Loading...
HomeMy WebLinkAbout2463-NZ-Base-UTIL-FL2-U1 4-2.10-KCPLOTTED: April 1, 2020 / Jeffrey Moskovciak / 2463-NZ-BASE-UTIL-FL2.DWG U1 4-2.10-KCSecond Floor Utility Plan.2x4 Exterior WallsPRODUCTION MANAGER DATE / DESCRIPTIONREV # NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS INITIAL RELEASE DATE:CURRENT RELEASE DATE: PLAN NAME SHEETNPC PLAN NUMBER STAMP (c) Copyright Pulte Home Corporation - 2019 JL04/30/1703/31/20 20' Unit 2463 150 Allen Rd, Suite 303Basking Ridge, New Jersey 07920Northeast Zone OfficeSECOND FLOOR PLAN - KITCHEN CENTER - 2x4 WALLS TO LIGHT BELOW TO LIGHT ABOVE S3 PR GFISS GATHERING ROOM OPT. WATER LINE GFI+44" GFI+44" DW S3S KITCHENSDISP220VOPT. GAS VALVE+68" FOR HOODw/ ELEC.110V GFI w/ OPT. GAS \A1;3'-0" \pxql;OPT. LIGHT/FAN\PBRACE AND PRE-WIRE \A1;9'-6"\A1;4'-9" \A1;6'-10" \A1;4'-0"\A1;3'-5{\H0.75x;\S1#2;}" \A1;6'-6" \A1;5'-4{\H0.75x;\S1#2;}" \A1;7'-2"GFI GFI CAFE \A1;5'-3"\A1;4'-9"\A1;4'-0" SSSS3S3S WAP GFIGFI MOUNT NO MORE THAN 12" BELOW COUNTERTOP @ BOTH ENDS +44" LIGHT FAN S/C UTILITY LEGEND SYMBOL SYMBOL TYPE ADDITIONAL NOITES ADDRESS SIGNADDRESS SIGN - VISIBLE FROM STREET. LETTERS OR NUMBERS FOR THE ADDRESS SHALL BE 4" MIN. IN HEIGHT AND 0.5" MIN. IN STROKE OF A CONTRASTING COLOR TO THE BACKGROUND ITSELF CHIMES - DOORBELLDETECTOR - HEATCEILING MOUNTED HEAT DETECTOR TO BE HARD WIRED TO FIRE ALARM SYSTEM (INSTALL PER CODE) DETECTOR - SMOKE/CARBON MONOXIDE COMBINATIONUL APPROVED CEILING MOUNTED SMOKE /CO DETECTOR TO BE HARD WIRED WITH BATTERY BACK-UP (INSTALL PER CODE) DETECTOR - CARBON MONOXIDEUL APPROVED CEILING MOUNTED CO DETECTOR TO BE HARD WIRED WITH BATTERY BACK-UP (INSTALL PER CODE) DETECTOR - SMOKEUL APPROVED CEILING MOUNTED SMOKE DETECTOR TO BE HARD WIRED WITH BATTERY BACK-UP (INSTALL PER CODE) DISCONNECT - SWITCHEDFAN - CEILING W/ LIGHTFAN BOX PER CODE. PROVIDE 4-WIRE CABLE FROM SWITCH(ES) (CLG FAN OPTIONAL) FAN - EXHAUSTEXHAUST TO EXTERIORFAN - EXHAUST W/ LIGHTEXHAUST TO EXTERIORLIGHT - CEILINGLIGHT - CEILING-PULL CHAINLIGHT - FLUORESCENT-48X9LIGHT - FLUORESCENT-UNDER CAB-14 LIGHT - RECESSEDLIGHT - RECESSED-VAPOR PROOFLIGHT - WALLLIGHT - WALL-PULL CHAINMETER - ELECTRICVERIFY LOCATION IN FIELDOUTLET - 220VOUTLET - DISHWASHEROUTLET - DUPLEXOUTLET - DUPLEX-SPLIT WIREDOUTLET - FLOOROUTLET - GFIOUTLET - GARAGE DOOROUTLET - PHONECAT 5EOUTLET - TVRG-6OUTLET - WATERPROOF-GFIPANEL - ELECTRICVERIFY LOCATION IN FIELDSWITCH - DISPOSALSWITCH - LIGHTSWITCH - THREE WAYSWITCH - FOUR WAYSWITCH - PUSH BUTTONTHERMOSTATTHERMOSTAT SHALL BE PROGRAMMABLEHOSE BIBBWATER SERVICEGAS VALVEGAS METERRETURN AIR GRILLEWATER METERWIRELESS ACCESS POINTSTRUCTURED WIRING PANEL HS/C C S PC 14RV PCE220VDW GFIGFI PHTVWP/GFI SDISPS3SS4 THBOPT.\PWATER LINE GAS VALVEGR.A.G.W MEDIA/SWPWAP GOURMET KITCHEN OPTION OPT. WATER LINE GFI+44" DWKITCHENSDISP220VOPT. GAS VALVE+68" FOR HOODw/ ELEC.110V GFI w/ OPT. GAS GFI+44" 220VFOR MICRO.GFI GFI GFIGFI MOUNT NO MORE THAN 12" BELOW COUNTERTOP @ BOTH ENDS BEVERAGE CENTER 1 OPTION BEVERAGE CENTER +44"GFIS CAFE CABINETS OPTION CAFE GFI+44" GFI GFI +44" +44" CHEF'S KITCHEN OPTION OPT. WATER LINE GFI+44" DWKITCHENSDISP220VOPT. GAS VALVE+68" FOR HOODw/ ELEC.110V GFI w/ OPT. GAS GFI+44" 220VFOR MICRO.GFI GFI GFIGFI MOUNT NO MORE THAN 12" BELOW COUNTERTOP @ BOTH ENDS DECK 5 OPTIONDECK 6 OPTION GATHERING ROOM DECK 5 SWP/GFI+68" A.F.F. GATHERING ROOM DECK 6 SWP/GFI+68" A.F.F. DECK 2 OPTION GATHERING ROOM DECK 2 SWP/GFI+68" A.F.F. DECK 1 OPTION DECK 1 SWP/GFI PPC OPTION PPC+38" SBELOW+38" 10/10/22