HomeMy WebLinkAboutS300.0 - Wall Sections10'-11 3/8" RAFTER BEARINGFIRST FLOOR LOWER LEVEL BEDROOM 1st finish floor line 1'-5 1/2"10'-1 1/8"9'-9 1/2"1'-4 3/4"FINISHED GRADE 3'-8"(44" MAX.)3'-0" MINIMUM3'-8"MAX.WATERPROOFING REINFORCED POURED CONCRETE WALLS WITH THIN VENEER AS SHOWN 3'-0" MINIMUM 8'-0" WINDOW HEAD5'-7 1/2"9'-3 1/2" G.C. VERIFY2'-9 1/8"4" REINFORCED CONCRETE SLAB 4" GRANULAR FILL INTERIOR PERIMETER DRAIN TILE SIZE BY G.C. RUN TO SUMP PIT VAPOR BARRIER 22" WIDE BY 10" DEEP POURED CONCRETE FOOTING WITH 3-#4 REBAR CONTINUOUS 2" X 6" TREATED WOOD PLATE 2" X 6" WOOD STUDS AT 16" O.C. 1" AIR SPACE EXPANSION STRIP 1/2" GYPSUM BOARD 1/2" GYPSUM BOARD 2- 2" X 6" TOP PLATES 1/2" X 10" ANCHOR BOLTS AT 6'-0" O.C. MAX. AND 12" IN FROM ALL CORNERS 3-2X12 WITH 1/2" PLYWOOD FILLER MINIMUM TYPICAL DOOR AND WINDOW HEADER SOUND INSULATION EXTERIOR PERIMETER DRAIN TILE SIZE BY G.C. RUN TO SUMP PIT ALUMINUM CLAD EXTERIOR, WOOD INTERIOR WINDOW WITH INSULATING GLASS TYPICAL WOOD TRIM BEYOND LIMESTONE TRIM LIMESTONE TRIM CORRUGATED METAL TIES AT 24" O.C. HORIZONTALLY AND 16" O.C. VERTICALLY 3/4" T&G PLYWOOD SUB-FLOOR GLUED AND SCREWED 1" MIN. AIR SPACE STONE OR BRICK VENEER - SEE ELEVATIONS FOR EXACT LOCATIONS CUT LIMESTONE WINDOW TRIM TYPICAL 2" X 6" CONTINUOUS WOOD PLATE CONTINUOUS PERIMETER RIM JOISTS ENGINEERED FLOOR JOISTS AT 16" O.C. VERIFY WITH G.C. WOOD BASE TBD. VAPOR BARRIER 2" X 6" STUDS AT 16" 0.C. TYP. METAL SILL TRIM AS REQUIRED 2- 2" X 6" SILL PLATES CUT LIMESTONE WINDOW TRIM TYPICAL ALUMINUM CLAD EXTERIOR, WOOD INTERIOR WINDOW WITH INSULATING GLASS TYPICAL 2- 2" X 6" TOP PLATES 1/2" GYPSUM BOARD 3/8" PLYWOOD SOFFIT 2" X FRAMING 1" X 8" FASCIA 2" X SUB-FASCIA CONTINUOUS ALUMINUM GUTTER CONTINUOUS SOFFIT VENT CONTINUOUS ALUMINUM ROOF EDGE 7/16" OSB ROOF SHEATHING ROOF PROTECTION MEMBRANE STARTER SHINGLE ROOF SHINGLE AS SPEC'D 2" X 8" RAFTERS AND CEILING JOISTS AT 16" O.C.INSULATION BAFFLE R-50 MIN. ATTIC INSULATION 12 3-2X12 WITH 1/2" PLYWOOD FILLER MINIMUM TYPICAL DOOR AND WINDOW HEADER R-19 FULL BATT INSULATION SEE ROOF PLAN SEE ROOF PLAN CUT LIMESTONE WINDOW TRIM TYPICAL STEEL ANGLE LINTEL 8'-0" WINDOW HEADGRANULAR FILL WATERPROOFING #4 DOWEL AT 24" O.C. REINFORCED POURED CONCRETE BASEMENT WALL. SEE LOWER LEVEL / FOUNDATION PLAN FOR WALL THICKNESS EXTERIOR PERIMETER DRAIN TILE SIZE BY G.C. RUN TO SUMP PIT 4" REINFORCED CONCRETE SLAB 4" GRANULAR FILL INTERIOR PERIMETER DRAIN TILE SIZE BY G.C. RUN TO SUMP PIT VAPOR BARRIER 22" WIDE BY 8" DEEP POURED CONCRETE FOOTING 2" X 4" FLAT CONTINUOUS WOOD PLATE 2" X 4" WOOD STUDS AT 16" O.C. 1" AIR SPACE EXPANSION STRIP 3 1/2" BATT INSULATION 1/2" GYPSUM BOARD 1/2" GYPSUM BOARD 2" X 4" TOP PLATE 1/2" X 10" ANCHOR BOLTS AT 6'-0" O.C. MAX. AND 12" IN FROM ALL CORNERS FINISHED GRADE CORRUGATED METAL TIES AT 24" O.C. HORIZONTALLY AND 16" O.C. VERTICALLY 3/4" T&G PLYWOOD SUB-FLOOR GLUED AND SCREWED 1" MIN. AIR SPACE 1/2" GYPSUM BOARD 2- 2" X 6" TOP PLATES 1/2" GYPSUM BOARD 1/2" EXTERIOR SHEATHING STONE OR BRICK VENEER - SEE ELEVATIONS FOR EXACT LOCATIONS CUT LIMESTONE OR BRICK SILL - SEE ELEVATIONS FOR EXACT LOCATIONS 2" X 6" CONTINUOUS WOOD PLATE CONTINUOUS PERIMETER RIM JOISTS ENGINEERED FLOOR JOISTS AT 16" O.C. VERIFY WITH G.C. SOUND INSULATION WOOD BASE TBD.9'-9 1/2"10'-1 1/8"1" X 6" TRIM WITH CEDAR SHINGLE SIDING 3/8" PLYWOOD SOFFIT 2" X FRAMING 1" X FASCIA 2" X SUB-FASCIA CONTINUOUS ALUMINUM GUTTER CONTINUOUS SOFFIT VENT CONTINUOUS ALUMINUM ROOF EDGE 7/16" OSB ROOF SHEATHING ROOF PROTECTION MEMBRANE STARTER SHINGLE ROOF SHINGLE AS SPEC'D 2" X 8" RAFTERS AND CEILING JOISTS AT 16" O.C. INSULATION BAFFLE R-38 MIN. ATTIC INSULATION VAPOR BARRIER 12 2" X 6" STUDS AT 16" 0.C. TYP. TOTAL WALL "R" VALUES BRICK / STONE 1/2" GYPSUM BOARD INSIDE AIR FILM OUTSIDE AIR FILM BRICK / STONE AIR SPACE R-BOARD INSUL. SHEATHING BATT INSULATION 26.00 0.44 0.17 4.60 0.66 19.00 0.68 0.45 MEMBRANE FLASHING 3-2X12 WITH 1/2" PLYWOOD FILLER MINIMUM TYPICAL DOOR AND WINDOW HEADER ALUMINUM CLAD EXTERIOR, WOOD INTERIOR WINDOW WITH INSULATING GLASS TYPICAL WOOD TRIM BEYOND 2- 2" X 6" SILL PLATES MEMBRANE FLASHING R-19 FULL BATT INSULATION SEE ROOF PLAN SEE ROOF PLAN CONTINUOUS PERIMETER RIM JOISTS 45 MIL. EPDM RUBBER FLASHING MEMBRANE WEEP VENTS AT 24" O.C. 5 1/2" X 8" LEDGE INSULATED OVERHEAD DOOR OVERHEAD DOOR TRACK BEYOND REINFORCED POURED CONCRETE APRON GARAGE'S 4" REINFORCED CONCRETE SLAB 4" GRANULAR FILL VAPOR BARRIER EXPANSION STRIP 22" WIDE BY 10" DEEP POURED CONCRETE FOOTING 12" POURED CONCRETE FOUNDATION WALL. VERIFY HEIGHT WITH GRADES #4 DOWEL AT 16" O.C.2'-8" VERIFY1/2" GYPSUM BOARD VAPOR BARRIER PAVED DRIVE CONTINUOUS DRIP EDGE AS REQUIRED BEVELED LIMESTONE BAND G.C. VERIFY OHD. FRAME AND TRIM BEYOND CONTINUOUS TRIPLE LVL HEADER VERIFY WITH G.C.FULL BATT R-19 INSULATION 1X6 TRIM BRICK SOLDIER BRICK WAINSCOT BEYOND VERIFYSEE ELEVATIONSFIRST FLOOR LINE 2022-0506 07-08-2022 Project No: Sheet Title REVISIONS Date: Sheet No.1008 LaurelwoodCarmel, IN 46032THE JONES FAMILYAn All New Residence for:GARY NANCE DESIGNArchitectural Concepts By200 South Rangeline Road, Suite 214 Carmel, IN 46032317.605.2196 Pgnance@garynancedesign.com garynancedesign.comThese design concepts are the property of Gary Nance Designand may not be used without approval from Gary Nance DesignA R C H I T E C T S+A S S O C I A T E S2520 Durbin DriveCarmel , Indiana 46032317-733-8525hsark@sarkassociates.comTYPICAL WALL SECTIONS A-7.0 TYPICAL WALL SECTION WITH BASEMENT WINDOW SCALE: 3/4" = 1'-0" TYPICAL WALL SECTION WITH BASEMENT SCALE: 3/4" = 1'-0" TYPICAL GARAGE HEADER SECTION SCALE: 3/4" = 1'-0"U:\02-RESIDENTIAL L-Z\Nance, G\2022-0419_Jones\02-CDs\2022-0506_Jones_A-7.0 WALL SECTIONS.dwg, 7/8/2022 5:45:51 PM,DWG To PDF.pc310/04/22