Loading...
HomeMy WebLinkAboutS001.2 - Lower Level Foundation Plan - Garages3/0 8/0 PD. K-3322-RAGABRIELLETOILETSVITREOUSCHINAs&r3/0 8/0 3/0 8/0 3/0 8/0 2/8 8/0 80'-11 1/4" 10'-11 1/4"23'-5" 13'-11"4'-9"15'-7"12'-4" 52'-11"4'-0"48'-11"18'-1"30'-10"41'-0 1/2"6'-0"15'-6 1/2"7'-9 1/2"7'-9 1/2"25'-7 1/4"8'-0"9 1/2"6'-4 3/4"22'-2 1/2"3'-5" 10'-6" 9 1/2"38'-6" 20'-0" 5 1/2" 4'-0"8'-11 1/2" 5 1/2" 16'-0 1/2"9 1/2" 25'-7 1/4" 11 1/2"26'-0"11 1/2"11 1/2"26'-0"11 1/2" 13'-3" 5 1/2" 7'-1" 5 1/2" 4'-8 1/2" 9 1/2"9 1/2"14'-6"5 1/2"7'-0 1/2"4'-7"2'-1"67'-5 1/2"37'-10"29'-7 1/2"27'-11"26'-3 1/4"2'-10"9'-3"2'-5"9'-3"2'-6 1/4"2'-6 1/4"9' - 3 " 2'- 5 " 9' -3 "8'-8 1/2"4' - 0 3 / 4 "36'-2 1/2"WINE LIVING BDRM. #3 BDRM. #1 UNEXC. up 19 R. RAILING 1'-2"s&r K-3322-RAGABRIELLETOILETSVITREOUSCHINA K-3322-RAGABRIELLETOILETSVITREOUSCHINA UNFINISHED DROPPED STEEL BEAM NO CURB SHWR. BDRM. #2 WIC.16" "I" JTS @16" O.C.16" "I" JTS @16" O.C.16" "I" JTS @16" O.C.16" "I" JTS @16" O.C.16" "I" JTS @16" O.C.UNEXCAVATED 4" CONC. SLAB OVER VAPOR BARRIER AND MINIMUM 4" COMPACTED GRANULAR FILL UNEXCAVATED 4" CONC. SLAB OVER VAPOR BARRIER AND MINIMUM 4" COMPACTED GRANULAR FILL DROPPED LVL BEAM DROPPED LVL BEAM 9 1/2"5 1/2"5 1/2"12'-11 1/2"5 1/2"7'-7 1/2"5 1/2"3'-7"9 1/2"6'-1 1/2"3'-7"6'-2"9 1/2"3'-6"5 1/2"5'-0" 5 1/2"2'-6 1/2"5 1/2"18'-4 1/2"3/0 8/0 3/0 8/0 2/8 8/0 PR. 2/6 8/0 LINENS 8'-5" 5 1/2" 5'-0" PR. 2/6 8/0 PR. 2/6 8/0REF.5'-8"3'-10"6'-6"9 1/2"6'-6" 12'-8 1/4"15'-4 1/4"24'-1 3/4" 5 1/2" 9 1/2"8'-10"5 1/2"4'-6"8'-11"5'-11 1/2"2'-4 1/2"9 1/2"9 1/2"6'-5"5 1/2"28'-0"5 1/2"PR. 3/0 8/0 2'-0" 1'-9" 16'-6" 6'-9"6'-2"11 1/2"9'-2"8'-0 7/8"11 1/2"15'-6 1/2" 8'-6 1/2"9 1/2"8'-5 1/2"7'-0"2804 S.F. FINISHED LIVING LOWER LEVEL SQ. FT. 1688 S.F. UNFINISHED D. W.sHELVESLAUNDRY SINK DROP TOP OF FOUNDATION WALL 8" AT DOOR OPENINGS TYPICAL DROP TOP OF FOUNDATION WALL 8" AT DOOR OPENINGS TYPICAL LOWER LEVEL PLAN NOTES: THESE NOTES APPLY THE LOWER LEVEL / FOUNDATION SHEETS ONLY 12" x 32" REINFORCED POURED CONCRETE FROST FOUNDATION WALL WITH 5 1/2" X 12" MASONRY LEDGE. STEP TOP OF WALL AND FOOTING AS REQUIRED FOR EXISTING GRADES. 22" X 10" POURED CONCRETE FOOTING WITH 3-#4 REBAR CONTINUOUS TYPICAL. 10" x 120" REINFORCED POURED CONCRETE FOUNDATION WALL WITH 5 1/2" X 12" MASONRY LEDGE. STEP TOP OF WALL AND FOOTING AS REQUIRED FOR EXISTING GRADES.21'-11 3/4"STEEL COLUMN STEEL COLUMNSTEEL COLUMNSTEEL COLUMN 2X4 WALL SET 1" IN FROM ALL LOWER LEVEL EXTERIOR PERIMETER WALLS. PROVIDE FULL BATT INSULATION IN EACH STUD SPACE. REINFORCED POURED CONCRETE COLUMN FOOTING PAD. DO NOT SCALE PAD SIZE FROM THIS DRAWING. G.C. MUST VERIFY LOADING, PAD SIZE, AND REINFORCING REQUIRED. 22" X 10" POURED CONCRETE FOOTING WITH 3-#4 REBAR CONTINUOUS under all bearing walls. STEEL COLUMN 2 1/2"11 1/2"6'-4 1/2"8" POURED CONCRETE RETAINING WALL W/ 12" BRICK LEDGE OUTSIDE AND THIN VENEER BRICK INSIDE4'-4 1/2"7 1/2"29'-7 1/2" 4'-1 1/2"7'-4"4'-1 1/2"3'-0" MIN.6'-0"8'-4"DRAIN DROP FLOOR 3 1/2"3'-0" MIN.8" POURED CONCRETE RETAINING WALL W/ 12" BRICK LEDGE OUTSIDE AND THIN VENEER BRICK INSIDE 3'-0" MIN. 3'-0" MIN. DRAIN 5'-1 7/8"5'-0"5'-4"8" 41 ' - 1 0 3 / 4" 8" POURED CONCRETE WALL W/ THIN BRICK VENEER ALL SIDES 135.0 0 ° 135 .00°45.00 ° INCOMING ELECTRICAL SERVICE reinforced poured concrete pad poured concrete pad DROP FLOOR 3 1/2" NO CURB SHWR.4'-4 1/2"A/C CONC. SLAB gen. 14'-11 7/8" DROPPED LVL BEAM STEEL COLUMN 12'-8 1/4" DROPPED LVL BEAM STEEL COLUMN 8" x 32" REINFORCED POURED CONCRETE FROST FOUNDATION WALL WITH 5 1/2" X 12" MASONRY LEDGE. STEP TOP OF WALL AND FOOTING AS REQUIRED FOR EXISTING GRADES. 9'-9 1/2" CLG. 9'-9 1/2" CLG. 9'-9 1/2" CLG. 9'-9 1/2" CLG. 9'-9 1/2" CLG. 9'-9 1/2" CLG.9'-9 1/2" CLG. UNEXCAVATED 4" CONC. SLAB OVER VAPOR BARRIER AND MINIMUM 4" COMPACTED GRANULAR FILL FURN. 1ST FLR. FD. ELEC. M.D. PANELS FURN. LWR. LEVEL FD. WATER A/V DROP TOP OF FOUNDATION WALL 8" AT DOOR OPENINGS TYPICAL 3'-4 3/8"32'-6 1/4"3660-1 hd. @ 96" 3660-2 hd. @ 96"SHADED AREA INDICATES DROPPED CEILING FOR DUCTWORK - KEEP HIGH AS POSSIBLE WIC. 5 1/2" 4'-0" 5 1/2" 7'-10" s&r 8'-3"1'-5"7'-5 1/2"14'-3 1/2"9 1/2"1'-9 1/4"5 1/2"DN. (4) 6" R.9 1/2"3'-11 5/8"5 1/2"11'-9 1/2" CLG. LOW WALL WITH CAP TO MATCH VIEWING COUNTER FRAME WALL BELOW VIEWING COUNTER BULKHEAD HIGH AS POSSIBLE LINE OF 8" POURED CONCRETE FOUNDATION WALL - SEE AUXILIARY PLAN ON SHEET A-3.2 FLOOR -2'-0" STEP FOOTING AND FOUNDATION WALL DOWN A TOTAL OF 24". G.C. VERIFY STEP LOCATIONS AND NUMBER REQUIRED 10" x 144" REINFORCED POURED CONCRETE FOUNDATION WALL WITH 5 1/2" X 12" MASONRY LEDGE. STEP TOP OF WALL AND FOOTING AS REQUIRED FOR EXISTING GRADES. 7'-0" 3'-0 1/4"135.00°5 1/2"4'-0"3'-2"2'-1"UNFINISHED SUMPSUMP S.e. SANITARY GOLF SIMULATOR LINE OF 8" POURED CONCRETE FOUNDATION WALL SIMULATOR FLOOR -2'-0" 2022-0506 07-08-2022 Project No: Sheet Title REVISIONS Date: Sheet No.1008 LaurelwoodCarmel, IN 46032THE JONES FAMILYAn All New Residence for:GARY NANCE DESIGNArchitectural Concepts By200 South Rangeline Road, Suite 214 Carmel, IN 46032317.605.2196 Pgnance@garynancedesign.com garynancedesign.comThese design concepts are the property of Gary Nance Designand may not be used without approval from Gary Nance DesignA R C H I T E C T S+A S S O C I A T E S2520 Durbin DriveCarmel , Indiana 46032317-733-8525hsark@sarkassociates.comLOWER LEVEL / FOUNDATION PLAN - GARAGES A-3.2 LOWER LEVEL / FOUNDATION PLAN - GARAGES SCALE: 1/4" = 1'-0" 9 1/2" 6'-8 1/2" 7 1/2" 23'-8" 7 1/2" 10'-8 1/2" 9 1/2"7 1/2"20'-2"9 1/2"AUXILIARY LOWER FOUNDATION PLAN @ GOLF SIMULATOR DROPPED FLOOR SCALE: 1/4" = 1'-0"U:\02-RESIDENTIAL L-Z\Nance, G\2022-0419_Jones\02-CDs\2022-0506_Jones_A-3.0 LLP.dwg, 7/8/2022 5:45:33 PM,DWG To PDF.pc310/04/22