HomeMy WebLinkAboutNEZ AD3.series-Fire Rated Details-AD3.8 2015_2018\A1;5/8" TYPE "X" DRYWALL PER SPEC.
\A1;2x_ FIRE BLOCKING IN ROOF OVERHANG (CUT TO SEAL TIGHT), AS REQUIRED\A1;{\H1x;GABLE END OR EAVE OVERHANG CONDITION (SHOWN HATCHED) PER 1-HR RATED WALL SECTIONS (THIS SHEET)}\A1;LINE OF ROOF OVERHANG
OR ROOF RETURN
\A1;LINE OF ROOF OVERHANG OR GABLE EXTENSION
FIRE BLOCKING AT ROOF TYP. OFFSET EXT. WALL - 1 HRSCALE 3/4" = 1'-0"
\A1;{\L\C6;NOTE\l:}\P\pxsm0.85;{\A0;REFER TO OFFSET DETAILS ON SHEET AD3.0}
1 HOUR RATED ASSEMBLY\PUL#U305\PUL#U344\PUL#U356
\A1;
9
DRAINAGE PLANE BEHIND SIDINGDRAINAGE PLANE BEHIND SIDING
RIM BOARD PER STRUC.
SLAB ON GRADE / GARAGE FOUNDATION
SHEATHING PER STRUC.
FINISHED GRADE
SHEATHING PER STRUC.
DRAINAGE PLAINSIDING PER MANUFACTURERS\PSPECIFICATIONS
SCALE: 2-1/2" = 1'-0"FLASHING DETAIL
1 LAYER OF 5/8" GYP. BD., PER ASSEMBLYSHEATHING PER STRUC.
\A1; PT 2x4 TREATED PLATE OVER SILL SEALER W/ ANCHOR BOLTS @ 6'-0" O.C. MAX. & 12" FROM CORNERREINFORCED CONCRETE SLABDRAINAGE PLANE BEHIND SIDINGSHEATHING PER STRUC.
1 LAYER OF 5/8" GYP BD., PER ASSEMBLY - CONTINUOUS TO THE UNDERSIDE OF THE ROOF SHEATHING ABOVE.
1 LAYER OF 5/8" GYP BD., PER ASSEMBLY - CONTINUOUS TO THE UNDERSIDE OF THE ROOF SHEATHING ABOVE.
FINISHED GRADE
1 LAYER OF 5/8" GYP. BD., PER ASSEMBLY
REF. FLOORFRAMING PLAN
SEAL ALL PERIMETER JOINTSW/ FIRE CAULK1 LAYER OF 5/8" GYP. BD., PER ASSEMBLY
\A1;
2x BLOCKING @ PLATES, TYP.
EXTERIOR TRIM TO BE APPLIED PER COMMUNITY SPECS.
EXTERIOR TRIM TO BE APPLIED PER COMMUNITY SPECS.
8
A
1/2" DRYWALL PER SPEC.2x FRAMING PER PLAN, REFER TO STRUC.
INSULATION PER ENERGY CALC'S.
1 HOUR RATED ASSEMBLY UL#U338
1 HOUR RATED ASSEMBLY \PUL#U305\PUL#U344\PUL#U3565/8" DRYWALL PER SPEC.1 LAYER OF 5/8" GYP. BD. CONTINUOUS TO THE UNDERSIDE OF THE FLOOR SHEATHING OR ROOF SHEATHING ABOVE. USE EXTERIOR RATED GP. BD. AT ALL CONCEALED SPACES (BEHIND FLOOR AND ATTIC SPACES).
2" X 6" BENT FLASHING/DRIP EDGE
2x FRAMING PER PLAN, REFER TO STRUC.
(2) 2x SILL PLATE (1 + 1 P.T.) OVER SILL SEALER @ 8'-0" BSMT.\P(1) 2x P.T. SILL PLATE OVER SILL SEALER @ 9'-0" BSMT. \PPROVIDE ANCHORAGE PER STRUC.
2x FRAMING PER PLAN, REFER TO STRUC.
\A1;CONCRETE SLAB OVER VAPOR BARRIER {\L\O\C7;(PER 2009, 2012, 2015, 2018 IRC R506.2.3)} OVER APPROVED BASE PER STRUC.FOUNDATION AND FOOTING WALL, REFER TO SHEED AD2.0
INSULATION PER ENERGY CALC'S.
1 LAYER OF 5/8" GYP. BD., PER ASSEMBLY
1 LAYER OF 5/8" GYP. BD. CONTINUOUS TO THE UNDERSIDE OF THE FLOOR SHEATHING OR ROOF SHEATHING ABOVE. USE EXTERIOR RATED GP. BD. AT ALL CONCEALED SPACES (BEHIND FLOOR AND ATTIC SPACES).
1 LAYER OF 5/8" GYP. BD. CONTINUOUS TO THE UNDERSIDE OF THE FLOOR SHEATHING OR ROOF SHEATHING ABOVE. USE EXTERIOR RATED GP. BD. AT ALL CONCEALED SPACES (BEHIND FLOOR AND ATTIC SPACES).
1 LAYER OF 5/8" GYP. BD., PER ASSEMBLYPROVIDE 2x BLOCKING @ PLATES, TYP.SEAL ALL PERIMETER JOINTS W/ FIRE CAULK
2x BLOCKING IN BETWEEN ROOF TRUSSES AS REQ'D.
\A1;T&G FLOOR SHEATHING, GLUE PER SPEC. & ATTACH PER STRUC.
\A1;T&G FLOOR SHEATHING, GLUE PER SPEC. & ATTACH PER STRUC.\A1;T&G FLOOR SHEATHING, GLUE PER SPEC. & ATTACH PER STRUC.SEAL ALL PERIMETER JOINTS W/ FIRE CAULK
FLOOR SYSTEM\PPER STRUCTURAL
FLOOR SYSTEM\PPER STRUCTURAL1 HOUR RATED ASSEMBLY \PUL#U305\PUL#U344\PUL#U356
1 HOUR RATED ASSEMBLY \PUL#U305\PUL#U344\PUL#U356
1 HOUR RATED ASSEMBLY \PUL#U305\PUL#U344\PUL#U356
SEAL ALL PERIMETER JOINTS W/ FIRE CAULK
{\LNOTE}:\PREFER TO AD2.0 SHEETS FOR AIR BARRIER SEALANT LOCATIONS
SEAL ALL PERIMETER JOINTS W/ FIRE CAULK
FOUNDATION WALL REF. TO SHEET AD2.0
DRAINAGE PLANE BEHIND SIDINGEXTERIOR TRIM TO BE APPLIED PER COMMUNITY SPECS.GABLE END TRUSS W/ VERTICALS @ 24" O.C.
2x4 BLOCKING
TYPICAL ROOF RETURN2" X 6" BENT FLASHING/DRIP EDGE\A1;
A
AA AA
SHEATHING PER STRUC.
1/2" DRYWALL PER SPEC.
INSULATION PER ENERGY CALC'S.
SEAL ALL PERIMETER JOINTS W/ FIRE CAULK
\A1;T&G FLOOR SHEATHING, GLUE PER SPEC. & ATTACH PER STRUC.
FLOOR SYSTEM\PPER STRUCTURAL
DRAFT STOP - BLK'G. W/ AIR BARRIER SEALANT AT EDGES
RIM BOARD PER STRUC.
SOFFIT PER SPEC.EXTEND J-MOULD/STARTER STRIP TO PROVIDE DRIP EDGE.
{\LNOTE}:\PREFER TO AD2.0 SHEETS FOR AIR BARRIER SEALANT LOCATIONS
(2) 2x SILL PLATE (1 + 1 P.T.) OVER SILL SEALER @ 8'-0" BSMT.\P(1) 2x P.T. SILL PLATE OVER SILL SEALER @ 9'-0" BSMT. \PPROVIDE ANCHORAGE PER STRUC.
PROVIDE 2x BLOCKING @ PLATES, TYP.SEAL ALL PERIMETER JOINTS W/ FIRE CAULK
{\LNOTE}:\PAT 2-HOUR FIRE SEPARATION EXTERIOR WALL OFFSET, EXTEND 5/8" TYPE 'X' GYP. BD. FULL LENGTH OF INTERIOR WALL UNTIL INTERSECTION OCCURS\POR\PPROVIDE DRYWALL SHIMS OR ADDITIONAL SKIM COAT COMPOUND TO FLUSH DRYWALL FINISHES
\A1;1" MIN.
STARTER STRIP
5/8" DRYWALL PER SPEC.ATTIC INSULATION PER ENERGY CALC'S., TYP.
ATTIC INSULATION PER ENERGY CALC'S., TYP.
PROVIDE 2x VERTICAL FURRING \PIN BETWEEN ROOF TRUSSES AS REQ'D
INGROUND CONDITION3{\H0.77778x;(PERPENDICULAR FRAMING)}
INGROUND CONDITION2{\H0.77778x;(PARALLEL FRAMING)}
1
INTERMEDIATE FLOORS4
CANTILEVERED FLOOR CONDITION5{\H0.77778x;(PARALLEL FRAMING)}
EAVE OVERHANG CONDITION6
GABLE END CONDITION7
PLAN NAME
SHEET
PRODUCTION MANAGERRELEASE DATE:DATE / DESCRIPTION
NPC PLAN NUMBERLAWSON PLAN IDLEGACY PLAN NUMBER / NAME
REV #
NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS
CURRENT 05/31/21JL
(c) Copyright Pulte Home Corporation - 2014
STD DETAILS150 Allen Rd, Suite 303Basking Ridge, New Jersey 07920Northeast Zone OfficePLOTTED: Aug. 24, 21 / Jeffrey Moskovciak / AD3.8 2015_2018 / C:\\USERS\\JMOSKOVCIAK\\ONEDRIVE - PULTEGROUP\\DESKTOP\\TEMP\\_PUBLISHING\\_TEMP SDP\\2021-05-31 (WIP DO NOT USE)\\NEZ STANDARD DETAIL SHEETS\\BASE FILES (DO NOT MODIFY)\\NEZ AD3.SERIES-FIRE RATED DETAILS.DWGFire Blocking Details at RoofCornice Returns and Building OffsetsAD3.81HR - FIRE RATED ASSEMBLY WALL SECTIONSSCALE :3/4" = 1'-0"A
NOT USED
NOT USED
NOT USED
10/10/22