Loading...
HomeMy WebLinkAboutMZ-NEZ Architectural Details-AD 1.2_PLOTTED: May 17, 2016 / W Mike Harkins / MZ-NEZ ARCHITECTURAL DETAILS.DWG AD 1.2_Architectural DetailsTypical Material Transition DetailsEngineered Trim with Brick, Stone and LP SidingPLAN NAME SHEET PRODUCTION MANAGER DATE / DESCRIPTION NPC PLAN NUMBERLAWSON PLAN ID GARAGE HANDING REV # NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS INITIAL RELEASE DATE:CURRENT RELEASE DATE: (c) Copyright Pulte Home Corporation - 2016 -- -- -- ---- 10UPDATE COL LOC06/25/201511UPDATE MISC11/24/201512SHOWER WINDOW04/14/201613NEZ ALIGNMENT04/15/201614UPDATE DETAILS05/17/2016............ PLAN NAME SHEET PRODUCTION MANAGER DATE / DESCRIPTION NPC PLAN NUMBERLAWSON PLAN ID GARAGE HANDING REV # NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS INITIAL RELEASE DATE:CURRENT RELEASE DATE: 7 RICK STARKEY4/8/3013 ---- -- -- --1900 E. Golf Road - Suite 300Schaumburg, Illinois 60173Pulte Midwest ZoneET-16 SC. 1-1/2" = 1'-0" SIDING TO BRICK TRANSITION - ENGINEERED TRIM MATERIAL TRANSITION DETAILS AT VARIED HEIGHTS SUCH AS WAINSCOTS ARE SIMILAR MATERIAL TRANSITION DETAIL BOTTOM OF ROWLOCK ALIGNS WITH BOTTOM OF SOFFIT AT EAVE BRICK ROWLOCK W/ FLASHING\PEXTEND FLASHING 8" MIN BEHIND SIDING SIDING PER ELEVATION PROVIDE THRU-WALL FLASHING AND WEEP HOLES ABOVE OPENINGS BOTTOM OF PRECAST CONC. SILL ALIGNS WITH BOTTOM OF SOFFIT AT EAVE PRECAST CONC. SILL W/ FLASHING\PEXTEND FLASHING 8" MIN BEHIND SIDING SIDING PER ELEVATION ET-17 SC. 1-1/2" = 1'-0" SIDING TO STONE TRANSITION - ENGINEERED TRIM MATERIAL TRANSITION DETAILS AT VARIED HEIGHTS SUCH AS WAINSCOTS ARE SIMILAR MATERIAL TRANSITION DETAIL TRIM PER ELEVATION TRIM PER ELEVATION ET-18 SC. 1-1/2" = 1'-0" AT CANTILEVER - ENGINEERED TRIM MATERIAL TRANSITION DETAIL \A1;VARIESBRACKET PER ELEV. - PER SPEC\A1;{\H0.7x;\S1#2;}" SOFFIT PER SPEC ENGINEERED TRIM PER ELEV. PER SPEC FLASHING UP 8" BEHIND SIDING SIDING PER ELEV. ENGINEERED TRIM PER ELEV. PER SPECMASONRY PER SPEC ENGINEERED TRIM PER ELEV. PER SPEC FLASHING UP 8" BEHIND SIDING SIDING PER ELEV. ET-19 SC. 1-1/2" = 1'-0" SIDING TO SIDING - ENGINEERED TRIM MATERIAL TRANSITION DETAIL SIDING PER ELEV. FLASHING UP 8" BEHIND SIDING \A1;5/4 x 6 ENGINEERED TRIM CLOSURE PER SPEC\POVERLAP VENEER 1"\PSEAL TO VENEER W/ SILICON CAULK \A1;5/4 x 4 ENGINEERED TRIM CLOSURE PER SPEC\PBUTT TO VENEER SEAL W/ SILICON CAULK\A1;RUN VENEER TO {\H0.7x;\S1#2;}" MAX. FROM SHEATHING ET-20 SC. 1-1/2" = 1'-0" SIDING TO BRICK VENEER - ENGINEERED TRIM MATERIAL TRANSITION DETAIL - PLAN VIEW \A1;5/4 x 4 AND 5/4 x 6 ENGINEERED TRIM CAULKED TO SIDING \A1;{\H1x;5/4} x {\H1x;5/4} INTERIOR CORNER - CAULKED TO SIDING \A1;5/4 x 6 ENGINEERED TRIM \POVERLAP VENEER 1"\PSEAL TO VENEER W/ SILICON CAULK \A1;5/4 x 4 ENGINEERED TRIM CLOSURE PER SPEC\PBUTT TO VENEER SEAL W/ SILICON CAULK\A1;RUN VENEER TO {\H0.7x;\S1#2;}" MAX. FROM SHEATHING ET-21 SC. 1-1/2" = 1'-0" SIDING TO STONE VENEER - ENGINEERED TRIM MATERIAL TRANSITION DETAIL - PLAN VIEW ET-22 SC. 1-1/2" = 1'-0" SIDING TO SIDING VENEER - ALUM. WRAPPED TRIM MATERIAL TRANSITION DETAIL - PLAN VIEW ET-23 SC. 1-1/2" = 1'-0" SIDING TO CONCRETE AT WALKOUT CONDITIONS - ENGINEERED TRIM MATERIAL TRANSITION DETAIL - PLAN VIEW FOUNDATION WITH NO RETURN SHOWN DASHED \A1;{\H1x;5/4}"x6" TRIM FOUNDATION RETURN PER PLAN \A1;SIDING PER SPEC \A1;BENT ALUM. FLASHING UNDER DRAINAGE PLANE 10/10/22