HomeMy WebLinkAboutM002.0 - EWP LayoutIndianapolis Design Center352 South County Road 300 EDanville, IN 46122317-745-9984These placement plans have been prepared with the specifications of TrussJoist products based on project information provided. This service is solely intended for product application assurance; and, is not intended to circumvent the needfor a design professional as determined by the building codes. The designer of record and/or builder/framer is responsible to assure these drawings are compatible with the overall project. These documents are not intended to replace the building plan (which should be used to determine bearing placement).Please insure measurements of the foundation match those provided at the timeof design. Builder is responsible to place load bearing members in load path.Architectural Drawings Prepared By:Structural Drawings Prepared By:84 Lumber FranklinKevin BeherPyatt BuildersTG129Rev.ByDateCommentsDrawn By:Checked By:Date:DW9/23/22Marin
Sheet
1 of 1
Ceiling System
Not to Scale
Confirm this layout with the builder and designer of record. Make
sure all discrepencies are corrected before ordering floor system.
All Dimensions are Approximate and Must Be Field Verified. 11 7/8" TJI Joists 24" O.C. SpacingFraming Connector Summary
PlotID Qty Manuf Product Design Method Face Nails Top Nails Member Nails Skew Slope Backer Blks Filler Web Stiff
H1 1 Simpson IUS1.81/11.88 Designed 10- 10dx1.5 -2- Strong-Grip --2 No No
H201 29 User IUS3.56/11.88 User Defined --Not Required No Not Required
Products
PlotID Length Product Plies Net Qty
FJ201 28' 0" 11 7/8" TJI 110 joist 1 5
FJ202 24' 0" 11 7/8" TJI 110 joist 1 4
FJ203 16' 0" 11 7/8" TJI 110 joist 1 2
FJ204 14' 0" 11 7/8" TJI 110 joist 1 3
FJ205 12' 0" 11 7/8" TJI 110 joist 1 12
FJ206 6' 0" 11 7/8" TJI 110 joist 1 4
FJ207 28' 0" 11 7/8" TJI 360 joist 1 1
FJ208 18' 0" 11 7/8" TJI 360 joist 1 10
FJ209 18' 0" 11 7/8" TJI 560 joist 1 1
BM201 22' 0" 1 3/4" x 24" 2.0E Microllam LVL 2 2
BM202 22' 0" 1 3/4" x 16" 2.0E Microllam LVL 3 3
BM203 18' 0" 1 3/4" x 11 7/8" 2.0E Microllam LVL 2 2
BM204 14' 0" 1 3/4" x 11 7/8" 2.0E Microllam LVL 2 2
BM205 4' 0" 1 3/4" x 9 1/4" 2.0E Microllam LVL 2 8
Ca201 16' 0" 1 1/8" x 11 7/8" TJ Rim Board 1 10
Blocking
PlotID Length Product Plies Net Qty
Bk201 2' 0" 11 7/8" TJI 110 joist 1 8
LEVEL NOTES
Current Date: 9/23/2022
File Name: tg42_2102506.jvl
Level Name: Second Floor System
Building Code - Design Methodology: IBC 2012
Members with Design Overridden:
TJ-Pro Rating (Weighted Average): 48
Minimum Level TJ - Pro Rating & Joist: TJ-Pro rating = 35, joist = FJ203(i2862)
Maximum Level TJ - Pro Rating & Joist: TJ-Pro rating = 58, joist = FJ203(i2882)
FLOOR
Floor Container: FC2
Use/Occupancy: ResidentialLivingAreas
Floor Area Loading is: 40.0 lb/ft² Live Load & 10.0 lb/ft² Dead Load
Operator Added Additional Loads
Maximum Allowed Deflection: L/480 Live Load & L/240 Total Load
TJ-Pro Rating Information:
Weighted Average: 48
Directly Applied Ceiling: Gypsum 1/2"
Decking Attachment: Glue and Nail
Decking Material: 23/32"x48"x96" Weyerhaeuser Edge Panel (0/24) T&G FF
Perpendicular Partition: No
Strapping at max 8' o.c.: None
Blocking at max 8' o.c.: No
Poured Flooring: No
B4
B1
B4
B1
A3
A3
A3
A3
A3
A3
A3
H2
H2
H2
H2
CS
CS
CS BBO8BBO7
BM205BM202 BM204BM205BM205BBO12BBO11
VO1
VO2
VO3
VO4
BM203
BM201FJ208
FJ208
FJ208
FJ205FJ208
FJ205FJ208
FJ205FJ208
FJ205FJ208
FJ205FJ209
FJ205FJ208
FJ205
FJ204FJ206
FJ204
FJ206
FJ207
FJ203
FJ203
FJ201
FJ201
FJ201
FJ201
FJ201
FJ202
FJ202
FJ202
FJ202
FJ205
FJ205
FJ205
Ca201
Ca201
Ca201
Ca201
Ca201Ca201Ca201Ca201Ca201Ca201
Ca201
FJ208
FJ208
Bk2011' 0" 2' 0" 1' 0" FJ205 Bk201FJ205
2' 0" 1' 0" FJ206FJ206FJ2041' 0" 2' 0" 9 1/2"1' 0 1/2"1' 5 7/16"11 9/16"5' 1 1/8"9' 9 3/4"
BM205
H201
H201
H201
H201
H201
H201
H201 H201
H201
H201
H201
H201
H201
H201
H201
H201
H201
H201
H201
H201
H201
H201
H201
H201
H201
H201
H201
H201
H1H201Beam given 7 1/2" bearing for joistconnection.Flush beam depth greater than floor joist depth. Verifyall loading and framing conditions prior to construction.24" beam.6" bearing req.
There are different joist series of the same
depth specified on this floor system. Verify
when installing that the proper TJI® joists
are used in the appropriate area.
TJI joists will all be replaced with IB-700.
Corresponding connectors will be replaced with
IUS3.56/11.88.