Loading...
HomeMy WebLinkAbout06040122 Site Plan ~.,. Schneider The Schneider Corporation 8901 0tiI .beue BiItoric Fort HarriIoD 1n,1I.""P"H_, hutiana 48218-1037 317-1126-7100 317-828-7200 fa -- - """- .........- GIS .IJS GeoI'IJ This Plot PIon Pr8pared For: ../I Homes Lot # 17, containinglD,BDD S.F.:t, ;" Heather Knoll SectIon # 1 Instrument # Unrecorded P.c. x, Slide xxx Cloy _TOIlIIsh". HomBton County SEe 20. TIaN. ROJE 14373 Heather Knoll Pkwy (70' Westfield, IN 46074 Prepared Dote: 04/11/06 : By: Note: This drawing is based 00 construction plans or record drawings, and is not based upon a field survey. The Schneider Corporation does not warrant the accuracy or sufficiency of this information. Contractors should verify existing conditions prior to any construction. Any discrepancy found on this drawing should be reported to The Schneider Corporation immediately; foiling to do so results in the contractors assumption of 011 liabmty. Plot Pion Legend I 000.0 I Proposed Grodes 000.0 Existing Grades __000.0---:'" Contour Grode , * Approx. Lateral Location - . - Sanitary Sewer lines -.- Storm Sewer lines /l - 'vi - Water Service lines R f) - - - - - - - Sub-Surface Drain lines . Monhole (Sonitory or Stonn) .. 8eehive Inlet (Storm) AMA II1II Curb Inlet (Storm) D End Section (Storm) .... Fire Hydront - 000 _ 000 - Flow line of swale - 8uDding Line (8L / 8SL) - - - - - - - Easement line Community Restrictions: Side Yard = 3' min. Aggregote = 6' 8.H. Zoning - SI GROUND COVER CALCULATIONS: On,,; = g84 SF t Note: Sonitory Sewer Public Walk = 320 SH Top of Costing Informotion Pnvote Wolk =N/A SH Upstream Monhole, TC=918.53 Seeding =6,3g1 SH Downstreom Monhole, TC=gI9.76 Sod = 265 SYt, per record drwg. from front of residence. Note: The basement elevotion, depicted hereon, has been determined and based upon the pad grades and/or contours token from the construction plans for this subdivision. Unless stated, no information about fluctuating water tables, soil conditions, or soil t)pes has been provided or stated on said plans. Jt is _ recommended that the basement finished floor elevations be at least two feet (2') above the nannal pool elevotion of any adjoining bodies of water, unless a study of tacts reveals otherwise. If during the excavation process any ground water is witnessed, The Schneider Corporation should be notified immediately. The basement elevation should be raised two feet (2') above the ground water, and additional construction techniques should be incorporated to alleviate future problems. Note: Sump pump(s) to be placed by builder as needed. Note: The contractor is to maintain a minimum distonce of ten feet (10') between the sanitary sewer and water line laterals. NOTE: GARAGE: F.F.E. IS PROPOSED TO BE 1.0' ABO CURB AT DRIVEWAY IB.M. MJI Homes Finished Floor E1evction Information Pod Grode = 920.1 per pion Pod Grode + 0.2' = Goroge FIT (920.3) Goroge FIT + 0.5' = Residentlol FIT (920.8) Residence FIT - 9.0' = 80sement FIT (gl1.8) '" '" b '" :i ::E . o 4: 1 SLOPE: ~ ~'.' S\.o?( TYPICAL SWALE SECTION NOTE: IN THE RESIDENTIAL DISTRICTS LIMITING HEIGHT TO TWENTY-FIVE (25) FEET, A DWELLING MAY BE INCREASED IN HEIGHT TO THIRTY-FIVE (35) FEET PROVIDED THE SIDE AND REAR YARDS ARE INCREASED AN ADDITIONAL FOOT FOR EACH FOOT SUCH STRUCTURE EXCEEDS TWENTY-FIVE (25) FEET IN HEIGHT. PER CARMEL ZONING ORDINANCE 26.1.1. NOTE: lHE ~lHIN PLOT PLAN WAS PREPARED AT lHE aJENTs REQUEST ~lHOUT BENEFiT OF A RECORD PLA 1 lHE CONTRACTOR AND/OR BUILDER HAS 8EEN CAU1l0NED lHA r THE DEPICTED UN SHO~ HEREON ARE SUBJECT TO CHANGE:. FLOOD HAZARD STATEMENT CERllFICA 1l0N ROll CURB ,,11\\\1\\1111111//1/1//,,1. #"~c. L /l ~/~ ~,",.'.;, . l1;.ch~ ~ .::::... ~"...,......,......". (/J~~ ~~...t.G\s Te:I?~......"..A~ i2!! '" /~ No 0 "'. ;0'" I ~[ S0303 \ , ~ '. STATE OF.. ~ ~ /.... .... ~ ~~ 4.1;..:.IVDrA~!:... ~~ ~ 7/r;; """,...." C\" ;if ~4!. SUR~ "'~~#' W///I/JIIIIIIII\\\\\\\\\\~ ~l'f1i M.H. fl13 TC=918.53 PER RECORD DRA~NG Flood Hazard Statement: The accuracy of any flood hazard data shown on this plot plan is subject to mop scale uncertainty and to any other uncertainty in location or elevotion on the referenced flood insurance rote mop (FIRM). None of the within described land lies within thot speciol flood hazard zone -A., os said land plots by scale on Community Map Panel # 1800810001C of the flood insuronce rote maps (FIRM) for Homllton County, Indiono, Doted Moy 19, Ig81. TC= 918.83 PER RECORD DRA~NG I 918.5 I I- I 1 ;1 b "'I I I I I ~ THREE CAR 775' \3 6.58' - ~ GARAGE . : 10.33' ~ 2D.6';f.::i l<l CONC, DRIVE '-" ~ o 0_ 16.0' PER RECORD 1'1 ,.98 15<8.9 I 64.3' = 20.00 80.00' Detaa of Ground/Storm Water. Row pattern of an individud lot 15' D.E. 15' 54.3' I I I \ I I ,U, , I \ I 918.8 ~ Note: Builder to ensure positive drainage away from structure(s). 2.00' >- ~ >- '" ~ ,.; N IlECI( A 38.00 Vb06.0052047 LOT * 17 ~ ~ =~= B511NT SUMP PUMP EASTHAM B FRM ~ MSY RESIDENCE i:J ill 61 6.0' 919.9 25' B.L. 9 0.0 20' D.U.&E. * 20 ~ ASS1Jmed North Scole : 1. = 30' 919.6 16 * 6.0 o lot 80.00' APRON 5' WAlJ( 1'1 5.0' J6.0' lot PER fUN B-B mM ElIV=919.3 919.27 t; M.H.p11 TC=g19.76 PER RECQR[ ^ DRA:NG \1^Sn~V s s REVISION #1 ADDED SANITARY INFORMA llON '1806.0052889 04/20/06 - KAG