Loading...
HomeMy WebLinkAboutAmbleside - IN - Master Structural - Foundation-S-6.0METAL HANGER BEARING WALL ABOVE (B.W.A.) AREA OF FLOOR SYSTEM DESIGNED FOR TILE BEAM / HEADER INTERIOR BEARING WALL INTERIOR BRACED WALL PANEL INDICATES POST ABOVE. PROVIDE SOLID\PBLOCKING UNDER POST OR JAMB ABOVE.*INDICATES HOLDOWN BELOW. LEGEND OR OSB SHEATHING \A1;4'-0"REFER TO S-0 FOR TYPICAL STRUCTURAL NOTES & SCHEDULES \A1;{\Farchquik|c0;\H0.7x;\S1#2;\H1.429x;" DIA. TITEN HD ANCHOR W/ MIN. 10" EMBED (OR PRE-APPROVED EQUAL) INTO CONCRETE OR 3,000 PSI GROUTED CMU CELLS.} \A1;HTT TENSION TIE HOLD-DOWN\P(SEE PLANS)PROVIDE (2) STUDS (MIN.) @ HOLD-DOWN LOCATION ATYPICAL HOLD-DOWN INSTALLATION{\Farchtitl.shx;NOT TO SCALE} DRAWN BY: AMK CHECKED BY: JGF DATE:10/22/21 M&K JOB #: 160-15003 REVISION # & DATE DESCRIPTION HOLDOWN SCHEDULE SYMBOLSPECIFICATION \A1;* ANCHOR HOLDOWN UTILIZING {\H0.7x;\S5#8;}" DIA. THREADED ROD EPOXY SET INTO CONCRETE FOUNDATION w/ SIMPSON "SET" EPOXY SYSTEM PER MANUF. RECOMMENDATIONS. PROVIDE 10" MIN. EMBEDMENT INTO CONCRETE. DO NOT LOCATE EPOXY SET ANCHORS WITHIN 1 {\H0.7x;\S3#4;}" OF FACE ON CONCRETE FOUNDATION WALL. \P(OR - PROVIDE 12" MIN. EMBEDMENT INTO SOLID GROUT. DO NOT LOCATE EPOXY SET ANCHORS WITHIN 3" OF FACE ON CMU FOUNDATION WALL){\LALTERNATIVE TO SSTB24 ANCHOR BOLT SPECIFICATION:} \pxt26;SIMPSON STHD14RJ HOLDOWN (WET-SET ANCHOR)HD-1SIMPSON HTT4 HOLDOWN *- OR - HD-2SIMPSON MSTC40 STRAP TIE (12" END LENGTH) PARTIAL 2ND FLOOR FRAMING PLANSCALE: 1/4"=1'-0"OPT. BEDROOM 6 w/ BATH 6 OPT.1 \A1;{\H0.83333x;3" O.C. EDGE NAILING\A1;{\H0.83333x;(SEE NOTES)}} \A1;16" F.T. U.N.O.\P(@ 19.2" O.C. MAX SPACING)\A1;GIRDER DRAG TRUSS (350 PLF) \A1;HD-1 \PBELOW (2)2x4 \A1;HD-1 \PBELOW (2)2x4 \A1;FLOOR GIRDER TRUSS \A1;16" F.T. U.N.O.\P(@ 19.2" O.C. MAX SPACING)(2)2x4 \A1;FLOOR GIRDER TRUSS OR (2)1{\H0.7x;\S3#4;}"x16" LVL FLUSH PA*S-2.0B \A1;LADDER TRUSS (2)2x4*(2)2x4 PARTIAL SLAB FOUNDATION PLANSCALE: 1/4"=1'-0"OPT. BEDROOM 6 w/ BATH 6 OPT.2 \A1;20'-3{\H0.75x;\S1#2;}"\A1;20'-0" P/L TO P/L\A1;20'-3{\H0.75x;\S1#2;}" \A1;4'-0{\H0.75x;\S1#2;}"SD.045 \A1;HD-1\A1;HD-1PA*PA*PA*TYP. @ HDS-6.0A \A1;20'-0" PL TO PL \A1;1'-10{\H0.75x;\S1#2;}" PLOTTED: October 27, 2021 / Karl G. Kattermann / AMBLESIDE - IN - MASTER STRUCTURAL - FOUNDATION.DWGFOUNDATION PLANS-6.0 PRODUCTION MANAGER DATE / DESCRIPTIONREV # NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS INITIAL RELEASE DATE:CURRENT RELEASE DATE: PLAN NAME SHEETNPC PLAN NUMBER STAMP (c) Copyright Pulte Home Corporation - 2021 JL04/30/1709/24/21 20' Unit 2463 Indiana Division11590 North Meridian Street, Suite 530Carmel, Indiana 4603210/10/22