Loading...
HomeMy WebLinkAboutIN-Ambleside-4-Unit Bldg-Slab-CP 2.0PLOTTED: September 1, 2022 / Jeffrey Moskovciak / IN-AMBLESIDE-4-UNIT BLDG-SLAB.DWG CP 2.0IN - AMBLESIDE CommunityROOF PLAN4-Unit BuildingPRODUCTION MANAGER DATE / DESCRIPTIONREV # NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS INITIAL RELEASE DATE:CURRENT RELEASE DATE: PLAN NAME SHEETNPC PLAN NUMBER STAMP (c) Copyright Pulte Home Corporation - 2022 JL09-02-202209-02-2022 20' Unit 2463 Indiana Division11590 North Meridian Street, Suite 530Carmel, Indiana 46032ROOF PLAN - 4-UNIT BUILDING 1/8"=1'-0" LPLP\A1;79'-8" OVERALL FDN TO FDN\A1;19'-10" FRM TO PL\A1;20'-0" PL TO PL\A1;19'-10" PL TO FRM LPLP \A1;20'-0" PL TO PL\A1;19'-10" FRM TO PL\A1;19'-10" PL TO FRM \A1;40'-0" \A1;42'-0" OVERALL FRM TO FRM\A1;40'-0" LP \A1;20'-0" PL TO PL LP \A1;20'-0" PL TO PL {\C6;NOTE:} \P{\C4;REFERENCE CIVIL PLANS & LATEST PLOT PLAN FOR EACH UNIT PLAN \PFINISH ELEVATIONS ALONG WITH VERTICAL & HORIZONTAL OFFSETS.\P\PREFERENCE INDIVIDUAL UNIT ARCHITECTURAL PLANS FOR MORE INFORMATION.\P\PREFERENCE UNIT STRUCTURAL PLANS FOR ADDITIONAL INFORMATION INCLUDING FOOTING SIZES, CONCRETE REINFORCEMENT, DETAILS & NOTES.} \A1;{\L\C6;NOTE\l:}\P{\A0;PROVIDE 1-HR. RATED CONSTRUCTION AT EXTERIOR WALLS WITHIN 5 FT. OF PROPERTY LINE, REFER TO DETAIL } \A1;{\L\C6;NOTE\l:}\PPROVIDE NON-COMBUSTIBLE PLYWOOD SHEATHING MINIMUM 4 FT. FROM EACH SIDE OF PROPERTY LINE (SHOWN HATCHED), TYPICAL \P\pxsm0.85;{\A0;\PNO PENETRATIONS WITHIN 4 FT. OF PROPERTY LINE (EACH SIDE) \PIN NON-COMBUSTIBLE SHEATHING, TYPICAL \P(NOT REQUIRED @ END UNIT CONDITION)} REFERENCE UNIT PLANS FOR MORE INFORMATION EXACT UNIT PLAN & OPTION SELECTIONS TO BE DETERMINED REFERENCE UNIT PLANS FOR MORE INFORMATION EXACT UNIT PLAN & OPTION SELECTIONS TO BE DETERMINED REFERENCE UNIT PLANS FOR MORE INFORMATION EXACT UNIT PLAN & OPTION SELECTIONS TO BE DETERMINED B AD2.3 B AD2.3 B AD2.3 B AD2.3 B AD2.3 B AD2.3 B AD2.3 A6 AD3.0-1 A6 AD3.0-1 REFERENCE UNIT PLANS FOR MORE INFORMATION EXACT UNIT PLAN & OPTION SELECTIONS TO BE DETERMINEDA6 AD3.0-1 A6 AD3.0-1 \A1;EXTERIOR RATED WALL AT ROOF OFFSET, TYP. (SHOWN HATCHED) \A1;19'-8" FRM TO FRM\A1;19'-8" FRM TO FRM\A1;2"\A1;2"\A1;2"\A1;19'-8" FRM TO FRM\A1;2"\A1;2"\A1;19'-8" FRM TO FRM\A1;2" A6 AD3.0-1 A6 AD3.0-1 \A1;2'-0" Unit #2104 - FRANKTON End Unit - Front Door Right Elevation 5 \A1;{\W1;End Unit - Front Door Right\PElevation 5}}Unit #2103 - FRANKTON Interior Unit - Front Door Left Elevation 3 \A1;{\W1;Interior Unit - Front Door Left\PElevation 3}}Unit #2102 - FAIRWOOD Interior Unit - Front Door Left Elevation 5 \A1;{\W1;Interior Unit - Front Door Left\PElevation 5}}Unit #2101 - FRANKTON End Unit - Front Door Left Elevation 4 10/10/22