Loading...
HomeMy WebLinkAbout06050020 As Built (I) (- , ) ~., Schneider This Plot Plan Prepored for. Pulte Homes Townhomes ot GuDford Instrument # 200500080749 SEC 36, 118N, RJE HomDton County, Cloy T wp. City of Conmel BlocIc 6 -'~-~Prepared Date: 03/29/2005 : -By: AMA The Schneider Corporation 8901 Otis Avenue Blstoric Forlllarrison Indianapolis, IndiaIlll 48216-1037 317-828-7100 317-826-7200 FAX -""'" - Landscape !rclrllecl.11nl GIS .US GeololY Note: This drawing is based on construction plans or record drawings, and is not based upon a field survey. The Schneider Corporation does not warrant the accuracy or sufficiency of this information. Contractors should verify existing conditions prior to any construction. Any discrepancy found on this drawing should be reported to The Schneider Corporation immediately; foiling to do so results in the contractors assumption of all liability. Pulte Homes Finished Floor Elevation Information PAD=B50.0B FFE=B50.70 Plot Plan legend [QQ[Q] Proposed Grades 000,0 Existing Grades _OOO.O~ Contour Grade * Approx. Lateral Location - . - Sanitary Sewer Lines . -;r ---.' StOi'lil Sener Lines - VI - Water Service Lines - - - - - - - Sub-Surface Drain Lines . Manhole (Sanitary or Storm) .. Beehive Inlet (Storm) II1II Curb Inlet (Storm) D End Section (Storm) ..... Fire Hydrant - 000 _ 000 - Flaw Line of swale - - Building Une (BL ! BSL) - - - - - - - Easement line ~ o =~= ~ Assumed North Scale: 1. = .30' BLOCK 6 <ri '" '" Note: Sanitary Sewer Top of Casting Informatioo Upstream Manhole, TC= 849.70 Downstream Manhole, TC= 849.70 per plan. CA 65.4 850.0 1.6' 40.67 67.92 - ~;J~tl ~ O'l \lIJI: ~ ..., ~ C"l::l 9 SR- ~:!: ~ ~~ ~I: ~ U!. I'll:> ~ '" 74.2 ' 2.00 >:tb '" ia~~" ~ ?ii~ 2 ij): 0 ~ ~ .li~ f'l~ '" 'l6" 74.2 06 ~ ;!; ~ ~ '" '" '" '" a ~ '" 10.5' -.\9 '" '-" 26. <0 '" NOTE: IN THE RESIDENTIAL DISTRICTS LIMITING HEIGHT TO TWENTY-FIVE (25) FEET, A DWELLING MAY BE INCREASED IN HEIGHT TO THIRTY-FIVE (35) FEET PROVIDED THE SIDE AND REAR YARDS ARE INCREASED AN ADDITIONAL FOOT FOR EACH FOOT SUCH STRUCTURE EXCEEDS TWENTY-FIVE (25) FEET IN HEIGHT. PER CARMEL ZONING ORDINANCE 26.1.1. z :;; . o 4: 1 SlOPE ~ 4'. \ SLOPE TYPICAL SWALE SECTION I ::; ia~iJi~ I '" ~ o~ 0 ij)"~ ~ '-" I ~.E <0 W. :1 ~~~ '" f'l1!i 10.5' "'. :z: ....J 74.25 n . 42.61 <t: I <c 0 C) -.Jw - ill~~" 10.5' Oz s::: 0:: ;;l"" s::: 0 * '" 0 ,......, 1I0~O <c ~ o~ 0 ij).. ~ ~ 0.1 CXlzRoZ n:::: ~ ~ .... f'l'" ill. (,011 ~o(/) I <t: :z: .I'l~ ~ ~~mt...ll"Tl5:i 0 r> ~l ~o rr1 In:::: -...J )> I <t: - ill~ilitl . I :r:: ~ '" $'" N )> "'~~ ~ ij).. '-" . I <0 I 1:ll ~e;; "'. I ~ ~ 10.5' ~ loa 24.0' - ill~~" 10.5' I ACCESS ~?:;~g~:O ~ ~ N ESUl. '" I '" U\ a a . >..., ~~ q I '"?o I >!~ 1.9' 42.67' 850.0 I! I ~!ii LOT # - ADDRESS 601 11785 Harvard Lane 602 11781 Harvard Lane 603 11777 Harvard Lane 604 11773 Harvard Lane 605 11769 Harvard Lane 606 11765 Harvard Lane 15' SE FLOOD HAZARD STATEMENT CERllFICA llON ~\\\\\\\\II\lIIIIJll/flllll//, -#" c. L /'l/"/I/<<: ~""";) v:.o/,~ ~ ...~'\ "'"'''''''' "r(//",~ $ ~",'~G\S TE"R~"",""....<'% $<:::;,.....'" No. 0.......-<'% I 50303) I % . STATE OF ..... iff ~ ./". .,' ~ ~ (".-.t ....:,/yOJ At\,~.'" ~~ % '1tJ 'S""U"R'A.. ~ # ~//I 'i ~~ 11/II//fl/llllll\\\\\\\\\\'\ TC=849A70 PER PL .N "-., STR,H 412 Note: The contractor Is to maintaIn a minimum distance of ten feet (10') between the sonitary sewer and water line laterals. '\::l'- l . P11 flOOD HAZARD STATEMENT: The accuracy of any flood hazard dota shown on this report is subject ta map scale uncertainty and to any other uncertainty in location or elevation on the referenced ~ood insurance rate map (FIRM). ALL of the within described land DOES NOT UE within that special flood hazard zone A as said land plots by scale on flood insurance rate map I 18057C0209F for Hamilton County, Indiana (mop effective date February 19. 200.3).