HomeMy WebLinkAboutNEZ AD3.series-Fire Rated Details-AD3.8 2015_2018\A1;5/8" TYPE "X" DRYWALL PER SPEC. \A1;2x_ FIRE BLOCKING IN ROOF OVERHANG (CUT TO SEAL TIGHT), AS REQUIRED\A1;{\H1x;GABLE END OR EAVE OVERHANG CONDITION (SHOWN HATCHED) PER 1-HR RATED WALL SECTIONS (THIS SHEET)}\A1;LINE OF ROOF OVERHANG OR ROOF RETURN \A1;LINE OF ROOF OVERHANG OR GABLE EXTENSION FIRE BLOCKING AT ROOF TYP. OFFSET EXT. WALL - 1 HRSCALE 3/4" = 1'-0" \A1;{\L\C6;NOTE\l:}\P\pxsm0.85;{\A0;REFER TO OFFSET DETAILS ON SHEET AD3.0} 1 HOUR RATED ASSEMBLY\PUL#U305\PUL#U344\PUL#U356 \A1; 9 DRAINAGE PLANE BEHIND SIDINGDRAINAGE PLANE BEHIND SIDING RIM BOARD PER STRUC. SLAB ON GRADE / GARAGE FOUNDATION SHEATHING PER STRUC. FINISHED GRADE SHEATHING PER STRUC. DRAINAGE PLAINSIDING PER MANUFACTURERS\PSPECIFICATIONS SCALE: 2-1/2" = 1'-0"FLASHING DETAIL 1 LAYER OF 5/8" GYP. BD., PER ASSEMBLYSHEATHING PER STRUC. \A1; PT 2x4 TREATED PLATE OVER SILL SEALER W/ ANCHOR BOLTS @ 6'-0" O.C. MAX. & 12" FROM CORNERREINFORCED CONCRETE SLABDRAINAGE PLANE BEHIND SIDINGSHEATHING PER STRUC. 1 LAYER OF 5/8" GYP BD., PER ASSEMBLY - CONTINUOUS TO THE UNDERSIDE OF THE ROOF SHEATHING ABOVE. 1 LAYER OF 5/8" GYP BD., PER ASSEMBLY - CONTINUOUS TO THE UNDERSIDE OF THE ROOF SHEATHING ABOVE. FINISHED GRADE 1 LAYER OF 5/8" GYP. BD., PER ASSEMBLY REF. FLOORFRAMING PLAN SEAL ALL PERIMETER JOINTSW/ FIRE CAULK1 LAYER OF 5/8" GYP. BD., PER ASSEMBLY \A1; 2x BLOCKING @ PLATES, TYP. EXTERIOR TRIM TO BE APPLIED PER COMMUNITY SPECS. EXTERIOR TRIM TO BE APPLIED PER COMMUNITY SPECS. 8 A 1/2" DRYWALL PER SPEC.2x FRAMING PER PLAN, REFER TO STRUC. INSULATION PER ENERGY CALC'S. 1 HOUR RATED ASSEMBLY UL#U338 1 HOUR RATED ASSEMBLY \PUL#U305\PUL#U344\PUL#U3565/8" DRYWALL PER SPEC.1 LAYER OF 5/8" GYP. BD. CONTINUOUS TO THE UNDERSIDE OF THE FLOOR SHEATHING OR ROOF SHEATHING ABOVE. USE EXTERIOR RATED GP. BD. AT ALL CONCEALED SPACES (BEHIND FLOOR AND ATTIC SPACES). 2" X 6" BENT FLASHING/DRIP EDGE 2x FRAMING PER PLAN, REFER TO STRUC. (2) 2x SILL PLATE (1 + 1 P.T.) OVER SILL SEALER @ 8'-0" BSMT.\P(1) 2x P.T. SILL PLATE OVER SILL SEALER @ 9'-0" BSMT. \PPROVIDE ANCHORAGE PER STRUC. 2x FRAMING PER PLAN, REFER TO STRUC. \A1;CONCRETE SLAB OVER VAPOR BARRIER {\L\O\C7;(PER 2009, 2012, 2015, 2018 IRC R506.2.3)} OVER APPROVED BASE PER STRUC.FOUNDATION AND FOOTING WALL, REFER TO SHEED AD2.0 INSULATION PER ENERGY CALC'S. 1 LAYER OF 5/8" GYP. BD., PER ASSEMBLY 1 LAYER OF 5/8" GYP. BD. CONTINUOUS TO THE UNDERSIDE OF THE FLOOR SHEATHING OR ROOF SHEATHING ABOVE. USE EXTERIOR RATED GP. BD. AT ALL CONCEALED SPACES (BEHIND FLOOR AND ATTIC SPACES). 1 LAYER OF 5/8" GYP. BD. CONTINUOUS TO THE UNDERSIDE OF THE FLOOR SHEATHING OR ROOF SHEATHING ABOVE. USE EXTERIOR RATED GP. BD. AT ALL CONCEALED SPACES (BEHIND FLOOR AND ATTIC SPACES). 1 LAYER OF 5/8" GYP. BD., PER ASSEMBLYPROVIDE 2x BLOCKING @ PLATES, TYP.SEAL ALL PERIMETER JOINTS W/ FIRE CAULK 2x BLOCKING IN BETWEEN ROOF TRUSSES AS REQ'D. \A1;T&G FLOOR SHEATHING, GLUE PER SPEC. & ATTACH PER STRUC. \A1;T&G FLOOR SHEATHING, GLUE PER SPEC. & ATTACH PER STRUC.\A1;T&G FLOOR SHEATHING, GLUE PER SPEC. & ATTACH PER STRUC.SEAL ALL PERIMETER JOINTS W/ FIRE CAULK FLOOR SYSTEM\PPER STRUCTURAL FLOOR SYSTEM\PPER STRUCTURAL1 HOUR RATED ASSEMBLY \PUL#U305\PUL#U344\PUL#U356 1 HOUR RATED ASSEMBLY \PUL#U305\PUL#U344\PUL#U356 1 HOUR RATED ASSEMBLY \PUL#U305\PUL#U344\PUL#U356 SEAL ALL PERIMETER JOINTS W/ FIRE CAULK {\LNOTE}:\PREFER TO AD2.0 SHEETS FOR AIR BARRIER SEALANT LOCATIONS SEAL ALL PERIMETER JOINTS W/ FIRE CAULK FOUNDATION WALL REF. TO SHEET AD2.0 DRAINAGE PLANE BEHIND SIDINGEXTERIOR TRIM TO BE APPLIED PER COMMUNITY SPECS.GABLE END TRUSS W/ VERTICALS @ 24" O.C. 2x4 BLOCKING TYPICAL ROOF RETURN2" X 6" BENT FLASHING/DRIP EDGE\A1; A AA AA SHEATHING PER STRUC. 1/2" DRYWALL PER SPEC. INSULATION PER ENERGY CALC'S. SEAL ALL PERIMETER JOINTS W/ FIRE CAULK \A1;T&G FLOOR SHEATHING, GLUE PER SPEC. & ATTACH PER STRUC. FLOOR SYSTEM\PPER STRUCTURAL DRAFT STOP - BLK'G. W/ AIR BARRIER SEALANT AT EDGES RIM BOARD PER STRUC. SOFFIT PER SPEC.EXTEND J-MOULD/STARTER STRIP TO PROVIDE DRIP EDGE. {\LNOTE}:\PREFER TO AD2.0 SHEETS FOR AIR BARRIER SEALANT LOCATIONS (2) 2x SILL PLATE (1 + 1 P.T.) OVER SILL SEALER @ 8'-0" BSMT.\P(1) 2x P.T. SILL PLATE OVER SILL SEALER @ 9'-0" BSMT. \PPROVIDE ANCHORAGE PER STRUC. PROVIDE 2x BLOCKING @ PLATES, TYP.SEAL ALL PERIMETER JOINTS W/ FIRE CAULK {\LNOTE}:\PAT 2-HOUR FIRE SEPARATION EXTERIOR WALL OFFSET, EXTEND 5/8" TYPE 'X' GYP. BD. FULL LENGTH OF INTERIOR WALL UNTIL INTERSECTION OCCURS\POR\PPROVIDE DRYWALL SHIMS OR ADDITIONAL SKIM COAT COMPOUND TO FLUSH DRYWALL FINISHES \A1;1" MIN. STARTER STRIP 5/8" DRYWALL PER SPEC.ATTIC INSULATION PER ENERGY CALC'S., TYP. ATTIC INSULATION PER ENERGY CALC'S., TYP. PROVIDE 2x VERTICAL FURRING \PIN BETWEEN ROOF TRUSSES AS REQ'D INGROUND CONDITION3{\H0.77778x;(PERPENDICULAR FRAMING)} INGROUND CONDITION2{\H0.77778x;(PARALLEL FRAMING)} 1 INTERMEDIATE FLOORS4 CANTILEVERED FLOOR CONDITION5{\H0.77778x;(PARALLEL FRAMING)} EAVE OVERHANG CONDITION6 GABLE END CONDITION7 PLAN NAME SHEET PRODUCTION MANAGERRELEASE DATE:DATE / DESCRIPTION NPC PLAN NUMBERLAWSON PLAN IDLEGACY PLAN NUMBER / NAME REV # NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS CURRENT 05/31/21JL (c) Copyright Pulte Home Corporation - 2014 STD DETAILS150 Allen Rd, Suite 303Basking Ridge, New Jersey 07920Northeast Zone OfficePLOTTED: Aug. 24, 21 / Jeffrey Moskovciak / AD3.8 2015_2018 / C:\\USERS\\JMOSKOVCIAK\\ONEDRIVE - PULTEGROUP\\DESKTOP\\TEMP\\_PUBLISHING\\_TEMP SDP\\2021-05-31 (WIP DO NOT USE)\\NEZ STANDARD DETAIL SHEETS\\BASE FILES (DO NOT MODIFY)\\NEZ AD3.SERIES-FIRE RATED DETAILS.DWGFire Blocking Details at RoofCornice Returns and Building OffsetsAD3.81HR - FIRE RATED ASSEMBLY WALL SECTIONSSCALE :3/4" = 1'-0"A NOT USED NOT USED NOT USED 10/10/22