HomeMy WebLinkAboutM004.0 - Truss Layout Start 2' O.C.
Spacing
Start 2' O.C. Spacing Start 2' O.C. Spacing Start 2' O.C.
Spacing
Start 2' O.C. Spacing Start 2' O.C. Spacing Start 2' O.C. Spacing Start 2' O.C.
Spacing
Start 2' O.C. SpacingM03C01M01M06(4) M04(3) C02
(5) M02(8) M05
(11) HUS26
B03
E01
B01
(8) HUS26 D03
D01
A01A03A04A05A06A08V11
V10
V09
V08
V07
V01
V02
V03
V04
V05
V06
Two SBP4
Two SBP4
(2) E02(3) B02(3) D02(2) A02(7) A07
35-10-0
28-0-07-10-0
10-4-017-8-0
59-8-033-0-020-8-06-0-05-0-028-0-06-4-021-8-013-6-07-2-035-9-15
5-5-010-7-019-10-0
12-0-07-10-0 59-8-013-2-035-2-011-4-05-0-0 8-2-06-4-0 5-0-01-10-81-0-0
1-2-8
1-0-81-10-8IMPORTANT
THIS DRAWING IS FOR FIELD PLACEMENT OF INDIVIDUAL
COMPONENTS ONLY, AND DOES NOT CONSTITUTE AN
ENGINEERED DOCUMENT.
NOTE
PROPER BEARING AND BEARING DESIGN INCLUDING
ANCHORAGE, IS THE RESPONSIBILITY OF THE BUILDING
DESIGNER, ARCHITECT AND / OR BUILDING ENGINEER. REFER
TO INDIVIDUAL TRUSS DESIGNS FOR REACTIONS, MINIMUM
REQUIRED BEARING SIZE, UPLIFT, AND ADDITIONAL LOADS.
84 COMPONENTS DOES NOT ASSUME RESPONSIBILITY IN
THESE AREAS OF CONCERN.
BRACING
ERECTION, TEMPORARY, AND PERMANENT BRACING IS THE
RESPONSIBILITY OF THE CONTRACTOR AND / OR BUILDING
DESIGNER. REFER TO INDIVIDUAL TRUSS DESIGNS FOR
ADDITIONAL BRACING REQUIREMENTS. REFER TO BCSI-B1
SUMMARY SHEET. THE STRUCTURAL BUILDING COMPONENTS
ASSOCIATION COMMENTARY, AND RECOMMENDATIONS FOR
HANDLING, INSTALLING & BRACING METAL PLATE CONNECTED
WOOD TRUSSES.www.sbcindustry.com
INSTALLATION
DO NOT CUT, DRILL, OR ALTER TRUSSES. ANY QUESTIONS
CALL 84 COMPONENTS. PROPER INSTALLATION, AND
HANDLING OF COMPONENTS IS THE RESPONSIBILITY OF THE
ERECTING CONTRACTOR. 84 COMPONENTS MUST BE
NOTIFIED OF ANY PROBLEMS, AND AFFORDED THE
OPPORTUNITY TO REVIEW, AND MAKE NECESSARY
CORRECTIONS, OR NO BACK CHARGES WILL BE ACCEPTED
OR APPROVED.
WARNING
WARNINGS, AND INSTRUCTIONS FOR ERECTION
OF COMPONENTS ARE INCLUDED IN THE DELIVERY PACKAGE.
KEEP THIS INFORMATION ON THE JOB SITE. THESE
DOCUMENTS WILL ALSO BE NEEDED FOR JOB SITE
INSPECTION. MISUSE AND IMPROPER INSTALLATION OF
COMPONENTS MAY RESULT IN FAILURE, BODILY INJURY, LOSS
OF PROPERTY, AND / OR LIFE.
Roof Area:
Overhang Length:
Eave Length:
Hip Length:
Valley Length:
Ridge Length:
SHEET NUMBER:
R1.1
Roof Truss
Placement Plan
SCALE: NTS
Job#: A00048A
PO#:
Date: 9/23/2022
Drawn By: MB
Designed By: MB
Checked By: MB
ROOF LOADS:
TCLL: 20.0 lb/ft²
TCDL: 10.0 lb/ft²
BCLL: 0.0 lb/ft²
BCDL:10.0 lb/ft²
Building Code: IRC 2018
Wind Speed: 115 mph
On-Center Spacing: 24" U.N.O.
2315.75 SF
114.05 LF
212.04 LF
0 LF
80.03 LF
88.28 LF
ROOF DATA
THIS LAYOUT IS INTENDED FOR THE PURPOSE OF TRUSS LOCATION AND PLACEMENT ONLY. REFER TO THE BUILDING PLANS FOR ACTUAL BUILDING CONSTRUCTION.TG129Marin, Indiana 46033ROOF TRUSS PLACEMENT PLANA00048A1850 N Graham RoadFranklin, Indiana 46131Office:(317) 346-4274Fax: (317) 346-0916