\CAD\PlansFILENAME: CONSTR-DETAILS.dwgDATE/USER: 7/20/2018 4:24 PM / ApercifieldCONSTRUCTION DETAIL LINE "B" 1"=10' N/AMATCH LINE 44+25 "B"30MATCH LINE 42+25 "B" 45+0046+00MIG GUILFORD RESERVE LLC S. GUILFORD ROAD Line "B"WILSON TERRACE CT.App. Exist. R/W Street Approach W=22' +94+96,22'(asph)+42,16'(asph)Class I Drive W = 16' Conc. +42 Class III Drive W = 24' Conc. +14 +14,24'(asph)N0°06'57"E (bushes)GUILFORD TRAIL DR.Street Approach W=24' +89 (conc. walk) (Face of Exist. Bldg.) 12" San. 8" San.8" San.8" San.12" San. WILSON VILLAGE CONDOMINIUMS App PLApp. Exist. R/W App. Exist. R/WApp. Exist. R/W+32+57+18+64Temp R/W for Drive Const. Temp R/W for Drive Const.18'19.7'10'6'2'12'4'12'12'22'18'18'11.5'5'6'10'2'R20'R20'R28'R 2 8 ' R20' R1 0 'R10 'R20'Constr. LimitsConstr. Limits 15 15 15 14 14 26 15 P P K1 C1 15 CF F 18 15 R58'R58'GUILFORD TRAIL TOWNHOMES App. Exist. R/W Sec. 25, T18N, R3E Clay Township Hamilton County AUBREY S. & JANIE D. NARAINE MAIN & GUILFORD PLAZA LLC 18 19 19 H H HH F F F R4' R 4 ' +30 "B" PL(40') +30 "B" 53' +54 "B" 53' +54 "B" 50' Temp R/W for Grading Constr. Limits FF D D +20 "B" 75' +70 "B" 75' +20 "B" PL(40') +70 "B" PL(40')R4'R4'Str. No. 76, +41 "B" Inlet 'B-15' with 19' of 12" Pipe Str. No. 75, +41 "B" Manhole 'C-4' with 151' of 12" Pipe Str. No. 77, +65 "B" Manhole 'C-4' with 123' of 12" Pipe Str. No. 78, +69 "B" Inlet 'B-15' with 29' of 12" Pipe+25R Line "B" 6' 21' 22' 21' 4'10'ADJUST SAN MH TO GRADE ADJUST SAN MH TO GRADE F +67PROPOSED (See Typical Sheet for Additional Details) Concrete Curb (Barrier)14 Mill and OverlayR 15 Sodding26 16 Coniferous TreeMailbox Concrete Sidewalk, 4"F 18 Concrete Center Curb, Type 'D'19 Combined Concrete Curb & Gutter (Barrier) Modified Roll Curb Combined Concrete Curb & Gutter (Barrier) (Dry) Concrete Curb Ramp C2 PCCP, 7" with D-1 Contraction Joints Spaced at 14' Max. HMA for SidewalkP Asphalt ShoulderJ C PCCP, For Approaches 6" on Subgrade Treatment Type II. H C1 PCCP, For Approaches 9" on Subgrade Treatment Type II. Retaining WallW Full Depth Asphalt PavementK1 Removal (Pvmt, Sidewalk, Concrete) D HMA For Approaches (See Typical Sheet for Additional Details) A.J.W. RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALEINDIANA DEPARTMENT OF TRANSPORTATION M.B. A.P. M.B. 4/2/2018 VERTICAL SCALE 1383180 1383180 R-36906 76ERR 1 S EF SPRONO. ASTATE OF D NIO IN LA AI N 01306 NGINE 27 EERIGEETS DANDREW J OHN W OLFDIRECTORY PATH: R:\Active\Carmel\Guilford Road Des. No. 1383180\CAD\PlansFILENAME: CONSTR-DETAILS.dwgDATE/USER: 7/20/2018 4:24 PM / ApercifieldCONSTRUCTION DETAIL LINE "B" 1"=10' N/AMATCH LINE 46+75 "B"31MATCH LINE 44+25 "B" 47+0048+0049+00AUBREY S. & JANIE D. NARAINE MAIN & GUILFORD PLAZA LLC (grass) (conc. walk) (conc. walk) (conc. walk) (grass) (grass) C.P. 170 N1°29'20"E(mulch/shrubs)(shrubs/mulch)12" Pipe12" Pipe1+002+00 Line "C" 12" San.6" San.6" SanApp. Exist. R/WApp. Exist. R/WConstr. Limits R/W R/W R/W R /WR/W Constr. Limits App. Exist. R/W 6'5'10'6'5'App. Exist. R/W 15 26 26 C2 26 26 K1 15 F 15 15 15 15 26 15 K1 16 18 26 26 F F K1 F App. Exist. R/WP.I. STA: 48+20.44 (No Curve) Sec. 25, T18N, R3E Clay Township Hamilton County MATT D. MITCHEL SHOTZIE LLC H H H H H H H H H P.O.T. 0+00.00 "C" = P.O.T. 9+58.00 "S-1-B" REMOVE INLET +19 "S-1-B" PL(50') Remove Inlet and Pipe W +02 "B" 49' +08 "B" PL(40') Line "B"Line "S-1-B"Line "B" Ap p . E x i s t . R / W App. Exist. R/WApp. Exist. R/W+34 "B" 47' +10 "B" 40' +43 "B" 60' +12 "B" 50' Temp R/W for Grading S. GUILFORD ROAD Str. No. 82, +92 "B" Inlet 'B-15' with 56' of 12" Pipe Str. No. 80, +92 "B" Inlet 'B-15' with 8' of 12" Pipe Str. No. 81, +80 "B" Inlet 'B-15' with 22' of 12" Pipe and 1 Pipe End Section Str. No. 83, +50 "B" Inlet 'C-15' with 139' of 12" Pipe Monument, C Monument, BW. MAIN ST.+22See Retaining Wall Detail Sheets for Additional Information 19 18 18 18 18 18 18 18 15 ADJUST SAN MH TO GRADE PROPOSED (See Typical Sheet for Additional Details) Concrete Curb (Barrier)14 Mill and OverlayR 15 Sodding26 16 Coniferous TreeMailbox Concrete Sidewalk, 4"F 18 Concrete Center Curb, Type 'D'19 Combined Concrete Curb & Gutter (Barrier) Modified Roll Curb Combined Concrete Curb & Gutter (Barrier) (Dry) Concrete Curb Ramp C2 PCCP, 7" with D-1 Contraction Joints Spaced at 14' Max. HMA for SidewalkP Asphalt ShoulderJ C PCCP, For Approaches 6" on Subgrade Treatment Type II. H C1 PCCP, For Approaches 9" on Subgrade Treatment Type II. Retaining WallW Full Depth Asphalt PavementK1 Removal (Pvmt, Sidewalk, Concrete) D HMA For Approaches (See Typical Sheet for Additional Details) A.J.W. RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALEINDIANA DEPARTMENT OF TRANSPORTATION M.B. A.P. M.B. 4/2/2018 VERTICAL SCALE 1383180 1383180 R-36906 76ERR 1 S EF SPRONO. ASTATE OF D NIO IN LA AI N 01306 NGINE 27 EERIGEETS DANDREW J OHN W OLFDIRECTORY PATH: R:\Active\Carmel\Guilford Road Des. No. 1383180\CAD\PlansFILENAME: CONSTR-DETAILS.dwgDATE/USER: 7/20/2018 4:24 PM / ApercifieldCONSTRUCTION DETAIL LINE "B" 1"=10' N/A MATCH LINE 49+25 "B"32MATCH LINE 46+75 "B"MATCH LINE 10+75 "S-1-B" MATCH LINE 9+00 "S-1-B" 50+0051+00MATT D. MITCHEL N. GUILFORD ROAD Line "B" SHOTZIE LLC +29,18'(conc)+21,32'(asph)+54,19'(asph)(conc. walk) (grass) (grass)(grass) STANLEY A. & ANGELA D. HUNNICUTT FRANK B. DIXON C.P. 175 Class I Drive W = 18' Conc. +48 (shrubs/mulch) 12" Pipe App. Exist. R/W App. Exist. R/W App PLApp PLConstr. Limits Constr. Limits Temp R/W for Drive Const. R/W Mod.Class III Drive W = 41' Asph. +21 15 15 K1 R C END PROJECT 50+39.01 "B" END INCIDENTAL CONSTRUCTION 50+63.54 "B" +64 "B" PL(30') +58.72 R/W +60.79 "B" 35' +38.85 "B" 51' +31.58 R/W App PLMonument, B +59F F F 15 14'8'29'7'+57R25'Sec. 25, T18N, R3E Clay Township Hamilton County ADJUST VALVE TO GRADE PROPOSED (See Typical Sheet for Additional Details) Concrete Curb (Barrier)14 Mill and OverlayR 15 Sodding26 16 Coniferous TreeMailbox Concrete Sidewalk, 4"F 18 Concrete Center Curb, Type 'D'19 Combined Concrete Curb & Gutter (Barrier) Modified Roll Curb Combined Concrete Curb & Gutter (Barrier) (Dry) Concrete Curb Ramp C2 PCCP, 7" with D-1 Contraction Joints Spaced at 14' Max. HMA for SidewalkP Asphalt ShoulderJ C PCCP, For Approaches 6" on Subgrade Treatment Type II. H C1 PCCP, For Approaches 9" on Subgrade Treatment Type II. Retaining WallW Full Depth Asphalt PavementK1 Removal (Pvmt, Sidewalk, Concrete) D HMA For Approaches (See Typical Sheet for Additional Details) A.J.W. RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALEINDIANA DEPARTMENT OF TRANSPORTATION M.B. A.P. M.B. 4/2/2018 VERTICAL SCALE 1383180 1383180 R-36906 76ERR 1 S EF SPRONO. ASTATE OF D NIO IN LA AI N 01306 NGINE 27 EERIGEETS DANDREW J OHN W OLFDIRECTORY PATH: R:\Active\Carmel\Guilford Road Des. No. 1383180\CAD\PlansFILENAME: CONSTR-DETAILS.dwgDATE/USER: 7/20/2018 4:24 PM / ApercifieldCONSTRUCTION DETAIL LINE "B" 1"=10' N/A 33MATCH LINE 49+25 "B"12'R 3 8 '27'26' Line "S-1-B" N88°49'50"E (conc. walk) (grass) (conc. walk) 12" Pipe 12" San. Constr. Limits Constr. Limits 10' 18 18 15 15 K2 F SHOTZIE LLC BEGIN CONSTRUCTION 6+83.34 "S-1-B" R1 BEGIN PROJECT 8+20.75 "S-1-B" Constr. Limits Constr. Limits App. Exist. R/W App. Exist. R/W App. Exist. R/W Line "S-1-B"Monument, B 10 Tons Revetment Riprap on 7 Sys. Geotextile, Type 1A 7 Tons Revetment Riprap on 5 Sys. Geotextile, Type 1A F F 15 19 Sec. 25, T18N, R3E Clay Township Hamilton County W. MAIN ST.+909'R26'R26'24'21'23'17'14'14'6'2'W. MAIN ST. N88°57'59"E App. Exist. R/W App. Exist. R/W App PLConstr. Limits R /W 18 18 26 15 K1 15 F F F Class I Drive W = 12' Conc. +49 AUBREY S. & JANIE D. NARAINE MATT D. MITCHEL H H H Constr. Limits END INCIDENTAL CONSTRUCTION 12+29.06 "S-1-B" END PROJECT 12+19.06 "S-1-B" Temp R/W for Drive Const. R/W +44 "S-1-B" PL(30') +44 "S-1-B" 40' +70 "S-1-B" 40' +70 "S-1-B" 32' +95 "S-1-B" PL(30') C +88 "S-1-B" 40' +12 "S-1-B" PL(30') +83 "S-1-B" 47' +97 "S-1-B" 42' +12 "S-1-B" 49' +12 "S-1-B" PL(42') W R/W Temp R/W for Grading R/W Line "S-1-B" Str. No. 84, +13 "S-1-B" Inlet Type 'C-15' Tie into Existing Pipe Monument, B+82R See Retaining Wall Detail Sheets for Additional Information +0519 Sec. 25, T18N, R3E Clay Township Hamilton County PROPOSED (See Typical Sheet for Additional Details) Concrete Curb (Barrier)14 Mill and OverlayR 15 Sodding26 16 Coniferous TreeMailbox Concrete Sidewalk, 4"F 18 Concrete Center Curb, Type 'D'19 Combined Concrete Curb & Gutter (Barrier) Modified Roll Curb Combined Concrete Curb & Gutter (Barrier) (Dry) Concrete Curb Ramp C2 PCCP, 7" with D-1 Contraction Joints Spaced at 14' Max. HMA for SidewalkP Asphalt ShoulderJ C PCCP, For Approaches 6" on Subgrade Treatment Type II. H C1 PCCP, For Approaches 9" on Subgrade Treatment Type II. Retaining WallW Full Depth Asphalt PavementK1 Removal (Pvmt, Sidewalk, Concrete) D HMA For Approaches (See Typical Sheet for Additional Details) A.J.W. RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALEINDIANA DEPARTMENT OF TRANSPORTATION M.B. A.P. M.B. 4/2/2018 VERTICAL SCALE 1383180 1383180 R-36906 76ERR 1 S EF SPRONO. ASTATE OF D NIO IN LA AI N 01306 NGINE 27 EERIGEETS DANDREW J OHN W OLFDIRECTORY PATH: R:\Active\Carmel\Guilford Road Des. No. 1383180\CAD\PlansFILENAME: CONSTR-DETAILS.dwgDATE/USER: 7/20/2018 4:24 PM / ApercifieldCONSTRUCTION DETAIL LINE "B" 1"=10' N/A MATCH LINE 9+00 "S-1-B"34MATCH LINE 10+75 "S-1-B"R20'R 1 0 '48' 126th STREETLine "B" GUILFORD ROAD 8'6' +34.17 "B" 843.32 +34.16 "B" 843.20 +28.14 "B" 842.92 +28.16 "B" 842.84 +20.78 "B" 842.79 +24.72 "B" 842.85 +13.87 "B" 842.62 +16.99 "B" 842.65 22 Ex. 842.17 +06.89 "B" 842.20 +51.15 "B" 843.15 +97.74 "B" 843.16 +97.95 "B" 843.45 +97.54 "B" 842.82 +97.34 "B" 842.69 1 . 5% 0.4% +39.60 "B" 843.181.5%2.9%2.0%1.8 %1.8% 2.0%6.7% 6.0%1.7%1.5%1.5%0.5% 0.0% 0.3% 23 24 +17.50 "B" 842.99 +14.03 "B" 843.00 +26.49 "B" 842.82 +08.01 "B" 843.06 +88.91 "B" 843.58 +88.14 "B" 843.47 +08.03 "B" 843.35 +14.03 "B" 842.85 Ex. 843.02 Ex. 843.0510'6' Line "B" GUILFORD ROAD WATERLILLIY WAYEx. 842.90 Ex. 843.11 +66.71 "B" 842.67 +74.68 "B" 842.80 +78.68 "B" 842.83 +69.72 "B" 842.69 existing asph. path existing conc. walk+03.01 "B" 843.57 +03.05 "B" 843.11 10'6' +29.41 "B" 842.80 +21.38 "B" 842.96 +48.07 "B" 843.51 +48.06 "B" 843.29 +48.06 "B" 843.09 +93.03 "B" 843.33 +61.04 "B" 842.46 +35.06 "B" 842.53 Ex. 842.34 Ex. 842.48 Ex. 842.302.0%1.2 % 1 . 2%1.2%8.3%1.5%0.6%8.3% 0.4%1.2%1.7%2.0%2.0%1.5% 1.6%2.3% 2.1% 1.0%1.0%1.0%1.5% 4.2%1.0% 1.0% +82.14 "B" 842.86 +82.11 "B" 842.810.1%12.4'12.4' 0.3%0.5% 0.3% 27 Ex. 840.61 Ex. 840.88 +70.20 "B" 840.17 +70.26 "B" 840.30 +77.57 "B" 840.10 +88.62 "B" 840.30+82.68 "B" 840.21 +73.73 "B" 840.07 +01.29 "B" 840.02 +01.33 "B" 840.07 +16.95 "B" 840.10 +24.96 "B" 840.04 +25.46 "B" 840.04 +21.20 "B" 840.08 +46.54 "B" 839.78 +47.87 "B" 839.68 5.6% 5.6%1.3%0.3%0.5%1. 1 %0.5% +28.39 "B" 840.00 +34.33 "B" 839.93 +34.30 "B" 839.89 +28.31 "B" 839.95 +53.30 "B" 840.30 +38.58 "B" 840.17 10'6'3.5' 0.8% 12.4' 6'5'0.9%0.7%1.2%1.2% 1.3%1.3%1.5% 7.12' +64.29 "B" 840.48 +64.34 "B" 840.63 2.2%2.2%+49.30 "B" 839.79 +91.30 "B" 840.62 +11.30 "B" 840.55 Ex. 840.97 Ex. 841.02Ex. 840.61 4.0%3.7%2.9%+01.30 "B" 840.20 +01.28 "B" 839.96 +01.31 "B" 840.44 +11.25 "B" 840.73 +91.33 "B" 840.75 2.9%3.2%2.0%0.5% 1.1%0.2% 0.1% +13.60 "B" 840.14 2.9%+85.68 "B" 840.23 1 . 0%CHIMNEY ROCKGUILFORD ROAD 1.7%0.5%0.5%0.7% A.J.W. RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALEINDIANA DEPARTMENT OF TRANSPORTATION M.B. A.P. M.B. 4/2/2018 VERTICAL SCALE 1383180 1383180 R-36906 76ERR 1 S EF SPRONO. ASTATE OF D NIO IN LA AI N 01306 NGINE 27 EERIGEETS DANDREW JOHN W O L FDIRECTORY PATH: R:\Active\Carmel\Guilford Road Des. No. 1383180\CAD\PlansFILENAME: SPOT ELEV DETAILS.dwgDATE/USER: 7/20/2018 4:11 PM / AwolfSPOT ELEVATION DETAILS 126th ST., WATERLILLY WAY,& CHIMNEY ROCK 35 1"=10' NA 28 29 30 +12.55 "B" 840.68 +54.62 "B" 841.50 +54.46 "B" 841.56 +53.97 "B" 841.63 +83.16 "B" 841.14 +51.87 "B" 841.59 +09.88 "B" 842.02 +09.72 "B" 842.07 +82.21 "B" 841.89 +82.03 "B" 842.02 Ex. 841.63 Ex. 842.22 Ex. 842.35 Ex. 842.04 Ex. 842.03 Ex. 842.14 +08.93 "B" 842.05 2.0%1.9%Ex. 842.56 Ex. 842.56 +11.70 "B" 842.07 +11.92 "B" 842.02 1.4%0.4% 0.2%1.6%1.5%+43.50 "B" 841.72 +40.04 "B" 841.83 +45.83 "B" 841.66 +45.81 "B" 841.62 +51.90 "B" 841.56 +51.84 "B" 841.508'6' 2.0% Ex. 842.36 Ex. 842.02 +51.76 "B" 842.02 +45.78 "B" 842.14 1.7%8.3%7.7%0.6%0.5%0.7%6'1.5% +51.39 "B" 842.09 Ex. 842.73 Ex. 842.78 Ex. 842.67 Ex. 842.89 8.0% 8.0%0.7%1.3%0.6%0.6% 6'8'GRAND BLVD.GUILFORD ROAD HELEN KEEN CT.Ex. 840.88Ex. 840.73 Ex. 841.59 Ex. 841.68 Ex. 841.64 Ex. 841.58 +98.34 "B" 841.24 +85.33 "B" 841.80+33.88 "B" 841.47 +20.90 "B" 841.12 +22.74 "B" 841.10 +56.38 "B" 841.50 +52.55 "B" 841.44 +34.26 "B" 841.37 +34.12 "B" 841.39 +98.25 "B" 841.83 +98.35 "B" 841.92 +07.90 "B" 841.41 +07.89 "B" 841.49 +17.93 "B" 841.12 +19.98 "B" 841.10 +13.95 "B" 841.18 +13.93 "B" 841.19 1.5% 1.5% 3.8% 4.8%4.4% 4.4%3.3%3.3%5'6' +21.01 "B" 841.49 6' 4' +23.95 "B" 840.96 +34.91 "B" 841.18 +45.83 "B" 841.111.5%0.9%0.4%0.5%0.5%0.4%2.2% 0.4%2.4% +55.69 "B" 841.46 +59.95 "B" 841.51 Ex. 840.89 Ex. 840.92 +73.05 "B" 841.64 +81.25 "B" 841.03 1.5%4 . 8% +63.43 "B" 841.40 +63.41 "B" 841.47 0.8% 1.5%1.5%2.5% +82.67 "B" 840.962.5%0.8%3.5'5'0.7%0.7% +48.49 "B" 841.24 +16.31 "B" 841.88 A.J.W. RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALEINDIANA DEPARTMENT OF TRANSPORTATION M.B. A.P. M.B. 4/2/2018 VERTICAL SCALE 1383180 1383180 R-36906 76ERR 1 S EF SPRONO. ASTATE OF D NIO IN LA AI N 01306 NGINE 27 EERIGEETS DANDREW JOHN W O L FDIRECTORY PATH: R:\Active\Carmel\Guilford Road Des. No. 1383180\CAD\PlansFILENAME: SPOT ELEV DETAILS.dwgDATE/USER: 7/20/2018 4:11 PM / AwolfSPOT ELEVATION DETAILS GRAND BLVD. & HELEN KEEN CT. 36 1"=10' NA 32 SCHOOL ENTRANCEGUILFORD ROAD COLLEGE WAY+62.99 "B" 842.93 +17.18 "B" 842.73 +71.37 "B" 841.91 Ex. 841.29Ex. 841.43 Ex. 841.29 +17.18 "B" 842.35 +17.18 "B" 842.26 +39.99 "B" 841.88 +36.18 "B" 841.79 +94.37 "B" 842.06 +98.19 "B" 841.96 +45.28 "B" 842.84 +07.28 "B" 842.82 +69.28 "B" 841.92 +40.01 "B" 842.59 +32.43 "B" 842.77 +82.07 "B" 843.29 +74.38 "B" 843.17 +07.28 "B" 842.81 +07.28 "B" 842.88 +27.28 "B" 843.01 +87.28 "B" 843.09 Ex. 841.62 Ex. 841.52 Ex. 841.58 Ex. 841.66 2.0%2.8%3.7%+17.18 "B" 841.91 1.3% 1.7% 2.2% 2.8% 2. 5 % 1 . 5%2.8%1.5%3.0%H.P.+52.81 "B" 842.03 +60.76 "B" 842.10 +61.01 "B" 842.03 +90.83 "B" 842.10 +95.07 "B" 841.99 0.0% 0.0% +88.49 "B" 842.00 1.5%+43.55 "B" 841.92 +39.30 "B" 841.82 +52.46 "B" 842.03 +52.47 "B" 842.10 1.2% 1.5%3.0% +45.86 "B" 841.92 1.3%1.5%6'5'2.9' 4' 7.2' 6'5'2.9' 4' Ex. 843.74 Ex. 843.90 Ex. 843.09 Ex. 842.93 +79.14 "B" 843.28 +70.65 "B" 843.14+67.49 "B" 843.20 +61.49 "B" 843.70 +61.59 "B" 843.70 +67.59 "B" 843.35 1.5%1.7%5.8% 8.3%2.0% 0.6%1.0%1.0%0.7%1 . 5% 2.0 % +35.41 "B" 842.75 +43.85 "B" 842.53 2.0% +47.11 "B" 842.60 +53.24 "B" 842.89 +53.11 "B" 843.04 +47.11 "B" 842.75 4.8%1.5%1.7%4.8% 0.0%2.0%Ex. 842.84 Ex. 842.97 Ex. 842.99 +07.26 "B" 843.06 Ex. 843.02Ex. 843.02 0.3% 0.4%1.8% 1.4%10'6' 11.5' 3.2' 6' 11.7' 3.2' 5'6' 1.4%0.4% 0.0% 0.1% +46.52 "B" 841.97 1.5%1.5%+81.90 "B" 842.03 34 +98.31 "B" 838.70 +08.31 "B" 838.51 +08.31 "B" 838.75+98.31 "B" 838.95 +98.31 "B" 839.05 +08.31 "B" 838.86 +08.31 "B" 838.75 +98.31 "B" 838.95 +08.31 "B" 838.51 +98.31 "B" 838.70 +08.31 "B" 837.97 +98.31 "B" 838.26 +08.31 "B" 838.30 +98.31 "B" 838.38 +08.31 "B" 838.10 +98.31 "B" 838.10 +98.31 "B" 838.02 +08.31 "B" 838.022.0%2.0%2.0%2.0%2.0%2.0%5.7%4.3%1.5%1.9% 1.9% Ex. 837.82Ex. 838.11 1.5%1.5%4.0%5'10'5.5'6'10'8.7'5.4'5.4'GUILFORD ROAD 0.0% 0.8% 1.9% 1.9% 36SCHOOL ENTRANCEGUILFORD ROAD Ex. 837.27 Ex. 837.33 Ex. 837.39 Ex. 837.39Ex. 837.44 +29.81 "B" 836.98 +57.72 "B" 836.49 +65.95 "B" 836.56 +62.91 "B" 836.55 +53.66 "B" 836.51 +81.75 "B" 836.88 +81.75 "B" 836.99 +97.61 "B" 836.90 +05.93 "B" 836.71 +10.04 "B" 836.74 +00.66 "B" 836.88 +33.41 "B" 836.60 +91.65 "B" 837.24 +71.82 "B" 837.04 +81.75 "B" 836.77 2.0%1.1%1.1%1.1%Ex. 837.85 +69.23 "B" 837.50 +46.25 "B" L.P. 836.42 3.8% +50.19 "B" 836.48 +50.22 "B" 836.33 1.5%3.8%2.2%0.5% 3.5% 2.7% 1.8% 0.6% 0.6%1.5% 0. 3 % 1 . 5% 7.9% 0.5% +13.58 "B" 836.94 3.0% 0.3% 7.2'10'6' 3.6' 13'6'12.7'10'0.3%0.3% +65.80 "B" 837.13 1.5%1.5%+13.58 "B" 836.791.5%Ex. Inlet El. =835.47 +29.74 "B" 837.441.5%+44.20 "B" 836.10 +44.17 "B" 836.25 1.5%1.5%+19.56 "B" 837.27 +19.63 "B" 837.12 A.J.W. RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALEINDIANA DEPARTMENT OF TRANSPORTATION M.B. A.P. M.B. 4/2/2018 VERTICAL SCALE 1383180 1383180 R-36906 76ERR 1 S EF SPRONO. ASTATE OF D NIO IN LA AI N 01306 NGINE 27 EERIGEETS DANDREW JOHN W O L FDIRECTORY PATH: R:\Active\Carmel\Guilford Road Des. No. 1383180\CAD\PlansFILENAME: SPOT ELEV DETAILS.dwgDATE/USER: 7/20/2018 4:11 PM / AwolfSPOT ELEVATION DETAILS COLLEGE WAY - S. SCHOOL ENT. MID SCHOOL ENT., & CROSSWALK 37 1"=10' NA 38 39 +11.11 "B" 836.02 +45.99 "B" 836.46+34.32 "B" 836.60 +34.36 "B" 836.75 +50.91 "B" 836.63 +42.91 "B" 836.44 +48.13 "B" 836.62 +84.32 "B" 836.68 +84.30 "B" 836.51 Ex. 837.97 Ex. 837.86 Ex. 837.72 1.1%1.5%+40.36 "B" 836.49 1.8% +39.61 "B" 836.73 2.9%1.4%2.2%2.0%1.5%2.9%3.0%+69.12 "B" 836.27 +69.09 "B" 836.11 +92.22 "B" 836.48 +01.68 "B" 836.26 +27.16 "B" 835.48 Ex. 837.41 +53.16 "B" 837.23 +84.94 "B" 837.40 +69.13 "B" 835.73 Ex. 837.92 1.5%1.2%2.0%+30.35 "B" 836.18 +30.31 "B" 836.031.5%3.0%1 . 5% 3.0 % +95.45 "B" 836.45 +06.11 "B" 836.16 +10.35 "B" 836.08 2.0%0.3%0.3% +16.36 "B" 836.06 +16.40 "B" 836.21 +10.40 "B" 836.23 0.3%1.5%0.3%10'6'14.9'6'7.8'10'3.2' 8' 4.1' 2.0%0.9% 1.5%0.2% 0.4% 0.4% +08.81 "B" 836.02 +40.19 "B" 835.31 +44.01 "B" 835.22 +50.81 "B" 834.80 +76.64 "B" 834.69 +83.44 "B" 835.05 +87.26 "B" 835.14 +18.64 "B" 835.69 +63.72 "B" 835.84 +63.72 "B" 835.57 +63.72 "B" 835.49 Ex. 835.14 Ex. 835.10 Ex. 834.52 Ex. 834.75 Ex. 834.45 Ex. 834.65 Ex. 834.612.0%2.0%1.5%1.9%2.0 % 1 . 5%1.7% +09.07 "B" 835.69 +08.46 "B" 835.61 +27.72 "B" 835.46 +27.72 "B" 835.38 +33.72 "B" 835.40 +33.72 "B" 835.32 +36.64 "B" 835.36 +40.88 "B" 835.24 +38.39 "B" 835.27 1.1% 1.1%1.5%0.7%+63.74 "B" 834.94 1.2%2.0% 1.5% 2.5% 1.5%1.5%1.5%+99.73 "B" 835.18 +99.73 "B" 835.10 +93.73 "B" 835.16+86.58 "B" 835.08 +90.84 "B" 835.18 1.5%1.0% 0.0% 1.1% 6' 7.2'5'2.9'6'5'2.9' 4' 7.2' GUILFORD ROADSCHOOL ENTRANCEEMERSON RD0.3%0.3% +49.80 "B" 837.12+41.95 "B" 837.24 1.5%1.5%A.J.W. RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALEINDIANA DEPARTMENT OF TRANSPORTATION M.B. A.P. M.B. 4/2/2018 VERTICAL SCALE 1383180 1383180 R-36906 76ERR 1 S EF SPRONO. ASTATE OF D NIO IN LA AI N 01306 NGINE 27 EERIGEETS DANDREW JOHN W O L FDIRECTORY PATH: R:\Active\Carmel\Guilford Road Des. No. 1383180\CAD\PlansFILENAME: SPOT ELEV DETAILS.dwgDATE/USER: 7/20/2018 4:11 PM / AwolfSPOT ELEVATION DETAILS COLLEGE WAY & SOUTH SCHOOL ENTRANCE 38 1"=10' NA 43 +68.68 "B" 840.61 +25.26 "B" 842.15 +81.83 "B" 843.70 +50.46 "B" 842.21 +46.64 "B" 842.10 +39.83 "B" 841.13 +10.46 "B" 840.89 +06.37 "B" H.P. 841.25 +00.06 "B" 841.09 +25.26 "B" 841.67 +25.26 "B" 841.58 +96.49 "B" 841.06+87.60 "B" 840.58 +93.60 "B" 841.08 +87.60 "B" 840.65 +93.60 "B" 841.15 +00.67 "B" 841.15 +49.84 "B" 842.13 +56.92 "B" 842.26 +62.92 "B" 842.41 +62.92 "B" 842.49 +56.92 "B" 842.35+54.05 "B" 842.31+68.68 "B" 839.77 +68.68 "B" 839.81 1.5%1.0%8.3% 8.3% 0.0% 0.7% 1.4 % 1 . 4%2.4%+03.88 "B" 841.18 Ex. 840.41 Ex. 841.06 Ex. 840.89 2.7%2.7% 1.9% 1.5% 2.8% 2.5%2.0%3.5%1.5%3.3%4.2%1.5%4.0%1.4% 1.8% 2.4% 2.4%1.5%6' 7.2'5'2.9'6'5'2.9' 7.2' GUILFORD ROAD DRUID HILL DR.45 Ex. 847.03 Ex. 847.20 Ex. 847.61 +77.35 "B" 846.60 +98.40 "B" 847.45 +18.35 "B" 847.43+57.35 "B" 845.76 +54.97 "B" 846.66 +54.97 "B" 846.81 +60.97 "B" 846.63 +60.97 "B" 846.78 +74.68 "B" 846.79 +70.41 "B" 846.44 +73.78 "B" 846.43 +01.99 "B" 847.35+05.20 "B" 847.30 +13.99 "B" 847.80 +13.99 "B" 847.95 +07.99 "B" 847.45 +00.99 "B" 847.45 +87.82 "B" 846.80 +87.82 "B" 846.97 +87.82 "B" 846.59 +07.99 "B" 847.30 2.7%2.7%2.0%2.6%1.5%2.7%1.2%3.5% 2.1%0.9%0.9% +09.96 "B" L.P. 847.25 8.3% 8.3%1.5%0.0%4.6%3.9% 3.7%2.8%1.5%1.5%0.6% 0.6%2.0% 0.0% +74.72 "B" 847.49 +70.68 "B" 847.55 1.5% 6' 13.7'10'9.5' 6'10'7' 2.8' GUILFORD ROADGUILFORD TRAIL DR.+74.73 "B" 847.18 46GUILFORD ROAD WILSON TERRACE+53.75 "B" 848.38 +67.57 "B" 848.33 +73.57 "B" 848.50 +76.08 "B" 848.55 +78.90 "B" 848.49 +83.75 "B" 847.78 +94.20 "B" 849.19 +94.20 "B" 848.93 +94.20 "B" 848.85 +94.20 "B" 847.99 +05.10 "B" 848.40 +04.66 "B" 848.68 +06.71 "B" 849.19 +09.23 "B" 849.28 +24.75 "B" 849.49 +81.70 "B" 848.47 +67.57 "B" 848.24+73.57 "B" 848.42 +09.51 "B" 849.22 +12.33 "B" 849.30 +14.89 "B" 849.27 +15.08 "B" 849.35 +21.08 "B" 849.78 +20.99 "B" 849.70 +79.18 "B" 848.56 +83.43 "B" 847.42 Ex. 847.76Ex. 846.78 Ex. 847.37 Ex. 849.27 Ex. 849.19 0. 6%1.5%6.3%2.0%1.5%6.1%2.0%3.1%1.1% 2.8%2.0%1.5%3.0%2.3% 2.2%2.4%7.2% 1.7% 7.2% 0.8%1.5%1.5%6'5'5'4' 2.5' 5.3' 6'2.7' 2.0%1.4%2.0%+80.72 "B" 848.59 Ex. 847.20 Ex. 847.52 A.J.W. RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALEINDIANA DEPARTMENT OF TRANSPORTATION M.B. A.P. M.B. 4/2/2018 VERTICAL SCALE 1383180 1383180 R-36906 76ERR 1 S EF SPRONO. ASTATE OF D NIO IN LA AI N 01306 NGINE 27 EERIGEETS DANDREW JOHN W O L FDIRECTORY PATH: R:\Active\Carmel\Guilford Road Des. No. 1383180\CAD\PlansFILENAME: SPOT ELEV DETAILS.dwgDATE/USER: 7/20/2018 4:11 PM / AwolfSPOT ELEVATION DETAILS DRUID HILL,GUILFORD TR.,& WILSON TERRACE 39 1"=10' NA 9Line "S-1-B" Ex. 849.54 Ex. 849.59 Ex. 849.77 Ex. 849.73 Ex. 849.94 Ex. 849.94 Ex. 848.44 Ex. 848.37 +04.46 "S-1-B" 849.51 +99.79 "S-1-B" 849.13 +08.62 "S-1-B" 849.271.5%1.4 % 8.2 % +11.09 "S-1-B" 848.77 +01.81 "S-1-B" 848.63 +02.89 "S-1-B" 848.63 +12.16 "S-1-B" 848.77 +19.46 "S-1-B" 849.12 +09.79 "S-1-B" 848.98 2.0 % 2.0 %1.4%0.4 %1.4%+05.46 "S-1-B" 848.28 +04.77 "S-1-B" 848.28 +14.37 "S-1-B" 848.41 +15.06 "S-1-B" 848.41 +20.72 "S-1-B" 848.83 +21.43 "S-1-B" 848.84 +11.26 "S-1-B" 848.69+10.55 "S-1-B" 848.68 +03.16 "S-1-B" 848.40 +12.76 "S-1-B" 848.53 +15.96 "S-1-B" 848.46 2.1% 2.0%1.3%1.5%+20.53 "S-1-B" 849.12 +10.87 "S-1-B" 848.98 10'6' 4.4' 3.0% 5.3% 5' 2.8' 2.7' 6'10' 5' 10' 4.1' 2.0% 2.0% 1.5%Edge Existing WalkEdge Existing Building1.3%1.4%8.2 % 49 Line "B" +08.43 "B" 849.50 +17.80 "B" 849.57 +10.70 "B" 849.60 +19.61 "B" 849.69 +05.39 "B" 850.06 +03.11 "B" 849.99 +07.33 "B" 849.50 +16.81 "B" 849.56 +10.60 "B" 849.87 +09.64 "B" 849.87 +01.03 "B" 849.83 +99.93 "B" 849.83 +98.94 "B" 849.91 +99.42 "B" 849.91 +08.90 "B" 849.94 +09.29 "B" 849.94 +13.00 "B" 849.72 +13.48 "B" 849.72 +03.42 "B" 849.69 +03.93 "B" 849.69 +04.98 "B" 850.27 +14.51 "B" 850.21 +16.27 "B" 850.30+06.77 "B" 850.36 Ex. 849.57 Ex. 849.56 1.5%1.8%0.6 % 0.4% 0.3% 0.3%1.1%1.0%1.9%2.0%8.2%8.2%1.5%1.6%4.5% 10.1' 10' 10.1'6'8.5'5'6'1.6%2.3%2.8% 10'6'4.4'2.6'4.7'4.8'0.8%1.0%0.6% 0.9 %11+82.91 "S-1-B" 849.03 +82.07 "S-1-B" 848.53 +81.67 "S-1-B" 848.52 +91.45 "S-1-B" 848.31+91.69 "S-1-B" 848.35 +92.52 "S-1-B" 848.84 +93.63 "S-1-B" 848.93 +84.39 "S-1-B" 849.13 +78.11 "S-1-B" 848.81 +77.81 "S-1-B" 848.81 +88.21 "S-1-B" 848.60 +87.76 "S-1-B" 848.61 +78.82 "S-1-B" 848.73 +79.65 "S-1-B" 848.73 +88.38 "S-1-B" 848.57 +89.21 "S-1-B" 848.57 +94.69 "S-1-B" 848.19 +95.49 "S-1-B" 848.19 +97.51 "S-1-B" 848.68 +85.16 "S-1-B" 848.40 +86.04 "S-1-B" 848.40 +88.11 "S-1-B" 848.89 8.3% 8.3% 1.5%2.0%2.0%1.4% 1.2%1.6%2.1% 2.4%2.0%8.3% 8.1% 1.5%10.1'10'6' 2.9' 2.6' 4.9'4.9' 0.8% 0.1%10'10'5'2.0%2.0%47 +22.03 "B" 849.99 +20.66 "B" 850.48 +30.38 "B" 850.53 +31.74 "B" 850.03 +32.33 "B" 850.03 +22.61 "B" 849.98 +38.69 "B" 850.52+29.29 "B" 850.46 +28.17 "B" 850.46 +38.05 "B" 850.51 +39.40 "B" 850.39 +29.88 "B" 850.37 +29.46 "B" 850.31 +39.43 "B" 850.33 +23.14 "B" 849.97 +32.90 "B" 849.94 +22.38 "B" 849.97 +32.16 "B" 849.94 +20.14 "B" 850.44 +30.46 "B" 850.43 +19.52 "B" 850.56 +29.24 "B" 850.61 +38.66 "B" 850.33 +28.49 "B" 850.30 1.5%1.5%8.3%8.3%1.9%1.9%0.5%7.2'10.2'5.2'10'2.9%2.5%10'5'6'7.7'6.1%6'8.3%Edge Existing Walk Edge Existing Building Ex. 850.42 0.4%1.9%1.8%Line "B" 0.2% 0.5% 0.5% A.J.W. RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALEINDIANA DEPARTMENT OF TRANSPORTATION M.B. A.P. M.B. 4/2/2018 VERTICAL SCALE 1383180 1383180 R-36906 76ERR 1 S EF SPRONO. ASTATE OF D NIO IN LA AI N 01306 NGINE 27 EERIGEETS DANDREW JOHN W O L FDIRECTORY PATH: R:\Active\Carmel\Guilford Road Des. No. 1383180\CAD\PlansFILENAME: SPOT ELEV DETAILS.dwgDATE/USER: 7/20/2018 4:11 PM / AwolfSPOT ELEVATION DETAILS SPLITTER ISLAND RAMPS 40 1"=10' NA SOUTH ISLAND NORTH ISLAND EAST ISLANDWEST ISLAND N. GUILFORD ROADLine "B"WILSON TERRACE CT. W. MAIN ST. Line "S-1-B" W. MAIN ST. Line "S-1-B" Line "C" BEGIN PROJECT 8+20.67 "S-1-B" END PROJECT 12+19.06 "S-1-B" P.O.T. 48+20.44 "B" = P.O.T. 10+00.00 "S-1-B" P.O.T. 0+00.00 "C" = P.O.T. 9+58.00 "S-1-B" END PROJECT 50+39.01 "B" 46+00 47+00 49+00 50+00 -0+00 1 + 0 02+00P.I. +27 "S-1-B" 22.50' Lt. P.C. +82.84 "S-1-B" 22.50' Lt. P.C.C. +49.47 "S-1-B" 43.10' Lt. P.O.T. +05.25 "S-1-B" 20.27' Rt. P.O.T. +20.67 "S-1-B" 23.55' Lt. P.O.T. +20.67 "S-1-B" 17.09' Rt. P.C. +62.22 "S-1-B" 8.50' Rt. P.T. +22.29 "S-1-B" 24.50' Rt. P.C. +36.42 "S-1-B" 32.63' Rt. P.C.C. +75.24 "S-1-B" 24.70' Lt. P.T. +40.01 "S-1-B" 11.00' Lt.P.O.T. +19.06 "S-1-B" 11.00' Lt. P.O.T. +19.06 "S-1-B" 11.00' Rt. P.T. +06.59 "S-1-B" 11.00' Rt. P.C.C. +64.09 "S-1-B" 37.24' Rt. P.O.T. +90.24 "S-1-B" 8.20' Lt. P.O.T. +36.16 "S-1-B" 11.63' Lt. P.O.C. +34.39 "S-1-B" 10.00' Rt. P.C. +90.01 "S-1-B" 2.42' Lt. P.O.T. +64.09 "S-1-B" 8.91' Rt. P.O.T. +09.86 "S-1-B" 5.73' Rt. P.O.C. +10.08 "S-1-B" 0.07' Lt.P.O.C. +65.30 "S-1-B" 12.50' Lt. P.T. +13.71 "S-1-B" 0.00' P.C. +78.10 "S-1-B" 0.99' Rt. P.T. +06.59 "S-1-B" 0.00' +24.75 "B" 19.68' Rt. P.I. +66.62 "B" 27.47' Rt. P.C. +89.55 "B" 25.64' Rt. P.C.C. +75.87 "B" 53.01' Rt. P.O.T. +68.18 "B" 5.28' Rt. P.C. +04.82 "B" 2.35' Rt. P.O.C. +55.23 "B" 11.48' Rt.P.O.T. +56.51 "B" 7.00' Lt. P.I. +96.65 "B" 7.00' Lt. P.O.T. +67.29 "B" 1.13' Lt. P.C. +47.71 "B" 18.00' Lt. P.C.C. +39.97 "B" 28.01' Lt. P.T. +73.69 "B" 38.92' Lt. P.C. +94.55 "B" 27.21' Lt. P.T. +56.38 "B" 11.90' Lt. P.I. +84.45 "B" 26.48' Lt. P.O.T. +89.52 "B" 29.72' Lt. P.C.C. +86.02 "B" 36.94' Rt. P.T. +33.22 "B" 8.12' Rt. P.T. +39.21 "B" 7.96' Rt. P.O.T. +84.52 "B" 10.14' Rt. P.O.C. +85.78 "B" 11.57' Lt. P.O.T. +24.80 "B" 6.31' Rt. P.O.C. +25.64 "B" 0.49' Lt. P.C. +01.20 "B" 0.96' Lt. P.T. +34.99 "B" 0.34' Lt. P.T. +32.93 "B" 2.88' Lt. P.O.T. +56.85 "B" 11.91' Lt. R 3 0 'R400'R100'R100'R160'R400'R411'R65'R450' R12 0 'R10 0 ' R461' R430' R120' R100'R3 0 ' R 3 2 ' R60' (TYP)R120'R70' P.T. +29.02 "S-1-B" 3.64' L R411'R42'15.28'17. 9 3 '18.6'25.0 7 ' A.J.W. RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALEINDIANA DEPARTMENT OF TRANSPORTATION M.B. A.P. M.B. 4/2/2018 VERTICAL SCALE 1383180 1383180 R-36906 76ERR 1 S EF SPRONO. ASTATE OF D NIO IN LA AI N 01306 NGINE 27 EERIGEETS DANDREW J OHN W OLFDIRECTORY PATH: R:\Active\Carmel\Guilford Road Des. No. 1383180\CAD\PlansFILENAME: GEOMETRIC.dwgDATE/USER: 7/20/2018 4:09 PM / ApercifieldROUNDABOUT GEOMETRIC DETAILS 1"=30' 41 46+00 47+00 49+00 50+00 S. GUILFORD ROADN. GUILFORD ROADLine "B" & Section LineWILSON TERRACE CT. W. MAIN ST. Line "S-1-B" P.I. STA: 48+20.44 (No Curve) 1 + 0 02+00Line "C" W. MAIN ST.8+007+009+0010+0011+0012+000+00 Line "B""E ENT" 840 845 850 855 840 845 850 855 11+00 11+25 "E EXIT" 840 845 850 855 840 845 850 855 11+00 12+00 12+25 "W ENT" 840 845 850 855 840 845 850 855 9+00 9+50 BEGIN 7+98.46 "W EXIT" =7+98.46 "S-1-B", 2.50 Lt. END 9+36.48 "W EXIT" =9+36.16 "S-1-B", 11.63 Lt. BEGIN 8+85.98 "W ENT" =8+85.98 "S-1-B", 2.50 Lt. END 9+36.52 "W ENT" =9+34.39 "S-1-B", 10.00 Rt. BEGIN 10+63.18 "E ENT" =10+65.30 "S-1-B", 12.50 Lt. END 11+13.71 "E ENT" =11+13.71 "S-1-B" BEGIN 10+63.79 "E EXIT" =10+64.09 "S-1-B", 8.91 Rt. END 12+06.59 "E EXIT" =12+06.59 "S-1-B" BEGIN 48+83.92 "N EXIT" =48+84.52 "B", 10.14 Rt. END 50+32.92 "N EXIT" =50+32.92 "N ENT" "N EXIT" 845 850 855 845 850 855 49+00 50+00 50+50 BEGIN 48+83.92 "N ENT" =48+85.78 "B", 11.57 Lt. END 50+63.44 "N ENT" =50+63.44 "B", 3.67 Lt. BEGIN 46+68.18 "S ENT" =46+68.18 "B", 5.28 Rt. END 47+56.74 "S ENT" =47+55.23 "B", 11.48 Rt. "S ENT" 845 850 855 845 850 855 47+00 47+75 BEGIN 46+67.28 "S EXIT" =46+67.29 "B", 1.13 Lt. END 47+57.09 "S EXIT" =47+56.51 "B", 7.00 Lt. "N ENT" 845 850 855 845 850 855 49+00 50+00 50+75850.10850.20850.28850.40850.51850.61850.77849.83849.92850.02850.11850.21850.51850.77 Sta:48+83.93Elev:849.77 Sta:50+01.15Elev:850.21 Sta:50+63.44Elev:850.87+0.72% +0.38%+1.28%850.18849.06847.63846.28845.13844.12848.87848.12847.12846.12845.12844.12 Sta:10+63.79Elev:849.09 Sta:10+87.88Elev:848.61 Sta:12+06.59Elev:843.86-2.00% -4.00%Line "S ENT"Line "S EXIT"Line "W EXIT" Line "W ENT"Line "E EXIT" Line "E ENT"Line "N EXIT"Line "N ENT"850.18849.13848.79848.13 Sta:10+63.17Elev:848.98 Sta:10+89.03Elev:848.57 Sta:11+13.71Elev:847.58-1.62%-4.00%849.99850.01850.19850.29850.45850.60849.91849.98850.06850.13850.21850.52 Sta:48+83.93Elev:849.86 Sta:50+01.12Elev:850.21 Sta:50+32.93Elev:850.62+1.28%+0.30% "W EXIT" 840 845 850 855 840 845 850 855 8+00 9+00 9+50847.46847.80848.04848.29848.64849.02847.45847.70847.94848.19848.52848.90 Sta:7+98.46Elev:847.44 Sta:8+84.11Elev:848.28 Sta:9+36.48Elev:849.07+1.51% +0.98% "S EXIT" 845 850 855 845 850 855 47+00 47+75848.83848.93848.84849.19 Sta:8+85.98Elev:848.64 Sta:9+36.51Elev:849.35+1.40%850.76850.57850.51850.00850.17850.23850.29850.36 Sta:46+67.34Elev:850.15 Sta:47+57.09Elev:850.37+0.25%850.76850.79850.58850.34850.18850.31850.44850.57 Sta:46+68.18Elev:850.15 Sta:47+56.74Elev:850.60+0.51% Exist. Grade Proposed Grade Exist. Grade Proposed Grade Exist. Grade Proposed Grade Proposed Grade Exist. Grade Proposed Grade Exist. Grade Proposed Grade Exist. Grade Proposed Grade Exist. Grade Proposed Grade Exist. Grade 0.8%2.1%1.6%1.1%1.9%1.9%1.4%1.9%0.9% 2.0 % 2.0 %2.0%0.50%0.51%0.25%0.35%2.00% 2.00% 1.62 % 2.00 %0.30%0.38%0.63%0.30%1.27% 1.51% 1.40 % 1.41 % 849.07 849.35 849.20 850.60850.37 849.09 848.98 849.86849.77 849.04 849.82 850.48 "C" 845 850 855 845 850 855 0+00 1+00 2+00 2+75849.35849.93850.50850.60849.88849.43849.41849.81850.03849.34849.14 Sta:0+00Elev:849.35 Sta:2+63.89Elev:849.35-3.55% -2.89% +2.30%+2.24%+2.30%Proposed Grade PVI STA: 0+65.75 PVI ELEV: 850.87 VCL: 20.00 PVI STA: 1+96.23 PVI ELEV: 850.28 VCL: 30.00 PVI STA: 1+34.12 PVI ELEV: 848.89 VCL: 75.00 PVI STA: 2+38.80 PVI ELEV: 848.77 VCL: 50.00 849.65 846.74 847.51 849.88 850.07 0.9%3.9% 847.19 849.41 849.82 849.41 1.1% 846.30 850.10 848.20 848.68 849.66 1. 7% 4.1% 849.49 843.64 848.32 848.70 850.10 4.0%2.3%+39.2 "B" 8.0' +93.2 "B" 34.3' +72.1 "S-1-B" 26.2' +40 "S-1-B" 11.0' +06.6 "S-1-B" 11.0'+91.3 "S-1-B" 28.0' +73 "S-1-B" 34.0' +94.7 "S-1-B" 17.5' +24.8 "B" 19.7' +45.5 "B" 34.6' +47.7 "B" 18.0' +95.1 "B" 20.6' +48.3 "B" 30.4' +05.3 "S-1-B" 20.3' +25 "S-1-B" 16.2' +20.7 "S-1-B" 23.6' +94.6 "B" 27.2' +56.9 "B" 11.9' +89.5 "B" 29.7' A.J.W. RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALEINDIANA DEPARTMENT OF TRANSPORTATION M.B. A.P. M.B. 4/2/2018 VERTICAL SCALE 1383180 1383180 R-36906 76ERR 1 S EF SPRONO. ASTATE OF D NIO IN LA AI N 01306 NGINE 27 EERIGEETS DANDREW J OHN W OLFDIRECTORY PATH: R:\Active\Carmel\Guilford Road Des. No. 1383180\CAD\PlansFILENAME: PROFILES & SPOT ELEV.dwgDATE/USER: 7/20/2018 4:09 PM / AwolfPROFILES & SPOT ELEVATIONS 1"=30' 1"=5' 42 45+0046+0047+0048+0049+0050+0051+00P.I. STA: 48+20.44 (No Curve)1+002+00S. GUILFORD ROAD N. GUILFORD ROAD WILSON TERRACE CT.W. MAIN ST.GUILFORD TRAIL DR.847 84 8 8498508 5 0 84 3 844 845 846 847 848 849 850 849 848 847 846 845 845846847 850 850 851 850850 849848 847846845 845 846 847 849 848847A.J.W. RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALEINDIANA DEPARTMENT OF TRANSPORTATION M.B. A.P. M.B. 4/2/2018 VERTICAL SCALE 1383180 1383180 R-36906 76ERR 1 S EF SPRONO. ASTATE OF D NIO IN LA AI N 01306 NGINE 27 EERIGEETS DANDREW JOHN W O L FDIRECTORY PATH: R:\Active\Carmel\Guilford Road Des. No. 1383180\CAD\PlansFILENAME: CONTOURS.dwgDATE/USER: 7/20/2018 4:09 PM / Apercifield43 1"=20' 1"=5' ROUNDABOUT EXISTING CONTOURS 45+0046+0047+0048+0049+0050+0051+00P.I. STA: 48+20.44 (No Curve)1+002+00S. GUILFORD ROAD N. GUILFORD ROAD WILSON TERRACE CT.W. MAIN ST.GUILFORD TRAIL DR.850850 850 850 850 850 851 851845 850 844 846 847 848 849 851 852 850848849 851 850850851 851851 851852852 A.J.W. RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALEINDIANA DEPARTMENT OF TRANSPORTATION M.B. A.P. M.B. 4/2/2018 VERTICAL SCALE 1383180 1383180 R-36906 76ERR 1 S EF SPRONO. ASTATE OF D NIO IN LA AI N 01306 NGINE 27 EERIGEETS DANDREW JOHN W O L FDIRECTORY PATH: R:\Active\Carmel\Guilford Road Des. No. 1383180\CAD\PlansFILENAME: CONTOURS.dwgDATE/USER: 7/20/2018 4:09 PM / Apercifield44 1"=20' 1"=5' ROUNDABOUT PROPOSED CONTOURS 40+0039+5024°S. GU ILFORD ROADLine "B "App. Ex is t . R/W SECTION LINE Existin g C ul v e r t ( R e m o v e ) Varies (3:1 M a x ) Varies (4:1 M a x ) 103 Lft. 16' x 6' R.C. Box Culvert 16.0' 19.6' 11.3' 65° 22.0' 12.0' 61° 48.2'47.1' 550 +PL/R W 551 +PL/P L 568 +PL/R W 1+00 2+ 0 0 2+14 0+50 1+ 5 0 55.9' 820 825 830 835 840 845 820 825 830 835 840 845 INLET OUTLET LINE "B"P.G.=836.06<<<<<<<<<<<<<<<Flowline828.28 827.56 826.78 826.06 Flowline 4.5'1.5' Sump Class I Riprap on GeotextilesClass I Riprap on Geotextiles B Flowline = 828.28 Invert = 826.78 16.0' 6.0' 3.6' Elev. = 836.5Elev. = 836.5 Elev. = 836.5 Elev. = 835.59 A Min. Structure Elev. = 832.78 Q100 Elev. = 832.52 D Flowline = 827.56 Invert = 826.06 16.0' 6.0' 4.4' Elev. = 836.5 Elev. = 833.0 Elev. = 836.5 Elev. = 833.0 C Min. Structure Elev. = 832.06 Cutout to accommodate Storm Pipe Outlet Invert = 831.22 Cutout to accommodate Storm Pipe Outlet Invert = 828.39 A.J.W. RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALEINDIANA DEPARTMENT OF TRANSPORTATION M.B. A.P. M.B. 4/2/2018 VERTICAL SCALE 1383180 1383180 R-36906 76ERR 1 S EF SPRONO. ASTATE OF D NIO IN LA AI N 01306 NGINE 27 EERIGEETS DANDREW J OHN W O L FDIRECTORY PATH: R:\Active\Carmel\Guilford Road Des. No. 1383180\CAD\PlansFILENAME: CULVERT.dwgDATE/USER: 7/20/2018 4:08 PM / AwolfCULVERT DETAILS AS NOTED 45 SECTION Scale: 1"=10'-0" PLAN Scale: 1"=10'-0" 16'-0" OPENING x 6'-0" RISE 24 DEGREE SKEW ON GUILFORD ROAD AT LITTLE COOL CREEK PRECAST REINFORCED CONCRETE FOUR-SIDED CULVERT HYDRAULIC DATA 197 acres 514.54 cfs 0.941 ft 7.86 fps 0 ft DRAINAGE AREA Q100 PROPOSED BACKWATER Q100 VELOCITY ROADWAY OVERFLOW WATERWAY AREA Live Load Dead Load DESIGN DATA 4 1 18"18" Structure Backfill, Type 2 1 1 * *18" *Proposed Ground Line Varies*Dimensions to be determined by Unit Manufacturer STRUCTURE BACKFILL, TYPE 2 CULVERT CROSS SECTION No Scale WINGWALL SECTION No Scale 0'-6"ELEVATION - EAST WALL - DOWNSTREAM END Scale: 1/4"=1'-0" ELEVATION - WEST WALL - UPSTREAM END Scale: 1/4"=1'-0" WINGWALL AREAS (SFT.) 238A B C D 116 240 133 Designed for self-weight plus 35 psf for future wearing surface. The Structure shall be designed for HL-93 loading in accordance with AASHTO LRFD Bridge Design Specifications, 6th Edition, and all subsequent interim specifications.Clear ZoneClear ZoneSee Handrail Detail GEOTECHNICAL DATA 49+00.0048+50.0001 WEST MAIN STREETGUILFORD ROADProposed Retaining Wall +22 "B"+05 "S-1-B"BB A A BB840 845 850 855 840 845 850 855 0+00 1+00 1+60850.13851.82853.29852.48850.16848.32846.79850.14850.29851.41850.21848.95848.04846.87+22 "B"+05 "S-1-B"Existing Ground at Face of Wall Sidewalk Grade at Face of Wall Section "B-B"Section "A-A"Section "B-B" 2"~ PVC Drain SECTION "A-A" Scale: 3/4"=1'-0" 5'-9" 4 Spa.@ 1'-2\" = 4'-10" 1\"x3\" Keyway 4" Cl.6'-6" Minimum, 7'-6" Maximum#4 Horiz. Reinforcing 10"1'-0" 24" Square of Geotextile for Underdrain at Inlet. Sidewalk Structure Backfill Type 3 5 Spa.@ 12"=5'-0"3"1'-0"Elev.851.25 North Break 3"Spacing Varies#4 Bars Top & Botm. 3" Cl.1'-0"Elev.851.44 Max.1'-6"Min. #4 Lap501 @ 9" 401 @ 12" Affix to Wall. Elev.849.69 South Break 3'-11" #4x5'-3"@9" 5\"5\" #4 Longitudinal Spacing Top & Bottom #4x6'-2" @ 12" Front Face 503 @ 12" Rear Face 10" Stem Up to 2" for Ashlar Stone Face Form 2'-6[" Min. 3'-9" Max.6'-0" Sidewalk Backslo p e 4 1 Elev. 845.50 or Elev. 844.50 Sidewalk Profile: Structure Backfill Type 3 See Elevation4'-0" Min.1'-6"1'-6" 18"12"0.6 Tons No. 2 Stone at Each Drain. Elev. 846.25 or (See Sheet 49) SECTION "B-B" Scale: 3/4"=1'-0" 4'-9" 3 Spa.@ 1'-3"=3'-9" 1\"x3\" Keyway 4" Cl.4'-6" Minimum, 5'-9" Maximum#4 Horiz. Reinforcing Sidewalk Structure Backfill Type 3 4 Spa.@ 12"=4'-0"3"1'-0"Elev.850.25 North End 3"Varies#4 Bars Top & Botm. 3" Cl. Elev.848.56 South End 1'-6"Min. #4 Lap502 @ 12" 401 @ 12" #4x4'-3"@12" 6"6" #4 Long. Spacing Top & Bottom 10" Stem Up to 2" for Ashlar Stone Face Form 1'-1\" Min. 2'-9[ Max.6'-0" Sidewalk Backslo p e 4 1 Elev. 846.25 or Elev. 844.50 Sidewalk Profile: Structure Backfill Type 3 See Elevation4'-0" Min.1'-6"1'-6" #4x4'-3" @ 12" Front Face 504 @ 12" Rear Face 2"~ PVC Drain 10"1'-0" 24" Square of Geotextile for Underdrain at Inlet.1'-0"Affix to Wall. 2'-11" 18"12"0.6 Tons No. 2 Stone at Each Drain. (See Sheet 49) SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALE VERTICAL SCALE 1383180 1383180 R-36906 76 DIRECTORY PATH: R:\Active\Carmel\Guilford Road Des. No. 1383180\CAD\PlansFILENAME: RETAINING WALL.dwgDATE/USER: 7/20/2018 4:08 PM / AwolfWALL & SIDEWALK PROFILE Scales: 1"=10' Horiz, 1"=5' Vert. PLAN Scale: 1"=10'REND RAGD.DRAHCIR OF E SS ANO G N 19300106 STATE OF IR LPER I D AI ERN EE N ING D ERSIET A 04/02/2018RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: INDIANA DEPARTMENT OF TRANSPORTATION RDG AJWMAM RDG As Noted RETAINING WALL LOCATION & SECTIONS See Sheet 49 for Plan & Elevation with Reinforcing Details and Bar Bending Details. 46 30-504 R.F. & 30-#4x4'-3" F.F. & 30-401 51-503 R.F. & 51-#4x6'-2" F.F. & 51-401 20-504 R.F. & 20-#4x4'-3" F.F. & 20-401 1'-0"4'-6"5'-6"Elev. 844.50 Elev. 845.50 Elev. 850.00 Elev. 851.00 Elev. 852.00 Elev. 853.00 Elev. 854.00Elev. 854.00 Elev. 853.00Elev. 852.33Elev. 851.83 1'-0"4'-7"5'-7"Elev. 846.25 Elev. 847.25 Elev. 846.25 Elev. 845.50 Elev. 845.50 Elev. 844.506"8"1'-0"1'-0"1'-0"1'-0"1'-0"5'-1"5'-9"6'-9"7'-6"6'-6"6'-6"5'-6"10 Lines of 2-#4x26'-6" (5 Front Face, 5 Rear Face) 2-#4x22'-0" (1 FF, 1 RF) 2-#4x12'-0" (1 FF, 1 RF) 6-#4x29'-10" (3 FF, 3 RF) 8 Lines of 2-#4x26'-6" (4 FF, 4 RF) 2-#4x29'-10" (1 FF, 1RF) 2-#4x12'-0" (1 FF, 1 RF)2 Lines of 2-#4x15'-6" (1 FF, 1 RF)2 Lines of 2-#4x22'-0" (1 FF, 1 RF) 10'-0"10'-0"10'-0"10'-0"30'-0" Measured Along Front Face of Stem10'-0"10'-0"10'-0" 30'-0" Section "B-B"50'-0" Section "A-A"20'-0" Section "B-B" 100 Spaces @ 12" Max. = 99'-6"3"3" Spacing for Vertical Reinforcing in Stem Measured from Front Face of Stem RETAINING WALL ELEVATION Scale: 1/4"=1'-0" 505 in Step 12"506 in Step 12"9"12"2"~ Drains Spaced @ 10' Along Wall with No. 2 Stone "A" "A" "A" "A" "B" "B"North EndAlong Guilford South EndAlong Main St. "B" "B" See Plan view for Reinforcing in Footing. See Plan view for Reinforcing in Footing. 2'-0" Typ. #4 Lap 20'-0"20'-0"4'-9"1'-0"10"2'-11"433'-5" Radius438'-2" Radius48'-5" Radius54'-2" Radius143'-5 " R ad iu s148'-2 " Rad iu s Radius Break Point 2'-7 | " 2'-7 [ "5'-9"Radius Break Point 5'-3" 5'-5\ "5' -9 " 4 ' - 9 " 1 ' - 0 "10 " 2 ' - 11 " 8-#4x30'-0" 4 Top & 4 Bottom 10-#4x30'-0" 5 Top & 5 Bottom 8-#4x20'-0" 4 Top & 4 Bottom RETAINING WALL PLAN Scale: 1/4"=1'-0" 10-#4x30'-0" 5 Top & 5 Botm. 30-#4x4'-3" Top 30-502 Bottom 67-#4x5'-3" Top 67-501 Bottom 20-#4x4'-3" Top 20-502 Bottom 29'- 1 0 { " B a c k E d g e o f F o o t i n g A l o n g A r c 30'- 2 | " F r o n t E d g e o f F o o t i n g A l o n g A r c 19'-8 [" B a c k E d g e of F o oti n g Al o n g Ar c Spacing of end of bars at back end = 8["; Spacing of e n d o f b a r s at front en d = 9 } " ; Radiu s B r e a k P o i n t 53'-5{"Front Edge of Footing Along Arc 20'-4 \" Fr o nt E d g e of F o oti n g Al o n g Ar c 48'-4}"Back Edge of Footing Along Arc 10-506 in Step Footing Step 10-505 in Step Footing Step Spacing of Transverse Reinforcing in Footing & Stem for Section "B-B" is 12" Measured at Front Edge of Stem. Spa. @ 9" Spacing of Transverse Reinforcing in Footing & Stem for Section "B-B" is 12" Measured at Front Edge of Stem. Spacing of Transverse Reinforcing in Footing for Section "A-A" is 9" Measured at Front Edge of Stem. Spacing for Stem Steel is 12" measured at Front Edge of Stem. "B" "B" "A" "A" "B" "B" 2'-0" #4 Lap REINFORCING STEEL (lbs.) Weight (feet) Length Req'd Quan. Size Mark or CONCRETE MISCELLANEOUS Class "B" in Footing Surface Seal 491 Sft.* *Estimated Quantity Total #4 Reinforcing Total Plain Reinforcing Steel 4381 lbs. 19.9 Cys. 506 505 RETAINING WALL BILL OF MATERIALS 5'-9" 6'-0" 20'-0" 15'-6" 26'-6" 10 10 8 4 36 29'-10"8 401 6'-5"101 #4 30'-0"28 22'-0"6 504 6'-0"50 503 8'-0"51 502 5'-5"50 501 6'-5"67 Total #5 Reinforcing 1592 lbs. #4 #4 #4 #4 #4 12'-0"4#4 6'-2"51#4 5'-3"67#4 4'-3"100#4 Class "A" in Stem 18.2 Cys. Structure Backfill, Type 3 170 Cys. Foundation Excavation 202 Cys. Decorative Form Finish 235 Sft. 2789 lbs. Geotextiles 4 Sys. No. 2 Stone 5.4 Tons GENERAL NOTES fy=60,000 psiReinforcing Steel: Class "B" Concrete: f'c= 3,000 psi (Footing) Class "A" Concrete: f'c= 3,500 psi (Stem) DESIGN STRENGTHS: DESIGN DATA Reinforcing steel cover shall be 2" in Wall Faces, 3" in footings except bottom steel which shall be 4" and 2" in all other parts unless noted. Concrete in Footings shall be Class "B". Concrete in Retaining Wall Stem shall be Class "A". Continuous concrete pours shall be required between construction joints as shown on the detail plans. Chamfer exposed edges 1" unless noted. Exposed Front Surface of Stem shall have a decorative form finish. Exposed front face of stem, top of stem, ends of walls, and exposed rear face of stem to be surface sealed. 502 x 5'-5"3'-0"5" 401 x 6'-5" 7" Standard Hooks #5 5'-3" 501 4'-3" 502 501 x 6'-5"503 x 8'-0" 1'-2"6'-10" (503)504 x 6'-0"4'-10" (504)2'-6"1'-0"505 x 6'-0" 2'-6" 2'-6"9"506 x 5'-9" 2'-6" SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALE VERTICAL SCALE 1383180 1383180 R-36906 76REND RAGD.DRAHCIR OF ESS ANO G N 19300106 STATE OF IR LPER I D AI ERN EE N ING D ERSIET A 04/02/2018RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: INDIANA DEPARTMENT OF TRANSPORTATION RDG AJWMAM RDG DIRECTORY PATH: R:\Active\Carmel\Guilford Road Des. No. 1383180\CAD\PlansFILENAME: RETAINING WALL.dwgDATE/USER: 7/20/2018 4:08 PM / AwolfSee Sheet 48 for Section "A-A" & "B-B". See Sheet 48 for Plan & Elevation of Retaining Wall Area. As Noted RETAINING WALL LOCATION & SECTIONS 47 EROSION CONTROL LEGEND SILT FENCE TEMPORARY INLET PROTECTION1 RIPRAP DITCH CHECK (2' HEIGHT), MODIFIED FINAL CONTOURS (EXISTING AND PROPOSED)80512+0013+0014+0015+0016+0017+0018+0011+00Line "B" App. Exist. R/W App. Exist. R/WApp. Exist. R/W 12" Pipe 24" Pipe18" Pipe 18" Pipe 24" Pipe15" Pipe12" Pipe24" Pipe 12" Pipe12" Pipe15" Pipe18" PipeApp. Exist. R/WConstr. Limits S. GUILFORD ROAD W. CITY CENTER DRIVE845 845 845 844846 846 846 847 19+0020+0021+0022+0023+0024+0025+00Line "B" App. Exist. R/W App. Exist. R/W Section LineSection LineN0°01'40"W P.I. STA: 21+85.45 (No Curve) N0°06'57"E 12" Pipe1 2 " P i p e 10" San.12" San.6" San.12" San. 12" San.8" San.App. Exist. R/W App. Exist. R/W Constr. Limits Constr. Limits Constr. LimitsConstr. Limits 12" Pipe 12" PipeS. GUILFORD ROAD WATERLILY WAYW. 126th ST.1 1 1 11 1 1 1+64 "B"+06 "B"+73 "B"+73 "B"+87 "B"8 4 3 843 A.J.W. RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALEINDIANA DEPARTMENT OF TRANSPORTATION M.B. A.P. M.B. 4/2/2018 VERTICAL SCALE 1383180 1383180 R-36906 76ERR 1 S EF SPRONO. ASTATE OF D NIO IN LA AI N 01306 NGINE 27 EERIGEETS DANDREW JOHN W O L FDIRECTORY PATH: R:\Active\Carmel\Guilford Road Des. No. 1383180\CAD\PlansFILENAME: EC-PLANS.dwgDATE/USER: 7/20/2018 4:08 PM / Apercifield48 1"=30' 1"=5' EROSION CONTROL MATCH LINE 18+25 "B"MATCH LINE 26+00 "B"MATCH LINE 18+25 "B" EROSION CONTROL LEGEND SILT FENCE TEMPORARY INLET PROTECTION1 RIPRAP DITCH CHECK (2' HEIGHT), MODIFIED FINAL CONTOURS (EXISTING AND PROPOSED)80527+0028+0029+0030+0031+0032+0033+00Line "B" App. Exist. R/WApp. Exist. R/W N0°06'57"E 12" P i p e 18" Pipe12" Pipe12" Pipe 12" Pipe 12" Pipe 36" Pipe36" Pipe36" Pipe 24" Pipe 12" Pipe2 4 " P i p e12" Pipe24" Pipe 10" Pip e 12" San.12" San.12" San.12" San.24" San.12" San.12" San. App. Exist. R/W App. Exist. R/WApp. Exist. R/WApp. Exist. R/WApp. Exist. R/W Constr. Limits Constr. Limits Constr. Limits Constr. Limits App. Exist. R/W App. Exist. R/W 12" San . S. GUILFORD ROAD HELEN KEEN CT.COLLEGE WAYGRAND BLVD.11 1 1 1 1 1 1 1 1 1 1 1 1 1 +22 "B"+48 "B"+66 "B"+23 "B"+00 "B"+48 "B"+79 "B"+46 "B"+64 "B"+45 "B"+62 "B"+01 "B"+33 "B"840841 841 841842842 840840 840 841841 841 841 34+0035+0036+0037+0038+0039+0040+0041+00Line "B" App. Exist. R/W App. Exist. R/W N0°06'57"E10" Pipe24" Pipe 1 8 " P i p e 15" Pipe15" Pipe 12" Pi p e 24" Pipe 24" Pipe 12" Pipe 24" Pipe 24" Pipe12" Pipe? ? " P i p e 24" Pipe 24" Pip e 24" P i p e 24" P i p e 24" Pipe 24" Pipe 12" Pipe108" CMP12" Pipe 15" Pipe 15" Pipe 12" Pipe12" Pipe 12" San. 12" San.8" San.8" San.12" San. 12" San. App. Exist. R/W Constr. Limits Constr. Limits Constr. Limits Constr. Limits App. Exist. R/W App. Exist. R/WApp. Exist. R/W Constr. Limits S. GUILFORD ROAD EMERSON RD.1 1 1 1 1 1 1 1 11 11 1 1 1 1 1 Temporary Pump-around Required for Culvert Removal and Construction +40 "B"+50 "B"+79 "B"+21 "B"+49 "B"+80 "B"+37 "B"+81 "B"+73 "B"+98 "B"835 835 836 837 837 837 835 835 836 836 8 3 7 837 837 1 1 A.J.W. RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALEINDIANA DEPARTMENT OF TRANSPORTATION M.B. A.P. M.B. 4/2/2018 VERTICAL SCALE 1383180 1383180 R-36906 76ERR 1 S EF SPRONO. ASTATE OF D NIO IN LA AI N 01306 NGINE 27 EERIGEETS DANDREW JOHN W O L FDIRECTORY PATH: R:\Active\Carmel\Guilford Road Des. No. 1383180\CAD\PlansFILENAME: EC-PLANS.dwgDATE/USER: 7/20/2018 4:08 PM / Apercifield49 1"=30' 1"=5' EROSION CONTROL MATCH LINE 33+75 "B"MATCH LINE 26+00 "B"MATCH LINE 41+50 "B"MATCH LINE 33+75 "B" EROSION CONTROL LEGEND SILT FENCE TEMPORARY INLET PROTECTION1 RIPRAP DITCH CHECK (2' HEIGHT), MODIFIED FINAL CONTOURS (EXISTING AND PROPOSED)80542+0043+0044+0045+0046+0047+0048+0049+00Line "B" App. Exist. R/W App. Exist. R/W Line "S-1-B"N0°06'57"E N1°29'20"EN88°49'50"EN88°57'59"E15" Pipe P.I. STA: 48+20.44 (No Curve)12" Pipe12" Pipe12" Pipe12" Pipe1+002+00 Line "C" 12" San.8" San.12" San. 8" San.8" San.8" San.12" San.12" San.12" San.6" San.6"App. Exist. R/W App. Exist. R/WApp. Exist. R/WApp. Exist. R/WApp. Exist. R/WApp. Exist. R/WApp. Exist. R/WConstr. Limits Constr. Limits Constr. Limits Constr. Limits Constr. Limits App. Exist. R/W Do Not Disturb Sign S. GUILFORD ROAD DRUID HILL DR.WILSON TERRACE CT.W. MAIN ST.GUILFORD TRAIL DR.1 1 1 1 1 1 1 1 1 1 1 +02 "B"+93 "B"+04 "B"+43 "B"+78 "B"+24 "B"+65 "S-1-B"+18 "S-1-B"+84 "S-1-B"+83 "S-1-B"+10 "S-1-B"+30 "S-1-B"+31 "S-1-B"+25 "S-1-B"840839839 8 3 9 841 842 84 2 850 850 850 850 851 852 852 845 843844 846 847 848848 50+0051+0052+00Line "B" N1°29'20"E 12" Pipe App. Exist. R/W App. Exist. R/W Constr. Limits Constr. Limits N. GUILFORD ROAD+24 "B"+91 "B"+45 "B"+59 "B"850 850 850 847848 849 48+00W. MAIN ST.+18 "S-1-B"845846847848A.J.W. RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALEINDIANA DEPARTMENT OF TRANSPORTATION M.B. A.P. M.B. 4/2/2018 VERTICAL SCALE 1383180 1383180 R-36906 76ERR 1 S EF SPRONO. ASTATE OF D NIO IN LA AI N 01306 NGINE 27 EERIGEETS DANDREW JOHN W O L FDIRECTORY PATH: R:\Active\Carmel\Guilford Road Des. No. 1383180\CAD\PlansFILENAME: EC-PLANS.dwgDATE/USER: 7/20/2018 4:08 PM / Apercifield50 1"=30' 1"=5' EROSION CONTROL MATCH LINE 49+25 "B"MATCH LINE 41+50 "B"MATCH LINE 49+25 "B"MATCH LINE 8+50 "S-1-B" MATCH LINE 8+50 "S-1-B" A1 - PLAN INDEX Sheet 2. A2 - PLAT NO. 1 Sheet 4. A3 - NARRATIVE DESCRIBING THE NATURE AND PURPOSE OF THE PROJECT This project involves the reconstruction of Guilford Road from 126th Street to Main Street with a roundabout at the intersection of Guilford Road and Main street in Carmel, IN. A4 - VICINITY MAP Sheet 1. A5 - LEGAL DESCRIPTION Sheet 1. A6 - LOCATION OF LOTS AND SITE IMPROVEMENTS All improvements are shown on the plans. A7 - HYDROLOGIC UNIT CODE 05120201090030. A8 - NOTATION OF ANY STATE OR FEDERAL WATER QUALITY PERMITS Section 401 Water Quality Certification and Section 404 of the Clean Water Act. A9 - SPECIFIC POINTS WHERE STORM WATER DISCHARGE WILL LEAVE SITE Water will leave the site into Little Cook Creek at Station 39+75 "B" and local storm sewer along Main Street at Stations 8+00 and 12+10 "S-1-B". A10 - LOCATION AND NAME OF ALL WETLANDS, LAKES AND WATER COURSES ON AND ADJACENT TO SITE Little Cool Creek. A11 - IDENTIFICATION OF ALL RECEIVING WATERS City of Carmel storm sewers and Little Cool Creek. A12 - LOCATIONS OF POTENTIAL DISCHARGES TO GROUND WATER None. A13 - 100 YEAR FLOODPLAINS, FLOODWAYS, AND FLOODWAY FRINGES Flood areas are identified in FIRM maps on Sheet 42. A14 - PRE-CONSTRUCTION AND POST-CONSTRUCTION ESTIMATE OF PEAK DISCHARGE (10 YR STORM) Pre-construction discharge is estimated at 23.45 cfs and post-construction is estimated at 27.33 cfs. In-line detention will be utilized to eliminate this difference. A15 - ADJACENT LAND USE, INCLUDING UPSTREAM WATERSHED Land use is residential and commercial. A16 - LOCATION AND APPROXIMATE BOUNDARIES OF ALL DISTURBED AREAS Reference the construction limits as shown on the plans. A17 - IDENTIFICATION OF EXISTING VEGETATIVE COVER Trees and lawn. A18 - SOILS MAP INCLUDING SOIL DESCRIPTIONS AND LIMITATIONS Soils map can be found on Sheet 41. A19 - LOCATIONS, SIZE, AND DIMENSION OF STORM WATER SYSTEMS Storm sewer details are identified in the plans. A20 - PLANS FOR ANY OFF-SITE CONSTRUCTION ACTIVITIES ASSOCIATED WITH THIS PROJECT No off-site construction activities are anticipated to be associated with this project. A21 - LOCATIONS OF PROPOSED SOIL STOCKPILES, BORROW, AND/OR DISPOSAL AREAS Locations to be determined by Contractor and approved by INDOT. A22 - EXISTING TOPOGRAPHY AT AN INTERVAL APPROPRIATE TO INDICATE DRAINAGE PATTERNS Existing contours are shown on the plans. A23 - PROPOSED FINAL TOPOGRAPHY AT AN INTERVAL APPROPRIATE TO INDICATE DRAINAGE PATTERNS Proposed contours are shown on the plans. B1 - POTENTIAL POLLUTANT SOURCES ASSOCIATED WITH CONSTRUCTION ACTIVITIES There is a potential for pollutants associated with construction machinery including diesel fuel, hydraulic fluid, engine oils and lubricants, antifreeze, and other petroleum products. It is unavoidable for a small amount of these pollutants to contaminate soil in the grading and construction of the side. Sediment pollution from the site disturbing activities shall be remedied by erosion control measures (see following sections). B2 - SEQUENCE OF STORM WATER QUALITY MEASURE IMPLICATION 1. Silt fence and check dams shall be placed as shown in these plans. 2. All disturbed areas shall be mulched and seeded or sodded immediately after final grade has been established. No un-vegetated areas should be exposed for more than seven days. 3. Erosion control measures shall remain in place until 70% uniform vegetation is established. B3 - CONSTRUCTION ENTRANCES A line item for No. 2 Stone has been established to be utilized by the Contractor as needed for construction entrances throughout the jobsite. B4 - SEDIMENT CONTROL MEASURES FOR SHEET FLOW AREAS Silt fence locations are shown on the plans. Reference INDOT Standard Specifications Section 205 and Standard Drawing E 205-TECP-02. B5 - SEDIMENT CONTROL MEASURES FOR CONCENTRATED FLOW AREAS Traversable check dam locations are shown on the plans. Reference INDOT Standard Specifications Section 205 and Standard Drawing E 205-TECD-01 and E 205-TECD-02. B6 - STORM SEWER INLET PROTECTION MEASURES Storm sewer locations are shown on the plans. Reference INDOT Standard Specifications Section 205 and Standard Drawing E 205-TECI-04. B7 - RUNOFF CONTROL MEASURES Runoff control measures are shown on the plans as outlined in B4 and B5 (above). B8 - STORM WATER OUTLET PROTECTION MEASURES Outlet protection measures are shown on the plans. B9 - GRADE STABILIZATION STRUCTURES Erosion control blanket is to be placed on slopes greater than 3:1 as shown on these plans. B10 - LOCATION, DIMENSIONS, SPECIFICATIONS, AND DETAILS OF EACH STORM WATER QUALITY MEASURE All locations of planned measures are identified on the plans and listed in the Erosion Control Table. B11 - TEMPORARY SURFACE STABILIZATION All land disturbing activities are anticipated to be completed by Fall 2019. The land is expected to be covered with temporary measures until all final grades are established. B12 - PERMANENT SURFACE STABILIZATION Permanent seeding or sodding will be used on all disturbed earth. B13 - MATERIAL HANDLING AND SPILL PREVENTION See the Potential Storm Water Pollutants/Material Handling and Spill Prevention table (right). IDEM Emergency Response - 1-888-233-7745. B14 - MONITORING AND MAINTENANCE GUIDELINES Monitoring and Maintenance shall be within 24 hours of every 12 " or more rain event. B15 - EROSION AND SEDIMENT CONTROL MEASURES FOR INDIVIDUAL BUILDING LOTS Not applicable. C1 - PROPOSED POLLUTANTS AND SOURCES ASSOCIATED WITH PROPOSED LAND USE There is a potential for pollutants from vehicles including fuel, hydraulic fluid, engine oils, lubricants, antifreeze and other petroleum products. There are also the potential hazards of road salt, litter, etc. C2 - SEQUENCE DESCRIBING STORM WATER QUALITY MEASURES IMPLEMENTATION Riprap will be placed immediately after pipe placement or ditch grading where designated on the plans. Permanent seeding and sodding will be placed when proposed grades are met and there is no other significant construction in the immediate area. C3 - DESCRIPTION OF PROPOSED POST-CONSTRUCTION STORM WATER QUALITY MEASURES The City of Carmel has a requirement to remove 80% TSS. This requirement will be met as best as possible by the following methods: 1. Street sweeping will be performed at regular intervals by the City of Carmel. This will help remove pollutants from the roadway. 2. All structures have a 2 foot minimum sump. This will allow solids to settle out of the stormwater prior to running downstream. 3. In-line detention will be utilized to allow for the settling of pollutants and their removal rather than running directly downstream. 4. Riprap and sod will be placed where shown on the plans. Permanent sodding will prevent erosion on mild slopes. Riprap will prevent erosion at the ends of pipes and on more severe slopes. Both will also filter sediments and other pollutants. C4 - LOCATION, DIMENSIONS, SPECIFICATIONS, AND CONSTRUCTION DETAILS OF EACH STORM WATER QUALITY MEASURE Riprap and sodding locations are shown on the plans. Reference typical cross section sheets for ditch details. Reference INDOT specification sections 616 and 621 for sodding and seeding. All storm sewer locations are shown on the plans. C5 - DESCRIPTION OF MAINTENANCE GUIDELINES FOR POST-CONSTRUCTION STORM WATER QUALITY MEASURES Ditches shall be kept free of litter and other debris. Grass shall be mowed regularly and inspected for dead spots, excessive erosion, etc. These areas shall be repaired immediately. Street sweeping shall be performed at regular intervals. Storm sewer sumps shall be cleaned at regular intervals. Notes: 1.Storm Water Pollution Prevention (SWPP) checklist corresponds to the IDEM, Division of Soil Conservation Construction/Storm Water Pollution Prevention Plan Technical Review and Comment (Form 1) used in the Rule 5 permitting process. 2.The contractor shall use the SWPP checklist as a guide in preparing the SWPP plan required for Rule 5 procedures. 3.A site specific SWPP is to be submitted by the Contractor to INDOT prior to earth moving if any adjustments to the plan herein are requested. 4.The location of staging area and concrete washout area are to be submitted by the contractor. 5.Four Mobilization and Demobilization for seeding (LSUM) are estimated. 6.Contractor is to maintain clean roadways of all tracked construction materials and sediment throughout the day and at the end of each work day. *SEED MIXTURE = 150#/AC; MULCH = 2.5T/AC SILT FENCE LENGTH (LFT) EROSION CONTROL INLET PROTECTION LOCATION TEMPORARY EACH TOTAL ENTRANCES NO. 2 STONE CONSTRUCTION TEMP. GEOTEXTILES TONS SYS 400 940 Metal pins or staples to secure the polyethylene lining to the straw bales Polyethylene lining (10 mil); the lining should extend over the straw bales Straw bales entrenched 4 inches into the soil Compacted soil material Metal pins or staples to secure the polyethylene lining to the straw bales Wood or metal stakes to secure the straw bales (2 per straw bales) Straw bale (alternate materials or products may be used to provide structural containment) SECTION A-A Not to scaleL=10 FEETMetal pins or staples to secure the polyethylene lining to the straw bales Wood or metal stakes to secure the straw bales (2 per straw bale) Straw bale (alternate materials or products may be used to provide structural containment. Alternative materials or products will require design modification. Polyethylene lining (10 mil); the lining should extend over the straw bales. AA L = Inside Length W = Inside Width PLAN VIEW Not to scale W=10 FEET CONCRETE WASHOUT DETAIL Not to scale TEMP. SEEDING TEMP. SEED EROSION CONTROL TEMP. MULCH LBS.TON DISTURBED AREA ACRES MIXTURE B-15 TYPE CURB 26STATION TO STATION LINE LT/RT 27+22 to 27+48 RT 26 1605 B 4.6 690 11.6 C-15 CURB 16 E-7/F-7 DITCH 8 TOTAL 54 27+66 to 29+23 RT 178B 29+48 to 29+79 RT 50B 30+00 to 30+46 RT 45B 30+64 to 31+45 RT 81B 31+62 to 32+01 RT 48B 31+33 to 34+40 RT 217B 34+50 to 34+79 RT 48B 38+21 to 38+49 RT 50B 38+80 to 39+37 RT 97B 39+73 to 39+81 RT 60B 42+93 to 43+04 RT 34B 43+43 to 45+78 RT 271B 49+24 to 49+51 LT 68B 49+59 to 50+45 RT 100B 8+83 to 8+84 RT 43S-1-B 8+18 to 9+65 LT 158S-1-B 12+10 to 12+30 RT 22S-1-B 12+25 to 12+31 LT 9S-1-B EXISTING CURB 2 FOR EACH CONSTRUCTION PHASE, THE CONTRACTOR SHALL DESIGNATE A CONCRETE WASHOUT AREA WITHIN THE CONSTRUCTION LIMITS. THE WASHOUT AREA SHALL BE SUBJECT TO THE APPROVAL OF THE PROJECT ENGINEER/PROJECT SUPERVISOR. THE WASHOUT AREA SHALL BE FIFTY FEET FROM ANY STORM DRAIN, OPEN DITCH, OR BODY OF WATER. RUNOFF SHALL BE PREVENTED THROUGH CONSTRUCTION OF A PIT OR BERMED AREA LARGE ENOUGH FOR LIQUID AND SOLID WASTE. ALL CONCRETE TRUCKS SHALL BE REQUIRED TO WASHOUT AT THE DESIGNATED LOCATION. AFTER THE CONCRETE HAS SET THE WASTE SHALL BE BROKEN INTO SMALL ENOUGH PIECES FOR PROPER DISPOSAL. THE CONTRACTOR SHALL ENSURE THAT THE STORM WATER COLLECTION SYSTEM IS PROTECTED BY APPROPRIATE EROSION CONTROL MEASURES IN ACCORDANCE WITH 205. WASHOUT TO BE LINED WITH ONE SHEET OF PLASTIC AND THE WASHOUT WATER SHALL NOT BE ALLOWED TO TOUCH THE GROUND OR FLOW OUT OF THE WASHOUT. THE WASHOUT SHALL NOT BE USED ONLY IF IT REACHES HALF THE DAYS CAPACITY. TEMP. CHECK DAM REVETMENT RIPRAP TONS EROSION CONTROL STATION TOTAL REVET.FILTER TONSDAMSRIPRAPSTONE 1 GEOTEX. SYS TEMP. LINE LT/RT 6 1 2522+64 B LT 7 42 7 175 24+06 B LT 24+73 B LT 24+73 B RT 25+87 B RT 1 6 1 25 1 6 1 25 1 6 1 25 EXISTING DITCH 1 1 6 1 25 40+98 B RT 1 6 1 25 1 6 1 2542+02 B RT PUMP-AROUND DETAIL Not to scale flow Stream Diversion Pumps AA PLAN VIEW Not to scale SECTION A-A (SANDBAG DIKE SHOWN) Not to scale Pumps should discharge onto a stable velocity dissipator made of rip rap or sandbags Sump-hole or pool (12" to 18" deep 2' dia.)Impervious sheeting Work area Base flow + 1' (2' min.) Sediment dike Clean water dike flow Dewatering Pumps Work area Intake hose Intake hose J-15 MODIFIED CURB 1 A.J.W. RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALEINDIANA DEPARTMENT OF TRANSPORTATION M.B. A.P. M.B. 4/2/2018 VERTICAL SCALE 1383180 1383180 R-36906 76ERR 1 S EF SPRONO. ASTATE OF D NIO IN LA AI N 01306 NGINE 27 EERIGEETS DANDREW J OHN W O L FDIRECTORY PATH: R:\Active\Carmel\Guilford Road Des. No. 1383180\CAD\PlansFILENAME: SWPP-ELEMENTS.dwgDATE/USER: 7/20/2018 4:06 PM / ApercifieldSTORM WATER POLLUTION PREVENTION CONSTRUCTION PLAN ELEMENTS AND GENERAL NOTES 51 BEGIN PROJECT END PROJECT END PROJECT BEGIN PROJECT GUILFORD RD. GUILFORD RD.W. MAIN ST.W. MAIN ST.CrAMmB2MmC2MmC2ShBrCrAMmACrACrACrABrMmB2MmACrAMmB2A.J.W. RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALEINDIANA DEPARTMENT OF TRANSPORTATION M.B. A.P. M.B. 4/2/2018 VERTICAL SCALE 1383180 1383180 R-36906 76ERR 1 S EF SPRO NO. ASTATE OF D NIO IN LA AI N 01306 NGINE 27 EERIGEETS DANDREW J OHN W OL FDIRECTORY PATH: R:\Active\Carmel\Guilford Road Des. No. 1383180\CAD\PlansFILENAME: SWPP-ELEMENTS.dwgDATE/USER: 7/20/2018 4:06 PM / ApercifieldSTORM WATER POLLUTION PREVENTION CONSTRUCTION PLAN SOIL MAP 52 1" = 100' BEGIN CONSTRUCTION BEGIN PROJECT BEGIN CONSTURCTION BEGIN PROJECT END CONSTRUCTION END PROJECT END CONSTURCTION END PROJECT A.J.W. RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALEINDIANA DEPARTMENT OF TRANSPORTATION M.B. A.P. M.B. 4/2/2018 VERTICAL SCALE 1383180 1383180 R-36906 76ERR 1 S EF SPRO NO. ASTATE OF D NIO IN LA AI N 01306 NGINE 27 EERIGEETS DANDREW J OHN W OL FDIRECTORY PATH: R:\Active\Carmel\Guilford Road Des. No. 1383180\CAD\PlansFILENAME: SWPP-ELEMENTS.dwgDATE/USER: 7/20/2018 4:06 PM / ApercifieldSTORM WATER POLLUTION PREVENTION CONSTRUCTION PLAN FLOOD MAPS 53 1" = 200'