HomeMy WebLinkAboutL502 Site DetailsPRECAST PLANTER/SEAT WALL SECTIONScale: 3/4" = 1'-0"Expansion Joint w/Sealant, See DetailsPre-cast Concrete, 28 day compressive strength of 5,000 psi min.Light Sandblast finish all surfaces above grade.1" Radius, typ.VARIES1'-6"VARIESSlope 1/4" per footStructural Reinforcing to bedesigned by precast manufacturer.12" Grout Setting BedTwo (2) 6" SS Dowels atends of each piece.Provide (4) total.Compacted #2 Aggregate, 3" min.2" Compacted #53 Crushed Stone6x6 12 ga WWM Steel Reinforcement4,000 PSI CIP Concrete, 6" thick.DRAWING TITLE:CERTIFIED BY:DRAWING NUMBERPROJECT NUMBERREVISIONS:SCOPE DRAWINGS: These drawings indicate the general scope of the projectin terms of architectural design concept, the dimensions ofthe building, the major architectural elements and the typeof structural, mechanical and electrical systems. The drawings do not necessarily indicate or describe allwork required for full performance and completion of therequirements of the Contract. On the basis of the general scope indicated or described,the trade contractors shall furnish all items required for theproper execution and completion of the work.ISSUE DATEDRAWN BYCHECKED BY10/05/22MAJSPROJECT:
CARMEL MIDTOWN21-1489CARMEL, INNOT FORCONSTRUCTION21-1489L502SITEDETAILSMAJTS03/23/2212BIKE RACK INSTALLATION, SURFACE MOUNTEDScale: 1/2" = 1'-0"Bike RackPLAN4'-0"SECTION: SURFACE MOUNTConcrete Pavement,Refer to Detail 1/L500Bike rack,surface mountConcrete Pavement2' min clear
2' min clear
2'-9"SIDE ELEVATION8'-0"4"4"3'-0"6"WOOD FENCE SECTION8'-0" max. evenly spaced6" gravel baseCompacted subgrade, typ.Finish gradeConcrete foundation, typ. Center the middle braceon the pickets2" x 6" treated wood crossbraceAttach each 2" x 6" crossbrace to the 6" x 6" treatedwood post with (2) 3" x 1/4"galvanized lag bolts withwashersAttach each 1" x 6" woodpicket to each 2" x 6" crossbrace with (2) 2" wood screws1" x 6" cedar wood pickets, sealed6" x 6" treated wood postTop of concrete foundationto be rectangular in shape1/2" slopeInstall 1" x 6" boards verticallyon outside of patio. Space 1" x6" boards equally betweenpost. Picket to align with postSHADOWBOX PRIVACY FENCE (WOOD)Not to Scale6"6"Post shall be evenlyspaced along each run.Provide finial at each post.3Space posts evenlybetween gates atintervals nogreater than 8'-0".15"42"Belled ConcreteFooting, Typ.See spec.4" Max. O.C., Typ.Extruded Aluminum Fencing,black powdercoat finish, includegate 3' wide as shown on layoutplan.Hold top of fence at constant elevation.Cut pickets as required to match grade.·Townhome Fence - 4'-0" min. heightORNAMENTAL METAL FENCE Scale: 1/2"=1'-0"NOTES:1.Fence Contractor shall be responsible for verifying size of foundations and o.c.spacing and length of posts prior to fabrication. Refer to Specifications.2.Contractor to submit full shop drawings for approval by Landscape Architect priorto fabrication.3.Contractor shall coordinate, furnish, and install all hardware, brackets, supports,and anchors to provide a complete fencing system.4.Miter cut, weld clean, and grind smooth all visible metal connections. all materialshall be black powdercoat finish.18"Provide Kickplate. Door SurfacesWithin 10" of the Floor, MeasuredVertically, Shall be Smooth Surface onthe Push Side of the Door. PartsCreating Horizontal or Vertical Joints inThis Surface Shall be Within 1/16" ofthe Same Plane as the Other. CavitiesCreated by Added Kickplates Shall beCapped.4'-0"3" Max.4NOTE: The ramp types shown in this detail is aPrototypical Configuration. Minor adjustments maybe required to accommodate specific fieldconditions. Coordinate adjustments and alterationsin the field with the Landscape Architect. Ensurethat positive drainage is maintained on and aroundthe ramp to prevent birdbaths and ponding.Adjacent Paving, Refer to Materials PlansRamp Face, Running Slope 8.33%Max., Cross Slope 1.5% Max.Crosswalk Striping, Refer to Project SpecificationsWidth of Ramp FaceClear Space, 4'-0" x 4'-0" Min. Typ.Turning Space, 4'-0" x 4'-0" Min.Detectable Warning Surface, Refer toProject Specifications for MaterialMin. Width 2'-0"Return CurbPROTOTYPICAL ONE-WAY DIRECTIONAL PERPENDICULAR CURB RAMPScale: 1/4" = 1'-0"5NOTE: The ramp type shown in this detail is aPrototypical Configuration. Minor adjustments maybe required to accommodate specific fieldconditions. Coordinate adjustments and alterationsin the field with the Landscape Architect. Ensurethat positive drainage is maintained on and aroundthe ramp to prevent birdbaths and ponding.Adjacent Paving, Refer to Materials PlansRamp Face, Running Slope 8.33%Max., Cross Slope 1.5% Max.Crosswalk Striping, Refer to Project SpecificationsWidth of Ramp Face4'-0"Return CurbClear Space, 4'-0" x 4'-0" Typ.Turning Space, 4'-0" x 4'-0" Min.Detectable Warning Surface, Refer toProject Specifications for MaterialMin. Width 2'-0"Flared Side, RunningSlope 10.0% Max.PROTOTYPICAL PERPENDICULAR CURB RAMP WITH FLARE AND CURBScale: 1/4" = 1'-0"67TYPICAL CATENARY POSTScale: 3/4" = 1'-0"Non-Shrink Grout BedReinforced Cast-in-Place Concrete Footing,Design per Structural EngineerFinish GradeSST Bolt Set, Sizing per Structural Engineer9"Fully Welded Steel Cap with Positive Slopeto Drain4" Sq. Steel Catenary Post w/ Base Plate,Powdercoat Finish - BlackConduit with Electrical Connections; Ref:MEP DrawingsHeavy Duty Steel I-Bolt. coordinate finalsize and tensioning requirements w/Structural EngineerThreaded Hub for String Light Wiring andAluminum Liquid Tight Cordgrip, 3/4" NPT,0.375-inch to 0.438-inch Diameter Cablecapacity. HEYCO M50331/8" SS Catenary Cable, Installed with 12"Max. Sag after all Equipment has beenAttachedAnchor Catenary Cable to Heavy Duty I-Boltwith Heavy Duty Cable LockCatenary String Lighting , wet rated bulbsw/ LED Lamps, secured to Catenary Cableper manufacturer's instructionsShroud Base Cover, match Material andFinish of Post, provide continuousWaterproof Sealant along top of ShroudBase Plate, See Detail BelowRefer to Structural
Engineer's Drawings10"Refer toStructuralEngineer'sDrawings10"4" Sq. Steel Catenary Post, PowdercoatFinish - Black, Welded to Base Plate3/16" PL Steel Base Plate, PowdercoatFinish - Black3/16" PL Steel Gusset, Welded to Post andBase PlateExtents of Shroud Base CoverNOTE:1.DRAWINGS SHOWN ARE INTENT DRAWINGS ONLY. Contractor Shall provide StructuralDrawings, stamped by a licensed Structural Engineer in the State of Indiana, as delegated designfor all detailing, connections, structural members, footings, reinforcing, cable sizing and cablehardware.2.All metal structural components shall be properly prepared and powdercoated black for aconsistent, even finish capable of long lasting, durable performance. 7 Mil. thickness minimum.1"