Loading...
HomeMy WebLinkAbout06050019 Site Plan (i '-'., Schneider This Plot Pion Prepared For. Pulte Homes Townhomes at GuOford Instrument , 200500080749 SEC 36, T1 BN, R3E HomOton County, Oay T wp. City of Carmel Block 6 Prepared Date: 03(29(2005 : By: AMA The Schneider Corpora.Uon 8901 otU Annue HlBlorle Fort Harrison Indlanapollil, Indiana 46218-103'7 317-626-7100 317-826-7200 FAX Note: This drawing is based on construction plans or record drawings, and is not based upon 0 field survey. The Schneider Corporation does not warrant the accuracy or sufficiency of this Information. Contractors should verify existing conditions prior to any construction. Any discrepancy found on this drawing should be reported to The Schneider Corporation Immediately. foiling to do so results in the cootroctors ossumpUon of all liabUity. -- """".. Landscape Arcl1ileeltn GIS 'US GeololJ Plot Plan Legend [QQQ;Q] Proposed Grades 000.0 Existing Grades _ 000.0-- Contour Grode * Approx. Loteral location -.' - Sanitary Sewer Lines -11'- Storm Sewer Lines - I,J - Water Service Lines - - - - - - - Sub-Surface Drain Lines . Manhole (Sanitary or Starm) . Beehive Inlet (storm) illI Curb Inlet (Storm) D End Section (Storm) ..... fire H~rant - 000 - 00 0 - Flow Line of swale - Bundlng line (BL / BSL) - - - - - - - Easement Line Pulte Homes Finished Floor Eievotion Informotion PAD=B50.0B FFE=B50.70 BLOCK 6 u ~ =~= U Assumed North Scale: 1" = 30' i.3"Q0c, TC,,8461) PER PLAN Note: Sanitary Sewer Top of Casting Information Upstream Manhole, TC=849.70 Downstream Manhole. TC=849.70 per plan, (,N '" q N (,N '" .3. " '" 0 "'z s:: "U"U s:: N~ 1\ o~o c....... oozp:>z toll-+=--Otn cn_~ ~C,.-.I rrl5:; !7JIo rr1 :::j OJ> N (,N '" 0>. N en o "'. 111. <& ~tRWMfj 15' SE ~ SlR.H 412 Note: The contractor Is to maintain a minimum distance of ten feet (10') between the sanitary sewer and water line laterals, NOTE: IN THE RESIDENTIAL DISTRICTS LIMITING HEIGHT TO TWENTY-FIVE (25) FEET. A DWELLING MAY BE INCREASED IN HEiGHT TO THIRTY-FIVE (35) FEET PROVIDED THE SIDE AND REAR YARDS ARE INCREASED AN ADDITIONAL FOOT FOR EACH FOOT SUCH STRUCTURE EXCEEDS TWENTY-FIVE (25) FEET IN HEiGHT. PER CARMEL ZONING ORDiNANCE 26.1.1. 26. :i :; b I ;.. TYPICAL SWALE SECTION . OJ> . LOT # - ADDRESS 601 - 11785 Harvard Lane 602 11781 Harvard Lane 603 11777 Harvard Lane 604 11773 Harvard Lane 605 11769 Harvard Lane 606 11765 Harvard Lane FLOOD HAZARD STATEMENT CERllF1CA llON :<.\\\\\\\\\\IllJ/III/I//1111. #'\" c. L /I 1/0% ~ "~..\';) . c.;Ph ~ ~,:".~, ............../r{//,~ If (~~ ,,;ro\s TE!?;:.., ~./I~ :;::: _'-i " v N "'0'. /"". ~ ~<:::''''<1- 0 ..."..0", @ f . \ ~ = , 50303 , = ~ ~ j ~ % ..... STATE OF ,/ iff ~ /'. . ~ ~<~>!.tyDIAt-\,:..""~# ~'11J .S....U..R.";,\:~ # ~//1. ., :<.,\~ '/1/II/fIf/!Jlln\\l\\\\\\\'1 ~lfi1 FLOOD HAZARD STATEMENT: The accuracy of any flood hazard data shown on this report is subject to mop scale uncertainty and to any other uncertainty In location or elevation on the referenced flood Insurance rate map (FIRM), All of the within described land DOES NOT UE within that special flood hazard zone A as said land plats by scale on flood insurance rote map # 18057C0209F for Hamilton County. Indiono (mop effective dale February 19, 2003).