Loading...
HomeMy WebLinkAbout06040148 Site Plan Note: Contractor should verify site specific information depicted hereon with the approved construction plans for this development. Also, Contractor should reference Architectural plans for. foundation orientation a~d dimensions. &~~(1(]IJDj)@@] ~@[Jll[}U @@@)D@g '(]" = ~@' Note: t~ Gar. FFE = 914.5 1st Fir FFE = 916.3 Bsm! FFE = 906.5 Drive Slope = 2.3% (~-- LOT # 2 ~ \ +14,250 SF ~ i PAD 914.2 PER PLAN I Minimum Front yard - Variable Minimum Between Residences - 6' Minimum Rear Yard - 20' ~- I wi o "'I I I ij ---~ 15' ~ 0 ~ ~ " " , 10.00' F R ~8 ~ ~ ::: -~~ 200 .0 10,00' No:: o o L!) OJ --- 5.3' -L__~ ~~ [;J" -~ 15' R.D.E. STMINLET TC=909.00 STM SEWER 150.00' IXXXI = Proposed Grade ---'--- = Drainage Flow XX.X = Existing Grade Flood Hazard Note: Lot Number 2 lies within Zone "X" per the scaled location on the Flood Insurance Rate Maps for Hamilton County, Indiana (Community Panel #18057C0205F, dated February 19, 2003). Note: This drawing is based upon construction plans and/or record drawings prepared by others and is not based upon a field survey. COOR Consulting & Land Services, Corp. does not warrant the correctness or integrity of this information. The contractor/owner should verify existing conditions prior to construction. Any varying field conditions or any discrepancy with the information contained hereon should be immediately reported to COOR Consulting & Land Services, Corp.; failure to do so would result in the contractorfowners assumption of liability. oor@ @@O'O~(l}JD1J:oO'O\ID f%!:. D@)O'O@ ~@[J1'!70@@~~ @@[)'~@[)'@J(lD@[)j] 303 WEST MAIN STREET KNIGHTSTOWN. INDIANA (888) 593-2667 (765) 345-5943 FAX#: (765) 345-5692 DATE: 04/20/06 JOB #2004-250.002 REVISIONS: I ~.~ 1 " L_ ~ W llJ ~~ a:~ om w~ ~~ ~ ~- / 3:: /V'..... llJ AC;,0 30.66' / 15.0' t .-:...~ Note: '" W ;:: W (f) Z '" (f) o:;u] uw ",z:2: .0" uo / 26.0' / SANLAT w ui (f) "" :J o '" N WINDSOR 11- ELEV 1C RIGHT HAND - Full Brick FULL BSMT - 9' Walls 3 CAR - Side Entry 2' Fam Rm Ext ------.--- - ---- SAN MH 826 TC=913.10 co '" , I 0 ~ M " ~I 1 1 1 1 ;::1 G' ill " ill '" t'. Iw > 0:: o (/)~ fEo:: 1 ~- <l:~ 1 I@ Iw " 31~ u -l 10.0' Cone Flatwork Sq. Ft = ot1658 Public Walk Sq Ft = ot475 Sod Sq Yds = ot352 Seeding Sq Ft = H531 The proposed construction grades depicted hereon are based upon information, proposed grades and/or contours, taken from the approved construction plans prepared for this subdivision. Unless stated hereon, no information pertaining to but not limited to, fluctuating water table elevations, soil types or conditions within the building area of said lot, has been provided or referenced on said plans. With the construction of a basement, it is recommended that the lowest floor elevation be constructed at least two (2) feet above any adjoining bodies of water unless a study of facts reveals otherwise. Should any ground water be witnessed during the excavation of said structure. the lowest floor elevation should be raised at least two (2) feet above the ground water level and additional construction techniques should be incorporated to alleviate future problems. LONGRIDGE ESTATES SECTION ONE PC 3, SLIDE 729 INSTR #200500063316 LOT # 2 13668 AKERS DRIVE WESTFIELD, IN 46074 Kt~ PLOT PLAN Prepared For: ."""."" . ~ n~lfe: r:~/?I.ed-) Pul!e Homes of Indiana