HomeMy WebLinkAbout06040148 Site Plan
Note:
Contractor should verify site specific
information depicted hereon with the
approved construction plans for this
development. Also, Contractor should
reference Architectural plans for.
foundation orientation a~d dimensions.
&~~(1(]IJDj)@@] ~@[Jll[}U
@@@)D@g '(]" = ~@'
Note:
t~
Gar. FFE = 914.5
1st Fir FFE = 916.3
Bsm! FFE = 906.5
Drive Slope = 2.3%
(~-- LOT # 2
~ \ +14,250 SF
~ i PAD 914.2 PER PLAN
I
Minimum Front yard - Variable
Minimum Between Residences - 6'
Minimum Rear Yard - 20'
~-
I
wi
o
"'I
I
I
ij
---~
15'
~ 0 ~
~ "
" ,
10.00'
F R ~8
~
~ ::: -~~
200 .0
10,00' No::
o
o
L!)
OJ
---
5.3'
-L__~
~~
[;J"
-~
15' R.D.E.
STMINLET
TC=909.00
STM SEWER
150.00'
IXXXI = Proposed Grade
---'--- = Drainage Flow
XX.X = Existing Grade
Flood Hazard Note:
Lot Number 2 lies within Zone "X" per the scaled location on
the Flood Insurance Rate Maps for Hamilton County, Indiana
(Community Panel #18057C0205F, dated February 19, 2003).
Note:
This drawing is based upon construction plans and/or record
drawings prepared by others and is not based upon a field survey.
COOR Consulting & Land Services, Corp. does not warrant the
correctness or integrity of this information. The contractor/owner
should verify existing conditions prior to construction. Any varying
field conditions or any discrepancy with the information contained
hereon should be immediately reported to COOR Consulting & Land
Services, Corp.; failure to do so would result in the contractorfowners
assumption of liability.
oor@
@@O'O~(l}JD1J:oO'O\ID f%!:. D@)O'O@ ~@[J1'!70@@~~
@@[)'~@[)'@J(lD@[)j]
303 WEST MAIN STREET KNIGHTSTOWN. INDIANA
(888) 593-2667 (765) 345-5943 FAX#: (765) 345-5692
DATE: 04/20/06 JOB #2004-250.002 REVISIONS:
I
~.~ 1
" L_
~
W
llJ ~~
a:~
om
w~
~~ ~
~-
/
3:: /V'.....
llJ AC;,0
30.66'
/
15.0'
t
.-:...~
Note:
'"
W
;::
W
(f)
Z
'"
(f) o:;u]
uw
",z:2:
.0"
uo
/
26.0'
/
SANLAT
w
ui
(f)
""
:J
o
'"
N
WINDSOR 11- ELEV 1C
RIGHT HAND - Full Brick
FULL BSMT - 9' Walls
3 CAR - Side Entry
2' Fam Rm Ext
------.--- - ----
SAN MH 826
TC=913.10
co
'"
, I 0
~ M
"
~I
1
1
1
1
;::1
G'
ill
"
ill
'"
t'.
Iw
>
0::
o
(/)~
fEo::
1 ~-
<l:~
1
I@
Iw
"
31~
u
-l
10.0'
Cone Flatwork Sq. Ft = ot1658
Public Walk Sq Ft = ot475
Sod Sq Yds = ot352
Seeding Sq Ft = H531
The proposed construction grades depicted hereon are based upon
information, proposed grades and/or contours, taken from the
approved construction plans prepared for this subdivision. Unless
stated hereon, no information pertaining to but not limited to,
fluctuating water table elevations, soil types or conditions within the
building area of said lot, has been provided or referenced on said
plans. With the construction of a basement, it is recommended that
the lowest floor elevation be constructed at least two (2) feet above
any adjoining bodies of water unless a study of facts reveals
otherwise. Should any ground water be witnessed during the
excavation of said structure. the lowest floor elevation should be
raised at least two (2) feet above the ground water level and
additional construction techniques should be incorporated to
alleviate future problems.
LONGRIDGE ESTATES
SECTION ONE
PC 3, SLIDE 729
INSTR #200500063316
LOT # 2
13668 AKERS DRIVE
WESTFIELD, IN 46074
Kt~
PLOT PLAN
Prepared For:
.""".""
. ~
n~lfe:
r:~/?I.ed-)
Pul!e Homes of Indiana