HomeMy WebLinkAboutM004.0 - Truss LayoutBM1BM2
23-05-0010-03-00 15-00-00 9-04-00
2-00-00
60-00-008-00-00 21-08-0030-04-0060-00-002-10-00 12-08-00 20-04-00
35-10-002-00-008-04-00 17-08-00 7-10-00
35-10-00
LAY1
LAY2
LAY3
LAY4
LAY4
E1
E2
E3
E3
A1
J7J3J3J3J3J3J4J5J6A2
A3
A4
A5
A6
A6
A6
A6
A6
A7
A8A9
B1
B2
B3C1C2C2C2C2
C3C4B3
B3
B3
B3
B4
B5
B6
B6
M1M2M2M2M2M2M2M1D1D2J8
J9
J3
J3
J3
J3
J8
J9
J3
J10J10J10J10J11J
12M3M4M4M4M4M4M4M4M4M5M6M7M8M9J2
J2
J2
J2J1
V4V3V2V3A
V2A
V1IMPORTANT
THIS DRAWING IS FOR FIELD PLACEMENT OF INDIVIDUAL
COMPONENTS ONLY, AND DOES NOT CONSTITUTE AN
ENGINEERED DOCUMENT.
NOTE
PROPER BEARING AND BEARING DESIGN INCLUDING
ANCHORAGE, IS THE RESPONSIBILITY OF THE BUILDING
DESIGNER, ARCHITECT AND / OR BUILDING ENGINEER. REFER
TO INDIVIDUAL TRUSS DESIGNS FOR REACTIONS, MINIMUM
REQUIRED BEARING SIZE, UPLIFT, AND ADDITIONAL LOADS.
84 COMPONENTS DOES NOT ASSUME RESPONSIBILITY IN
THESE AREAS OF CONCERN.
BRACING
ERECTION, TEMPORARY, AND PERMANENT BRACING IS THE
RESPONSIBILITY OF THE CONTRACTOR AND / OR BUILDING
DESIGNER. REFER TO INDIVIDUAL TRUSS DESIGNS FOR
ADDITIONAL BRACING REQUIREMENTS. REFER TO BCSI-B1
SUMMARY SHEET. THE STRUCTURAL BUILDING COMPONENTS
ASSOCIATION COMMENTARY, AND RECOMMENDATIONS FOR
HANDLING, INSTALLING & BRACING METAL PLATE CONNECTED
WOOD TRUSSES.www.sbcindustry.com
INSTALLATION
DO NOT CUT, DRILL, OR ALTER TRUSSES. ANY QUESTIONS
CALL 84 COMPONENTS. PROPER INSTALLATION, AND
HANDLING OF COMPONENTS IS THE RESPONSIBILITY OF THE
ERECTING CONTRACTOR. 84 COMPONENTS MUST BE
NOTIFIED OF ANY PROBLEMS, AND AFFORDED THE
OPPORTUNITY TO REVIEW, AND MAKE NECESSARY
CORRECTIONS, OR NO BACK CHARGES WILL BE ACCEPTED
OR APPROVED.
WARNING
WARNINGS, AND INSTRUCTIONS FOR ERECTION
OF COMPONENTS ARE INCLUDED IN THE DELIVERY PACKAGE.
KEEP THIS INFORMATION ON THE JOB SITE. THESE
DOCUMENTS WILL ALSO BE NEEDED FOR JOB SITE
INSPECTION. MISUSE AND IMPROPER INSTALLATION OF
COMPONENTS MAY RESULT IN FAILURE, BODILY INJURY, LOSS
OF PROPERTY, AND / OR LIFE.
Roof Area:
Overhang Length:
Eave Length:
Hip Length:
Valley Length:
Ridge Length:
SHEET NUMBER:
R1.1
Roof Truss
Placement Plan
SCALE: NTS
Job#:
PO#:
Date: 9/20/2022
Drawn By: MB
Designed By: MB
Checked By:
ROOF LOADS:
TCLL: 20.0 lb/ft²
TCDL: 10.0 lb/ft²
BCLL: 0.0 lb/ft²
BCDL:10.0 lb/ft²
Building Code: IRC 2018
Wind Speed: 115 mph
On-Center Spacing: 24" U.N.O.
2299.63 SF
216.5 LF
87.57 LF
89.93 LF
41.56 LF
57.72 LF
ROOF DATA
THIS LAYOUT IS INTENDED FOR THE PURPOSE OF TRUSS LOCATION AND PLACEMENT ONLY. REFER TO THE BUILDING PLANS FOR ACTUAL BUILDING CONSTRUCTION.TG123,ROOF TRUSS PLACEMENT PLANA00043A1850 N Graham RoadFranklin, Indiana 46131Office:(317) 346-4274Fax: (317) 346-0916
14 - HUS26
1 - HGUS26-2
100 - RT7A