HomeMy WebLinkAbout06040126 Site Plan
~ ~~ The Schneider Corporation
8901 OUI Avenue
. ;_. . IIJJtorIc Fori BaniJon
_ IndIanapolil. indiana la.2lH0S7
317-828-7100
Schneider 317-828-7200:AI
This Plot Plan Prepared For: R.H. of Indiana
Lot # 67 ,containing 10,488 S.F.:t, in
Stanford Park
Section I 1
INSlR. I 200500009385
P.C. I 3, Slide I sn
CERnACA 1E of CORRECnON
INSlR. I 200500044195
Clay T wp. HarnDton County
Sec 29, TIaN, RJE
13808 Stanford Orive
Carmel, IN 46074 -
Prepared Date: 04/12/06: By. AMA
Proposed Buyer(s): Yelena & Dmitriy
Lysenko
(50'R/W)
Community Restrictions:
Side Yard =3' min.
Rear Yard = H(A
Aggregate = 6 (B.H.)
R.H. of Indiana
Finished Floor Elevation Information
Pad Grade = 916.2 per plan
Pad Grade + 0.7' = Garage FFE (916.9)
Garage FFE + 1.5' = Residential FFE (918.4)
Residential FFE - 9.0' = Basement FFE (909.4)
. !r1 J ta~e: -2- 'l t l.-
L'f This drawing is based on construction plans or record
drawings, and is not based upon 0 field survey. The
Schneider Corporation does not warrant the accuracy or
sufficiency of this information. Contractors shauld verify
existing conditions prior to ony construction. Any
discrepancy found on this drawing shauld be reported to
The Schneider Corporation immediately; failing to do sa
results in the contractors assumption of 011 iiability.
Note:
Per Carmel zoning ordinance 26.1.1 :
The residential district limits height to twenty-five
feet (25'), however 0 dwelling may be Increased in height
to thirty-five feet (35') pro~ded the side and rear yards
ore increased on additional one foot (1') for each
one foot (1') the structure exceeds the first
twenty-five feet (25') in height.
!ciJneerinc
SurveylDg
Lancbca.pe Architecture
GIS 'W
Geo1OO
Plat Plan Legend
~ Proposed Grades
000.0 Existing Grades
__ 000.0-- Contour Grode
* Appro,. Lateral Location
- . - Sanitary Sewer lines
-IT - Storm Sewer lines
- 1,1 - Woter Service lines
- - - - - - - Sub-Surface Drain lines
. Manhole (Sanitary or Storm)
. Beehive Iniet (Storm)
l1li Curb inlet (Storm)
D End Section (Storm)
..... Fire Hydrant
- .. .. .. - .. .. .. - Flow line of swale
Building Line (BL / BSL)
- - - - - - - Easement line
Lot # 67
Vb06.0052377
o
~
=~=
DetaR of eroond/ Storm
Water flow pattern for
indlvlduollots.
Nate: Sanitary Sewer
Top of Casting Information
Upstream Manhole, TC= 916.20
Downstream Manhole. TC=915.50
per plan.
[QJ
-M-
-~-
-- --
Note:
The contractor is to maintain 0 minimum
distance of ten feet (10') between the
sanitry sewer and water line laterals.
o
Assumed North
Scale: 1. = 30'
Note : The garage finished floor elevation
is 1.6' above the curb at the drive, per plan.
Note: Sunder to ensure
positive drainage away
from structure(s}.
., ~ ~I ~<
~
TYPICAL $WALE SECTION
I
~<=!
"
.,,~
1 ~,...
1 ?;; g: ~ 1
1 -A. 1
.- -.:
1 ~ .... ..;1
1 I ""j
'"
. 1
1 :!?
1
~ II (
,.. I
'" .1
~I
"a:> ~I
N
cx:i -I
Lf)
46.4'
0>
<.n. !'V
'" 0J I;
b 0
,., 50.9'
'"
<;: II
:..., ,
51.1'-
~
1:l
8
g
.04
31.33
~
z
!Ii
$"
~ /;;~
~"tj
~:~
"Il'l:;!
39.37'
134.05'
I SIR.' 727
II: ~. !'V
Note:
SUmp pump(s) to be placed by
builder os needed.
Note:
The basement elevation, depicted hereon, has been determined and based upon the
pod grades and/or contours taken from the construction plans for this subdivision.
Unless stated, no information about fluctuating water tables, son conditions, or soil
twes has been provided or stated on said plans. It is recommended that the
basement fllllshed floor elevations be at least two feet (2') above the normal pool
elevation of any adjoining bodies of water, unless 0 study of facts reveals
otherwIse. If during the excavation process any ground water Is witnessed, The
Schneider Corporation should be notified Immediately. The basement elevation should
be raised two feet (2') above the ground water, and additional construction
techniques should be incorporated to alleviate future problems.
Sidewalk to be placed
l' from property line,
4' from bock of curb,
per plan.
Flood Hazard Statement: The accuracy of any flood hazard data shown on this report is subject to
map scale uncertainty and to any other uncertainty in location or elevation on the referenced flood
insurance rate map. ALL of the within described land DOES NOT LIE within that special flood hazard
zone A as said land plots by scare on flood insurance rate map # 18057 0205F for City of Carmel,
Indiana (maps dated February 19, 2003).
~GNA lURE :
DATE:
~GNA lURE REPRESENTS CON~RMA TION OF RECEIPT OF PLOT PLAN BY CUSTOI.IER.
SIR.' 728
TC-920.5O
PER PlAN
REVlSION 11
ROTAlEO HOUSE
PER ED
04/13/06 AMA
I
,
I
I
I
,
30.0'
B-B
FLOOD HAZARD STATEMENT
CERnFICA nON
~\\I\\\I\\III1III1/1t1t1111.
#\~~ L C, Y/~
~~ ~ .........:.......:1' t'l"%'
~ ~....~G\SNTE:l?i.....~A~
g<:::)/~ o. ()....;<>~
r ( 50303 ) I
:=:. ~ : .::::
% ..... STATE OF" ..... ~
;;:::: /. . ~
~ (At......(,IvOI A~ !':.....~~
%, '4lJ ..S....U..R..\it:~ #'
~/,I/, ., \.. ~~&-
YIIIIII/i1tIJlII\I\\\I\I\I~
~lf-f1