Loading...
HomeMy WebLinkAbout06050113 Site Plan 50.00 c= .43 I""") PER PtJ.N isni~~ c> r- Flood Hazard Statement: The accuracy of any flood hazard data shown on this report is subject to map scale uncertainty and to any other uncertainty in location or elevation on the referenced flood insurance rate map. ALL of the within described land DOES NOT lie within that special flood hazard zone AE as said land plots by scale on flood insurance rate map #1800810205 F for the City of Carmel, Indiana dated February 19, 2003. ~ The Schneider CorporaUon 8001 Otia Avenue Historic rort He.rriJon Indianapolls. Indiana l62l1-1037 317-826-7100 317-ll21-72oo FAX EDIlneerin( SurveJin& Landlcape Archlleclure GIS 'US Geolol1 I Plot Plan Legend This Plot Plan Prepared For: R.H. of Indiana [QQ[Q] Proposed Grades Lot # 961 , containing 7,000 SJ.:t, 'n 000.0 Existing Grades Village of Westday .--000.0- Contour Grode Sect. I 6002 * Approx. Lateral Location Ion _ . _ Sanitary Sewer lines INSlRUt.lENT I 200500080673 -... - Storm Sewer Unes PC E SUOE 791 - ~ - Water Service Un.es . - - - - - - - Sub-Surface DraIn Lines HamBtan County, Qay Twp . Manhole (Sonitaryor Storm) Sec 19, TIaN, ROJE . Beehive inlet (Storm) 2517 Buckland Street (50'R/W) ~ ~~~ ~~~~~o~SI~~~) Carmel, IN 46074 ..... Fire HyOront Prepared Date: 05/04/06: By. AMA - .. 0 - 0.0 - FI~w Une .of swale P sed B ....1 ). INVENTORY BUilding lIn~ (BL ! BSL) ropo U1""\S' - - - - - - - Easement Line IWrnill, . ,U Proposed landscape Area Community Restrictions: Side Yard = 5' MIN (ONE ~OE) Rear Yard = N!A Aggregate = 20% LOT \\\OTH Zoning = 51 Note: Sanitary Sewer Top of Costing information Upstream Manhole. TC= 904.43 Downstream Manhole, TC= 902.76 per plan. R.H. of Indiana Finished Floor Elevation Information IBM at toce of curt=905.3 IBM at alley=g04.4 Note: The contractor is to maintain a minimum distance of ten feet (10') between the sanitary sewer and water line laterals. Proposed Grade at Swole=906.3, high side Garage FIT at weotherlip=909,3-2.54=906.76 Residentioi FIT=906.3+3.0=909.3 Ground Cover Calculations: Drive = 796 SF J: Public Walk = 235 SH Private Walk = 71 SFJ: HyOroseeding =N!A SFJ: Sod = 346 SYJ:, entire yard Sidewalk to be placed l' from property line, 5.5' from bock of curb, per pion. I BUC~LAND STREET ROU CURB I ffiAV.90H (905.35) 18. 4(),75 8 0.38' BSIolNT 0.38"\ "' ~~ MA'!fIElD A ~ ~ fR~ & ~SY l<i. RE~DENCE 15. . 5.0 1.33' t: 13.58' 5.0 10.~ IS'XI3' C> o c;;~p PAm C> '" . $.8!:: ... 0 .no ~ .,.; .q- ~....r 10.00' a c> ..--- .33' 10,17$. ~ . lHREE CAR ~ 8. 0 . GARAGE 8 )0,00' CONC ORIVE .. :SMT 38.S' 90 .17 LLEY ESMT TC=902.7S PER PlAN SlR." 06 ~4 Note: This drawing is based on construction plans or record drawings, and is not based upon a field survey. The Schneider Corporation does not warrant the accuracy or sufficiency of this information. Contractors should verify existing conditions prior to any construction. Any discrepancy found on this drawing shouid be reported to The Schneider Corporation immediately; fo~ing to do so results in the contractors assumption of 011 liobmty. Note: The basement elevation, depicted hereon, has been determined and based upon the pad grades and/or contours taken from the construction plan . subdivision. Unless stated, no information abaut"'fl duating w tables, soil conditions, or soa t)pe:3 hoSbeen 'provided or s ted on sold pions. It Is recommenaed that the basement fi 'shed floor elevations be at IS two feet (2') above the no 01 pool elevation of any adp' ing bodies of water, u es a s dy of facts reveals oth ise. If during the exc ocess ony ground water l~ 'tJ n~ssed, The, Sch iderj .ion should ~~'notlfied imm tely. Th b e ion should be raised two feet (2') above ater, and additional construction techniques should be incorporated to alleviate future problems. Detam of Ground/ Storm Water flow pattern for Individual lots. Vb06.0052994 ~ Lot # 961 =~= ~ 'pi I I I \ I I I Nate: Buider to ensure positiye drainage away from structure(s). Note: Sump pump(s) to be placed by builder os needed. Note: Per Carmel zoning ordinance 26.1.1 : The residential district limits height to twenty-five feet (25'). hawever a dwelling may be increased in height to thirty-five feet (35') provided the side and rear yards are Increased on additional one foot (1') for each one foot (1') the structure exceeds the first twenty-five feet (25') in height. Assumed North Scale: 1. = 3D' Note: The gorage finished floor elevation Is 1.0' aboye middle of pavement at the drive. per plan. . ~I t ~ T"r'PtCAL SWALE SECTION FLOOD HAZARD STATEMENT CERTIFICATION ,1I1I\\\\\\lilillllll/I/", -fi:ov,\\ <:. L /l r/~ ~ ~'.";) . O:4h ~ .ffjf .., ............... 'T~~~ ~...-::5~"i ....G\ST~I?;:... ~A~ ~ -~","' N <,;,.. /V', ~ ~~ /~v" 0 ()\ /O~ ff2:' "'.. ~ i ( 50303 i I ~ . . ~ ~ .... STATE OF .... ~ \ ~ ;;....../AtOI A~ ~......~ i ~?"1g?.."""""".(,'\" ~ ~4/, SUR~ ~~~# Y////llillJlllll\\\\\\\\\\\ -\::l:-lF-v ~GNA lURE : OAl[: ~GNA lURE REPRESENTS CONnR~A ~ON Of RECEIPT Of PLOT PlAN BY CUSTOMER.