HomeMy WebLinkAboutS1FLOOR PLAN PRE-ENGINEERED ATTIC ROOF TRUSSES
SEE ENGINEERED TRUSS PLANS PER MANUFACTURER FOR EXACT DESIGN
2X6 RAKE FASIA
2X6 FASIA
10' CEILING
2X6 FRAMING FOR ALL WALLS 24" OC
FOUNDATION MONOLITHIC SLAB WITH FOOTING
9' WIDE X 8'6" HIGH
OVERHEAD DOOR
100 AMP SUB PANEL
SITE VERIFY LOCATION
BUILDING SECTION
-DIMENSIONAL SHINGLES
-30LBS ROOF FELT OR EQUIVELENT
-7/16" OSB
-PRE-ENGINEERED ROOF TRUSS
-7/16" O.S.B
-HOUSE WRAP
-SIDING PER OWNER
GARAGE FLOOR PLAN AND ROOF TRUSS PLAN HOLDCRAFT GARAGE PLANSS1
4" MIN CRUSHED FILL
4" MIN CONCRETE SLAB
2"X6" TREATED PLATE
1/2" X 10" ANCHOR BOLT @ 48"O.C.
PLASTIC SHEETING
2 ROWS OF CONTINUOUS #4 REBAR
R-10 POLY SHEET TO
2' BELOW GRADE
MONOLITHIC SLAB WITH FOOTINGS
FINISHED GRADE
10/17/22