Loading...
HomeMy WebLinkAbout06040121 Site Plan ~., Schneider <;f] 2 J)~ 170 v The Schneider Corporation Bl101 OUI .lftnue BiILoric ,art BarriBon ,...U.""y-II- IDdIana 482l8-I037 31?-II2ll-71llO 31?-II2ll-_m ~ - """"""'- GIS .US Geokv Note: This ,drawing is bosed on constructioo pions or record drawings, and IS not bosed upon a field survey. The Schneider Corporation does not worront the accuracy or sufficiency of this information. Contractors should verify existing conditions prior to ony construction. Any discrepancy found on this drawing should be reported to The Schneider Corporation immediately. foiling to do so results in the contractors assumption of all liability. '\.:L L . P11 Flood Hazard Statement: The accuracy of any flood hazard doto shown on this plot pion is subject to mop scole uncertainty and to any other uncertainty in location or elevation on the referenced flood insurance rote mop (FIRM). None of the within described land lies within that special flood hazard zone .A-, os said land plots by scale 00 Community !.top Panel , lBOS7C 020SF of the flood insurance rote mops (FIRM) for Hamilton County, Indiono, Ooted May 19, 1981. This Plot P1C1l Prepcnd for. ..,., Homes Lot # 47, contoiningl0,799 S.F.:l:, in Heather Knoll SectIon '1 Instrument , Unrecouled P.c. x, Slide xxx Clay Township, HcrnltCll County SEC_20._1l8N._ROJE _ 14361 CAMDEN LANE (50' R/W) Westfield, IN 46074 Prepared Dote: 04/11/06 : By: KAG Community Restrictions: Side Yard = 3' min. A99re90te = 6' 8.H. Zoning - SI M;1 Homes Finished Floor Elevation Information Pod Grode = 919.8 per plan Pod Grode + 0.2' = Garage FIT (920.0) Goroge FIT + O.S' = Residential FIT (920.S) Residence FIT - 9.0' = Basement FIT (911.S ) GROUNO COVER CALCULATIONS: Orive = 871 SFt Public Walk = 31 8 SH Privote Walk =N/A SFt Seeding =S,699 SFt Sod = 220 Srt, from front of residence. i M.H.(lll TC=9' g. 76 PER RECORD ORA\\\NG , I I .. '- w z: <( ---l z: W o L <( U .. M.H.(l10 TC=916.39 PER RECORO ORA\\\NG FLOOD HAZARD STATEMENT CERTlFICA TlON ,,,,,\1\1111111111//1/1/11111. #'\ c:.. L /1 i'0'~ # ~~..."........~~~~ ~~"~":"""'r_\STE~~.. ~.J'\~ f::$ _~."U N ....."..,:::::;: ~<::::).."q-" 0 o....;.o~ i ( 50303 ) I ~ " STATE OF.. ~ \(;f;>f.^,DIA~~"""~# '%.''1) "S"'U'''o',i \. ~ ,# ~41!. 1\' ~\'*'~ '/lllfI/III1Jllllll\\\\\\\\'\ VB06.0052050 LOT t 47 o ~ =~= Note: Bunder to ensure positive drainage away from structure(s). Plot Plan Legend []Q[Q] Proposed Grades 000.0 Existing Grades __ 000.0 -- Contour Grade * Approx. Lateral Location - . - Sanitary Sewer Lines -a'- Storm Sewer Lines - \I - Water Service Lines - - - - - - - Sub-Surface Drain Lines . Manhole (Sanitary or Storm) 81 Beehive iniet (Storm) l1li Curb Inlet (Storm) D End Section (Storm) .... Fire Hydrant - ...... - ...... - Flow line of swale - - Building Une (BL I BSL) - - - - - - - Easement Une Detan of Ground/Storm Water: Flow pattern of on i'ldividuallot.. [Q] =W= -- - - o Assumed North Scale: ,. = 30' Note: Sanitary Sewer Top of Casting Information Upstreom Manhole, TC= 919.76 Downstream Manhole, TC=916.39 per record drawing. NOTE: GARAGE FH. IS PROPOSED TO BE 1.4' ABO'll CURB AT ORIVEWAY T.B.M. JO.o' B-B C.A.#3 VAR. O.U.&S.S.E.& I 920.0 ILM.A.E. & 13 .00' . P.P.A.E. 10_0' <.0 U1 ~.3.J <.0 ~ (Xl Q2 CXl Cl Cl Cl '" ~ ~:;J~ ill~~~ Oil; !;!~ f;1 ~ ~ii1: ~ ~ i Oi : I I 1 I I ~I 1'1 ~: 918.5 40.7' 31.33' .. ~I ~~, ~ I ~ ~ I (Xl ,., ijC 135.00' 11* Note: The contractor is to maintain a minimum distance of ten feet (lO') between the sanitary sewer and water line loterals. o e: The basement elevotion, depicted hereon, has been determined and based upon the pad grades and/or contours token from the construction plans for this subdivision. Unless stated, no information about fluctuating water tables, son conditions, or son twes has been provided or stated on said plans. It is recommended that the basement finished floor e1evotions be at teast two feet (2') above the nannal pool elevction of any adpining bodies of water, unless 0 study of facts reveals otherwise. If during the excavction process any ground water is witnessed, The Schneider Corporation should be notified immediately. The basement elevction should be raised two feet (2') above the ground water, and additional construction techniques should be incorporated to alleviate future problems. Note: Sump pump(s) to be placed by builder os needed. NOTE: IN THE RESIDENTIAL DISTRICTS LIMITING HEIGHT TO TWENTY-FIVE (25) FEET, A DWELLING MAY BE INCREASED IN HEIGHT TO THIRTY-FIVE (35) FEET PROVIDED HE SIDE AND REAR YARDS ARE INCREASED AN ADDITiONAL FOOT FOR EACH FOOT SUCH STRUCTURE EXCEEDS TWENTY-FIVE (25) FEET IN HEIGHT. PER CARMEL ZONING ORDINANCE 26.1.1. NOTE: THE \\\THIN PLOT PLAN WAS PREPARED AT THE CUENfS REQUEST \\\THDUT BENEFIT or A RECORD PLAT. THE CON1RACTOR AND lOR BUIlDER HAS BEEN CAUTIONED THAT THE DEPICTED UNES SHO~ HEREON ARE SUB,[CT TO CHANGE. z :; '0 I '- TYPICAL SWALE SECTlON