HomeMy WebLinkAboutIN Wall Sections Sheathing Overhang-AD 2.3Indiana Division11590 North Meridian Street, Suite 530Carmel, Indiana 46032...........................
PLAN NAME
SHEET
PRODUCTION MANAGER
DATE / DESCRIPTION
NPC PLAN NUMBERLAWSON PLAN ID
GARAGE HANDING
REV #
NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS
INITIAL RELEASE DATE:CURRENT RELEASE DATE:
(c) Copyright Pulte Home Corporation - 2021
Rick Starkey06/21/2019
----
--------------
--
--
06/21/2019
PLOTTED: September 21, 2021 / Michael Urban / IN WALL SECTIONS SHEATHING OVERHANG.DWG
AD
2.3Typical Wall Section2 Story w/ SlabIndianapolis Division\A1;1'-0"
\A1;4"
INSULATION BAFFLEPRE-ENGINEERED TRUSSES AT 24" O.C. - SPAN TO INSIDE OF SHEATHING SEE STRUCTURAL DWGS
DBL TOP PLATEWINDOW HEADER PER STRUCTURAL\A1;10{\H0.750000x;\S1#4;}"
12PER ELEV
TOP OF FASCIATOP OF\PPLATEVERIFY SHEATHING CONDITION WITH STRUCTURAL DWGS
\A1;2'-0" - ICE AND WATER SHIELD
DRYWALL PER SPEC
INSULATION R-38 BLOWN
STUDS PER SPECINSULATION R-15
DRYWALL PER SPEC\A1;8'-1{\H0.750000x;\S1#8;}"TOP OF 2ND FLR PLATEGUTTERS PER OPTION / ELEVATIONMETAL DRIP EDGE PER SPEC
1x3 ON 1x12 FRIEZE (RIPPED) W/ (2) 1x3 PACKOUT FOR SIDING
\A1;1x6 ENGINEERED TRIM FASCIA OVER 2x4 SUB-FASCIA PER SPEC
FULLY VENTED SOFFIT PER SPEC2x2 BLOCKING
ROOF SHINGLE PER SPEC OVER 15# FELT W/ ICE & WATER SHIELD TO 24" INSIDE OF WALL OVER EXTERIOR ROOF SHEATHING PER SPEC
FLOOR SYSTEM PER STRUCTURAL PLANS
\A1;9'-1{\H0.750000x;\S1#8;}"\A1;PER STRUCTURAL PLANS
\A1;8'-1{\H0.750000x;\S1#8;}"
TOP OF 1ST FLR PLATE
3/4" T&G SUBFLOOR OVER FLOOR JOIST., ATTACHMENT PER SPECCONT. CAULK BEADBASE TRIM PER SPEC.CONT. ADHESIVE BEAD
DRYWALL PER SPECDOUBLE TOP PLATE AT EXTERIOR WALLSDRYWALL PER SPEC
BUILDING WRAP OVER SHEATHING PER SPEC OVER 2X4 FRAMING
INSULATION R-15
RIM BOARD PER ENGINEERING
INSULATION R-19
\A1;9'-1{\H0.750000x;\S1#8;}"TOP OF SLAB\A1;2" x 5{\H0.7x;\S1/2;}" SLAB LEDGE
CONT. CAULK BEADBASE TRIM PER SPEC.CONT. ADHESIVE BEADBUILDING WRAP OVER SHEATHING PER SPEC OVER 2x4 FRAMING
INSULATION R-15
\A1;8" MIN.FINISHED GRADE
SIDING PER ELEVATION
\A1;1'-4"
\A1;2'-10" - OR TO MIN. FROST DEPTH\A1;1'-0"
\A1;TYP. CONC. SLAB PER DET. 1 - SD.04
\A1;2'-0" INSULATION\A1;RIGID INSULATION R-10\PHORIZONTAL OR VERTICAL AS REQ'D BY CODE
\A1;6"
\A1;TYP. TRENCHED FTG\PSEE DET. 1\PSHEET SD.04
\A1;5{\H0.750000x;\S1#2;}"
\A1;2"
\A1;3"\A1;3"
\A1;{\H0.7x;\S1/2;}" HIGH DENSITY RIGID\PINSULATION
\A1;9'-1{\H0.750000x;\S1#8;}"
CONT. CAULK BEADBASE TRIM PER SPEC.CONT. ADHESIVE BEADFELT PAPER OVER BUILDING WRAP OVER SHEATHING PER SPEC OVER 2X4 FRAMINGINSULATION R-15
FINISHED GRADE
\A1;QUEEN BRICK VENEER
\A1;RUBBERIZED THRU-WALL FLASHING - BLDG WRAP APPLIED ONT TOP OF FLASHING\A1;8" MIN.
\A1;BRICK LEDGE PER STRUCTURAL DETAIL
PROVIDE WEEP HOLES @ 24" O.C. WITH SOLID GROUT BEHIND FIRST 2 COURSES
\A1;7{\H0.750000x;\S1#2;}"
\A1;3{\H0.750000x;\S1#2;}"\A1;4"
\A1;1'-0"
\A1;1'-4"
\A1;2'-10" - OR TO MIN. FROST DEPTH
\A1;PER PLAN
\A1;2"\A1;2{\H0.750000x;\S1#2;}"
\A1;TYP. CONC. SLAB PER DET. 1 - SD.04
\A1;2'-0" INSULATION\A1;RIGID INSULATION R-10\PHORIZONTAL OR VERTICAL AS REQ'D BY CODE
\A1;{\H0.7x;\S1/2;}" HIGH DENSITY RIGID INSULATION
\A1;TYP. TRENCHED FTG\PSEE DET. 1\PSHEET SD.04
FLOOR SYSTEM PER STRUCTURAL PLANS
\A1;9'-1{\H0.750000x;\S1#8;}"\A1;PER STRUCTURAL PLANS
\A1;8'-1{\H0.750000x;\S1#8;}"
TOP OF 1ST FLR PLATE
3/4" T&G SUBFLOOR OVER FLOOR JOIST., ATTACHMENT PER SPECCONT. CAULK BEADBASE TRIM PER SPEC.CONT. ADHESIVE BEAD
DRYWALL PER SPECDOUBLE TOP PLATE AT EXTERIOR WALLSDRYWALL PER SPEC
FELT PAPER OVER BUILDING WRAP OVER SHEATHING PER SPEC OVER 2X4 FRAMING
INSULATION R-15
RIM BOARD PER ENGINEERINGTOP OF 2ND FLR
BRICK TIES AT 16" O.C. MAX. VERTICALLY\P32" O.C. MAX. HORIZ.
QUEEN SIZE BRICK VENEER1" AIR SPACE
INSULATION R-19
\A1;8'-1{\H0.750000x;\S1#8;}"
\A1;1'-0"
\A1;4"
INSULATION BAFFLEPRE-ENGINEERED TRUSSES AT 24" O.C. - SPAN TO INSIDE OF SHEATHING SEE STRUCTURAL DWGS
DBL TOP PLATEWINDOW HEADER PER STRUCTURAL\A1;10{\H0.750000x;\S1#4;}"
12PER ELEV
TOP OF FASCIATOP OF\PPLATEVERIFY SHEATHING CONDITION WITH STRUCTURAL DWGS
\A1;2'-0" - ICE AND WATER SHIELD
DRYWALL PER SPEC
INSULATION R-38 BLOWN
STUDS PER SPECINSULATION R-15
DRYWALL PER SPECTOP OF 2ND FLR PLATEGUTTERS PER OPTION / ELEVATIONMETAL DRIP EDGE PER SPEC
1x3 ON 1x12 FRIEZE (RIPPED) W/ PACKOUT FOR BRICK VENEERBRICK VENEER PER SPEC
\A1;1x6 ENGINEERED TRIM FASCIA OVER 2x4 SUB-FASCIA PER SPEC
FULLY VENTED SOFFIT PER SPEC2x2 BLOCKING
ROOF SHINGLE PER SPEC OVER 15# FELT W/ ICE & WATER SHIELD TO 24" INSIDE OF WALL OVER EXTERIOR ROOF SHEATHING PER SPEC
B SC. 1-1/2" = 1'-0"
SIDING AND TRIM PER ELEVATION
TYPICAL 1 STORY WALL SECTION w/ SLAB A SC. 1-1/2" = 1'-0"
BRICK VENEER AND TRIM PER ELEVATION
TYPICAL 1 STORY WALL SECTION w/ SLAB
10/10/22