Loading...
HomeMy WebLinkAboutS-301 - TYPICAL FOUNDATION DETAILSNOTES: 1) THE SCHEDULE INCLUDES SPLICE AND DEVELOPMENT LENGTHS WHICH SATISFY THE PROJECT REQUIREMENTS AND THE FOLLOWING CRITERIA: fy = 60,000 psi (75,000 psi FOR #14 AND #18 BARS). CONCRETE WEIGHT = 150 lb/cu.ft. TENSION DEVELOPMENT AND LAP SPLICE LENGTHS ARE DIVIDED INTO TWO CATEGORIES WHICH SHALL BE APPLIED AS FOLLOWS: CATEGORY I CLEAR SPACING OF BARS BEING DEVELOPED OR SPLICED NOT LESS THAN db, CLEAR COVER NOT LESS THAT db, AND BEAM STIRRUPS OR COLUMN TIES THROUGHOUT Ld NOT LESS THAN THE CODE MINIMUM OR CLEAR SPACING OF BARS BEING DEVELOPED OR SPLICED NOT LESS THAN 2db & CLEAR COVER NOT LESS THAN db. CATEGORY II BARS NOT COVERED BY CATEGORY I 2) USE COMPRESSION LAP SPLICE LENGTH (LCS) AT ALL COLUMN SPLICE LOCATIONS NOT SPECIFICALLY DETAILED AND UNLESS INDICATED OTHERWISE ON PLANS OR DETAILS. USE TENSION LAP SPLICE LENGTH (LTS) FOR ALL OTHER SPLICES (UNLESS OTHERWISE SHOWN ON DRAWINGS). 3) THE STANDARD LAP SPLICE (0.0005 X fy X D) IS USED FOR COMPRESSION SPLICES AND THE CLASS "B" SPLICE IS USED FOR TENSION SPLICES. THE CONTRACTOR MAY SUBMIT LESSER SPLICE LENGTHS FOR REVIEW AND APPROVAL AT THE SAME TIME PROVIDING THE FOLLOWING INFORMATION. A. DETAILS PREPARED AND SUBMITTED BY THE CONTRACTOR INDICATING LOCATION AND PROPOSED LAYOUT OF REBARS AND LENGTHS OF SPLICES. B. WHERE THE SIZE AND NUMBER OF TIES OR SPIRALS PERMIT THE REDUCTION OF LAP LENGTH, THOSE BARS SHALL BE INDICATED ON THE DETAILS. C. WHERE COMPUTED STRESS VALUES PERMIT THE REDUCTION OF LAP LENGTH, COMPUTATIONS SHALL BE SUBMITTED FOR REVIEW. D. THE APPLICABLE SECTION OF THE ACI CODE PERMITTING THE LESSER SPLICE LENGTH SHALL BE INDICATED ON THE SUBMITTED MATERIAL. 4) TOP BARS ARE HORIZONTAL BARS PLACED SO THAT MORE THAN 12 INCHES OF CONCRETE IS CAST IN THE MEMBER BELOW THE BAR. 5) WHERE BARS OF DIFFERENT SIZE ARE TO BE SPLICED, THE SPLICE LENGTH FOR ALL BARS SHALL BE THAT REQUIRED FOR THE LARGEST. 6) WHEN LIGHTWEIGHT CONCRETE IS USED, THE VALUES LISTED IN THE TABLE FOR TENSION DEVELOPMENT + LAP SPLICE LENGTHS SHALL BE INCREASED BY 30%. 7) WHEN REINFORCING BARS ARE EPOXY-COATED, ALL VALUES IN THE TABLE SHALL BE INCREASED BY 50%. 8) COMBINATIONS OF EFFECTS DUE TO CONCRETE WEIGHT AND EPOXY BARS ARE CUMULATIVE. LD SHALL BE MULTIPLIED BY EACH FACTOR TO FIND THE CORRECT VALUE. 9) ACI DOES NOT PERMIT LAP SPLICES OF #14 OR #18 BARS. BARS OF THIS SIZE SHALL BE COUPLED BY ACCEPTABLE MECHANICAL MEANS, WHICH ARE RATED TO DEVELOP 125 PERCENT OF Fy OF THE BAR. #3 #4 #5 #6 #7 #8 #9 #10 #11 BAR SIZECOMPRESSION DEVELOPMENT LENGTHSTANDARD LAP SPLICE LENGTH12 15 19 23 27 30 34 39 43 8 11 14 17 19 22 25 28 31 TABLE OF DEVELOPMENT AND LAP SPLICE LENGTH (IN INCHES) #18 #14 38 50 NOTATIONUSED ONDWG.LCD LCS LD LTS 16 12 20 15 25 19 30 23 44 34 50 39 57 44 64 49 101 78 CATEGORYSEE NOTE 123 30 38 45 66 76 85 96 152 17 29 23 39 29 49 35 59 51 86 58 98 66 111 74 125 117 138 20 26 33 39 57 65 74 83 92 23 38 45 66 76 85 96 106 30 16 25 30 44 50 57 64 71 20 I II I II I II I IICATEGORYSEE NOTE 1CATEGORYSEE NOTE 1CATEGORYSEE NOTE 1TOP BARSOTHER BARSTOP BARSOTHER BARSTENSION (f'c = 6,000 psi) 22 17 29 22 36 28 43 33 63 48 72 55 81 62 91 70 101 78 CATEGORYSEE NOTE 133 43 54 64 94 107 121 136 151 25 43 33 56 41 70 50 84 72 122 82 139 93 157 105 177 116 196 29 37 47 56 81 93 105 118 131 19 14 31 24 37 28 54 42 62 48 70 54 78 60 87 67 28 46 55 81 93 104 117 130 25 19 37 21 36 28 48 36 60 43 72 62 105 72 121 80 136 90 153 100 170 24 36 40 48 70 8190 102 113 25 17 37 33 54 48 62 55 70 78 87 37 55 81 93 104 117 130 19 28 31 28 46 25 19 41 32 50 38 72 56 83 64 13 21 25 37 42 22 17 43 33 63 48 72 55 78 60 32 65 94 108 117 36 28 54 25 41 50 72 83 90 33 54 64 94 107 121 136 151 43 22 36 43 63 72 81 91 101 29 I II I II I II I II I II I II I II I II I II I II I II I II CATEGORYSEE NOTE 1CATEGORYSEE NOTE 1CATEGORYSEE NOTE 1TOP BARSOTHER BARSTOP BARSOTHER BARSTENSION (f'c = 3,000 psi) CATEGORYSEE NOTE 1CATEGORYSEE NOTE 1CATEGORYSEE NOTE 1CATEGORYSEE NOTE 1TOP BARSOTHER BARSTOP BARSOTHER BARSTENSION (f'c = 4,000 psi) CATEGORYSEE NOTE 1CATEGORYSEE NOTE 1CATEGORYSEE NOTE 1CATEGORYSEE NOTE 1TOP BARSOTHER BARSTOP BARSOTHER BARSTENSION (f'c = 5,000 psi) 62 47 92 71 120 80 62 92 70 54 105 81 137 91 70 105 71 54 106 82 LD LTS LD LTS LD LTS 22 17 32 25 42 28 32 22 DEVELOPMENT LENGTH LAP SPLICE LENGTHDEVELOPMENT LENGTH LAP SPLICE LENGTH DEVELOPMENT LENGTH LAP SPLICE LENGTH DEVELOPMENT LENGTH LAP SPLICE LENGTH (IN INCHES) TABLE OF HOOKED BAR DEVELOPMENT LENGTHS BAR #3,000 psi f'c 4,000 psi 5,000 psi 3 6 6 6 4 8 7 6 5 10 9 8 6 12 10 9 7 14 12 11 8 16 14 12 9 18 15 14 10 20 17 16 11 22 19 17 NOTES: 1) CONCRETE SIDE COVER ON BARS ¢ 2.5". 2) FOR EPOXY-COATED BARS, MULTIPLY TABULATED VALUES BY 1.3. 4d #3 - #812 dbdbb 5d #9, #10, #11 6d #14 b b 2'-2 1 /2"dhdb4d ¢ 2 1/2"b START OF DEVELOPMENT 6,000 psi 6 6 7 9 10 11 13 14 16 l dh l 14 33 29 26 23 TYPICAL CONCRETE COLUMN 4 BARS 6 BARS 8 BARS 10 BARS OR MORE ROUND COLUMN L SHAPED COLUMN a a a SEE NOTE 1 (TYP.) INTERMEDIATE TIES (TYP.) SEE NOTE 1 (TYP.)NOTES: 1) FOR CLEAR DISTANCE BETWEEN VERTICAL BARS OF a < 6" ALTERNATE INTERMEDIATE TIES MAY BE OMITTED. 2) TOTAL NO. OF BARS SHOULD BE SPACED AROUND PERIMETER IN SUCH A WAY AS TO ACHIEVE APPROXIMATELY EQUAL SPACING. 3) THE ABOVE DETAILS APPLY ALSO AT PIERS. 4) MIN. CLEAR VERTICAL BAR SPACING SHALL BE PER REINFORCEMENT DEVELOPMENT LENGTH TABLE. 5) ALTERNATE THE LOCATION OF THE 90° AND 135° HOOKS ON SUCCESSIVE SETS OF TIES. 6) SEE TABLE OF COLUMN TIE SPACING THIS DRAWING.LTSa a a TYPICAL DETAIL OF CONCRETE COLUMN VERTICAL REINFORCEMENT @ FOOTING FIN. FLR. EL. (SEE PLAN) ® COLUMN & FOOTING ISOLATION JOINT 3" CLR. ENCASE COLUMN w/ MIN. 3" OF CONC., SAME STRENGTH AS SLAB FOOTING SIZE, REINF. & EL. SEE PLAN/SCHEDULE FOR 3" 3" DOWELS TO MATCH VERT. REINF. (U.N.O.) 0" (TYP.) 1 ' - 0 " SCHEDULED TIE U.N.O.LTS3" MAX.1'-0"MIN.U.N.O.TYPICAL CHANGE IN WALL THICKNESS PLAN LTS 2" MAX.TYPICAL DETAIL - REINFORCING FOR CONCRETE WALLS NOTES: 1) LTS PER TABLE OF LAP SPLICE LENGTHS. 2) SEE PLANS AND SECTIONS FOR SIZE AND SPACING OF REINFORCEMENT AND WALL THICKNESS. AT CORNERS PLAN VIEWS (TWO LAYERS) AT WALL INTERSECTIONS AT WALL INTERSECTIONS PLAN VIEWS (ONE LAYER) AT CORNERS ALTERNATE BARS(TYP.) LTS (TYP.)LTS(TYP.)LTS(TYP.)LTS(TYP.) LTS DETAIL OF VAULT CONCRETE COLUMN VERTICAL REINFORCEMENT @ FOOTING ® COLUMN & FOOTING 3" CLR.FOOTING SIZE, REINF. & EL. SEE PLAN/SCHEDULE FOR 3"3 " DOWELS TO MATCH VERT. REINF. (U.N.O.) 0" (TYP.) 1 ' - 0 " SCHEDULED TIE U.N.O.LTS3" MAX.TYP. 2" CLR WATERSTOP 2" CLR SYNKO-FLEX WATERSTOP AROUND ENTIRE PERIMETER SHEET TITLE SHEET NUMBER KITE Realty Group 30 S. Meridian Street, #1100 Indianapolis, Indiana 46204 Owner Republic Airways Holdings RATIO 101 South Pennsylvania Street Indianapolis, Indiana 46204 317-633-4040 Architect McComas/O'Donnell & Naccarato Structural Engineer Civil Engineer 8909 Purdue Road, Suite 300 Indianapolis, Indiana 46268 450 East 96th Street, Suite 175 Indianapolis, IN 46240 317-580-0402 Kimley Horn 250 East 96th Street, Suite 580 Indianapolis, Indiana 46240 PROJECT NO. SHEET ISSUE SEAL | DATE COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE, DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED. 450 EAST 96th STREET, SUITE 175, INDIANAPOLIS, IN 46240 (317) 580-0402 | WWW.O-N.com | Project No. 7167.0013.00 FOUNDATION PERMIT 07/08/2022 F.A. Wilhelm Construction 3914 Prospect Street Indianapolis, Indiana 46203 317-359-5411 Construction Manager Mechanical / Electrical/ Plumbing Engineer CIRCLE DESIGN GROUP 9229 Delegates Row #150 Indianapolis, Indiana 46240 BIM 360://22014-Republic Airways HQ/Republic_Garage-STRC-V21.rvt7/8/2022 3:35:41 PMS-301 TYPICAL FOUNDATION DETAILS 21040.000 REPUBLIC CAMPUS - PARKING GARAGE 12195 N. Meridian St. Carmel, Indiana 46032 Section S-301 1 1 FOUNDATION PERMIT 07/08/22 07/08/22 08/09/22