HomeMy WebLinkAboutMZ-NEZ Architectural Details-AD 3.2_PLOTTED: May 17, 2016 / W Mike Harkins / MZ-NEZ ARCHITECTURAL DETAILS.DWG
AD
3.2_Architectural DetailsInterior Details - Modern Trim PackageColumn, Stair and Counter Top DetailsPLAN NAME
SHEET
PRODUCTION MANAGER
DATE / DESCRIPTION
NPC PLAN NUMBERLAWSON PLAN ID
GARAGE HANDING
REV #
NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS
INITIAL RELEASE DATE:CURRENT RELEASE DATE:
(c) Copyright Pulte Home Corporation - 2016
--
--
--
----
10UPDATE COL LOC06/25/201511UPDATE MISC11/24/201512SHOWER WINDOW04/14/201613NEZ ALIGNMENT04/15/201614UPDATE DETAILS05/17/2016............
PLAN NAME
SHEET
PRODUCTION MANAGER
DATE / DESCRIPTION
NPC PLAN NUMBERLAWSON PLAN ID
GARAGE HANDING
REV #
NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS
INITIAL RELEASE DATE:CURRENT RELEASE DATE:
7
RICK STARKEY4/8/3013
----
--
--
--1900 E. Golf Road - Suite 300Schaumburg, Illinois 60173Pulte Midwest Zone1/2" GYP. BD
\A1;1"\A1;8"SURFACE PER SPEC
CASINGSURFACE PER SPEC
OUTLET BOX PLACED HORIZ. - HOLD TIGHT TO TOP PLATE
IT-15 SC. 1-1/2" = 1'-0" AT KITCHEN
MODERN TRIM PACKAGE
CAPPED KNEEWALL
AAD 3.2
BAD 3.2
\A1;4{\H0.750000x;\S3#4;}"
\A1;EDGE OF STRINGER
\A1;34" MIN. TO 36" MAX.
\A1;6" MIN.
IT-12 SC. 1-1/2" = 1'-0" TYPICALLY AT FOYER - NOTE: STAIR DESIGN MAY VARY BY PLAN / DIVISION / MFR
MODERN TRIM PACKAGE
STAIR AND BALUSTRADE DETAILS
\A1;41 1/4"\A1;TO FINISHED FLOOR\P(42" FOR MASTER BRAND)
\A1;1"\A1;16"
1/2" GYP. BD
OUTLET BOX PLACED HORIZ. - HOLD TIGHT TO TOP PLATESURFACE PER SPEC
SURFACE PER SPEC
IT-14 SC. 1-1/2" = 1'-0" AT KITCHEN
MODERN TRIM PACKAGE
BAR TOP at KNEEWALL
CASING
1/8"x2" STEEL STRAP AT 24"O.C. - SCREW TO TOP PLATE FOR TOP SUPPORT
\A1;{\H0.7x;\S3#4;\H1.4286x;" - 1 \H0.7x;\S1#4;\H1.4286x;" NOSING}
\A1;10" MIN.
\A1;7 3/4" MAX
\A1;6'-8" MIN. HEADROOM
\A1;1'-1{\H0.750000x;\S7#8;}" ROUGH DIM
{\LALTERNATE STARTING NEWEL}ALTERNATE
STARTING NEWEL
\A1;THIS NEWEL CAN ONLY BE USED AT THE BASE OF THE STAIR\P{\C6;VERIFY MIN. CODE CLEARANCES ARE MAINTAINED}
\A1;41 1/4"\A1;TO FINISHED FLOOR\P(42" FOR MASTER BRAND)
\A1;{\H0.7x;\S1#2;}" COVE MOLD
\A1;1x3 CASING
\A1;BALUSTER SPACING SUCH AS TO NOT ALLOW A SPHERE LARGER THAN 4" TO PASS THROUGH
\A1;1x8 CAP RIPPED
\A1;4{\H0.7x;\S3#4;}" FROM TOP OF STRINGER TO TOP OF KNEEWALL - ROUGH
\A1;1x8 END CAP RIPPED - TIGHT AGAINST END OF STRINGER
{\LDETAIL B .}DETAIL B .
\A1;1x8 CAP RIPPED TO 6 {\H0.7x;\S1#2;}"
\A1;1x3 CASING
\A1;{\H1x;BASE MOLD}
{\LDETAIL A .}DETAIL A .
\A1;1x8 END CAP RIPPED
\A1;3 {\H0.7x;\S1#2;}" NEWEL POST\A1;{\H0.7x;\S1#2;}" COVE MOLD\A1;BASE PER SPEC
\A1;STAIR STRINGER PACKED OUT {\H1x;5/8}" FOR DRYWALL\A1;TREAD
\A1;RISER\A1;TREAD\A1;RISER
\A1;1x3 STOP BLOCK
\A1;2" TREAD TO\PFACE OF NEWEL
\A1;6{\H0.750000x;\S1#2;}"
\A1;2" TREAD TO\PFACE OF NEWEL
\A1;3 {\H0.7x;\S1#2;}" NEWEL POST\PPOSITION MAY VARY PER DIVISION / MANUFACTURER / PLAN\PVERIFY CODE CLEARANCES REQUIREMENTS
HANDRAIL AND BALUSTRADE (WHERE PRESENT) SHALL BE CONSTRUCTED ACCORDING TO THE LATEST ADOPTED LOCAL CODES (TYPICALLY SECTIONS 311 AND 312).\P\PHANDRAILS THAT HAVE MIN. AND MAX. HGTS OF 34" AND 38", RESPECTIVELY, MEASURED VERTICALLY FROM THE NOSING OF THE TREADS, SHALL BE PROVIDED ON AT LEAST 1 SIDE OF STAIRWAY.\P\PALL REQUIRED HANDRAILS SHALL BE CONTINUOUS THE FULL LENGTH OF THE STAIRS W/ 3 OR MORE RISERS FROM A POINT ABOVE THE THE TOP RISER OF A FLIGHT TO A POINT ABOVE THE LOWEST RISER OF THE FLIGHT. ENDS SHALL BE RETURNED OR SHALL TERMINATE AT NEWEL POSTS OR SAFETY TERMINALS. HANDRAILS ADJACENT TO A WALL SHALL HAVE A SPACE OF NOT LESS THAN 1.5" BETWEEN THE WALL AND HANDRAIL.\P\PGUARDRAILS SHALL BE 36" MIN. ABOVE WALKING SURFACE.\P\PTHERE SHALL BE NO HORIZONTAL BALUSTER MEMBERS AND SPACING SHALL BE SUCH THAT A FOUR INCH DIAMETER SPHERE CANNOT PASS THROUGH
HANDRAILINGGUARDRAILING
2 X BLK'G.
AT OUTSIDE OF STAIRA
1 1/2"-2"
AT WALLB
1 1/2"-2"MIN1 1/2"
CPLAN
WALL BRACKET AT 4'-0" O.C. MAX.
WOOD BALUSTER SPACED AT 4" O.C., MAX.
RETURN TO WALL WHERE SHOWN, SEE PLANS
RESIDENTIAL GUARDRAIL: HEIGHT MEASURED ABOVE LANDING OR STAIR NOSING SHALL BE NO LESS THAN 34" AND NOT MORE THAN 38"RESIDENTIAL HANDRAIL: HEIGHT MEASURED ABOVE LANDING OR STAIR NOSING SHALL BE NO LESS THAN 34" AND NOT MORE THAN 38"
IT-13 SC. 3" = 1'-0" - INTERIOR STAIRWAYS
HANDRAIL DETAIL
10/10/22