HomeMy WebLinkAboutAmbleside - IN - Master Structural - Foundation-S-6.0METAL HANGER
BEARING WALL ABOVE (B.W.A.)
AREA OF FLOOR SYSTEM DESIGNED FOR TILE
BEAM / HEADER
INTERIOR BEARING WALL
INTERIOR BRACED WALL PANEL
INDICATES POST ABOVE. PROVIDE SOLID\PBLOCKING UNDER POST OR JAMB ABOVE.*INDICATES HOLDOWN BELOW.
LEGEND
OR OSB SHEATHING
\A1;4'-0"REFER TO S-0 FOR TYPICAL STRUCTURAL NOTES & SCHEDULES
\A1;{\Farchquik|c0;\H0.7x;\S1#2;\H1.429x;" DIA. TITEN HD ANCHOR W/ MIN. 10" EMBED (OR PRE-APPROVED EQUAL) INTO CONCRETE OR 3,000 PSI GROUTED CMU CELLS.}
\A1;HTT TENSION TIE HOLD-DOWN\P(SEE PLANS)PROVIDE (2) STUDS (MIN.) @ HOLD-DOWN LOCATION
ATYPICAL HOLD-DOWN INSTALLATION{\Farchtitl.shx;NOT TO SCALE}
DRAWN BY: AMK
CHECKED BY: JGF
DATE:10/22/21
M&K JOB #: 160-15003
REVISION # & DATE DESCRIPTION
HOLDOWN SCHEDULE
SYMBOLSPECIFICATION
\A1;* ANCHOR HOLDOWN UTILIZING {\H0.7x;\S5#8;}" DIA. THREADED ROD EPOXY SET INTO CONCRETE FOUNDATION w/ SIMPSON "SET" EPOXY SYSTEM PER MANUF. RECOMMENDATIONS. PROVIDE 10" MIN. EMBEDMENT INTO CONCRETE. DO NOT LOCATE EPOXY SET ANCHORS WITHIN 1 {\H0.7x;\S3#4;}" OF FACE ON CONCRETE FOUNDATION WALL. \P(OR - PROVIDE 12" MIN. EMBEDMENT INTO SOLID GROUT. DO NOT LOCATE EPOXY SET ANCHORS WITHIN 3" OF FACE ON CMU FOUNDATION WALL){\LALTERNATIVE TO SSTB24 ANCHOR BOLT SPECIFICATION:}
\pxt26;SIMPSON STHD14RJ HOLDOWN (WET-SET ANCHOR)HD-1SIMPSON HTT4 HOLDOWN *- OR -
HD-2SIMPSON MSTC40 STRAP TIE (12" END LENGTH)
PARTIAL 2ND FLOOR FRAMING PLANSCALE: 1/4"=1'-0"OPT. BEDROOM 6 w/ BATH 6 OPT.1
\A1;{\H0.83333x;3" O.C. EDGE NAILING\A1;{\H0.83333x;(SEE NOTES)}}
\A1;16" F.T. U.N.O.\P(@ 19.2" O.C. MAX SPACING)\A1;GIRDER DRAG TRUSS (350 PLF)
\A1;HD-1 \PBELOW
(2)2x4
\A1;HD-1 \PBELOW
(2)2x4
\A1;FLOOR GIRDER TRUSS
\A1;16" F.T. U.N.O.\P(@ 19.2" O.C. MAX SPACING)(2)2x4
\A1;FLOOR GIRDER TRUSS OR (2)1{\H0.7x;\S3#4;}"x16" LVL FLUSH
PA*S-2.0B
\A1;LADDER TRUSS
(2)2x4*(2)2x4
PARTIAL SLAB FOUNDATION PLANSCALE: 1/4"=1'-0"OPT. BEDROOM 6 w/ BATH 6 OPT.2
\A1;20'-3{\H0.75x;\S1#2;}"\A1;20'-0" P/L TO P/L\A1;20'-3{\H0.75x;\S1#2;}"
\A1;4'-0{\H0.75x;\S1#2;}"SD.045
\A1;HD-1\A1;HD-1PA*PA*PA*TYP. @ HDS-6.0A
\A1;20'-0" PL TO PL
\A1;1'-10{\H0.75x;\S1#2;}"
PLOTTED: October 27, 2021 / Karl G. Kattermann / AMBLESIDE - IN - MASTER STRUCTURAL - FOUNDATION.DWGFOUNDATION PLANS-6.0
PRODUCTION MANAGER
DATE / DESCRIPTIONREV #
NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS
INITIAL RELEASE DATE:CURRENT RELEASE DATE:
PLAN NAME
SHEETNPC PLAN NUMBER
STAMP
(c) Copyright Pulte Home Corporation - 2021
JL04/30/1709/24/21
20' Unit
2463 Indiana Division11590 North Meridian Street, Suite 530Carmel, Indiana 4603210/10/22