HomeMy WebLinkAboutNEZ AD3.series-Fire Rated Details-AD3.0-2 2x4\A1;{\W0.7;PER PLAN}
(2) 2" 'C' CHANNELS PER ASSEMBLY, INSTALL PER MFR. INSTRUCTIONS\A1;1/2" DRYWALL PER SPEC.
ENG. ROOF TRUSSES, TYP.
(2) 1" GYP. BOARD SHAFT LINER PANELS PER ASSEMBLYATTIC INSULATION PER ENERGY CALC'S., TYP.
PROVIDE FIRE-RETARDANT-TREATED PLYWOOD SHEATHING MIN. 48" EACH SIDE CENTERLINE OF FIRE SEPARATION WALL
2x4 STUDS PER STRUC.
2 HOUR RATED ASSEMBLY GA WP 1955 (44'-68")
\A1;
1" AIRSPACE (EA. SIDE)
\A1;DRYWALL PER ASSEMBLY\A1;DRYWALL PER ASSEMBLY
\A1;1/2" DRYWALL PER SPEC.
\A1;
ATTACHMENT CLIP PER ASSEMBLY, INSTALL PER MFR. INSTRUCTIONSFIREBLOCKING PER CODE, TYP.
2" 'C' CHANNEL PER ASSEMBLY, INSTALL PER MFR. INSTRUCTIONS
\A1;EXTERIOR FINISH PER SPEC. OVER \P5/8" DENSGLASS FIREGUARD SHEATHING PER ASSEMBLY\POVER PLYWOOD SHEATHING
\A1; 1 HOUR RATED ASSEMBLY UL#U338
\A1;{\L\C6;NOTE\l:}\P\pxsm0.85;{\A0;NO PENETRATIONS WITHIN 4 FT. OF CENTER LINE (EACH SIDE) IN FIRE-RETARDANT-TREATED PLYWOOD SHEATHING, TYP. }\A1;6"2x BLOCKING TO FOLLOW ADJACENT ROOF PLANE, MIN. 6" BELOW ADJACENT ROOF SHEATHING
PROVIDE FIRE-RETARDANT-TREATED PLYWOOD SHEATHING MIN. 48" EACH SIDE CENTERLINE OF FIRE SEPARATION WALLROOF SHINGLES PER SPEC,\PMIN. CLASS C ROOF COVERING.
ROOF SHINGLES PER SPEC,\PMIN. CLASS C ROOF COVERING.
\A1;
\A1;INSULATION PER ENERGY CALC'S., TYP.
2 HOUR RATED ASSEMBLY\PUL#U373 (44') / UL#347 (66') / UL#336 (66') /\PWHI GP/WA#120-04 (68')
2 HOUR RATED ASSEMBLY\PUL#U373 (44') / UL#347 (66') / UL#336 (66') /\PWHI GP/WA#120-03 (44'-68')
\A1;5/8" GYP. BD. PER\PUL #338 AT INTERIOR SIDE OF {\A0;GABLE END TRUSS}
\A1;9'-3 1/8"
\A1;{\W0.7;PER PLAN}
\A1;{\W0.7;FLOOR SYSTEM\P{\W0.7;PER STRUCTURAL}}
ATTACHMENT CLIP PER ASSEMBLY, INSTALL PER MFR. INSTRUCTIONS
ATTACHMENT CLIP PER ASSEMBLY, INSTALL PER MFR. INSTRUCTIONS, TYP.
FIREBLOCKING PER CODE\A1;
\A1; \A1;1/2" DRYWALL PER SPEC.
T&G FLOOR SHEATHING, GLUE PER SPEC. & ATTACH PER STRUC., TYP.BASE TRIM PER SPEC, TYP.CONT. AIR BARRIER SEALANT, TYP.INSULATION PER ENERGY CALC'S., TYP.
2x RIBBON W/ OPEN WEB TRUSSED (TYP.), REF. STRUC.RIM. BD. PER STRUC. (TYP.)
2 HOUR RATED ASSEMBLY\PUL#U373 (44') / UL#347 (66') / UL#336 (66') /\PWHI GP/WA#120-04 (68')
2 HOUR RATED ASSEMBLY\PUL#U373 (44') / UL#347 (66') / UL#336 (66') /\PWHI GP/WA#120-04 (68')
STEPPED 2-HOUR FIRE SEPARATION WALL
\A1;{\W0.7;PER PLAN}
\A1;{\W0.7;PER STRUC.}
CONT. CAULK BEAD{\L\C6;INTERIOR}
\A1;
2" 'C' CHANNEL PER ASSEMBLY, INSTALL PER MFR. INSTRUCTIONS
ANCHORAGE PER STRUCTURAL DETAILS
{\C6;NOTE:\P}FIRE-RESISTANCE-RATED WALL ASSEMBLIES ARE REQUIRED TO EXTEND FROM THE FOUNDATION TO THE UNDERSIDE OF THE ROOF FOR UNIT SEPARATIONS.
{\L\C6;INTERIOR}TREATED SILL PLATE OVER SILL SEALER. ANCHORAGE PER STRUC., TYP.
2 HOUR RATED ASSEMBLY\PUL#U373 (44') / UL#347 (66') / UL#336 (66') /\PWHI GP/WA#120-04 (68')CONT. CAULK BEAD, TYP.{\L\C6;GARAGE}
CONCRETE FOOTING PER STRUCTURAL PLANS
\A1;
{\L\C6;GARAGE}
ANCHORAGE PER STRUCTURAL DETAILS, TYP.
2" 'C' CHANNEL PER ASSEMBLY, INSTALL MFR. INSTRUCTIONS
CONC. FOUNDATION WALL PER STRUC.
\A1;CONCRETE SLAB OVER VAPOR BARRIER (AS REQUIRED), TYP.
{\C6;NOTE:\P}FIRE-RESISTANCE-RATED WALL ASSEMBLIES ARE REQUIRED TO EXTEND FROM THE FOUNDATION TO THE UNDERSIDE OF THE ROOF FOR UNIT SEPARATIONS.
2 HOUR RATED ASSEMBLY\PUL#U373 (44') / UL#347 (66') / UL#336 (66') /\PWHI GP/WA#120-04 (68')
ATTACHMENT CLIP PER ASSEMBLY, INSTALL PER MFR. INSTRUCTIONS
RAKE PER SPEC.
FLASHING PER ROOF DETAILS
\A1;
\A1;
1 HOUR RATED ASSEMBLY UL#U338
PROVIDE FIRE-RETARDANT-TREATED PLYWOOD SHEATHING MIN. 48" EACH SIDE CENTERLINE OF FIRE SEPARATION WALL
2" 'C' CHANNEL PER ASSEMBLY, \PINSTALL PER MFR. INSTRUCTIONS
PROVIDE FIRE-RETARDANT-TREATED PLYWOOD SHEATHING MIN. 48" EACH SIDE CENTERLINE OF FIRE SEPARATION WALL
ENG. ROOF TRUSSES, TYP.ATTIC INSULATION PER ENERGY CALC'S., TYP.
1" AIRSPACE (EA. SIDE)\A1;DRYWALL PER ASSEMBLY\A1;(2) 2" 'C' CHANNELS PER ASSEMBLY, INSTALL PER MFR. INSTRUCTIONS
(2) 1" GYP. BOARD SHAFT LINER PANELS PER ASSEMBLY
2x4 STUDS PER STRUC.
\A1;1/2" DRYWALL PER SPEC.\A1;DRYWALL PER ASSEMBLY
\A1;EXTERIOR FINISH PER SPEC. OVER \P5/8" DENSGLASS FIREGUARD SHEATHING PER ASSEMBLY\POVER PLYWOOD SHEATHING
\A1;
1 HOUR RATED ASSEMBLY\PUL#U344 / UL#U305 / UL#356
\A1;{\L\C6;NOTE\l:}\P\pxsm0.85;{\A0;NO PENETRATIONS WITHIN 4 FT. OF CENTER LINE (EACH SIDE) IN FIRE-RETARDANT-TREATED PLYWOOD SHEATHING, TYP. }
\A1;1/2" DRYWALL PER SPEC.\A1;FIRE BLOCKING PER CODE, TYP.
ROOF SHINGLES PER SPEC,\PMIN. CLASS C ROOF COVERING.
ROOF SHINGLES PER SPEC,\PMIN. CLASS C ROOF COVERING.
\A1;INSULATION PER ENERGY CALC'S., TYP.
2 HOUR RATED ASSEMBLY\PUL#U373 (44') / UL#347 (66') / UL#336 (66') /\PWHI GP/WA#120-04 (68')
2 HOUR RATED ASSEMBLY\PUL#U373 (44') / UL#347 (66') / UL#336 (66') /\PWHI GP/WA#120-03 (44'-68')
\A1;5/8" GYP. BD. PER\PUL #338 AT INTERIOR SIDE OF {\A0;GABLE END TRUSS}
\A1;VARIES
CONCRETE FOOTING PER STRUCTURAL PLANS
1/2" DRYWALL PER SPEC. AT FINISHED CONDITION, TYP.
CONCRETE FOOTING PER STRUCTURAL PLANS
FURRED WALL AT FINISHED CONDITION, TYP.
\A1;{\W0.7;PER STRUC.}
\A1;{\W0.7;PER PLAN}
\A1;{\W0.7;FLOOR SYSTEM\P{\W0.7;PER STRUCTURAL}}
\A1;9'-1 1/8"
ATTACHMENT CLIP PER ASSEMBLY, INSTALL PER MFR. INSTRUCTIONS, TYP.2x4 STUDS PER SPEC
FIREBLOCKING PER CODE
2" 'C' CHANNEL PER ASSEMBLY, INSTALL PER MFR. INSTRUCTIONSANCHORAGE PER STRUCTURAL DETAILS, TYP.
\A1;
2x4 STUDS PER STRUC.
CONC. FOUNDATION WALL \P(10" MIN., VERIFY w/ STRUC.)
INSULATION PER ENERGY CALC'S., TYP.T&G FLOOR SHEATHING, GLUE PER SPEC. & ATTACH PER STRUC., TYP.BASE TRIM PER SPEC, TYP.CONT. AIR BARRIER SEALANT, TYP.
{\C6;NOTE:\P}FIRE-RESISTANCE-RATED WALL ASSEMBLIES ARE REQUIRED TO EXTEND FROM THE FOUNDATION TO THE UNDERSIDE OF THE ROOF FOR UNIT SEPARATIONS.
{\L\C6;INTERIOR}
{\L\C6;INTERIOR}
2x RIBBON W/ OPEN WEB TRUSSED (TYP.), REF. STRUC.RIM. BD. PER STRUC. (TYP.)
2 HOUR RATED ASSEMBLY\PUL#U373 (44') / UL#347 (66') / UL#336 (66') /\PWHI GP/WA#120-04 (68')
CONT. CAULK BEAD, TYP.{\L\C6;INTERIOR}
CONCRETE FOOTING PER STRUCTURAL PLANS
{\L\C6;GARAGE}
ANCHORAGE PER STRUCTURAL DETAILS, TYP.
2" 'C' CHANNEL PER ASSEMBLY, INSTALL MFR. INSTRUCTIONS
{\C6;NOTE:\P}FIRE-RESISTANCE-RATED WALL ASSEMBLIES ARE REQUIRED TO EXTEND FROM THE FOUNDATION TO THE UNDERSIDE OF THE ROOF FOR UNIT SEPARATIONS.
2" RIGID INSULATION HORIZONTALLY & VERTICALLY TO FOOTING, VERIFY w/ ENERGY CALC'S.
1" RIGID INSULATION, VERIFY w/ ENERGY CALC'S.
CONC. FOUNDATION WALL PER STRUC.
\A1;CONCRETE SLAB OVER VAPOR BARRIER (AS REQUIRED)
2 HOUR RATED ASSEMBLY\PUL#U373 (44') / UL#347 (66') / UL#336 (66') /\PWHI GP/WA#120-04 (68')
PROVIDE FIRE-RETARDANT-TREATED PLYWOOD SHEATHING MIN. 48" EACH SIDE CENTERLINE OF FIRE SEPARATION WALL
\A1;DRYWALL PER ASSEMBLY\A1;1/2" DRYWALL PER SPEC.
{\W0.85;⅊}
\A1;
\A1;
2x BLOCKING, TYP.TRUSS BOTTOM CHORD
TRUSS TOP CHORD
{\L\C6;GARAGE\PINTERIOR}{\L\C6;GARAGE\PINTERIOR}
2 HOUR RATED ASSEMBLY\PUL#U373 (44') / UL#347 (66') / UL#336 (66') /\PWHI GP/WA#120-04 (68')
1" AIRSPACE (EA. SIDE)
\A1;DRYWALL PER ASSEMBLY
\A1;INSULATION PER ENERGY CALC'S., TYP.
2 HOUR RATED ASSEMBLY GA WP 1955 (44'-68')FIREBLOCKING PER CODE, TYP.
\A1;4'-0" MIN.\A1;FIRE-RETARDANT-TREATED PLYWOOD SHEATHING\A1;4'-0" MIN.\A1;FIRE-RETARDANT-TREATED PLYWOOD SHEATHING
2" 'C' CHANNEL PER ASSEMBLY, INSTALL PER MFR. INSTRUCTIONS
ATTACHMENT CLIP PER ASSEMBLY, INSTALL PER MFR. INSTRUCTIONS
{\C6;NOTE:\P\C4;FIRE-RESISTANCE-RATED WALL ASSEMBLIES ARE REQUIRED TO EXTEND FROM THE FOUNDATION TO THE UNDERSIDE OF THE ROOF FOR UNIT SEPARATIONS.}
\A1;{\L\C6;NOTE\l:}\P\pxsm0.85;{\A0;NO PENETRATIONS WITHIN 4 FT. OF CENTER LINE (EACH SIDE) IN FIRE-RETARDANT-TREATED PLYWOOD SHEATHING, TYP. }
\A1;
2 HOUR RATED ASSEMBLY\PUL#U373 (44') / UL#347 (66') / UL#336 (66') /\PWHI GP/WA#120-03 (44'-68')
\A1;
TYPICAL OFFSET EXTERIOR WALL - 2 HR
\A1;SHEATHING PER STRUC.\A1;C-TRACK, INSTALL PER MFR. INSTRUCTIONS\A1;EXTERIOR FINISH PER PLAN\A1;5/8" DENSGLASS FIREGUARD SHEATHING PER ASSEMBLY
\A1;EXTERIOR FINISH PER PLAN
\A1;5/8" DRYWALL PER ASSEMBLY\A1;1/2" DRYWALL PER ASSEMBLY
{\L\C6;INTERIOR}\A1;2x4 STUDS PER STRUC.\A1;
(2) 1" GYP. BOARD SHAFT LINER PANELS PER ASSEMBLY
{\L\C6;INTERIOR}1 HOUR RATED ASSEMBLY\PUL#U344 / UL#U305 / UL#356
\A1;
\A1;{\H1x;PLYWOOD SHEATHING PER SPEC.}{\L\C6;EXTERIOR}\A1;2x WALL PER PLAN
\A1;ATTACHMENT CLIP PER ASSEMBLY, INSTALL PER MFR. INSTRUCTIONS\A1;H-STUDS PER ASSEMBLY, INSTALL PER MFR. INSTRUCTIONS
\A1;11"\A1;1"\A1;1"\A1;3 1/2"\A1;3 1/2"\A1;1"\A1;1"LC
{\LNOTE}:\PEXTEND 5/8" TYPE 'X' GYP. BD. FULL LENGTH OF INTERIOR WALL UNTIL INTERSECTION OCCURS\POR\PPROVIDE DRYWALL SHIMS OR ADDITIONAL SKIM COAT COMPOUND TO FLUSH DRYWALL FINISHES
2 HOUR RATED ASSEMBLY\PUL#U373 (44') / UL#347 (66') / UL#336 (66') /\PWHI GP/WA#120-04 (68')
SCALE 3/4" = 1'-0"2-HOUR FIRE SEPARATION WALL - SLAB ON GRADE - OFFSET
SCALE 3/4" = 1'-0"2-HOUR FIRE SEPARATION WALL - FLOOR/CEILING - INTERMEDIATE FLOORS - OFFSET
SCALE 3/4" = 1'-0"2-HOUR FIRE SEPARATION WALL - ROOF/CEILING - INTERSECTING ROOF - OFFSET
SCALE 3/4" = 1'-0"2-HOUR FIRE SEPARATION WALL - ROOF/CEILING - ROOF OFFSET
1-HOUR FIRE RATED WALL - WALL ABOVE ROOF
SCALE 3/4" = 1'-0"2-HOUR FIRE SEPARATION WALL - INGROUND BASEMENT - OFFSET
1-HOUR FIRE RATED WALL - WALL ABOVE ROOF
SCALE 3/4" = 1'-0"2-HOUR FIRE SEPARATION WALL - GARAGE TO GARAGE - OFFSET
PLAN NAME
SHEET
PRODUCTION MANAGERRELEASE DATE:DATE / DESCRIPTION
NPC PLAN NUMBERLAWSON PLAN IDLEGACY PLAN NUMBER / NAME
REV #
NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS
CURRENT 05/31/21JL
(c) Copyright Pulte Home Corporation - 2014
STD DETAILS150 Allen Rd, Suite 303Basking Ridge, New Jersey 07920Northeast Zone OfficePLOTTED: Aug. 24, 21 / Jeffrey Moskovciak / AD3.0-2 2X4 / C:\\USERS\\JMOSKOVCIAK\\ONEDRIVE - PULTEGROUP\\DESKTOP\\TEMP\\_PUBLISHING\\_TEMP SDP\\2021-05-31 (WIP DO NOT USE)\\NEZ STANDARD DETAIL SHEETS\\BASE FILES (DO NOT MODIFY)\\NEZ AD3.SERIES-FIRE RATED DETAILS.DWGFirewall Sections @ Unit Separation withFoundation / Floor / Ceiling OffsetsAD3.0-22HR FIRE SEPARATION WALL SECTIONS (VERTICAL OFFSET)SCALE :3/4" = 1'-0"A
SCALE :3/4" = 1'-0"B
SCALE 3/4" = 1'-0"2-HOUR FIRE SEPARATION WALL - GARAGE TO INTERIOR - OFFSET
\A1;CONCRETE SLAB OVER VAPOR BARRIER {\L\O\C7;(PER 2009, 2012, 2015, 2018 IRC R506.2.3)} OVER APPROVED BASE PER STRUC.
\A1;CONCRETE SLAB OVER VAPOR BARRIER {\L\O\C7;(PER 2009, 2012, 2015, 2018 IRC R506.2.3)} OVER APPROVED BASE PER STRUC.
\A1;CONCRETE SLAB OVER VAPOR BARRIER {\L\O\C7;(PER 2009, 2012, 2015, 2018 IRC R506.2.3)} OVER APPROVED BASE PER STRUC.
1 2 3 4
5
6
7SCALE 3/4" = 1'-0"UNIT SEPARATION WALL AT ROOF GABLE CONDITION OVER GARAGE8
TERMINATION EXTERIOR WALL (OFFSET)
2-HOUR FIRE SEPARATION PLAN -
10/10/22