HomeMy WebLinkAboutAmbleside - IN - Master Structural - Foundation-S-1.0METAL HANGER BEARING WALL ABOVE (B.W.A.) AREA OF FLOOR SYSTEM DESIGNED FOR TILE BEAM / HEADER INTERIOR BEARING WALL INTERIOR BRACED WALL PANEL INDICATES POST ABOVE. PROVIDE SOLID\PBLOCKING UNDER POST OR JAMB ABOVE.*INDICATES HOLDOWN BELOW. LEGEND OR OSB SHEATHING \A1;4'-0"REFER TO S-0 FOR TYPICAL STRUCTURAL NOTES & SCHEDULES \A1;{\Farchquik|c0;\H0.7x;\S1#2;\H1.429x;" DIA. TITEN HD ANCHOR W/ MIN. 10" EMBED (OR PRE-APPROVED EQUAL) INTO CONCRETE OR 3,000 PSI GROUTED CMU CELLS.} \A1;HTT TENSION TIE HOLD-DOWN\P(SEE PLANS)PROVIDE (2) STUDS (MIN.) @ HOLD-DOWN LOCATION ATYPICAL HOLD-DOWN INSTALLATION{\Farchtitl.shx;NOT TO SCALE} \A1;4'-0" DRAWN BY: AMK CHECKED BY: JGF DATE:10/22/21 M&K JOB #: 160-15003 REVISION # & DATE DESCRIPTION HOLDOWN SCHEDULE SYMBOLSPECIFICATION \A1;* ANCHOR HOLDOWN UTILIZING {\H0.7x;\S5#8;}" DIA. THREADED ROD EPOXY SET INTO CONCRETE FOUNDATION w/ SIMPSON "SET" EPOXY SYSTEM PER MANUF. RECOMMENDATIONS. PROVIDE 10" MIN. EMBEDMENT INTO CONCRETE. DO NOT LOCATE EPOXY SET ANCHORS WITHIN 1 {\H0.7x;\S3#4;}" OF FACE ON CONCRETE FOUNDATION WALL. \P(OR - PROVIDE 12" MIN. EMBEDMENT INTO SOLID GROUT. DO NOT LOCATE EPOXY SET ANCHORS WITHIN 3" OF FACE ON CMU FOUNDATION WALL){\LALTERNATIVE TO SSTB24 ANCHOR BOLT SPECIFICATION:} \pxt26;SIMPSON STHD14RJ HOLDOWN (WET-SET ANCHOR)HD-1SIMPSON HTT4 HOLDOWN *- OR - HD-2SIMPSON MSTC40 STRAP TIE (12" END LENGTH) \A1;4'-0" \A1;20'-0" PL TO PL \A1;20'-0" PL TO PL \A1;20'-3{\H0.75x;\S1#2;}" \A1;40'-7" \A1;20'-3{\H0.75x;\S1#2;}" \A1;40'-7" \A1;1'-10{\H0.75x;\S1#2;}"\A1;16'-3"\A1;1'-10{\H0.75x;\S1#2;}" \A1;20'-3{\H0.75x;\S1#2;}" \A1;20'-3{\H0.75x;\S1#2;}" \A1;20'-3{\H0.75x;\S1#2;}" \A1;4'-0{\H0.75x;\S1#2;}" SLAB FOUNDATION PLANSCALE: 1/4"=1'-0" SD.04A SD.04A18 SD.04A18 SD.045 SD.04SD.0410 SD.04A SD.04 SD.0410 PA*PA* \A1;\pxql;24"x24"x12" PLAIN CONC. FTG. \A1;\pxqc;{\LGARAGE SLAB \P}-SEE NOTES ON S-0 \A1;\pxqc;{\LSLAB ON GRADE\P}-SEE NOTES ON S-0 \A1;HD-1\A1;HD-1PA*PA*PA* PA*PA*\A1;8'-9" \A1;11'-6{\H0.75x;\S1#2;}" \A1;7'-10{\H0.750000x;\S3#4;}"\A1;12'-1{\H0.750000x;\S1#4;}" TYP. @ HDS-1.0A KITCHEN REAR3 \A1;16'-3" \A1;40'-7" \A1;2'-0" \A1;20'-3{\H0.75x;\S1#2;}" \A1;20'-3{\H0.75x;\S1#2;}" \A1;20'-1{\H0.7x;\S1#2;}" FDN TO PL\A1;16'-3" \A1;9{\H0.75x;\S1#2;}" \A1;12'-0" \A1;7'-6"\A1;4'-0{\H0.75x;\S1#2;}" PARTIAL SLAB FOUNDATION PLANSCALE: 1/4"=1'-0"KITCHEN REAR1 SD.049 SD.04 SD.0410 PA* PA*PA* PA*\A1;8'-9" \A1;11'-6{\H0.75x;\S1#2;}" \A1;8'-0{\H0.75x;\S1#4;}" PA* \A1;40'-7" \A1;2'-0" \A1;20'-3{\H0.75x;\S1#2;}" \A1;20'-3{\H0.75x;\S1#2;}" \A1;20'-1{\H0.7x;\S1#2;}" FDN TO PL\A1;16'-3" \A1;4'-0{\H0.75x;\S1#2;}" PARTIAL SLAB FOUNDATION PLANSCALE: 1/4"=1'-0"KITCHEN REAR2 SD.049 SD.04 SD.0410 PA* PA*PA* PA* \A1;8'-0{\H0.75x;\S1#4;}" \A1;8'-9" \A1;11'-6{\H0.75x;\S1#2;}" PA* PLOTTED: October 27, 2021 / Karl G. Kattermann / AMBLESIDE - IN - MASTER STRUCTURAL - FOUNDATION.DWGFOUNDATION PLANS-1.0 PRODUCTION MANAGER DATE / DESCRIPTIONREV # NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS INITIAL RELEASE DATE:CURRENT RELEASE DATE: PLAN NAME SHEETNPC PLAN NUMBER STAMP (c) Copyright Pulte Home Corporation - 2021 JL04/30/1709/24/21 20' Unit 2463 Indiana Division11590 North Meridian Street, Suite 530Carmel, Indiana 4603210/10/22