HomeMy WebLinkAboutM004.0Truss Connector Total List
Manuf Product Qty
MiTek JUS26 14
USP RT7A* 200
Start 2' O.C.
Spacing
Start 2' O.C.
Spacing
Start 2' O.C.
Spacing
Start 2' O.C.
Spacing
Start 2' O.C.
Spacing
Start 2' O.C. SpacingStart 2' O.C.
Spacing Start 2' O.C. SpacingM01M03M04(17) M02
(5) M05(7) JUS26C03C01(7) JUS26B03B01D02
D01
A05
A02
A01
V03V02V01V03V02V01(9) C02
(2) B02
(7) A02(5) A02(10) A04(2) A034-81-2-0
4-81-0-01-2-81-8-835-10-0
19-7-8 16-2-8
18-6-0
1-1-859-8-06-0-053-8-021-8-0
10-7-011-1-0
6-9-04-4-059-8-017-1-821-10-820-8-02-4-8 14-9-014-8-06-0-0IMPORTANT
THIS DRAWINGIS FORFIELD PLACEMENT OF INDIVIDUAL
COMPONENTS ONLY, AND DOES NOT CONSTITUTE AN
ENGINEERED DOCUMENT.
NOTE
PROPER BEARINGANDBEARINGDESIGN INCLUDING
ANCHORAGE, ISTHERESPONSIBILITY OF THE BUILDING
DESIGNER, ARCHITECT AND / OR BUILDINGENGINEER. REFER
TO INDIVIDUAL TRUSS DESIGNS FOR REACTIONS, MINIMUM
REQUIRED BEARINGSIZE, UPLIFT, AND ADDITIONAL LOADS.
84 COMPONENTS DOES NOT ASSUME RESPONSIBILITYIN
THESE AREAS OF CONCERN.
BRACING
ERECTION, TEMPORARY, AND PERMANENT BRACINGIS THE
RESPONSIBILITY OFTHE CONTRACTOR AND/ OR BUILDING
DESIGNER. REFER TO INDIVIDUAL TRUSS DESIGNS FOR
ADDITIONAL BRACINGREQUIREMENTS. REFER TO BCSI-B1
SUMMARY SHEET. THE STRUCTURAL BUILDINGCOMPONENTS
ASSOCIATION COMMENTARY, AND RECOMMENDATIONS FOR
HANDLING, INSTALLING&BRACINGMETALPLATE CONNECTED
WOOD TRUSSES. www.sbcindustry.com
INSTALLATION
DO NOT CUT, DRILL, OR ALTER TRUSSES. ANYQUESTIONS
CALL 84COMPONENTS. PROPER INSTALLATION, AND
HANDLINGOF COMPONENTS IS THE RESPONSIBILITY OFTHE
ERECTINGCONTRACTOR. 84COMPONENTS MUST BE
NOTIFIED OF ANY PROBLEMS, AND AFFORDED THE
OPPORTUNITY TO REVIEW, AND MAKE NECESSARY
CORRECTIONS, OR NO BACKCHARGES WILL BE ACCEPTED
ORAPPROVED.
WARNING
WARNINGS, AND INSTRUCTIONS FOR ERECTION
OFCOMPONENTS ARE INCLUDEDIN THEDELIVERY PACKAGE.
KEEP THIS INFORMATION ON THEJOB SITE. THESE
DOCUMENTS WILL ALSO BE NEEDED FORJOB SITE
INSPECTION. MISUSE AND IMPROPER INSTALLATION OF
COMPONENTS MAYRESULT IN FAILURE, BODILY INJURY, LOSS
OF PROPERTY, AND / ORLIFE.
RoofArea:
Overhang Length:
Eave Length:
Hip Length:
ValleyLength:
Ridge Length:
SHEETNUMBER:
SCALE: NTS
TCLL: 20.0 lb/ft²
TCDL: 10.0 lb/ft²
BCLL: 0.0 lb/ft²
BCDL:10.0 lb/ft²
Building Code: IRC 2012
Wind Speed: 115 mph
On-Center Spacing: 24" U.N.O.
2085.92 SF
177 LF
123.74 LF
0 LF
52.77 LF
95.54 LF
THIS LAYOUTIS INTENDED FOR THE PURPOSE OF TRUSS LOCATION AND PLACEMENTONLY. REFER TO THE BUILDING PLANS FOR ACTUAL BUILDING CONSTRUCTION.Chelsea, IndianaROOF TRUSS PLACEMENTPLAN2201740-2201740A1850 N Graham RoadFranklin, Indiana 46131Office:(317) 346-4274Fax: (317) 346-0916