HomeMy WebLinkAboutS300.0 - Wall Sections10'-11 3/8" RAFTER BEARINGFIRST
FLOOR
LOWER
LEVEL
BEDROOM
1st finish floor line
1'-5 1/2"10'-1 1/8"9'-9 1/2"1'-4 3/4"FINISHED
GRADE
3'-8"(44" MAX.)3'-0"
MINIMUM3'-8"MAX.WATERPROOFING
REINFORCED
POURED
CONCRETE
WALLS WITH
THIN VENEER
AS SHOWN
3'-0"
MINIMUM
8'-0" WINDOW HEAD5'-7 1/2"9'-3 1/2" G.C. VERIFY2'-9 1/8"4" REINFORCED
CONCRETE SLAB
4" GRANULAR FILL
INTERIOR PERIMETER
DRAIN TILE SIZE BY G.C.
RUN TO SUMP PIT
VAPOR BARRIER
22" WIDE BY 10" DEEP
POURED CONCRETE FOOTING
WITH 3-#4 REBAR CONTINUOUS
2" X 6" TREATED WOOD
PLATE
2" X 6" WOOD STUDS
AT 16" O.C.
1" AIR SPACE
EXPANSION STRIP
1/2" GYPSUM BOARD
1/2" GYPSUM BOARD
2- 2" X 6" TOP PLATES
1/2" X 10" ANCHOR BOLTS
AT 6'-0" O.C. MAX. AND 12"
IN FROM ALL CORNERS
3-2X12 WITH 1/2" PLYWOOD
FILLER MINIMUM TYPICAL DOOR
AND WINDOW HEADER
SOUND INSULATION
EXTERIOR PERIMETER
DRAIN TILE SIZE BY G.C.
RUN TO SUMP PIT
ALUMINUM CLAD EXTERIOR,
WOOD INTERIOR WINDOW WITH
INSULATING GLASS TYPICAL
WOOD TRIM BEYOND
LIMESTONE
TRIM
LIMESTONE TRIM
CORRUGATED METAL TIES AT 24" O.C.
HORIZONTALLY AND 16" O.C. VERTICALLY
3/4" T&G PLYWOOD SUB-FLOOR GLUED AND SCREWED
1" MIN. AIR SPACE
STONE OR BRICK VENEER - SEE
ELEVATIONS FOR EXACT LOCATIONS
CUT LIMESTONE WINDOW TRIM TYPICAL
2" X 6" CONTINUOUS WOOD PLATE
CONTINUOUS PERIMETER RIM JOISTS
ENGINEERED FLOOR JOISTS AT 16"
O.C. VERIFY WITH G.C.
WOOD BASE TBD.
VAPOR BARRIER
2" X 6" STUDS AT 16" 0.C. TYP.
METAL SILL TRIM AS REQUIRED
2- 2" X 6" SILL PLATES
CUT LIMESTONE WINDOW TRIM TYPICAL
ALUMINUM CLAD EXTERIOR,
WOOD INTERIOR WINDOW WITH
INSULATING GLASS TYPICAL
2- 2" X 6" TOP PLATES
1/2" GYPSUM BOARD
3/8" PLYWOOD SOFFIT
2" X FRAMING
1" X 8" FASCIA
2" X SUB-FASCIA
CONTINUOUS ALUMINUM GUTTER
CONTINUOUS SOFFIT VENT
CONTINUOUS ALUMINUM ROOF EDGE
7/16" OSB ROOF SHEATHING
ROOF PROTECTION MEMBRANE
STARTER SHINGLE
ROOF SHINGLE AS SPEC'D
2" X 8" RAFTERS
AND CEILING JOISTS
AT 16" O.C.INSULATION BAFFLE
R-50 MIN. ATTIC
INSULATION
12
3-2X12 WITH 1/2" PLYWOOD
FILLER MINIMUM TYPICAL DOOR
AND WINDOW HEADER
R-19 FULL BATT INSULATION
SEE
ROOF
PLAN
SEE ROOF PLAN
CUT LIMESTONE WINDOW TRIM TYPICAL
STEEL ANGLE LINTEL
8'-0" WINDOW HEADGRANULAR FILL
WATERPROOFING
#4 DOWEL AT 24" O.C.
REINFORCED POURED CONCRETE
BASEMENT WALL. SEE LOWER LEVEL /
FOUNDATION PLAN FOR WALL
THICKNESS
EXTERIOR PERIMETER DRAIN
TILE SIZE BY G.C. RUN TO SUMP
PIT
4" REINFORCED CONCRETE
SLAB
4" GRANULAR FILL
INTERIOR PERIMETER DRAIN TILE
SIZE BY G.C. RUN TO SUMP PIT
VAPOR BARRIER
22" WIDE BY 8" DEEP
POURED CONCRETE
FOOTING
2" X 4" FLAT CONTINUOUS WOOD
PLATE
2" X 4" WOOD STUDS AT 16" O.C.
1" AIR SPACE
EXPANSION STRIP
3 1/2" BATT INSULATION
1/2" GYPSUM BOARD
1/2" GYPSUM BOARD
2" X 4" TOP PLATE
1/2" X 10" ANCHOR BOLTS
AT 6'-0" O.C. MAX. AND 12"
IN FROM ALL CORNERS
FINISHED
GRADE
CORRUGATED METAL TIES AT
24" O.C. HORIZONTALLY AND
16" O.C. VERTICALLY
3/4" T&G PLYWOOD SUB-FLOOR
GLUED AND SCREWED
1" MIN. AIR SPACE
1/2" GYPSUM BOARD
2- 2" X 6" TOP PLATES
1/2" GYPSUM BOARD
1/2" EXTERIOR SHEATHING
STONE OR BRICK VENEER -
SEE ELEVATIONS FOR EXACT
LOCATIONS
CUT LIMESTONE OR BRICK
SILL - SEE ELEVATIONS FOR
EXACT LOCATIONS
2" X 6" CONTINUOUS
WOOD PLATE
CONTINUOUS PERIMETER RIM
JOISTS
ENGINEERED FLOOR JOISTS
AT 16" O.C. VERIFY WITH G.C.
SOUND INSULATION
WOOD BASE TBD.9'-9 1/2"10'-1 1/8"1" X 6" TRIM WITH
CEDAR SHINGLE SIDING
3/8" PLYWOOD SOFFIT
2" X FRAMING
1" X FASCIA
2" X SUB-FASCIA
CONTINUOUS ALUMINUM GUTTER
CONTINUOUS SOFFIT VENT
CONTINUOUS ALUMINUM ROOF EDGE
7/16" OSB ROOF SHEATHING
ROOF PROTECTION MEMBRANE
STARTER SHINGLE
ROOF SHINGLE AS SPEC'D
2" X 8" RAFTERS AND
CEILING JOISTS AT 16"
O.C.
INSULATION BAFFLE R-38 MIN. ATTIC
INSULATION
VAPOR BARRIER
12
2" X 6" STUDS AT 16" 0.C. TYP.
TOTAL
WALL "R" VALUES
BRICK / STONE
1/2" GYPSUM BOARD
INSIDE AIR FILM
OUTSIDE AIR FILM
BRICK / STONE
AIR SPACE
R-BOARD INSUL. SHEATHING
BATT INSULATION
26.00
0.44
0.17
4.60
0.66
19.00
0.68
0.45
MEMBRANE FLASHING
3-2X12 WITH 1/2" PLYWOOD
FILLER MINIMUM TYPICAL DOOR
AND WINDOW HEADER
ALUMINUM CLAD EXTERIOR,
WOOD INTERIOR WINDOW WITH
INSULATING GLASS TYPICAL
WOOD TRIM BEYOND
2- 2" X 6" SILL PLATES
MEMBRANE FLASHING
R-19 FULL BATT INSULATION
SEE
ROOF
PLAN
SEE ROOF PLAN
CONTINUOUS PERIMETER RIM
JOISTS
45 MIL. EPDM
RUBBER FLASHING
MEMBRANE
WEEP VENTS AT 24"
O.C.
5 1/2" X 8" LEDGE
INSULATED OVERHEAD DOOR
OVERHEAD DOOR
TRACK BEYOND
REINFORCED POURED
CONCRETE APRON
GARAGE'S
4" REINFORCED CONCRETE SLAB
4" GRANULAR FILL
VAPOR BARRIER
EXPANSION STRIP
22" WIDE BY 10" DEEP
POURED CONCRETE FOOTING
12" POURED CONCRETE FOUNDATION
WALL. VERIFY HEIGHT WITH GRADES
#4 DOWEL AT 16" O.C.2'-8" VERIFY1/2" GYPSUM BOARD
VAPOR BARRIER
PAVED DRIVE
CONTINUOUS DRIP EDGE AS
REQUIRED
BEVELED LIMESTONE
BAND G.C. VERIFY
OHD. FRAME AND TRIM
BEYOND
CONTINUOUS TRIPLE
LVL HEADER
VERIFY WITH G.C.FULL BATT R-19 INSULATION
1X6 TRIM
BRICK SOLDIER
BRICK WAINSCOT
BEYOND
VERIFYSEE ELEVATIONSFIRST FLOOR LINE
2022-0506
07-08-2022
Project No:
Sheet Title
REVISIONS
Date:
Sheet No.1008 LaurelwoodCarmel, IN 46032THE JONES FAMILYAn All New Residence for:GARY NANCE DESIGNArchitectural Concepts By200 South Rangeline Road, Suite 214 Carmel, IN 46032317.605.2196 Pgnance@garynancedesign.com garynancedesign.comThese design concepts are the property of Gary Nance Designand may not be used without approval from Gary Nance DesignA R C H I T E C T S+A S S O C I A T E S2520 Durbin DriveCarmel , Indiana 46032317-733-8525hsark@sarkassociates.comTYPICAL WALL
SECTIONS
A-7.0
TYPICAL WALL SECTION
WITH BASEMENT WINDOW
SCALE: 3/4" = 1'-0"
TYPICAL WALL SECTION
WITH BASEMENT
SCALE: 3/4" = 1'-0"
TYPICAL GARAGE
HEADER SECTION
SCALE: 3/4" = 1'-0"U:\02-RESIDENTIAL L-Z\Nance, G\2022-0419_Jones\02-CDs\2022-0506_Jones_A-7.0 WALL SECTIONS.dwg, 7/8/2022 5:45:51 PM,DWG To PDF.pc310/04/22