Loading...
HomeMy WebLinkAbout06050091 Site Plan , ~~ Scmeider The Schneider Corporation lWOlot.i1AftlllWl :m.tori.e fort Huri80n h"II.""P"'H~, fDdiIma 482l8-103'1 317-828-7100 Sl7-U2lI-7200 fa ~ - I.uWoopo - am .us GeoIoIJ Plot Plan L8Qend I 000.0 I P"'I'osed Grad.. 000.0 Existing GnIdes __ 000.0-- Contour Grade * Approx. Lateral location - . - Sanitary Sewer Liles - ar- Storm Sewer Liles -'tI-WoterSeriiceLines - - - - - - - Sub-Surfoce Drain lines . t.lonhole (Sanitary or Storm) . 8ee11lve Inl.t (Storm) IllD Curt> Inl.t (Storm) D End Sectioo (Storm) .... Fire Hydrant - ...... - ...... - Flow Une of swole This Plot Pion Prepared For: ~I HIlNES Lot' 62. containing 6,020 S.F.:f:, r.. 8ROOKSTONE PARK OF CAR~EL Section 1 2 Instrument 1 200300060432 P.C. 1 3, Side 1194 HAMILTON COlJNTY, ClAY TOWNSHIP 14526 8AUl\\1N LINE (50' R/W) Coomel, IN 46032 Prepared Oote: 04/27/06 : 8y.. KAG Community Restrictions: Side Yard: 3' Rear Yard = 20' A99regote . 6' (8.H.) Zoning = 51 ~/I Homes Finished Floor Elevation Information Pod Grode = 906.5 per plan Pod Grode + 0.2' = Garage FIT (906.7) Garage FIT + 0.5' = Residential FIT (907.2) Residenc. FIT - 9.0' = Basement FIT (B9B.2) Note : The garage finished floor e1evotion is 1.3' abo\'e the ClJrb at the driye, per pion. GROUND COVER CALCULATIONS: Drive = 637 SF" Public Walk =176 SF" Privete Walk =N/A SF" Seeding =2,367 SF" Sod =183 SYI, from rear of residence. 903.9 0"> o N 0_ FLOOO HAZARD STATEMENT CERTlFICA TlON ~\\\\\\\\\l11l111lf1l1111/, #\\V,c. L ~:~ #" ~~ ...........v,.,..~~ ~~.tG\s TE~~.......".A~ ~<::::) ,'"i(.. No O'...;<:>~ f ( 50303 ) , c::;: ~ . ::::; ~ . : ~ ~ .... STATE OF"" if2 ~ <..... I to- ,"a. fg ~ ..fA>..'YD'A~....'~"~~ ~:'!! 'S'U'R~~~ "///1/1//1/111111\\\1\\\1" ~lrv Note: Sanitary Sewer Top of Costing Information Upstream ~anhole, TC= 905.40 Downstream Manhole, TC=901.10 per plan. Note: The contractor is to maintain 0 minimum distance of ten feet (10') between the sanitry sewer and water line laterals. 906.0 100.33 to.OO' ~ !!! o <= < ~ 32.8' u !O>~ :zi~ ~""" ~Il:~ 2.00 JQ. . 904.2 37.L 100.33' >- ~ ::l. X~ NLo..: Flood Hazard Statement The accuracy of any flood hazard doto shown on this plot plan is subject to mop scole uncertainty and ~o any other uncertainty in location or elevation on the referenced flood Insurance rote mote (ARM). None of the within descrbed land lies within that special flood hazard zone -A-, os said land plots by scote on Community Mop Number' 18057C0206F of the flood insuronce rote mops (n~) for Hom~too County, Indiana, Doted February 19, 2003. Note: This drawing is based on construction plans or record drawings, i ond is nat bosed upon a field survey. The Schneider Corporation does not wOlTant the accuracy or sufficiency of this information. Contractors should verify existing conditions prior to any , construction. Any discrepancy found on this drawing should be reported to The Schneider Corporation immediately, foiling to do so results in the contractors assumption of all liability. Note: The basement e1evotion, depicted hereon, hos been determined and based upon the pad grades ond/or contours token from the construction plans for this subdivision. Unless stoted, no information about fluctuating water tables, son conditions. or son t)pes has been provided or stated on said pions. It is recommended that the basement finished floor e1eYOtions be at least two feet (t). above the normal pool elevation of any adjoining bodies of water, unless 0 study of facts reveals otherwise. If during the excavation pr~ onygr~nd w,atef' is witnessed, The Sc::hneider Corponition should be notified immediately. The basement e1evotion should be raised two feet (t) above the ground water, and additional construction techniques should be incorporated to alleviate future problems. Note: Sump pump(s) to be placed by bunder os needed. Lot # 52 VB05.0053281 D ~ =~= D Assumed. North , Scale: 1 = 30 I , I I 1 , 28.0' I B-B ,. I I , u.-o 1 , 1:2' ~ I \~:i \<:( \ I II ~ --I I \ [j~ \ ~ Z ~ \~ \~ \ \<1 \0 \ 1 ---l 1 I <:( , 6.0' CD \ PlANt ~ 1 , I , I I , , I 1 1 I 1 1 \ 22.6 \ .~ ~ \ \- \~: 15\"'" 'c '" <> \r\~ · 5 905.B \ 9 5.5 37.4 26. ~HI108 TC=901.10 PER PlAN Deta. of t)llicol Storm Water flow pattern for individual'lots. [Q] -:'M- -~- - - -- Note: Bunder to ensure positive drainage away from struture(s). ~ ~ ~ ~ \ ~. 'i b "q J ~ po It: TYPICAl SWALE SECllON Note: Per Connel zoning ordinance 26.1.1 : The residential district limits height to twenty-five feet {25'}, however 0 dwelling may be increased in height to thirty-five feet (35') provided the side and rear )(Irds ore increased on additional one foot (1') for each one foot (1') the structure exceeds the first twenty-five feet (2S') in height.