HomeMy WebLinkAboutNEZ AD3.series-Fire Rated Details-AD3.0-2 2x4\A1;{\W0.7;PER PLAN} (2) 2" 'C' CHANNELS PER ASSEMBLY, INSTALL PER MFR. INSTRUCTIONS\A1;1/2" DRYWALL PER SPEC. ENG. ROOF TRUSSES, TYP. (2) 1" GYP. BOARD SHAFT LINER PANELS PER ASSEMBLYATTIC INSULATION PER ENERGY CALC'S., TYP. PROVIDE FIRE-RETARDANT-TREATED PLYWOOD SHEATHING MIN. 48" EACH SIDE CENTERLINE OF FIRE SEPARATION WALL 2x4 STUDS PER STRUC. 2 HOUR RATED ASSEMBLY GA WP 1955 (44'-68") \A1; 1" AIRSPACE (EA. SIDE) \A1;DRYWALL PER ASSEMBLY\A1;DRYWALL PER ASSEMBLY \A1;1/2" DRYWALL PER SPEC. \A1; ATTACHMENT CLIP PER ASSEMBLY, INSTALL PER MFR. INSTRUCTIONSFIREBLOCKING PER CODE, TYP. 2" 'C' CHANNEL PER ASSEMBLY, INSTALL PER MFR. INSTRUCTIONS \A1;EXTERIOR FINISH PER SPEC. OVER \P5/8" DENSGLASS FIREGUARD SHEATHING PER ASSEMBLY\POVER PLYWOOD SHEATHING \A1; 1 HOUR RATED ASSEMBLY UL#U338 \A1;{\L\C6;NOTE\l:}\P\pxsm0.85;{\A0;NO PENETRATIONS WITHIN 4 FT. OF CENTER LINE (EACH SIDE) IN FIRE-RETARDANT-TREATED PLYWOOD SHEATHING, TYP. }\A1;6"2x BLOCKING TO FOLLOW ADJACENT ROOF PLANE, MIN. 6" BELOW ADJACENT ROOF SHEATHING PROVIDE FIRE-RETARDANT-TREATED PLYWOOD SHEATHING MIN. 48" EACH SIDE CENTERLINE OF FIRE SEPARATION WALLROOF SHINGLES PER SPEC,\PMIN. CLASS C ROOF COVERING. ROOF SHINGLES PER SPEC,\PMIN. CLASS C ROOF COVERING. \A1; \A1;INSULATION PER ENERGY CALC'S., TYP. 2 HOUR RATED ASSEMBLY\PUL#U373 (44') / UL#347 (66') / UL#336 (66') /\PWHI GP/WA#120-04 (68') 2 HOUR RATED ASSEMBLY\PUL#U373 (44') / UL#347 (66') / UL#336 (66') /\PWHI GP/WA#120-03 (44'-68') \A1;5/8" GYP. BD. PER\PUL #338 AT INTERIOR SIDE OF {\A0;GABLE END TRUSS} \A1;9'-3 1/8" \A1;{\W0.7;PER PLAN} \A1;{\W0.7;FLOOR SYSTEM\P{\W0.7;PER STRUCTURAL}} ATTACHMENT CLIP PER ASSEMBLY, INSTALL PER MFR. INSTRUCTIONS ATTACHMENT CLIP PER ASSEMBLY, INSTALL PER MFR. INSTRUCTIONS, TYP. FIREBLOCKING PER CODE\A1; \A1; \A1;1/2" DRYWALL PER SPEC. T&G FLOOR SHEATHING, GLUE PER SPEC. & ATTACH PER STRUC., TYP.BASE TRIM PER SPEC, TYP.CONT. AIR BARRIER SEALANT, TYP.INSULATION PER ENERGY CALC'S., TYP. 2x RIBBON W/ OPEN WEB TRUSSED (TYP.), REF. STRUC.RIM. BD. PER STRUC. (TYP.) 2 HOUR RATED ASSEMBLY\PUL#U373 (44') / UL#347 (66') / UL#336 (66') /\PWHI GP/WA#120-04 (68') 2 HOUR RATED ASSEMBLY\PUL#U373 (44') / UL#347 (66') / UL#336 (66') /\PWHI GP/WA#120-04 (68') STEPPED 2-HOUR FIRE SEPARATION WALL \A1;{\W0.7;PER PLAN} \A1;{\W0.7;PER STRUC.} CONT. CAULK BEAD{\L\C6;INTERIOR} \A1; 2" 'C' CHANNEL PER ASSEMBLY, INSTALL PER MFR. INSTRUCTIONS ANCHORAGE PER STRUCTURAL DETAILS {\C6;NOTE:\P}FIRE-RESISTANCE-RATED WALL ASSEMBLIES ARE REQUIRED TO EXTEND FROM THE FOUNDATION TO THE UNDERSIDE OF THE ROOF FOR UNIT SEPARATIONS. {\L\C6;INTERIOR}TREATED SILL PLATE OVER SILL SEALER. ANCHORAGE PER STRUC., TYP. 2 HOUR RATED ASSEMBLY\PUL#U373 (44') / UL#347 (66') / UL#336 (66') /\PWHI GP/WA#120-04 (68')CONT. CAULK BEAD, TYP.{\L\C6;GARAGE} CONCRETE FOOTING PER STRUCTURAL PLANS \A1; {\L\C6;GARAGE} ANCHORAGE PER STRUCTURAL DETAILS, TYP. 2" 'C' CHANNEL PER ASSEMBLY, INSTALL MFR. INSTRUCTIONS CONC. FOUNDATION WALL PER STRUC. \A1;CONCRETE SLAB OVER VAPOR BARRIER (AS REQUIRED), TYP. {\C6;NOTE:\P}FIRE-RESISTANCE-RATED WALL ASSEMBLIES ARE REQUIRED TO EXTEND FROM THE FOUNDATION TO THE UNDERSIDE OF THE ROOF FOR UNIT SEPARATIONS. 2 HOUR RATED ASSEMBLY\PUL#U373 (44') / UL#347 (66') / UL#336 (66') /\PWHI GP/WA#120-04 (68') ATTACHMENT CLIP PER ASSEMBLY, INSTALL PER MFR. INSTRUCTIONS RAKE PER SPEC. FLASHING PER ROOF DETAILS \A1; \A1; 1 HOUR RATED ASSEMBLY UL#U338 PROVIDE FIRE-RETARDANT-TREATED PLYWOOD SHEATHING MIN. 48" EACH SIDE CENTERLINE OF FIRE SEPARATION WALL 2" 'C' CHANNEL PER ASSEMBLY, \PINSTALL PER MFR. INSTRUCTIONS PROVIDE FIRE-RETARDANT-TREATED PLYWOOD SHEATHING MIN. 48" EACH SIDE CENTERLINE OF FIRE SEPARATION WALL ENG. ROOF TRUSSES, TYP.ATTIC INSULATION PER ENERGY CALC'S., TYP. 1" AIRSPACE (EA. SIDE)\A1;DRYWALL PER ASSEMBLY\A1;(2) 2" 'C' CHANNELS PER ASSEMBLY, INSTALL PER MFR. INSTRUCTIONS (2) 1" GYP. BOARD SHAFT LINER PANELS PER ASSEMBLY 2x4 STUDS PER STRUC. \A1;1/2" DRYWALL PER SPEC.\A1;DRYWALL PER ASSEMBLY \A1;EXTERIOR FINISH PER SPEC. OVER \P5/8" DENSGLASS FIREGUARD SHEATHING PER ASSEMBLY\POVER PLYWOOD SHEATHING \A1; 1 HOUR RATED ASSEMBLY\PUL#U344 / UL#U305 / UL#356 \A1;{\L\C6;NOTE\l:}\P\pxsm0.85;{\A0;NO PENETRATIONS WITHIN 4 FT. OF CENTER LINE (EACH SIDE) IN FIRE-RETARDANT-TREATED PLYWOOD SHEATHING, TYP. } \A1;1/2" DRYWALL PER SPEC.\A1;FIRE BLOCKING PER CODE, TYP. ROOF SHINGLES PER SPEC,\PMIN. CLASS C ROOF COVERING. ROOF SHINGLES PER SPEC,\PMIN. CLASS C ROOF COVERING. \A1;INSULATION PER ENERGY CALC'S., TYP. 2 HOUR RATED ASSEMBLY\PUL#U373 (44') / UL#347 (66') / UL#336 (66') /\PWHI GP/WA#120-04 (68') 2 HOUR RATED ASSEMBLY\PUL#U373 (44') / UL#347 (66') / UL#336 (66') /\PWHI GP/WA#120-03 (44'-68') \A1;5/8" GYP. BD. PER\PUL #338 AT INTERIOR SIDE OF {\A0;GABLE END TRUSS} \A1;VARIES CONCRETE FOOTING PER STRUCTURAL PLANS 1/2" DRYWALL PER SPEC. AT FINISHED CONDITION, TYP. CONCRETE FOOTING PER STRUCTURAL PLANS FURRED WALL AT FINISHED CONDITION, TYP. \A1;{\W0.7;PER STRUC.} \A1;{\W0.7;PER PLAN} \A1;{\W0.7;FLOOR SYSTEM\P{\W0.7;PER STRUCTURAL}} \A1;9'-1 1/8" ATTACHMENT CLIP PER ASSEMBLY, INSTALL PER MFR. INSTRUCTIONS, TYP.2x4 STUDS PER SPEC FIREBLOCKING PER CODE 2" 'C' CHANNEL PER ASSEMBLY, INSTALL PER MFR. INSTRUCTIONSANCHORAGE PER STRUCTURAL DETAILS, TYP. \A1; 2x4 STUDS PER STRUC. CONC. FOUNDATION WALL \P(10" MIN., VERIFY w/ STRUC.) INSULATION PER ENERGY CALC'S., TYP.T&G FLOOR SHEATHING, GLUE PER SPEC. & ATTACH PER STRUC., TYP.BASE TRIM PER SPEC, TYP.CONT. AIR BARRIER SEALANT, TYP. {\C6;NOTE:\P}FIRE-RESISTANCE-RATED WALL ASSEMBLIES ARE REQUIRED TO EXTEND FROM THE FOUNDATION TO THE UNDERSIDE OF THE ROOF FOR UNIT SEPARATIONS. {\L\C6;INTERIOR} {\L\C6;INTERIOR} 2x RIBBON W/ OPEN WEB TRUSSED (TYP.), REF. STRUC.RIM. BD. PER STRUC. (TYP.) 2 HOUR RATED ASSEMBLY\PUL#U373 (44') / UL#347 (66') / UL#336 (66') /\PWHI GP/WA#120-04 (68') CONT. CAULK BEAD, TYP.{\L\C6;INTERIOR} CONCRETE FOOTING PER STRUCTURAL PLANS {\L\C6;GARAGE} ANCHORAGE PER STRUCTURAL DETAILS, TYP. 2" 'C' CHANNEL PER ASSEMBLY, INSTALL MFR. INSTRUCTIONS {\C6;NOTE:\P}FIRE-RESISTANCE-RATED WALL ASSEMBLIES ARE REQUIRED TO EXTEND FROM THE FOUNDATION TO THE UNDERSIDE OF THE ROOF FOR UNIT SEPARATIONS. 2" RIGID INSULATION HORIZONTALLY & VERTICALLY TO FOOTING, VERIFY w/ ENERGY CALC'S. 1" RIGID INSULATION, VERIFY w/ ENERGY CALC'S. CONC. FOUNDATION WALL PER STRUC. \A1;CONCRETE SLAB OVER VAPOR BARRIER (AS REQUIRED) 2 HOUR RATED ASSEMBLY\PUL#U373 (44') / UL#347 (66') / UL#336 (66') /\PWHI GP/WA#120-04 (68') PROVIDE FIRE-RETARDANT-TREATED PLYWOOD SHEATHING MIN. 48" EACH SIDE CENTERLINE OF FIRE SEPARATION WALL \A1;DRYWALL PER ASSEMBLY\A1;1/2" DRYWALL PER SPEC. {\W0.85;⅊} \A1; \A1; 2x BLOCKING, TYP.TRUSS BOTTOM CHORD TRUSS TOP CHORD {\L\C6;GARAGE\PINTERIOR}{\L\C6;GARAGE\PINTERIOR} 2 HOUR RATED ASSEMBLY\PUL#U373 (44') / UL#347 (66') / UL#336 (66') /\PWHI GP/WA#120-04 (68') 1" AIRSPACE (EA. SIDE) \A1;DRYWALL PER ASSEMBLY \A1;INSULATION PER ENERGY CALC'S., TYP. 2 HOUR RATED ASSEMBLY GA WP 1955 (44'-68')FIREBLOCKING PER CODE, TYP. \A1;4'-0" MIN.\A1;FIRE-RETARDANT-TREATED PLYWOOD SHEATHING\A1;4'-0" MIN.\A1;FIRE-RETARDANT-TREATED PLYWOOD SHEATHING 2" 'C' CHANNEL PER ASSEMBLY, INSTALL PER MFR. INSTRUCTIONS ATTACHMENT CLIP PER ASSEMBLY, INSTALL PER MFR. INSTRUCTIONS {\C6;NOTE:\P\C4;FIRE-RESISTANCE-RATED WALL ASSEMBLIES ARE REQUIRED TO EXTEND FROM THE FOUNDATION TO THE UNDERSIDE OF THE ROOF FOR UNIT SEPARATIONS.} \A1;{\L\C6;NOTE\l:}\P\pxsm0.85;{\A0;NO PENETRATIONS WITHIN 4 FT. OF CENTER LINE (EACH SIDE) IN FIRE-RETARDANT-TREATED PLYWOOD SHEATHING, TYP. } \A1; 2 HOUR RATED ASSEMBLY\PUL#U373 (44') / UL#347 (66') / UL#336 (66') /\PWHI GP/WA#120-03 (44'-68') \A1; TYPICAL OFFSET EXTERIOR WALL - 2 HR \A1;SHEATHING PER STRUC.\A1;C-TRACK, INSTALL PER MFR. INSTRUCTIONS\A1;EXTERIOR FINISH PER PLAN\A1;5/8" DENSGLASS FIREGUARD SHEATHING PER ASSEMBLY \A1;EXTERIOR FINISH PER PLAN \A1;5/8" DRYWALL PER ASSEMBLY\A1;1/2" DRYWALL PER ASSEMBLY {\L\C6;INTERIOR}\A1;2x4 STUDS PER STRUC.\A1; (2) 1" GYP. BOARD SHAFT LINER PANELS PER ASSEMBLY {\L\C6;INTERIOR}1 HOUR RATED ASSEMBLY\PUL#U344 / UL#U305 / UL#356 \A1; \A1;{\H1x;PLYWOOD SHEATHING PER SPEC.}{\L\C6;EXTERIOR}\A1;2x WALL PER PLAN \A1;ATTACHMENT CLIP PER ASSEMBLY, INSTALL PER MFR. INSTRUCTIONS\A1;H-STUDS PER ASSEMBLY, INSTALL PER MFR. INSTRUCTIONS \A1;11"\A1;1"\A1;1"\A1;3 1/2"\A1;3 1/2"\A1;1"\A1;1"LC {\LNOTE}:\PEXTEND 5/8" TYPE 'X' GYP. BD. FULL LENGTH OF INTERIOR WALL UNTIL INTERSECTION OCCURS\POR\PPROVIDE DRYWALL SHIMS OR ADDITIONAL SKIM COAT COMPOUND TO FLUSH DRYWALL FINISHES 2 HOUR RATED ASSEMBLY\PUL#U373 (44') / UL#347 (66') / UL#336 (66') /\PWHI GP/WA#120-04 (68') SCALE 3/4" = 1'-0"2-HOUR FIRE SEPARATION WALL - SLAB ON GRADE - OFFSET SCALE 3/4" = 1'-0"2-HOUR FIRE SEPARATION WALL - FLOOR/CEILING - INTERMEDIATE FLOORS - OFFSET SCALE 3/4" = 1'-0"2-HOUR FIRE SEPARATION WALL - ROOF/CEILING - INTERSECTING ROOF - OFFSET SCALE 3/4" = 1'-0"2-HOUR FIRE SEPARATION WALL - ROOF/CEILING - ROOF OFFSET 1-HOUR FIRE RATED WALL - WALL ABOVE ROOF SCALE 3/4" = 1'-0"2-HOUR FIRE SEPARATION WALL - INGROUND BASEMENT - OFFSET 1-HOUR FIRE RATED WALL - WALL ABOVE ROOF SCALE 3/4" = 1'-0"2-HOUR FIRE SEPARATION WALL - GARAGE TO GARAGE - OFFSET PLAN NAME SHEET PRODUCTION MANAGERRELEASE DATE:DATE / DESCRIPTION NPC PLAN NUMBERLAWSON PLAN IDLEGACY PLAN NUMBER / NAME REV # NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS CURRENT 05/31/21JL (c) Copyright Pulte Home Corporation - 2014 STD DETAILS150 Allen Rd, Suite 303Basking Ridge, New Jersey 07920Northeast Zone OfficePLOTTED: Aug. 24, 21 / Jeffrey Moskovciak / AD3.0-2 2X4 / C:\\USERS\\JMOSKOVCIAK\\ONEDRIVE - PULTEGROUP\\DESKTOP\\TEMP\\_PUBLISHING\\_TEMP SDP\\2021-05-31 (WIP DO NOT USE)\\NEZ STANDARD DETAIL SHEETS\\BASE FILES (DO NOT MODIFY)\\NEZ AD3.SERIES-FIRE RATED DETAILS.DWGFirewall Sections @ Unit Separation withFoundation / Floor / Ceiling OffsetsAD3.0-22HR FIRE SEPARATION WALL SECTIONS (VERTICAL OFFSET)SCALE :3/4" = 1'-0"A SCALE :3/4" = 1'-0"B SCALE 3/4" = 1'-0"2-HOUR FIRE SEPARATION WALL - GARAGE TO INTERIOR - OFFSET \A1;CONCRETE SLAB OVER VAPOR BARRIER {\L\O\C7;(PER 2009, 2012, 2015, 2018 IRC R506.2.3)} OVER APPROVED BASE PER STRUC. \A1;CONCRETE SLAB OVER VAPOR BARRIER {\L\O\C7;(PER 2009, 2012, 2015, 2018 IRC R506.2.3)} OVER APPROVED BASE PER STRUC. \A1;CONCRETE SLAB OVER VAPOR BARRIER {\L\O\C7;(PER 2009, 2012, 2015, 2018 IRC R506.2.3)} OVER APPROVED BASE PER STRUC. 1 2 3 4 5 6 7SCALE 3/4" = 1'-0"UNIT SEPARATION WALL AT ROOF GABLE CONDITION OVER GARAGE8 TERMINATION EXTERIOR WALL (OFFSET) 2-HOUR FIRE SEPARATION PLAN - 10/10/22