0.20IN - AMBLESIDE CommunityGeneral Notes4-Unit Building GENERAL NOTES \A1;\pxsm1.5;{\fCentury Gothic|b0|i0|c0|p34;\H1.3333x;\W1;\LGENERAL REQUIREMENTS\P\pi-3,l3,s*,t3;\Fsimplex|c0;\H0.75x;\l1. WORK PERFORMED SHALL COMPLY WITH THE FOLLOWING:\P\pi-4,l7,tz;1.1. THESE GENERAL NOTES UNLESS OTHERWISE NOTED ON PLANS OR IN SPECIFICATIONS\P1.2. APPLICABLE NATIONAL CODES (IRC, NEC, IECC ETC.) LATEST ADOPTED EDITION WITH LOCAL AMMENDMENTS\P1.3. ALL APPLICABLE LOCAL AND STATE CODES, ORDINANCES AND REGULATIONS\P1.4. IN AREAS WHERE THE DRAWINGS SPECIFICATIONS OR SCOPES OF WORK DO NOT ADDRESS METHODOLOGY, THE CONTRACTOR SHALL BE BOUND TO PERFORM IN STRICT COMPLIANCE WIITH MANUFACTURER'S SPECIFICATIONS AND/OR RECOMMENDATIONS\P\pi-3,l3,t3;2. ON-SITE VERIFICATIONS OF ALL DIMENSIONS AND CONDITIONS SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR AND SUBCONTRACTORS. NOTED DIMENSIONS TAKE PRECEDENCE OVER SCALE.\P3. THE GENERAL NOTES AND TYPICAL DETAILS APPLY THROUGHOUT THE PROJECT UNLESS OTHERWISE NOTED OR SHOWN.\P4. DISCREPANCIES:\P\pi-4,l7,tz;4.1. THE CONTRACTOR SHALL COMPARE AND COORDINATE ALL DRAWINGS \P4.2. WHEN IN THE OPINION OF THE CONTRACTOR, A DISCREPANCY EXISTS, THE CONTRACTOR SHALL PROMPTLY REPORT IT FOR PROPER RESOLUTION BEFORE PROCEEDING WITH THE WORK.\P\pi-3,l3,t3;5. OMISSIONS:\P\pi-4,l7,tz;5.1. IN THE EVENT CERTAIN FEATURES OF THE CONSTRUCTION ARE NOT FULLY SHOWN ON THE DRAWINGS, THEIR CONSTRUCTION SHALL BE OF THE SAME CHARACTER AS FOR SIMILAR CONDITIONS THAT ARE SHOWN OR NOTED\P5.2. WHERE NO SIMILAR FEATURE OR CONDITION EXISTS THE CONTRACTOR SHALL PROMPTLY REPORT IT FOR PROPER RESOLUTION BEFORE PROCEEDING WITH THE WORK.\P\pi-3,l3,t3;6. ALL WORK IS TO BE PERFORMED IN A PROFESSIONAL MANNER AND IN ACCORDANCE WITH STANDARD PRACTICE AND CONSISTENT WITH MANUFACTURER'S AND SUPPLIER'S RECOMMENDED INSTALLATION PROCEEDURES.\P7. DIMENSIONING:\P\pi-4,l7,tz;7.1. ALL DIMENSIONS SHALL BE READ OR CALCULATED - NOT SCALED\P7.2. ALL DIMENSIONS ARE TO FACE OF STUD OR FACE OF SHEATHING UNLESS NOTED OTHERWISE\P7.3. ALL DRAWINGS PRINTED AT 1:1 ARE AT A SCALE OF \H0.7x;\S1#4;\H1.4286x;" = 1'-0" UNLESS NOTED OTHERWISE\P7.4. ALL DIMENSIONS FOR SINGLE WINDOWS OR WINDOW CONFIGURATIONS ARE TO THE CENTERLINE OF THE OPENING.\P\pi-3,l3,t3;8. BEFORE SUBMITTING PROPOSALS, BIDDERS SHALL CAREFULLY EXAMINE THE DRAWINGS, INSPECT THE SITE AND ACQUAINT THEMSELVES WITH ALL GOVERNING CODES, ORDINANCES, REGULATIONS, LAWS, ETC. AND OTHERWISE FAMILIARIZE THEMSELVES WITH ALL MATTERS WHICH MAY AFFECT PERFORMANCE AND COMPLETION OF THE WORK. THE ACT OF SUBMITTING A PROPOSAL SHALL BE TAKEN TO MEAN THAT THE BIDDER HAS COMPLIED WITH ALL REQUIREMENTS OF THESE GENERAL NOTES AND SPECIFICATIONS AND THEREFORE NO CONCESSION WILL BE GRANTED BECAUSE OF ANY CLAIM OF MISUNDERSTANDING OR LACK OF INFORMATION.\P\pi0,l0,tz;\L\P\psm1.5;\fCentury Gothic|b0|i0|c0|p34;\H1.3333x;BUILDING PLANNING\P\pi-3,l3,s*,t3;\Fsimplex|c0;\H0.75x;\l1. STAIRS AND GUARDRAILS\P\pi-4,l7,tz;1.1. TREADS SHALL BE A MINIMUM OF 10" WITH RISERS OF 7-\H0.7x;\S3#4;\H1.4286x;" MAXIMUM.\P1.2. STAIRS WITH SOLID RISERS REQUIRE A NOSING OF NO LESS THAN \H0.7x;\S3#4;\H1.4286x;" AND NO MORE THAN 1-\H0.7x;\S1#4;\H1.4286x;". A NOSING IS NOT REQUIRED WHEN THE TREAD DEPTH IS A MINIMUM OF 11".\P1.3. RISERS SHALL BE VERTICAL OR SLOPED FROM UNDER THE LEADING EDGE OF THE TREAD ABOVE AT AN ANGLE OF NO MORE THAN 30%%D FROM VERTICAL.\P1.4. HANDRAILS SHALL BE PROVIDED ON AT LEAST ONE SIDE OF EACH CONTINUOUS RUN OF TREADS OR FLIGHT WITH 4 OR MORE RISERS.\P1.5. HANDRAILS SHALL PROVIDE GRASPABILITY IN ACCORDANCE WITH THE CURRENTLY ADOPTED VERSION OF THE IRC.\P1.6. ALL REQUIRED HANDRAILS SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE CURRENTLY ADOPTED EDITION OF THE IRC OR APPLICABLE LOCAL CODES. HANDRAILS SHALL BE PROVIDED ON AT LEAST ONE SIDE OF EACH CONTINUOUS RUN OF TREADS OR FLIGHT WITH 4 OR MORE RISERS.\P1.7. HANDRAIL HEIGHT SHALL NOT BE LESS THAN 34" OR MORE THAN 38" AS MEASURED VERTICALLY FROM THE SLOPED PLANE THAT ADJOINS THE TREAD NOSINGS AND SHALL BE CONTINUOUS FOR THE FULL LENGTH OF THE FLIGHT. HANDRAILS ADJACENT TO A WALL SHALL HAVE A SPACE NOT LESS THAN 1-1/2" BETWEEN THE WALL AND THE HANDRAIL.\P1.8. ALL REQUIRED GUARDRAILS AND GUARD WALLS SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE CURRENTLY ADOPTED EDITION OF THE IRC OR APPLICABLE LOCAL CODES. GUARDS SHALL NOT BE LESS THAN 36" HIGH MEASURED VERTICALLY ABOVE THE ADJACENT WALKING SURFACE AND NOT LESS THAN 34" HIGH MEASURED VERTICALLY FROM THE SLOPED PLANE THAT ADJOINS THE TREAD NOSINGS.\P\pi-3,l3,t3;2. GLAZING\P\pi-4,l7,tz;2.1. ALL GLAZING INSTALLED IN HAZARDOUS LOCATIONS AS DEFINED BY THE CURRENTLY ADOPTED EDITION OF THE IRC OR APPLICABLE LOCAL CODE SHALL HAVE A PERMANENT DESIGNATION OR LABEL AFFIXED TO EACH PANE OF GLAZING BEARING THE MANUFACTURER'S LABEL SHOWING THE TYPE AND THICKNESS OF GLASS. \P2.2. FOR OTHER THAN TEMPERED GLASS, LABELS MAY BE OMITTED PROVIDED THE BUILDING OFFICIAL APPROVES THE USE OF A CERTIFICATE, AFFIDAVIT OR OTHER EVIDENCE CONFIRMING COMPLIANCE WITH THE CURRENTLY ADOPTED EDITION OF THE IRC OR APPLICABLE LOCAL CODE.\P\pi-3,l3,t3;3. ALL BATHTUB AND SHOWER FLOORS AND WALLS ABOVE BATHTUBS WITH INSTALLED SHOWER HEADS AND IN SHOWER COMPARTMENTS SHALL BE FINISHED WITH A NON-ABSORBENT SURFACE. SUCH WALL SURFACES SHALL EXTEND TO A HEIGHT NOT LESS THAN 72" ABOVE THE FLOOR PER THE CURRENTLY ADOPTED EDITION OF THE IRC OR APPLICABLE LOCAL CODE.\P4. PROVIDE THERMO-PLY SHEATHING AND BATT INSULATION FILLING ALL CAVITIES AT EXTERIOR WALLS SURROUNDING TUBS AND SHOWERS.\P5. EGRESS\P\pi-4,l7,tz;5.1. BASEMENTS, HABITABLE ATTICS AND EVERY SLEEPING ROOM MUST HAVE AT LEAST ONE EMERGENCY ESCAPE OR RESCUE OPENING IN ACCORDANCE WITH THE CURRENTLY ADOPTED EDITION OF THE IRC OR APPLICABLE LOCAL CODES.\P5.2. EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL BE OPERATIONAL FROM THE INSIDE WITHOUT THE USE OF KEYS OR REQUIRING SPECIAL KNOWLEDGE. \P5.3. WHERE THE BASEMENT CONTAINS 1 OR MORE SLEEPING ROOMS, EMERGENCY ESCAPE OR RESCUE OPENINGS SHALL BE REQUIRED IN EACH SLEEPING ROOM. \P5.4. THE EMERGENCY ESCAPE OR RESCUE OPENING SHALL HAVE A CLEAR OPENING OF 5.7 SQUARE FEET WITH A SILL HEIGHT OF NO MORE THAN 44" ABOVE THE FLOOR OR 5.0 SQUARE FEET FOR GRADE-FLOOR ESCAPE OR RESCUE WINDOWS. THE CLEAR }\A1;\pxl7;{\W1;OPENING SHALL BE A MINIMUM OF 24' IN HEIGHT AND 20" IN \H0.99997x;WIDTH. \P\pi-4;5.5. EMERGENCY ESCAPE AND RESCUE OPENINGS WITH A FINISHED SILL HEIGHT BELOW THE ADJACENT GROUND LEVEL ELEVATION SHALL BE PROVIDED WITH A WINDOW WELL AND LADDER IN ACCORDANCE WITH THE CURRENTLY ADOPTED EDITION OF THE IRC OR APPLICABLE LOCAL CODES.\P\pi0,l0;\H0.99997x;\L\P\psm1.5;\fCentury Gothic|b0|i0|c0|p34;\H1.3333x;FOUNDATIONS\P\pi-3,l3,s*,t3;\Fsimplex|c0;\H0.75004x;\l1. WHERE DISCREPANCIES BETWEEN SOILS REPORT AND STRUCTURAL DRAWINGS OCCUR, CONTACT THE STRUCTURAL ENGINEER.\P2. FINISH GRADE SHALL PROVIDE POSITIVE DRAINAGE AWAY FROM STRUCTURE.\P3. SURFACE WATER TO DRAIN AWAY FROM STRUCTURE. THE GRADE SHALL FALL A MINIMUM OF 6" WITHIN THE FIRST 10 FEET (2% FOR IMPERVIOUS SURFACES)IN ACCORDANCE WITH THE CURRENTLY ADOPTED EDITION OF THE IRC OR APPLICABLE LOCAL CODES.\P4. GARAGE SLAB SHALL SLOPE A MIN. OF 2" AWAY FROM STRUCTURE.\P5. CONCRETE STOOPS AND PORCH/PATIO SLABS SHALL SLOPE A MIN. OF 1/4" PER FOOT AWAY FROM STRUCTURE.\P6. PROVIDE LEDGE UNDER FULL SIZE MASONRY AS INDICATED BY STRUCTURAL DRAWING.\P7. FOR ADDITIONAL INFORMATION SEE STRUCTURAL DRAWINGS AND NOTES\P\pi0,l0,tz;\H0.99995x;\P\pi-2,l2,sm1.5,t2;\fCentury Gothic|b0|i0|c0|p34;\H1.3333x;\LCARPENTRY / FRAMING\P\pi-3,l3,s*,t3;\Fsimplex|c0;\H0.75x;\l1. ALL ANGLED WALLS (OTHER THAN THOSE AT 90%%D) SHALL BE CONSIDERED TO BE AT 45%%D UNLESS NOTED OTHERWISE\P2. ALL STUDS AT EXTERIOR AND INTERIOR WALLS SHALL BE 2x4 UNLESS OTHERWISE NOTED\P3. ALL STUDS AT EXTERIOR WALLS AND INTERIOR BEARING WALLS TO BE FRAMED AT 16" O.C. UNLESS NOTED OTHERWISE\P4. ALL NON-BEARING WALLS, OTHER THAN IN THE KITCHEN AND PLANNING CENTERS, TO BE 2x4 STUDS AT 24" O.C. UNLESS OTHERWISE NOTED OR RESTRICTED BY LOCAL CODES OR ORDINANCES. KITCHEN AND PLANNING CENTER WALLS WHERE WALL CABINETS ARE TO BE HUNG SHALL BE FRAMED AT 16" O.C.\P5. PROVIDE DOUBLE 2x TOP PLATES AT ALL LOAD BEARING WALLS.\P6. PROVIDE SINGLE TOP PLATE AT ALL INTERIOR NON-LOADING BEARING WALLS.\P\pi0,l0,tz;\H1.3333x;\P\psm1.5;\fCentury Gothic|b0|i0|c0|p34;\H0.99995x;\LFIREPLACES & CHIMNEYS\Fsimplex|c0;\P\pi-3,l3,s*,t3;\H0.75x;\l1. ALL FIREPLACES SHALL BE U.L. APPROVED\P2. PROVIDE AN APPROVED FIRE STOP AT CHIMNEY / VENT PENETRATION OF FLOORS, CEILINGS AND ROOFS.\P3. VENT-LESS PRE-FABRICATED FIREPLACES SHALL BE INSTALLED PER MANUFACTURERS INSTALLATION INSTRUCTIONS.\P4. DIRECT-VENT FIREPLACES SHALL BE VENTED PER MANUFACTURER'S INSTRUCTIONS. INSTALLER IS RESPONSIBLE FOR VERIFYING VENT CLEARANCES MEET THE CURRENTLY ADOPTED EDITIONS OF THE INTERNATIONAL RESIDENTIAL CODE (IRC), INTERNATIONAL FIRECODE AND LOCAL CODES.\P\pi0,l0,sm1.5,tz;\P\fCentury Gothic|b0|i0|c0|p34;\H1.3333x;\LELECTRICAL\l\P\pi-3,l3,s*,t3;\Fsimplex|c0;\H0.75017x;\T0.9;1. ALL ELECTRICAL INSTALLATION SHALL MEET THE REQUIREMENTS OF THE CURRENTLY ADOPTED EDITION OF THE NATIONAL ELECTRIC CODE (NEC). AND INTERNATIONAL RESIDENTIAL CODE (IRC). ALL MATERIAL AND EQUIPMENT SHALL BEAR THE LABEL OF APPROVAL OF THE UNDERWRITERS LABORATORIES, INC. AND MEET THE REQUIREMENTS OF THE CURRENTLY ADOPTED EDITION OF THE NEC.\P2. STAIRWAYS WITHIN DWELLING UNITS SHALL HAVE AN ILLUMINATION LEVEL ON THE TREAD RUNS OF NOT LESS THAN 1 FOOTCANDLE. PROVIDE LIGHTING CONTROL AT EACH LEVEL. EXTERIOR STAIRWAYS SERVING A DWELLING UNIT SHALL HAVE A LIGHT IN THE IMMEDIATE VICINITY OF THE STAIR LANDING CLOSEST TO THE DWELLING UNIT.\P3. GFCI PROTECTION SHALL BE PROVIDED FOR ALL 125 VOLT, SINGLE PHASE, 15 AND 20 AMPERE RECEPTACLES INSTALLED IN THE FOLLOWING LOCATIONS:\P\pi-4,l7,tz;3.1. BATHROOMS\P3.2. GARAGE\P3.3. OUTDOORS: BALCONIES, DECKS, AND PORCHES (INCLUDING INSIDE SCREENED ENCLOSURES)\P3.4. UNFINISHED BASEMENT AREAS AND CRAWL SPACES\P3.5. SINKS LOCATED IN AREAS OTHER THAN A KITCHEN WHERE RECEPTACLES ARE INSTALLED WITHIN 6 FEET OF THE OUTSIDE EDGE OF A SINK.\P3.6. RECEPTACLES INTENDED TO SERVE KITCHEN COUNTER TOP SURFACES\P3.7. WITHIN 25'-0" AND ON THE SAME LEVEL OF OUTDOOR HEATING, AIR CONDITIONING OR REFRIGERATION EQUIPMENT.\P\pi-3,l3,t3;4. PROVIDE A MINIMUM OF (2) 20 AMP SMALL APPLIANCE BRANCH CIRCUITS FOR KITCHEN, DINING AND PANTRY AREAS LIMITED TO ONLY THE REQUIRED WALL AND COUNTERTOP OUTLETS, AND THE REFRIGERATOR.\P5. REQUIRED LAUNDRY RECEPTACLES SHALL BE SUPPLIED BY A SEPARATE 20 AMP CIRCUIT AND SHALL NOT INCLUDE ANY OTHER LIGHTS, FANS, OR ANY OTHER RECEPTACLES.\P6. REQUIRED BATHROOM RECEPTACLES SHALL BE SUPPLIED BY A SEPARATE 20 AMP CIRCUIT AND SHALL NOT INCLUDE ANY OTHER LIGHTS, FANS, OR ANY OTHER RECEPTACLES.\P7. ARC-FAULT CIRCUIT INTERRUPTION PROTECTIONS SHALL BE PROVIDED FOR ALL CIRCUITS SUPPLYING POWER TO BEDROOMS.\P8. ALL ELECTRICAL OUTLETS SHALL BE PLACED AT 15" TO CENTER OF OUTLET ABOVE FINISHED FLOOR, UNLESS NOTED IN THE FOLLOWING NOTES OR ON PLANS.\P9. ALL ELECTRICAL OUTLETS AT KITCHEN COUNTERS SHALL BE PLACED AT 44" TO CENTER OF OUTLET ABOVE FINISHED FLOOR, UNLESS OTHERWISE NOTED ON PLANS.\P10. ALL ELECTRICAL OUTLETS AT BATHROOMS SHALL BE PLACED AT 44" TO CENTER OF OUTLET ABOVE FINISHED FLOOR AT 36" HIGH COUNTERS, AND 41" ABOVE FINISHED FLOOR AT 33" HIGH COUNTERS, UNLESS OTHERWISE NOTED ON PLANS.\P11. ALL SWITCHES SHALL BE PLACED AT 38" TO CENTER OF SWITCH ABOVE FINISHED FLOOR, UNLESS OTHERWISE NOTED ON PLANS.\P12. ALL WALL MOUNTED LIGHT FIXTURES SHALL BE SET AT A HEIGHT OF 66" ABOVE FINISHED FLOOR, UNLESS OTHERWISE NOTED ON PLANS.\P13. SMOKE DETECTORS:\P\pi-4,l7,tz;13.1. SMOKE DETECTORS TO BE SUPPLIED BY THE HOUSE WIRING SYSTEM, HAVE BATTERY BACKUP AND EMIT A SIGNAL WHEN BATTERIES ARE LOW PER APPLICABLE CODES. \P13.2. SMOKE ALARMS SHALL BE INTERCONNECTED IN SUCH A MANNER THAT THE ACTIVATION OF ONE ALARM WILL ACTIVATE ALL OF THE ALARMS PER APPLICABLE CODES.\P13.3. INSTALLATION SHALL MEET NFPA 72-70. \P13.4. SMOKE DETECTORS SHALL BE LOCATED ON EACH FLOOR LEVEL IN THE VICINITY OF ALL BEDROOM ENTRANCE DOORS AND WITHIN EACH BEDROOM.\P\pi-3,l3,t3;14. CARBON MONOXIDE DETECTORS:\P\pi-4,l7,tz;14.1. CARBON MONOXIDE DETECTORS TO BE SUPPLIED BY THE HOUSE WIRING SYSTEM, HAVE BATTERY BACKUP AND EMIT A SIGNAL WHEN BATTERIES ARE LOW PER APPLICABLE CODES.\P14.2. CARBON MONOXIDE ALARMS SHALL BE INTERCONNECTED IN SUCH A }\A1;\pxl7;{\W1;\T0.9;MANNER THAT THE ACTIVATION OF ONE ALARM WILL ACTIVATE ALL OF THE ALARMS PER APPLICABLE CODES.\P\pi-4;\H1.0001x;14.3. A CARBON MONOXIDE ALARM IS REQUIRED OUTSIDE EACH SLEEPING AREA AND/OR IN THE IMMEDIATE VICINITY OF SLEEPING AREAS AS REQUIRED BY APPLICABLE CODES.\P14.4. ALL DETECTORS SHALL COMPLY WITH UL2034-2008.\P\pi-3,l3,t3;15. LIGHTING IN CLOTHES CLOSETS SHALL BE:\P\pi-4,l7,tz;15.1. SURFACE MOUNTED OR RECESSED INCANDESCENT OR LED LUMINAIRES WITH COMPLETELY ENCLOSED LIGHT SOURCES\P\H0.99999x;15.2. SURFACE MOUNTED OR RECESSED FLUORESCENT LUMINAIRES\P15.3. SURFACE MOUNTED FLUORESCENT OR LED LUMINAIRES IDENTIFIED AS SUITABLE FOR INSTALLATION WITHIN THE CLOSET STORAGE SPACE\P15.4. INSTALLED PER APPLICABLE CODES. \P15.5. FIXTURES MAY BE LOCATED ONLY WHERE THERE ARE THE FOLLOWING MINIMUM CLEARANCES TO THE NEAREST POINT OF STORAGE SPACE:\P\pi-5,l12,t8;15.5.1. SURFACE MOUNTED INCANDESCENT OR LED FIXTURES: 12" MINIMUM ON WALL ABOVE DOOR OR CEILING\P15.1.2. SURFACE MOUNTED FLUORESCENT FIXTURES: 6" MINIMUM ON WALL ABOVE DOOR OR CEILING\P15.1.3. RECESSED INCANDESCENT OR LED LUMINAIRES WITH COMPLETELY ENCLOSED LIGHT SOURCE INSTALLED IN WALL OR CEILING\P15.1.4. RECESSED FLUORESCENT LUMINAIRES INSTALLED IN WALL OR CEILING\P15.1.5. SURFACE MOUNTED FLUORESCENT OR LED LUMINAIRES SHALL BE PERMITTED TO BE INSTALLED WITHIN THE CLOSET STORAGE SPACE WHERE IDENTIFIED FOR THIS USE.\P\pi-3,l3,t3;16. NO PARTS OF HANGING FIXTURES, TRACK LIGHTING, AND CEILING PADDLE \H0.99999x;FANS SHALL BE INSTALLED WITHIN 3'-0" HORIZONTALLY OF A BATHTUB, MEASURED FROM THE OUTSIDE EDGE OF THE TUB AND 8'-0" VERTICALLY FROM THE TOP OF THE TUB RIM.\P17. RECEPTACLES SHALL NOT BE INSTALLED WITHIN A TUB OR A SHOWER ENCLOSURE.\P18. GROUNDING: RECEPTACLE OUTLETS FOR RANGES AND CLOTHES DRYER MUST BE A 3-POLE WITH GROUND TYPE.\P19. AN INTERSYSTEM BONDING TERMINAL SHALL BE PROVIDED FOR GROUNDING COMMUNICATION SYSTEMS (CABLE TV & SATELLITE DISHES).\P20. GROUNDING AND BONDING OF METAL PIPING SYSTEMS SHALL BE PER CODE.\P21. MECHANICAL, ELECTRICAL, AND PLUMBING SYSTEMS ARE SHOWN FOR INTENT ONLY. THESE SYSTEMS SHALL BE ENGINEERED BY OTHERS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROPER INSTALLATION AND PLACEMENT.\P22. VERIFY LOCATION OF ALL RECEPTACLES FOR APPLIANCES WITH MANUFACTURER SPECIFICATIONS.\P23. ALL RECEPTACLES CONTROLLED BY A SWITCH SHALL SPLIT-WIRED TO CONTROL ONLY THE TOP OUTLET\P\H0.99997x;24. ELECTRICAL CONTRACTOR SHALL VERIFY SPACE REQUIRED FOR METER INSTALLATION BEFORE CONSTRUCTION AND SHALL NOTIFY GENERAL CONTRACTOR OF ANY DISCREPANCIES.\P25. ALL 15 AND 20 AMP RECEPTACLE OUTLETS SHALL BE TAMPER RESISTANT.\P\pi0,l0,tz;\H1.333x;\T1;\P\psm1.5;\fCentury Gothic|b0|i0|c0|p34;\LPLUMBING\P\pi-3,l3,s*,t3;\Fsimplex|c0;\H0.75021x;\l1. PLUMBING DRAWINGS, DESIGNS AND SPECIFICATIONS, WHEN REQUIRED, SHALL TAKE PRECEDENCE OVER THESE NOTES IF AND WHEN CONFLICTS OCCUR.\H0.99972x;\P\pi0,l0,sm1.5,tz;\P\fCentury Gothic|b0|i0|c0|p34;\H1.3333x;\LHVAC\P\pi-3,l3,s*,t3;\Fsimplex|c0;\H0.75025x;\l1. MECHANICAL DRAWINGS, DESIGNS AND SPECIFICATIONS, WHEN REQUIRED, SHALL TAKE PRECEDENCE OVER THESE NOTES IF AND WHEN CONFLICTS OCCUR.\H0.99967x;\P\pi0,l0,tz;\P\pi-2,l2,t2;\fCentury Gothic|b0|i0|c0|p34;\H1.3333x;\LFIRE PROTECTION\Fsimplex|c0;\H0.75x;\P\P\pi-3,l3,t3;\l1. PROVIDE A 1-3/8" OR LARGER SOLID CORE WOOD DOOR, SOLID CORE STEEL DOOR OR HONEYCOMB CORE STEEL DOOR, OR 20 MINUTE FIRE-RATED DOOR EQUIPPED WITH A SELF-CLOSING DEVICE BETWEEN GARAGE AND LIVING SPACE IN ACCORDANCE WITH THE CURRENTLY ADOPTED EDITION OF THE IRC OR APPLICABLE LOCAL CODE. \P2. PROVIDE FIRE SEPARATION BETWEEN DWELLING AND GARAGE IN ACCORDANCE WITH THE CURRENTLY ADOPTED EDITION OF THE IRC OR APPLICABLE LOCAL CODE.\P3. PROVIDE \H0.7x;\S1#2;\H1.4286x;" DRYWALL AT WALLS, CEILING AND UNDERSIDE OR STAIR ASSEMBLY ACCESSIBLE SPACE UNDER STAIRS IN ACCORDANCE WITH THE CURRENTLY ADOPTED EDITION OF THE IRC OR APPLICABLE LOCAL CODE.\P4. FIRE BLOCKING SHALL BE PROVIDED TO CUT-OFF ALL VERTICAL AND HORIZONTAL CONCEALED OPENINGS AN TO FORM AN EFFECTIVE FIRE BARRIER BETWEEN STORIES AND BETWEEN EACH STORY AND ITS ASSOCIATED ROOF / ATTIC SPACE. FIRE BLOCKING SHALL BE PROVIDED IN THE FOLLOWING AREA:\P\pi-4,l7,tz;4.1. CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING FURRED SPACES AT CEILING AND FLOOR LEVELS.\P4.2. AT ALL INTERSECTIONS BETWEEN CONCEALED VERTICAL AND HORIZONTAL SPACES SUCH AS OCCUR AT SOFFITS, DROPPED CEILINGS, ETC.\P4.3. IN CONCEALED SPACES BETWEEN STAIR STRINGERS AT THE TOP AND BOTTOM OF RUN.\P4.4. AT OPENINGS AROUND VENTS, PIPES, DUCTS, CHIMNEYS AND FIREPLACES AS THEY PASS THROUGH CEILING AND FLORR LEVELS.\P\pi0,l0;\P\psm1.5;\fCentury Gothic|b0|i0|c0|p34;\H1.3333x;\LWALL BRACING\P\pi-3,l3,s*,t3;\Fsimplex|c0;\H0.75x;\l1. SEE ENGINEERING DESIGN, DRAWINGS AND SPECIFICATIONS.\P\pi0,l0,tz;\P\psm1.5;\fCentury Gothic|b0|i0|c0|p34;\H1.3333x;\LENERGY CODE COMPLIANCE\H0.75x;\P\pi-3,l3,s*,t3;\Fsimplex|c0;\l1. COMPLIANCE SHALL BE DEMONSTRATED BY:\P\pi-4,l7,tz;1.1. COMPLIANCE CERTIFICATES GENERATED BY AN APPROVED ENERGY CODE COMPLIANCE TOOL\P1.2. OTHER COMPARABLE COMPLIANCE MATERIALS THAT MEET OR EXCEED THE APPROVED COMPLIANCE TOOL\P\pi-3,l3,t3;2. A PERMANENT CERTIFICATE PREPARED BY BUILDER OR REGISTERED DESIGN PROFESSIONAL, MUST BE POSTED ON, IN OR NEAR THE ELECTRICAL DISTRIBUTION PANEL WHICH PROVIDES THE R-VALUES OF THE INSULATION INSTALLED, THE U-FACTORS, AND THE TYPES AND EFFICIENCIES OF HEATING, COOLING AND SERVICE WATER HEATING EQUIPMENT.\P3. THE BUILDING THERMAL ENVELOPE SHALL MEET THE REQUIREMENTS OF THE CURRENTLY ADOPTED VERSION OF THE IECC AND ANY LOCAL AMENDMENTS.\P4. ONE PROGRAMMABLE THERMOSTAT MUST BE PROVIDED FOR EACH SEPARATE HEATING AND COOLING SYSTEM.\P5. ALL DUCTS, AIR HANDLERS AND FILTER BOXES MUST BE SEALED. IF ANY SUPPLY OR RETURN DUCTING IS LOCATED OUTSIDE THE THERMAL ENVELOPE A DUCT TIGHTNESS TEST MUST BE PERFORMED.\P6. BUILDING FRAMING CAVITIES MUST NOT BE USED AS DUCTS OR PLENUMS.\P7. OUTDOOR INTAKES AND EXHAUSTS SHALL HAVE AUTOMATIC OR GRAVITY DAMPERS.\P8. A MINIMUM OF 75% OF THE LAMPS IN PERMANENTLY INSTALLED FIXTURES SHALL HAVE HIGH-EFFICACY LAMPS.}GENERAL REQUIREMENTS
BUILDING PLANNING
FOUNDATIONS
CARPENTRY / FRAMING
FIREPLACES & CHIMNEYS
ELECTRICAL
PLUMBING
HVAC
FIRE PROTECTION
WALL BRACING
ENERGY CODE COMPLIANCE
not applicable in Indiana