HomeMy WebLinkAboutkiefer FINISHED layout (1)ROOF TRUSS PLACEMENT GUIDE
NOTE: ALL DIMENSIONS SHOWN 0-0-0 ARE IN FEET-INCHES-SIXTEENTHS
CUSTOMER: MICHAELIS CORP.MODEL: KIEFER JOBCOMMUNITY:SCALE:DATE:DESIGNED BY:LOT#:NOT TO SCALE9/12/22ROGER WILLIAMSSHIP DATE:Building CodeROOF LOADING:-IRC2018/TPI2014JOB #: J22206288THIS LAYOUT IS INTENDED FOR THE PURPOSE OF TRUSS LOCATION AND PLACEMENT ONLY. REFER TO THE BUILDING PLANS FOR ACTUAL BUILDING CONSTRUCTION
A) DO NOT CUT OR MODIFY TRUSSES.
B) TRUSSES ARE SPACED 24" ON CENTER
UNLESS NOTED OTHERWISE.
C) REFER TO THE INDIVIDUAL TRUSS DESIGN
DRAWINGS FOR THE LOCATION OF MEMBER
BRACING, UPLIFT, AND TRUSS END REACTIONS.
D) PER ANSI TPI 1-2002 THE TRUSS ENGINEER
IS RESPONSIBLE FOR DESIGNING THE TRUSS
TO TRUSS CONECTIONS AND TRUSS PLY TO PLY
CONNECTIONS. THIS PLACEMENT PLAN RECOMMENDS
TRUSS TO BEARING CONNECTIONS AND
TRUSS TO BEAM CONNECTIONS WHICH
SHALL BE REVIEWED BY THE BUILDING
DESIGNER TO RESOLVE ALL ROOF FORCES
ADEQUATELY TO THE FOUNDATION.
E) INSTALLATION OF ALL TEMPORARY
AND PERMANENT BRACES ARE
ESSENTIAL. SEE TRUSS DRAWINGS,
BCSI-B2 SUMMARY SHEET AND
BUILDING DESIGNER REQUIREMENTS.
NOTES:
3D VIEW 20 TLL 10 TDL 10 BDL9028 Old S.R. 67 SouthMooresville, IN 46158Phone: (317) 834-5380Fax: (317) 834-5390Carter-Lee Building ComponentsCERTIFIED PLANTTMTruss TechnicianTMProBuild North11058ProBuild NorthTTT Level IIIROGER WILLIAMSGE01GE02GE03GE04GE05GE06T01(8)
T02(9)T03(4)
T04(2)
T05(8)22-11-0012-08-002-05-006-00-00 15-11-08 18-10-00 10-09-08
2-05-0025-11-009-08-0027-08-0023-11-00 1-04-0816-03-00
2-00-002-00-002-00-002-00-002-00-002-00-002-00-001-10-00 5-001-04-082-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-001-11-08
2-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-001-11-00HTU26HTU26HTU26HTU26HTU26HTU26HTU26HTU26HTU26 DROP BEAM
FLUSH BEAM
STICK FRAME
09/30/22