HomeMy WebLinkAboutMZ-NEZ Architectural Details-AD 1.2_PLOTTED: May 17, 2016 / W Mike Harkins / MZ-NEZ ARCHITECTURAL DETAILS.DWG
AD
1.2_Architectural DetailsTypical Material Transition DetailsEngineered Trim with Brick, Stone and LP SidingPLAN NAME
SHEET
PRODUCTION MANAGER
DATE / DESCRIPTION
NPC PLAN NUMBERLAWSON PLAN ID
GARAGE HANDING
REV #
NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS
INITIAL RELEASE DATE:CURRENT RELEASE DATE:
(c) Copyright Pulte Home Corporation - 2016
--
--
--
----
10UPDATE COL LOC06/25/201511UPDATE MISC11/24/201512SHOWER WINDOW04/14/201613NEZ ALIGNMENT04/15/201614UPDATE DETAILS05/17/2016............
PLAN NAME
SHEET
PRODUCTION MANAGER
DATE / DESCRIPTION
NPC PLAN NUMBERLAWSON PLAN ID
GARAGE HANDING
REV #
NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS
INITIAL RELEASE DATE:CURRENT RELEASE DATE:
7
RICK STARKEY4/8/3013
----
--
--
--1900 E. Golf Road - Suite 300Schaumburg, Illinois 60173Pulte Midwest ZoneET-16 SC. 1-1/2" = 1'-0" SIDING TO BRICK TRANSITION - ENGINEERED TRIM
MATERIAL TRANSITION DETAILS AT VARIED HEIGHTS SUCH AS WAINSCOTS ARE SIMILAR
MATERIAL TRANSITION DETAIL
BOTTOM OF ROWLOCK ALIGNS WITH BOTTOM OF SOFFIT AT EAVE
BRICK ROWLOCK W/ FLASHING\PEXTEND FLASHING 8" MIN BEHIND SIDING
SIDING PER ELEVATION
PROVIDE THRU-WALL FLASHING AND WEEP HOLES ABOVE OPENINGS
BOTTOM OF PRECAST CONC. SILL ALIGNS WITH BOTTOM OF SOFFIT AT EAVE
PRECAST CONC. SILL W/ FLASHING\PEXTEND FLASHING 8" MIN BEHIND SIDING
SIDING PER ELEVATION
ET-17 SC. 1-1/2" = 1'-0" SIDING TO STONE TRANSITION - ENGINEERED TRIM
MATERIAL TRANSITION DETAILS AT VARIED HEIGHTS SUCH AS WAINSCOTS ARE SIMILAR
MATERIAL TRANSITION DETAIL
TRIM PER ELEVATION
TRIM PER ELEVATION
ET-18 SC. 1-1/2" = 1'-0" AT CANTILEVER - ENGINEERED TRIM
MATERIAL TRANSITION DETAIL
\A1;VARIESBRACKET PER ELEV. - PER SPEC\A1;{\H0.7x;\S1#2;}" SOFFIT PER SPEC
ENGINEERED TRIM PER ELEV. PER SPEC
FLASHING UP 8" BEHIND SIDING
SIDING PER ELEV.
ENGINEERED TRIM PER ELEV. PER SPECMASONRY PER SPEC
ENGINEERED TRIM PER ELEV. PER SPEC
FLASHING UP 8" BEHIND SIDING
SIDING PER ELEV.
ET-19 SC. 1-1/2" = 1'-0" SIDING TO SIDING - ENGINEERED TRIM
MATERIAL TRANSITION DETAIL
SIDING PER ELEV.
FLASHING UP 8" BEHIND SIDING
\A1;5/4 x 6 ENGINEERED TRIM CLOSURE PER SPEC\POVERLAP VENEER 1"\PSEAL TO VENEER W/ SILICON CAULK
\A1;5/4 x 4 ENGINEERED TRIM CLOSURE PER SPEC\PBUTT TO VENEER SEAL W/ SILICON CAULK\A1;RUN VENEER TO {\H0.7x;\S1#2;}" MAX. FROM SHEATHING
ET-20 SC. 1-1/2" = 1'-0" SIDING TO BRICK VENEER - ENGINEERED TRIM
MATERIAL TRANSITION DETAIL - PLAN VIEW
\A1;5/4 x 4 AND 5/4 x 6 ENGINEERED TRIM CAULKED TO SIDING
\A1;{\H1x;5/4} x {\H1x;5/4} INTERIOR CORNER - CAULKED TO SIDING
\A1;5/4 x 6 ENGINEERED TRIM \POVERLAP VENEER 1"\PSEAL TO VENEER W/ SILICON CAULK
\A1;5/4 x 4 ENGINEERED TRIM CLOSURE PER SPEC\PBUTT TO VENEER SEAL W/ SILICON CAULK\A1;RUN VENEER TO {\H0.7x;\S1#2;}" MAX. FROM SHEATHING
ET-21 SC. 1-1/2" = 1'-0" SIDING TO STONE VENEER - ENGINEERED TRIM
MATERIAL TRANSITION DETAIL - PLAN VIEW
ET-22 SC. 1-1/2" = 1'-0" SIDING TO SIDING VENEER - ALUM. WRAPPED TRIM
MATERIAL TRANSITION DETAIL - PLAN VIEW
ET-23 SC. 1-1/2" = 1'-0" SIDING TO CONCRETE AT WALKOUT CONDITIONS - ENGINEERED TRIM
MATERIAL TRANSITION DETAIL - PLAN VIEW
FOUNDATION WITH NO RETURN SHOWN DASHED
\A1;{\H1x;5/4}"x6" TRIM
FOUNDATION RETURN PER PLAN
\A1;SIDING PER SPEC
\A1;BENT ALUM. FLASHING UNDER DRAINAGE PLANE
10/10/22