Loading...
HomeMy WebLinkAbout06040126 Site Plan ~ ~~ The Schneider Corporation 8901 OUI Avenue . ;_. . IIJJtorIc Fori BaniJon _ IndIanapolil. indiana la.2lH0S7 317-828-7100 Schneider 317-828-7200:AI This Plot Plan Prepared For: R.H. of Indiana Lot # 67 ,containing 10,488 S.F.:t, in Stanford Park Section I 1 INSlR. I 200500009385 P.C. I 3, Slide I sn CERnACA 1E of CORRECnON INSlR. I 200500044195 Clay T wp. HarnDton County Sec 29, TIaN, RJE 13808 Stanford Orive Carmel, IN 46074 - Prepared Date: 04/12/06: By. AMA Proposed Buyer(s): Yelena & Dmitriy Lysenko (50'R/W) Community Restrictions: Side Yard =3' min. Rear Yard = H(A Aggregate = 6 (B.H.) R.H. of Indiana Finished Floor Elevation Information Pad Grade = 916.2 per plan Pad Grade + 0.7' = Garage FFE (916.9) Garage FFE + 1.5' = Residential FFE (918.4) Residential FFE - 9.0' = Basement FFE (909.4) . !r1 J ta~e: -2- 'l t l.- L'f This drawing is based on construction plans or record drawings, and is not based upon 0 field survey. The Schneider Corporation does not warrant the accuracy or sufficiency of this information. Contractors shauld verify existing conditions prior to ony construction. Any discrepancy found on this drawing shauld be reported to The Schneider Corporation immediately; failing to do sa results in the contractors assumption of 011 iiability. Note: Per Carmel zoning ordinance 26.1.1 : The residential district limits height to twenty-five feet (25'), however 0 dwelling may be Increased in height to thirty-five feet (35') pro~ded the side and rear yards ore increased on additional one foot (1') for each one foot (1') the structure exceeds the first twenty-five feet (25') in height. !ciJneerinc SurveylDg Lancbca.pe Architecture GIS 'W Geo1OO Plat Plan Legend ~ Proposed Grades 000.0 Existing Grades __ 000.0-- Contour Grode * Appro,. Lateral Location - . - Sanitary Sewer lines -IT - Storm Sewer lines - 1,1 - Woter Service lines - - - - - - - Sub-Surface Drain lines . Manhole (Sanitary or Storm) . Beehive Iniet (Storm) l1li Curb inlet (Storm) D End Section (Storm) ..... Fire Hydrant - .. .. .. - .. .. .. - Flow line of swale Building Line (BL / BSL) - - - - - - - Easement line Lot # 67 Vb06.0052377 o ~ =~= DetaR of eroond/ Storm Water flow pattern for indlvlduollots. Nate: Sanitary Sewer Top of Casting Information Upstream Manhole, TC= 916.20 Downstream Manhole. TC=915.50 per plan. [QJ -M- -~- -- -- Note: The contractor is to maintain 0 minimum distance of ten feet (10') between the sanitry sewer and water line laterals. o Assumed North Scale: 1. = 30' Note : The garage finished floor elevation is 1.6' above the curb at the drive, per plan. Note: Sunder to ensure positive drainage away from structure(s}. ., ~ ~I ~< ~ TYPICAL $WALE SECTION I ~<=! " .,,~ 1 ~,... 1 ?;; g: ~ 1 1 -A. 1 .- -.: 1 ~ .... ..;1 1 I ""j '" . 1 1 :!? 1 ~ II ( ,.. I '" .1 ~I "a:> ~I N cx:i -I Lf) 46.4' 0> <.n. !'V '" 0J I; b 0 ,., 50.9' '" <;: II :..., , 51.1'- ~ 1:l 8 g .04 31.33 ~ z !Ii $" ~ /;;~ ~"tj ~:~ "Il'l:;! 39.37' 134.05' I SIR.' 727 II: ~. !'V Note: SUmp pump(s) to be placed by builder os needed. Note: The basement elevation, depicted hereon, has been determined and based upon the pod grades and/or contours taken from the construction plans for this subdivision. Unless stated, no information about fluctuating water tables, son conditions, or soil twes has been provided or stated on said plans. It is recommended that the basement fllllshed floor elevations be at least two feet (2') above the normal pool elevation of any adjoining bodies of water, unless 0 study of facts reveals otherwIse. If during the excavation process any ground water Is witnessed, The Schneider Corporation should be notified Immediately. The basement elevation should be raised two feet (2') above the ground water, and additional construction techniques should be incorporated to alleviate future problems. Sidewalk to be placed l' from property line, 4' from bock of curb, per plan. Flood Hazard Statement: The accuracy of any flood hazard data shown on this report is subject to map scale uncertainty and to any other uncertainty in location or elevation on the referenced flood insurance rate map. ALL of the within described land DOES NOT LIE within that special flood hazard zone A as said land plots by scare on flood insurance rate map # 18057 0205F for City of Carmel, Indiana (maps dated February 19, 2003). ~GNA lURE : DATE: ~GNA lURE REPRESENTS CON~RMA TION OF RECEIPT OF PLOT PLAN BY CUSTOI.IER. SIR.' 728 TC-920.5O PER PlAN REVlSION 11 ROTAlEO HOUSE PER ED 04/13/06 AMA I , I I I , 30.0' B-B FLOOD HAZARD STATEMENT CERnFICA nON ~\\I\\\I\\III1III1/1t1t1111. #\~~ L C, Y/~ ~~ ~ .........:.......:1' t'l"%' ~ ~....~G\SNTE:l?i.....~A~ g<:::)/~ o. ()....;<>~ r ( 50303 ) I :=:. ~ : .:::: % ..... STATE OF" ..... ~ ;;:::: /. . ~ ~ (At......(,IvOI A~ !':.....~~ %, '4lJ ..S....U..R..\it:~ #' ~/,I/, ., \.. ~~&- YIIIIII/i1tIJlII\I\\\I\I\I~ ~lf-f1