Loading...
HomeMy WebLinkAboutIN Wall Sections Sheathing Overhang-AD 2.2Indiana Division11590 North Meridian Street, Suite 530Carmel, Indiana 46032........................... PLAN NAME SHEET PRODUCTION MANAGER DATE / DESCRIPTION NPC PLAN NUMBERLAWSON PLAN ID GARAGE HANDING REV # NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS INITIAL RELEASE DATE:CURRENT RELEASE DATE: (c) Copyright Pulte Home Corporation - 2021 Rick Starkey06/21/2019 ---- -------------- -- -- 06/21/2019 PLOTTED: September 21, 2021 / Michael Urban / IN WALL SECTIONS SHEATHING OVERHANG.DWG AD 2.2Typical Wall Sections1 Story w/ SlabIndianapolis Division\A1;1'-0" \A1;4" INSULATION BAFFLEPRE-ENGINEERED TRUSSES AT 24" O.C. - SPAN TO INSIDE OF SHEATHING SEE STRUCTURAL DWGS DBL TOP PLATEWINDOW HEADER PER STRUCTURAL\A1;10{\H0.750000x;\S1#4;}" 12PER ELEV TOP OF FASCIATOP OF\PPLATEVERIFY SHEATHING CONDITION WITH STRUCTURAL DWGS \A1;2'-0" - ICE AND WATER SHIELD DRYWALL PER SPEC INSULATION R-38 BLOWN STUDS PER SPECINSULATION R-15 DRYWALL PER SPEC\A1;8'-1{\H0.750000x;\S1#8;}"TOP OF 2ND FLR PLATEGUTTERS PER OPTION / ELEVATIONMETAL DRIP EDGE PER SPEC 1x3 ON 1x12 FRIEZE (RIPPED) W/ (2) 1x3 PACKOUT FOR SIDING \A1;1x6 ENGINEERED TRIM FASCIA OVER 2x4 SUB-FASCIA PER SPEC FULLY VENTED SOFFIT PER SPEC2x2 BLOCKING ROOF SHINGLE PER SPEC OVER 15# FELT W/ ICE & WATER SHIELD TO 24" INSIDE OF WALL OVER EXTERIOR ROOF SHEATHING PER SPEC \A1;9'-1{\H0.750000x;\S1#8;}"TOP OF SLAB\A1;2" x 5{\H0.7x;\S1/2;}" SLAB LEDGE CONT. CAULK BEADBASE TRIM PER SPEC.CONT. ADHESIVE BEADBUILDING WRAP OVER SHEATHING PER SPEC OVER 2x4 FRAMING INSULATION R-15 \A1;8" MIN.FINISHED GRADE SIDING PER ELEVATION \A1;1'-4" \A1;2'-10" - OR TO MIN. FROST DEPTH\A1;1'-0" \A1;TYP. CONC. SLAB PER DET. 1 - SD.04 \A1;2'-0" INSULATION\A1;RIGID INSULATION R-10\PHORIZONTAL OR VERTICAL AS REQ'D BY CODE \A1;6" \A1;TYP. TRENCHED FTG\PSEE DET. 1\PSHEET SD.04 \A1;5{\H0.750000x;\S1#2;}" \A1;2" \A1;3"\A1;3" \A1;{\H0.7x;\S1/2;}" HIGH DENSITY RIGID\PINSULATION \A1;9'-1{\H0.750000x;\S1#8;}" CONT. CAULK BEADBASE TRIM PER SPEC.CONT. ADHESIVE BEADFELT PAPER OVER BUILDING WRAP OVER SHEATHING PER SPEC OVER 2X4 FRAMINGINSULATION R-15 FINISHED GRADE \A1;QUEEN BRICK VENEER \A1;RUBBERIZED THRU-WALL FLASHING - BLDG WRAP APPLIED ONT TOP OF FLASHING\A1;8" MIN. \A1;BRICK LEDGE PER STRUCTURAL DETAIL PROVIDE WEEP HOLES @ 24" O.C. WITH SOLID GROUT BEHIND FIRST 2 COURSES \A1;7{\H0.750000x;\S1#2;}" \A1;3{\H0.750000x;\S1#2;}"\A1;4" \A1;1'-0" \A1;1'-4" \A1;2'-10" - OR TO MIN. FROST DEPTH \A1;PER PLAN \A1;2"\A1;2{\H0.750000x;\S1#2;}" \A1;TYP. CONC. SLAB PER DET. 1 - SD.04 \A1;2'-0" INSULATION\A1;RIGID INSULATION R-10\PHORIZONTAL OR VERTICAL AS REQ'D BY CODE \A1;{\H0.7x;\S1/2;}" HIGH DENSITY RIGID INSULATION \A1;TYP. TRENCHED FTG\PSEE DET. 1\PSHEET SD.04 \A1;8'-1{\H0.750000x;\S1#8;}" \A1;1'-0" \A1;4" INSULATION BAFFLEPRE-ENGINEERED TRUSSES AT 24" O.C. - SPAN TO INSIDE OF SHEATHING SEE STRUCTURAL DWGS DBL TOP PLATEWINDOW HEADER PER STRUCTURAL\A1;10{\H0.750000x;\S1#4;}" 12PER ELEV TOP OF FASCIATOP OF\PPLATEVERIFY SHEATHING CONDITION WITH STRUCTURAL DWGS \A1;2'-0" - ICE AND WATER SHIELD DRYWALL PER SPEC INSULATION R-38 BLOWN STUDS PER SPECINSULATION R-15 DRYWALL PER SPECTOP OF 2ND FLR PLATE BRICK TIES AT 16" O.C. MAX. VERTICALLY\P32" O.C. MAX. HORIZ. GUTTERS PER OPTION / ELEVATIONMETAL DRIP EDGE PER SPEC 1x3 ON 1x12 FRIEZE (RIPPED) W/ PACKOUT FOR BRICK VENEERBRICK VENEER PER SPEC \A1;1x6 ENGINEERED TRIM FASCIA OVER 2x4 SUB-FASCIA PER SPEC FULLY VENTED SOFFIT PER SPEC2x2 BLOCKING ROOF SHINGLE PER SPEC OVER 15# FELT W/ ICE & WATER SHIELD TO 24" INSIDE OF WALL OVER EXTERIOR ROOF SHEATHING PER SPEC B SC. 1-1/2" = 1'-0" SIDING AND TRIM PER ELEVATION TYPICAL 2 STORY WALL SECTION w/ SLAB A SC. 1-1/2" = 1'-0" BRICK VENEER AND TRIM PER ELEVATION TYPICAL 2 STORY WALL SECTION w/ SLAB 10/10/22