HomeMy WebLinkAbout10422 CONNAUGHT DR, METHOD OF ATTACHING STRUCTURE TO FOUNDATION1'-4"1'-4"FLOOR JOIST LAYOUT SHEET
NOTES:
1.- 16" X 16" CONCRETE FOOTER 30" BELLOW GRADE.
2.- 6" X 4" TREATED POST.
3.- 2-2X10 TREATED HEADER
4.- 2X10 SOUTHERN PINE#2 FLOOR JOIST @ 16" O C
11
11
11
11
11
11
22
22
2-2X10 TREATED HEADER2-2X10 TREATED HEADER2-2X10 TREATED HEADER2-2X10 TREATED HEADER44
44
44
44
METHOD OF ATTACHING STRUCTURE TO FOUNDATION:
THE 6" X4" TREATED POST SETS IN THE 16" CONCRETE FOOTER;
THE 2-2X10 TREATED HEADER IS BOLTED TO THE 6" X4" TREATED POST
WITH 1/2 X 8" HILLMAN GALVANIZED COARSE THREAD HEX BOLT.
THE 2X10 FLOOR JOIST GOES ON TOP OF THE 2-2X10 TREATED
LAY OUT @ 16" O C AND FASTENED WITH 3" GALVANIZED NAILS
X
X
X
XX
X
X
X
GRADE
NOT IN SCALE:
GRADE 6" X 4" TREATED POST6" X 4" TREATED POST2-2X10 TREATED HEADER
2X10 SOUTHERN PINE#2 FLOOR JOIST @ 16" O C
METHOD OF ATTACHING STRUCTURE TO FOUNDATION:
10422 CONNAUGHT DR, CARMEL, IN 46032.
10/10/22