Loading...
HomeMy WebLinkAboutC600 - Storm Plan & Profile-C600SCALE: 1"=40' HOR. 1"=4' VERT. 840 850 860 840 850 860 8'' SDR-35 PVC INV=846.32 PROPOSED GRADE EXISTING GRADEVILLAGE CREEK DRIVEI.E. 850.8 6" SSDINLET #43648" DIA MHSTA. 3+65TC=854.08118 L.F. 0.29% 21" R.C.P. CLASS III 848.53 848.87 15 L.F. 0.29% 21" R.C.P. CLASS III UP INV.=848.91 DOWN INV.=848.87 HYDRAULIC GRADE LINEMANHOLE #435STA. 2+29TC=854.08CONC. CRADLE 24" MIN8" WATEREmma Lou Cunningham et alInst. No. 2014-0305971.84 Ac.±(M)JACKSON'S GRANT ONWILLIAMS CREEK SECTION 5Inst. No. 2017-054815Plat Cab. 5, Slide 758SS S S S S SVAR. D.U.&S.S.E.Gas Line EasementInst. No. 2017-013563Gas Line EasementInst. No. 2017-013563Gas Line EasementInst. No. 2017-013563Gas Line EasementInst. No. 2017-01356330'30' DRAINAGE FLOOD ROUTE EASEMENT INST. NO. 2020-069148 BILLY CREEK ASSOCIATES Inst. No. 92-022718 10 Ac.±(D) (Parcel 2)SPRINGMILL ROADVAR. R.D.E. & B.M.P.E. 435o o oo o oo o oo o oo o oo o o430429 428 427 434 433 432431 443 442 440439438 437 441 25' B.L.25' B.L.25' B.L.25' B.L.10' S.S.E. 15' S.S.E. VAR. U.E. 459 EX-2SPRINGMILL ROAD10' S.S.E.(PARKWAY COLLECTOR)(PARKWAY COLLECTOR)VILLAGE CREEK DRIVE (LOCAL) VILLAGE CREEK DRIVE (LOCAL)OTTO LANE(LOCAL)OTTO LANE(LOCAL)20' B.M.P.&U.E.20' B.M.P.&S.S.E.20' B.M.P.&S.S.E.20' B.M.P.&S.S.E.15' R.D.E.15' D.&U.E.15' D.&U.E.15' R.D.E. 15' R.D.E.15' R.D.E.WWW* * VAR. SI G N E ASE ME NT 447 445 444 446 450 452 451 447A 50' 1/2 R/W 50' 1/2 R/W W W W WWWWWWW* W W W W W W W W JGV819 JGV816JGV818 ALLEY B (PRIVATE)ALLEY C(PRIVATE)ALLEY D (PRIVATE) JGV817 JGV815WW WWW436 856 856 855 852852853854 855 852853854855853854856 856857855856857855 855 854 854855855 856 855 855 855 855855856855854856ALLEY A (PRIVAT E )ALLEY A(PRIVATE)855855856855 JGV820 ALLEY E (PRIVATE) 451A ** * * *** * * * * 10' B.L. 10' B.L. 10' D.U.&S . S . E . 10' D.U.&S.S.E. 10' D.U.&S.S.E.5' WALK5' WALK5' WALK5' WALK 5' WALK 5' WALK5' WALK5' WALK 5' WALK 5' WALK5' WALK5' WALK 5' WALK5' WALK5' WALK 5' WALK 5' WALK 10' B.L.10' B.L.10' B.L.10' B.L.10' B.L. FUT. BLDG. 5' L.B.E.5' L.B.E.5' L.B.E.5' L.B.E.VAR. I.E.E.VAR. I.E.E.& D.U.&S.S.E. VAR. I.E.E.& D.U.&S.S.E.VAR. D.U.&S.S.E.VAR. D.U.&S.S.E. VAR. D.U.&S.S.E. VAR. I.E.E.& D.U.&S.S.E. 464 463462 85585385485585285385485585 5 85 2 85 3 85 4855853854856855 855 855 85 6 8 5 7 855* * *8558' WALK 855 855 856 856 855 15' S.S.E. 38 * 856 5' WALK 5' WALK5' WALK13' D.U.&S.S.E. 30' D.U. & S.S.E. JGV814 66 56 59555857 626160 63 64 65 48 C.A. 2-814,549 sq.ft.71 70 69 68 67 54 52 53 51 49 50 C.A. 2-71,995 sq.ft. 37 34 36 35 33 47 46 45 10' B.L.10' B.L.WWWVILLAGE CORNER COURT(PRIVATE)C.A. 2-666,196 sq.ft.85285385439 44 424140 43C.A. #2-9350 sq.ft.STRM 440-452 SCALE: 1"=40' HOR. 1"=4' VERT. 840 850 860 840 850 860YARD INLET #45224" x 24" BOXSTA. 2+95TC=854.50INLET #45124" x 24" BOXSTA. 1+22TC=853.61EX. INLET #44048" DIA MHSTA. 0+00TC=853.778'' SDR-35 PVC INV=845.17 24'' RCP S INV.=848.24 30'' RCP W INV.=848.03 12'' RCP N INV.=849.15 PROPOSED GRADE EXISTING GRADE 111 L.F. 0.56% 12" R.C.P. CLAS S I I I 850.45 851.07 114 L.F. 0.67% 12" R.C.P. C L A S S I I I 849.06 849.82 HYDRAULIC GRADE LINE I.E. 850.3 6" SSD INLET #451A24" x 24" BOXSTA. 1+84TC=854.0062 L.F. 0.69% 12" R.C.P. CLASS III 849.92 850.35 I.E. 850.7 6" SSD I.E. 851.2 6" SSD SCALE: 1"=40' HOR. 1"=4' VERT. 840 850 860 840 850 860YARD INLET #45024" x 24" BOXSTA. 1+73TC=854.70EX. INLET #44148" DIA MHSTA. 0+00TC=853.9721'' RCP S INV.=848.45 24'' RCP N INV.=848.35 12'' RCP E INV.=850.56 EXISTING GRADE PROPOSED GRADE HYDRAULIC GRADE LINE 165 L.F. 0.30% 12" R.C.P. CLASS III 850.58 851.08 24" MIN8" WATER I.E. 851.4 6" SSD SCALE: 1"=40' HOR. 1"=4' VERT. 840 850 860 840 850 860INLET #44548" DIA MHSTA. 0+00TC=854.1912'' RCP W INV.=849.97 18'' RCP N INV.=849.87 12'' RCP E INV.=849.97 12'' RCP S INV.=849.97 PROPOSED GRADE EXISTING GRADE HYDRAULIC GRADE LINE 49 L.F. 0.69% 12" R.C.P. CLASS III UP INV.=850.31 DOWN INV.=849.97 I.E. 850.9 6" SSD STRM 445-447A SCALE: 1"=40' HOR. 1"=4' VERT. 840 850 860 840 850 860 INLET #44548" DIA MHSTA. 0+00TC=854.19INLET #44724" x 24" BOXSTA. 1+65TC=854.22INLET #447A24" x 24" BOXSTA. 3+25TC=854.428'' SDR-35 PVC INV=847.72 12'' RCP W INV.=849.97 18'' RCP N INV.=849.87 12'' RCP E INV.=849.97 12'' RCP S INV.=849.97 PROPOSED GRADE EXISTING GRADE 165 L.F. 0.30% 12'' RCP 849.97 850.46 160 L.F. 0.30% 12'' RCP 850.56 851.05 HYDRAULIC GRADE LINE I.E. 851.5 6" SSD I.E. 850.9 6" SSD I.E. 850.9 6" SSDCONC. CRADLE 24" MIN8" WATER SCALE: 1"=40' HOR. 1"=4' VERT. 840 850 860 840 850 860 12'' RCP W INV.=849.97 18'' RCP N INV.=849.87 12'' RCP E INV.=849.97 12'' RCP S INV.=849.97 8'' SDR-35 PVC INV=847.88 PROPOSED GRADE PROPOSED GRADE EXISTING GRADE 8'' SDR-35 PVC INV=847.8418" MIN8" WATER CONC. CRADLE INLET #44448" DIA MHSTA. 10+48TC=854.19INLET #44548" DIA MHSTA. 11+82TC=854.19INLET #44624" x 24" BOXSTA. 13+06TC=854.19124 L.F. 0.42% 12" R.C.P. CLASS III 849.97 850.49 134 L.F. 0.22% 18" R.C.P. CLASS III 849.58 849.87 101 L.F. 0.26% 21" R.C.P. CLASS III 849.22 849.48 18 L.F. 0.26% 21" R.C.P. CLASS III UP INV.=849.22 DOWN INV.=849.17MANHOLE #443STA. 9+29TC=854.10I.E. 850.9 6" SSD I.E. 850.9 6" SSD I.E. 850.9 6" SSD HYDRAULIC GRADE LINE CONC. CRADLE STORM PIPE TABLE NAME 445-446 441-450 447-447A 435-436 445-447 444-445 443-444 451A-452 440-451 436 (STUB) 463-464 462-463 445-448 (STUB) 430-462 451-451A SIZE 12" 12" 12" 21" 12" 18" 21" 12" 12" 21" 12" 12" 12" 12" 12" LENGTH 124.32' 165.30' 160.00' 117.71' 165.00' 134.04' 101.07' 111.00' 114.00' 15.00' 135.50' 126.00' 49.50' 25.14' 62.30' SLOPE 0.42% 0.30% 0.30% 0.29% 0.30% 0.22% 0.26% 0.56% 0.67% 0.29% 0.32% 0.37% 0.69% 1.95% 0.69% MATERIAL R.C.P. R.C.P. R.C.P. R.C.P. R.C.P. R.C.P. R.C.P. R.C.P. R.C.P. R.C.P. R.C.P. R.C.P. HDPE HDPE HDPE STORM STRUCTURE TABLE STR.# 436 444 445 446 447 447A 448 450 451 452 462 463 464 TYPE INLET INLET INLET INLET INLET INLET INLET YARD INLET INLET YARD INLET YARD INLET YARD INLET YARD INLET T.C. 854.08 854.19 854.19 854.19 854.22 854.42 854.19 854.70 853.61 854.50 854.50 855.10 855.70 CASTING TYPE R-3405 R-3405 R-3405 R-3405 R-3405 R-3405 R-3405 R-4342 R-3405 R-4342 1299CGD 1299CGD 1299CGD DIA. IN 21 18 12 12 12 12 12 12 12 DIR. IN S S W E S S E E E INV. IN 848.87 849.58 849.97 849.97 849.97 850.56 849.92 850.95 851.52 DIA. OUT 21 21 18 12 12 12 12 12 12 12 12 12 12 DIR. OUT N N N N E N W W S W SW W W INV. OUT 848.87 849.48 849.87 850.49 850.46 851.05 850.49 851.08 849.82 851.07 850.85 851.42 851.95 SLOPE 0.29% 0.26% 0.22% 0.42% 0.30% 0.30% 0.69% 0.30% 0.67% 0.56% 1.95% 0.37% 0.32% DESCRIPTION SEE STANDARD MANHOLE DETAIL D-20 ON SHEET C802 SEE STANDARD MANHOLE DETAIL D-20 ON SHEET C802 SEE STANDARD MANHOLE DETAIL D-20 ON SHEET C802 SEE CATCH BASIN DETAIL ON SHEET C802 SEE CATCH BASIN DETAIL ON SHEET C802 SEE CATCH BASIN DETAIL ON SHEET C802 SEE CATCH BASIN DETAIL ON SHEET C802 SEE CATCH BASIN DETAIL ON SHEET C802 SEE CATCH BASIN DETAIL ON SHEET C802 SEE CATCH BASIN DETAIL ON SHEET C802 SEE NYLOPLAST DRAIN BASIN DETAIL ON SHEET C802 SEE NYLOPLAST DRAIN BASIN DETAIL ON SHEET C802 SEE NYLOPLAST DRAIN BASIN DETAIL ON SHEET C802 SCALE: 1"=40' HOR. 1"=4' VERT. 845 850 860 845 850 860 25 L.F. 1.95% 12" ADS N-12/HANCOR DUAL WALL UP INV.=850.85 DOWN INV.=850.36 136 L.F. 0.32% 12" ADS N-12/HANCOR DUAL WALL 851.52 851.95 126 L.F. 0.37% 12" ADS N-12/HANCOR DUAL WALL 850.95 851.42 12'' RCP W INV.=850.26YARD INLET #462NYLOPLASTDRAIN BASINSTA. 0+25TC=854.50YARD INLET #463NYLOPLASTDRAIN BASINSTA. 1+51TC=855.10YARD INLET #464NYLOPLASTDRAIN BASINSTA. 2+87TC=855.70PROPOSED GRADE EXISTING GRADECURB INLET #43048" DIA MHSTA. 0+00TC=854.22HYDRAULIC GRADE LINE 60160JGV-R2 AEC BKR CARMEL, CLAY TOWNSHIPHAMILTON COUNTY, INDIANA03/16/22File Name:S:\60160-JGV-R2\DWG\C600 - Storm Plan & Profile.dwg - C600Modified / By:July 27, 2022 9:04:17 AM / RMorrisPlotted / By:September 29, 2022 11:29:31 AM / Raven MorrisJACKSON'S GRANT VILLAGESECTION 2NOTES ALL STORM STRUCTURES TO RECEIVE SOLID LID CASTINGS ARE TO BE CONSTRUCTED TO PROVIDE ONE 4" RISER RING NO MORE, NO LESS TO ACHIEVE PLAN RIM GRADE. ALL YARD INLETS ARE TO BE CONSTRUCTED AT A TOLERANCE OF +0.00' TO -0.20' OF PLAN GRADE. ALL STORM SEWER CASTINGS SHALL BE LABELED "DUMP NO WASTE-DRAINS TO WATERWAY" ALL SSD'S (SUBSURFACE DRAINS) WILL NEED TO BE DOUBLE WALL SMOOTH BORE PERFORATED (HDPE) PIPE. DEBRIS GUARDS ARE TO BE INSTALLED ON ALL OPEN ENDED INLETS. FOR STORM STRUCTURE SIZING AND CASTING TABLE SEE STANDARD PLAN D-18 ON SHEET C801A. ALL STORM SEWERS WITHIN PUBLIC RIGHT-OF-WAY SHALL BE RCP CLASS III. FOR INSTALLATION OF STORM UNDER CITY STREETS AND COVER REQUIREMENTS, SEE STANDARD DRAWING 10-31 ON SHEET C801A. ALL TOP OF CASTING ELEVATIONS FOR STORM SEWERS SHALL BE CONSTRUCTED WITH A TOLERANCE OF 0.10 FT±. MINIMUM COVER FOR PIPE CROSSINGS OF CITY STREETS: THE MINIMUM COVER FROM THE TOP OF THE INSTALLED PAVEMENT TO THE TOP OF THE INSTALLED PIPE SHALL BE THE PAVEMENT SECTION, THICKNESS (ALL BITUMINOUS AND AGGREGATE MATERIAL ABOVE THE SUBGRADE) PLUS 1'-0", BUT UNDER NO CIRCUMSTANCES SHALL THE COVER ALONG ANY PART OF THE PIPE FROM THE FINAL PAVEMENT ELEVATION TO THE TOP OF THE PIPE BE LESS THAN 2.5 FEET. THE STORM SEWER SYSTEM SHALL BE CONSTRUCTED PER DESIGN SPECIFIED AND AS APPROVED BY THE CITY OF CARMEL ON THE FINAL APPROVED CONSTRUCTION PLANS. DESIGN SPECIFIED AND AS APPROVED BY THE CITY OF CARMEL ON THE FINAL APPROVED CONSTRUCTION PLANS. DEVIATIONS FROM THE APPROVED DESIGN SHALL ONLY BE PERMITTED DUE TO SPECIAL CIRCUMSTANCES OR DIFFICULTY DURING CONSTRUCTION AND WILL REQUIRE PRIOR FIELD APPROVAL FROM A DESIGNATED REPRESENTATIVE OF THE CITY OR CARMEL IN ADDITION TO SUPPLEMENTAL APPROVAL BY THE DESIGN ENGINEER. AN EXPLANATION OF ANY SUCH DEVIATION SHALL BE INCLUDED AS A REQUIREMENT ON AS-BUILT/RECORD DRAWINGS SUBMITTED FOR RELEASE OF PERFORMANCE GUARANTEES. APPROVED DESIGN SLOPES IDENTIFIED AS GENERATING VELOCITIES OF 2.5 FPS OR LESS AND 10 FPS OR GREATER (AT FULL FLOW CAPACITY) SHALL REQUIRE AS-BUILT CERTIFICATION AT THE TIME OF CONSTRUCTION, PRIOR TO BACKFILLING THE PIPE. THE CONTRACTOR IS INSTRUCTED TO AS-BUILT EACH SECTION OF STORM PIPE AS IT IS BEING INSTALLED TO ENSURE COMPLIANCE WITH THE DESIGN PLANS, AND AS APPROVED BY THE CITY OF CARMEL. UTILITY CROSSINGS CONTRACTOR SHALL VERIFY DEPTHS OF ALL EXISTING ONSITE UTILITIES PRIOR TO CONSTRUCTION TO CONFIRM THERE IS NOT ANY CONFLICTS WITH OTHER UTILITIES, STORM SEWERS OR STREETS. CONFLICTS AFTER CONSTRUCTION BEGINS ARE SOLELY THE CONTRACTOR'S RESPONSIBILITY. GRAPHIC SCALE ( IN FEET ) 1" = 50 FT LEGEND EXISTING SANITARY SEWER EXISTING STORM SEWER EXISTING WATER LINE PROPOSED SANITARY SEWER PROPOSED STORM SEWER PROPOSED WATER LINE DENOTES FULL DEPTH GRANULAR BACKFILL (SEE TRENCH DETAIL 10-31 ON SHEET C802)DATEMARKREVISIONSBYCERTIFIED:S & A JOB NO. SHEET NO. DRAWN BY:CHECKED BY:S T O E P P E L W E R T HA L W A Y S O N7965 East 106th Street, Fishers, IN 46038-2505phone: 317.849.5935 fax: 317.849.5942THIS DRAWING IS NOT INTENDED TO BE REPRESENTED AS A RETRACEMENT OR ORIGINAL BOUNDARY SURVEY, A ROUTE SURVEY OR A SURVEYOR LOCATIONREPORT.STORM SEWER PLAN & PROFILESC600REVISED PER REVIEW COMMENTS07/18/22RBMSTORM SYSTEM STORM SEWER FROM STR #430 TO STR #464, AND SUB-SURFACE DRAINS CONNECTING TO STR #450 AND STR #452 WILL BE PRIVATE. ALL OTHER STORM SEWERS FOR THIS DEVELOPMENT WILL BE COUNTRY REGULATED, AND WILL LIE WITHIN A 30' REGULATED DRAIN EASEMENT. DRAINAGE SUMMARY OVERALL Site Acreage=+/-20.89 ac. Offsite/Upstream Acreage=None Allowable Release Rate: 10yr = 2.75 c.f.s. 100yr = 5.14 c.f.s. Post Developed Release Rate: 10 yr = 2.66 c.f.s. 100 yr = 4.76 c.f.s. Is the primary water quality treatment for the development as planned in the Master Plan - YES If NO, provide the following information per BMP (Only for BMP's with vegetative swale req.): *Length of vegetated swale treatment (from disharge point to outlet pipe) - N/A *Minimum length of vegetated swale treatment as required by the Master Plan - N/A Is the primary water quantity treatment for the development as planned in the Master Plan - YES *If YES, provide the following information: Total Master Plan contributing watershed = 20.89 Ac. Total Watershed Currently Built (or Approved) contributing to this system = 0 Ac. Total watershed from Jackson's Grant Villages contributing to the system = 20.89 Ac. Total watershed available in the system post-project = 20.89 Ac. Is the entire BMP treatment train to an outlet point being constructed with this section - YES If NO, provide the following information: Detention Basins BMP's Constructed with this section. (See BMP pond data table-this sheet) - N/A Also, reference Post-Construction Stormwater Master Plan prepared by Williams Creek Consulting.