HomeMy WebLinkAboutA002FLOOR LINEUNDERSIDE OF STRUCTURECEILING LINEW2ACOUSTICAL BATT INSULATION3-5/8" INTERIOR METAL FRAMINGAT 16" O.C.CONTINUOUS METAL RUNNERDEFLECTION TRACK5/8" GYPSUM WALLBOARD EACH SIDE.USE TYPE X AT RATED ASSEMBLIESCONTINUOUS METAL RUNNER TRACKACOUSTICAL SEALANT AT PERIMETEROF BOTH SIDESW7CW7AW7ACOUSTICAL SEALANT ATSTRUCTURAL DECKHOLD GYPSUM BOARD1/2" ABOVE F.F.W1ACOUSTICAL BATT INSULATION3-5/8" INTERIOR METAL FRAMINGAT 16" O.C.CONTINUOUS METAL RUNNERDEFLECTION TRACK5/8" GYPSUM WALLBOARD AT ROOMSIDE. USE TYPE X AT RATED ASSEMBLIESCONTINUOUS METAL RUNNER TRACKACOUSTICAL SEALANT AT PERIMETEROF BOTH SIDESW8CW8AW8ACOUSTICAL SEALANT ATSTRUCTURAL DECKHOLD GYPSUM BOARD1/2" ABOVE F.F.01A00202A002 HEAD AT CEILING SCALE: 3/4" = 1'-0"01 GYPSUM PARTITIONDWGS AND INTERIORANCHOR TO MAIN CEILINGAT 4'-0" O.C.RUNNER (4) DIRECTIONSBRACING PLANE OF MAIN*$63/$<:,5(PANEL CEILING. REFERSCHED ACOUSTICALCEILING TEE. DO NOTANCHOR RUNNER TOCEILING TEE TYPICALBETWEEN RUNNER ANDCOMPRESSIBLE GASKETFOR PARTITION TYPEREFER FLOOR PLANSCHED FOR THICKNESSREFER PARTITIONSTRUCTURE ABOVEDRAWINGS.RUNNER.AT 4'-0" O.C. TOALTERNATING SIDESCFMF BRACESPROVIDE DIAGONALAT 4'-0" O.C.12 GA. VERTICALAT EACH PL. (2) PER PL.#12 SHEET METAL SCREWVERT. MOVEMENT TYP.SECURE CONT. TRACK ATDEEP LEG CFMF TRACKPROVIDE FOR 1"@16" O.C.3"X1'-3" 16 GA. PL.AT EACH END OF PLATE.POWDER DRIVEN FASTENERPERPENDICULAR TO STRUCTUREFOR PARTITION TYPEREFER FLOOR PLANREFER PARTITION SCHEDPARALLEL TO STRUCTUREFOR THICKNESSNOTCH GWB ATC SHAPE FOR 1"VERT. MOVEMENTFLUTE. (2) PER FLUTE.AT EACH LOW END OFPOWDER DRIVEN FASTENERSTRACK. SECURE USINGDEEP LEG CFMF CONT.LINE OF METAL DECK/WHERE OCCURSCONCRETE SLABANGLE CLOSURES WELDED TOFLUTE TO FLUTE METALDECKING CONDITION.PROVIDE FOR 1" VERTICAL MOVEMENT.REFER FLOOR PLANFOR PARTITION TYPEREFER PARTITION SCHEDFOR THICKNESSVERTICAL STUDS ONLYSCREW GWB TOMETAL DECK/CONCRETESLAB WHERE OCCURS02 GYPSUM PARTITION HEAD AT STRUCTURESCALE: 3/4" = 1'-0"01A00202A002UL U4691 HOUR RATED CEILING2 HOUR RATED CEILINGUL U438 CEILING ASSEMBLIESSCALE: 3/4" = 1'-0"03 HORZ. SHAFTWALLCONCRETEMASONRY UNITS-REFER TO PLANS FORSIZECONCRETEMASONRY UNITS-REFER TO PLANS FORSIZEI-STUD24" O.C.1" FIRE-SHIELDSHAFTLINERJ TRACKI-STUD24" O.C.1" FIRE-SHIELDSHAFTLINERJ TRACK5/8" FIRE-SHIELDGYPSUM BOARD(2) LAYER 5/8"FIRE-SHIELDGYPSUM BOARDW3ACOUSTICAL BATT INSULATION3-5/8" INTERIOR METAL FRAMINGAT 16" O.C.CONTINUOUS METAL RUNNERDEFLECTION TRACK5/8" GYPSUM WALLBOARD EACH SIDE.USE TYPE X AT RATED ASSEMBLIESCONTINUOUS METAL RUNNER TRACKACOUSTICAL SEALANT AT PERIMETEROF BOTH SIDESW7CW7AW7ACOUSTICAL SEALANT ATSTRUCTURAL DECKHOLD GYPSUM BOARD1/2" ABOVE F.F.01A00202A002SHAFTWALLWTWHGENERAL WALL NOTES:WALL TYPEHEIGHT ATTRIBUTES( EXTEND WALL TO STRUCTURAL DECKU.N.O.)A = EXTEND WALL TO 6" ABOVE CEILING.C = EXTEND WALL TO CEILING.(DENOTES WALL TYPES ON PLAN)WALL TAG:A.ALL DIMENSIONS ARE TO FACE OF MASONRY OR FINISH FACE OF GYPSUM BOARD.B.FIELD VERIFY ALL EXISTING CONDITIONS: ALL NEW WALLS ABUTTING EXISTING WALLSSHALL MATCH EXISTING CONDITIONS.C.PROVIDE BULLNOSE CONCRETE MASONRY UNITS AT ALL NEW EXPOSED WALLOPENINGS, WINDOW OPENINGS, DOOR AND CORNERS UNO. REFER TO DOORDETAILS FOR INSTALLATION OF BULLNOSE AT DOOR OPENINGS.D.PROVIDE METAL TRIM AT THE EDGES OF ALL GYPSUM WALLBOARD WHERE IT ABUTSANOTHER MATERIAL AND WHERE EDGES ARE EXPOSED TO VIEW.E.DIVIDE ALL GYPSUM WALLBOARD AREAS WITH CONTROL JOINTS NOT EXCEEDING 30FEET IN EITHER DIRECTION OR AS SHOWN OTHERWISE. CONFIRM LOCATIONS WITHARCHITECT PRIOR TO INSTALLATION. PROVIDE RATED CONTROL JOINTS IN FIRE RATEDPARTITIONS.F.PROVIDE MASONRY REINFORCEMENT IN ALL SINGLE AND MULTIPLE WYTHE WALLS ANDPARTITIONS PER STRUCTURAL DRAWINGS.G.APPROPRIATE RATED FIRE DAMPERS ARE REQUIRED IN DUCTS WHICH PENETRATE RATEDPARTITIONS. DUCTS, PIPES AND CONDUIT MUST BE SEALED AT PERIMETERS WHEREPENETRATIONS THRU RATED PARTITIONS OCCUR. REFER TO MECHANICAL DOCUMENTS.H.ACOUSTICAL SEALANT IS REQUIRED AT THE PERIMETER OF ALL WALLS (HEAD/SILL)INCLUDING EXISTING WALLS.J.PROVIDE TILE BACKER BOARDS AT METAL STUD PARTITIONS SCHEDULED TO RECIEVEWALL TILE.STANDARD SYSTEMSSHAFTWALL SYSTEMSNOTE: * = AT FRAMING EXCEEDING 12'-0" HEIGHT, PROVIDE BRACINGLINTEL SCHEDULE U.N.O.FRAMING1 5/8"2-1/2"2-1/2"2-1/2"3-5/8"3-5/8"3-5/8"6"6"6"2-1/2"C-H STUDS2-1/2"C-H STUDS2-1/2"C-H STUDS4"C-H STUDS4"C-H STUDS6" DBLE STUDS6" DBLE STUDS</= 6'-0"> 6'-0" - </= 8'-0"> 8'-0" - </= 10'-0"DEPTHAT MID HEIGHT LOCATION, BUT NOT TO EXCEED 12'-0" MAX.SPAN25--(0.0179")25--(0.0179")22--(0.0270")20--(0.0329")25--(0.0179")22--(0.0270")20--(0.0329")25--(0.0179")22--(0.0270")20--(0.0329")25--(0.0199")22--(0.0294")20--(0.0341")25--(0.0199")20--(0.0341")25--(0.0199")20--(0.0341")FRAMING
GAUGE
STUD 16" 24" 16" 24" 16" 24" 16" 24" 16" 24" 16" 24" 16" 24" 16" 24" 16" 24" 16" 24" 24" 24" 24" 24" 24" 24" 24"2-4"X16GA. METAL CEE STUDS2-6"X18GA. METAL CEE STUDS2-6"X16GA. METAL CEE STUDSSPACING
ALLOWABLE L/240 L/240 L/240 L/240 L/240 L/240 L/240 L/240 L/240 L/240 L/240 L/240 L/240 L/240 L/240 L/240 L/240 L/240 L/240 L/240 L/240 L/240 L/240 L/240 L/240 L/240 L/240LINTEL SIZEDEFLECTION
FURRING2 HOUR
1 LAYER8'-3"7'-3"11'-0"9'-9"12'-0"10'-6"13'-0"11'-6"14'-6"12'-9"16'-0"14'-0"17'-3"15'-0"20'-0"15'-0"25'-3"22'-0"26'-6"23'-3"RATED12'-1"14'-11"15'-3"16'-11"18'-2"26'-3"28'-0"ONE SIDE*
PARTITION1 HOUR
1 LAYER9'-6"8'-3"12'-6"10'-9"13'-0"11'-6"14'-0"12'-3"16'-0"13'-6"17'-3"15'-0"18'-3"16'-0"20'-0"15'-0"26'-0"22'-9"27'-6"24'-0"RATED11'-8"13'-7"14'-0"15'-10"17'-6"25'-3"28'-0"EACH SIDE
PARTITION
2 LAYERS10'-6"8'-9"13'-6"11'-3"14'-0"12'-3"14'-9"13'-0"16'-9"13'-6"18'-0"15'-9"19'-0"16'-6"20'-0"15'-0"23'-9"20'-9"25'-6"22'-3"EACH SIDE
LACQUISCONSULTING ENGINEERS9229 DELEGATES ROW, SUITE 550INDIANAPOLIS, IN 46240317.706.2075WWW.LACQUIS.COMA002RAR-19400087EAR-19400087ER
TE
GISTE
GISRRAAHCITHCITRR
DNAD
No.No.GDI
DEWREREECECT
IHDDETWEMay 13, 2011P:\ACTIVE PROJECTS\11021 - Carmel Bldgs - LAcquis\03 CD\City Hall\DWG\A002.dwg, 5/20/2011 8:47:14 AM, Bid and Permit